967 resultados para TRACE IMPURITIES
Resumo:
This report is a brief overview of the recent Iowa Department of Transportation research in the area of durability of Portland cement, concrete under the direction of Wendeli Dubberke. Present plans are to publish a more detailed report on low Portland cement concrete- durability research in January, 1985.
Resumo:
Le rein participe directement ou indirectement à de nombreux processus pathologiques s'accompagnant d'une rétention hydrosodée. L'étude des mécanismes impliqués et de leur localisation intrarénale est un élément important pour l'élaboration d'un diagnostic et d'une thérapeutique rationnelle. Des outils sont nécessaires à cette fin. Il y a 25 ans, Thomsen et Schou ont proposé la clairance du lithium comme marqueur de la réabsorption de fluide et de sodium au niveau du tubule rénal proximal. L'administration de lithium exogène semble cependant perturber l'homéostasie électrolytique rénale en entraînant une natriurèse transitoire. Depuis peu, la possibilité existe de quantifier le lithium présent en trace dans le corps humain et de déterminer ainsi sa clairance rénale. Cette nouvelle approche évite toute altération de l'homéostasie du sodium et ouvre un vaste champ d'étude. Il permet de préciser certains problèmes diagnostiques, d'éclairer des mécanismes physiopathologiques, et mène ainsi à des thérapies plus judicieuses.
Resumo:
The U-Pb ages and the trace element content of zircon U-Pb along with major and trace element whole rock data on gabbroic dikes from the Lanzo lherzolitic massif, N-Italy, have been determined to constrain crustal accretion in ocean-continent transition zones. Three Fe-Ti gabbros were dated from the central and the southern part of the massif providing middle Jurassic ages of 161 +/- 2, 158 +/- 2 and 163 +/- 1 Ma, which argue for magmatic activity over few millions of years. Zircon crystals are characterized by high but variable Th/U ratios, rare earth element patterns enriched in heavy rare earths, pronounced positive Ce and negative Eu-anomalies consistent with crystallization after substantial plagioclase fractionation. The zircon trace element composition coupled with whole rock chemistry was used to reconstruct the crystallization history of the gabbros. A number of gabbros crystallized in situ, and zircon precipitated from trapped, intercumulus liquid, while other gabbros represent residual liquids that were extracted from a cumulus pile and crystallized along syn-magmatic shear zones. We propose a model in which the emplacement mechanism of gabbroic rocks in ocean-continent transition zones evolves from in situ crystallization to stratified crystallization with efficient extraction of residual liquid along syn-magmatic shear zones. Such an evolution of the crystallization history is probably related to the thermal evolution of the underlying mantle lithosphere.
Resumo:
Erilaisia epäpuhtauksia kulkeutuu paperinvalmistusprosessiin ja monenlaisia saostumia muodostuu paperinvalmistuksen prosesseissa. Epäpuhtaudet voivat aiheuttaa prosessiongelmia sekä alentaa tuotteen laatua. Epäpuhtauksien alkuperän ja koostumuksen selvittäminen edellyttää usein erilaisten analyysimenetelmien käyttöä. Epäpuhtauksien luokittelu on useasti välttämätöntä ennen tarkempaa kemiallista analyysia. Paperinvalmistuksen epäