964 resultados para TYROSINASE-BASED BIOSENSOR


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Biosensors are used for a large number of applications within biotechnology, including the pharmaceutical industry and life sciences. Since the production of Biacore surface-plasmon resonance instruments in the early 1990s, there has been steadily growing use of this technology for the detection of food contaminants (e.g., veterinary drugs, mycotoxins, marine toxins, food dyes and processing contaminants). Other biosensing technologies (e.g., electrochemical and piezoelectric) have also been employed for the analysis of small-molecule contaminants. This review concentrates on recent advances made in detection and quantification of antimicrobial compounds with different types of biosensors and on the emergence of multiplexing, which is highly desirable as it increases sample analysis at lower cost and in less time. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Paralytic shellfish poisoning (PSP) toxins are produced by certain marine dinoflagellates and may accumulate in bivalve molluscs through filter feeding. The Mouse Bioassay (MBA) is the internationally recognised reference method of analysis, but it is prone to technical difficulties and regarded with increasing disapproval due to ethical reasons. As such, alternative methods are required. A rapid surface plasmon resonance (SPR) biosensor inhibition assay was developed to detect PSP toxins in shellfish by employing a saxitoxin polyclonal antibody (R895). Using an assay developed for and validated on the Biacore Q biosensor system, this project focused on transferring the assay to a high-throughput, Biacore T100 biosensor in another laboratory. This was achieved using a prototype PSP toxin kit and recommended assay parameters based on the Biacore Q method. A monoclonal antibody (GT13A) was also assessed. Even though these two instruments are based on SPR principles, they vary widely in their mode of operation including differences in the integrated mu-fluidic cartridges, autosampler system, and sensor chip compatibilities. Shellfish samples (n = 60), extracted using a simple, rapid procedure, were analysed using each platform, and results were compared to AOAC high performance liquid chromatography (HPLC) and MBA methods. The overall agreement, based on statistical 2 x 2 comparison tables, between each method ranged from 85% to 94.4% using R895 and 77.8% to 100% using GT13A. The results demonstrated that the antibody based assays with high sensitivity and broad specificity to PSP toxins can be applied to different biosensor platforms. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pantothenicacid (PA), vitamin B5, is an essential B vitamin that may be fortified in food and as such requires robust and accurate methods of detection to meet compliance legislation. This study reports the production and characterisation of the first monoclonalantibody (MAb) specific for PA and the subsequent development of a surface plasmon resonance (SPR) biosensorassay for the quantification of PA. The developed assay was compared with an SPR based commercial kit which utilised a polyclonal antibody (PAb). Foodstuffs, including cereals (n = 43), infant formulas and baby food (n = 10) and fruit juices (n = 48) were analysed by both the MAb and PAb biosensorassays and comparison plots showed good correlation (R2 0.77–0.99). The results indicate that the MAb basedbiosensorassay is suitable for the measurement of PA in foodstuffs and has the added advantage of facilitating a constant, long term supply of identical antibody. Preliminary matrix studies suggest the MAb basedassay is an excellent candidate for further validation studies and routine quality assurance based analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ecotoxicological screening of dust sampled throughout a Kenyan tannery was conducted using a luminescence (lux)-based bacterial biosensor for both solid and liquid assays. This was complemented by chemical analysis in an attempt to identify possible causative toxic components. The biosensor results showed a highly significant (p <0.001) difference in both solid and liquid phase toxicity in samples collected from various identified sampling points in the tannery. A positive correlation was observed between results of the solid and liquid phase techniques, for most of the sampling points indicating that the toxic contaminants were bioavailable both in the solid and liquid state. However, the results generally indicated toxicity associated with liquid phase except certain areas in solid phase such as chemical handling, buffing area and weighing. The most toxic tannery area identified was the weighing area (p <0.001), showing the lowest bioluminescence for both the solid (0.38 +/- 2.21) and liquid phases (0.01 +/- 0.001). Chromium was the metal present in the highest concentration indicating levels higher than the stipulated regulatory requirement of 0.5 mg Cr/m3 for total Cr (highest Cr concentration was at chemical handling at 209.24 mg l(-1)) in all dust samples. The weighing area had the highest Ni concentration (1.87 mg l(-1)) and the chemical handling area showed the highest Zn concentration (31.9 mg l(-1)). These results raise environmental health concerns, as occupational exposure to dust samples from this site has been shown to give rise to elevated concentrations (above the stipulated levels) of chromium in blood, urine and some body tissues, with inhalation being the main route. Health and Safety Executive (HSE), UK, and American Conference of Governmental Industrial Hygienist (ACGIH) and National Institute for Occupational Safety and Health (NIOSH), USA stipulates an occupational exposure limit of 0.5 mg Cr/m3 (8 h TWA) for total chromium. However, schedule 1 of Controls of substances hazardous to health (COSHH) regulations developed by HSE, indicate 0.05 mg m3 (8 h TWA reference periods) to be the limit for Cr (VI) exposure. The exposure limit for individual (e.g., Cr, Zn, Ni etc.) contaminants (homogeneity) was not exceeded, but potential impact of heterogeneity (multi-element synergistic effect) on toxicity requires application of the precautionary principle.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this study, a gold nanoparticle (Au-NP)-based detection method for sensitive and specific DNA-based diagnostic applications is described. A sandwich format consisting of Au-NPs/DNA/PMP (Streptavidin-coated MagnetSphere Para-Magnetic Particles) was fabricated. PMPs captured and separated target DNA while Au-NPs modified with oligonucleotide detection sequences played a role in recognition and signal production. Due to the much lower stability of mismatched DNA strands caused by unstable duplex structures in solutions of relatively low salt concentration, hybridization efficiency in the presence of different buffers was well investigated, and thus, the optimized salt concentration allowed for discrimination of single-mismatched DNA (MMT) from perfectly matched DNA (PMT). Therefore, quantitative information concerning the target analyte was translated into a colorimetric signal, which could easily and quantitatively measured by low-cost UV–vis spectrophotometric analysis. The results indicated this to be a very simple and economic strategy for detection of single-mismatched DNA strands.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Kenyan tannery and associated environmental samples were selected for ecotoxicological assessment. A tool-kit of techniques was developed, including whole-cell biosensor and chemical assays. A luminescence based bacterial biosensor (Escherichia coli HB101 pUCD607) (via a multi-copy plasmid) was used for toxicity assessment. Samples were manipulated prior to biosensor interrogation to identify the nature of the toxic contaminants. Untreated samples (before any manipulations) showed a strong toxic effect at the discharge point in comparison to other sampling points. Sparging was used to identify toxicity associated with volatile organics. The toxicity of contaminants, removed by treatment with activated charcoal was identified for all the sampling points except for those upstream of effluent discharges. Filtration identified toxicity associated with suspended solids. Changes in availability of toxic contaminants due to pH adjustment of most samples from the tannery effluent treatment pits were also associated with the extreme pH values (4.0 and 8.0). The approach used has highlighted the complexicity of toxic pollutants in effluent from the tanning industry and the dissection of toxicity points to possible remediation strategies for effluents from the tanning industry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The performance of an amperometric biosensor constructed by associating tyrosinase (Tyr) enzyme with the advantages of a 3D gold nanoelectrode ensemble (GNEE) is evaluated in a flow-injection analysis (FIA) system for the analysis of l-dopa. GNEEs were fabricated by electroless deposition of the metal within the pores of polycarbonate track-etched membranes. A simple solvent etching procedure based on the solubility of polycarbonate membranes is adopted for the fabrication of the 3D GNEE. Afterward, enzyme was immobilized onto preformed self-assembled monolayers of cysteamine on the 3D GNEEs (GNEE-Tyr) via cross-linking with glutaraldehyde. The experimental conditions of the FIA system, such as the detection potential (−0.200 V vs. Ag/AgCl) and flow rates (1.0 mL min−1) were optimized. Analytical responses for l-dopa were obtained in a wide concentration range between 1 × 10−8 mol L−1 and 1 × 10−2 mol L−1. The limit of quantification was found to be 1 × 10−8 mol L−1 with a resultant % RSD of 7.23% (n = 5). The limit of detection was found to be 1 × 10−9 mol L−1 (S/N = 3). The common interfering compounds, namely glucose (10 mmol L−1), ascorbic acid (10 mmol L−1), and urea (10 mmol L−1), were studied. The recovery of l-dopa (1 × 10−7 mol L−1) from spiked urine samples was found to be 96%. Therefore, the developed method is adequate to be applied in the clinical analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Shallow groundwater beneath a former airfield site in southern England has been heavily contaminated with a wide range of chlorinated solvents. The feasibility of using bacterial biosensors to complement chemical analysis and enable cost-effective, and focussed sampling has been assessed as part of a site evaluation programme. Five different biosensors, three metabolic (Vibrio fischeri, Pseudomonas fluorescens 10568 and Escherichia coli HB101) and two catabolic (Pseudomonas putida TVA8 and E. coli DH5alpha), were employed to identify areas where the availability and toxicity of pollutants is of most immediate environmental concern. The biosensors used showed different sensitivities to each other and to the groundwater samples tested. There was generally a good agreement with chemical analyses. The potential efficacy of remediation strategies was explored by coupling sample manipulation to biosensor tests. Manipulation involved sparging and charcoal treatment procedures to simulate remediative engineering solutions. Sparging was sufficient at most locations. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work reports the utilization of two methodologies for carbaryl determination in tomatoes. The measurements were carried out using an amperometric biosensor technique based on the inhibition of acetylcholinesterase activity due to carbaryl adsorption and a HPLC procedure. The electrochemical experiments were performed in 0.1 mol L-1 phosphate buffer solutions at pH 7.4 with an incubation time of 8 min. The analytical curve obtained in pure solutions showed excellent linearity in the 5.0 x 10(-5) to 75 x 10(-5) mol L-1 range, with the limit of detection at 0.4 x 10(-3) gL(-1). The application of such a methodology in tomato samples involved solely liquidising the samples, which were spiked with 6.0 x 10(-6) and 5.0 x 10(-5) mol L-1 carbaryl. Recovery in such samples presented values of 99.0 and 92.4%, respectively. In order to obtain a comparison, HPLC experiments were also conducted under similar conditions. However, the tomato samples have to be manipulated by an extraction procedure (MSPD), which yielded much lower recovery values (78.3 and 84.8%, respectively). On the other hand, the detection limit obtained was much lower than that for the biosensor, i.e., 3.2 x 10(-6) g L-1. Finally, the biosensor methodology was employed to analyze carbaryl directly inside the tomato, without any previous manipulation. In this case, the biosensor was immersed in the tomato pulp, which had previously been spiked with the pesticide for 8 min, removed and inserted in the electrochemical cell. A recovery of 83.4% was obtained, showing very low interference of the matrix constituents. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An amperometric biosensor for salicylate detection was developed by immobilizing salicylate hydroxylase via glutaraldehyde onto a polypyrrole film doped with hexacyanoferrate, supported on a glassy carbon electrode surface. The sensor monitors the catechol produced in the enzymatic reaction on the film surface, at an applied potential of 150 mV vs. SCE. A [NADH]/[salicylate] ratio between 2 and 4 gave the best response. The biosensor presented the best performance in a solution with pH=7.4. The response time was about 40 s. A linear range of response was observed for salicylate concentrations between 1.0x10(-5) and 1.0x10(-4) mol l(-1) and the equation adjusted for this curve was I=(-0.04+/-0.01)+(11.4+/-0.2)[salicylate] with a correlation coefficient of 0.999 for n=6. The biosensor retains its activity for at least 10 days despite daily use. The results obtained using the biosensor for salicylate determination, in three different samples of antithermic drugs, presented a good correlation with the standard colorimetric method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)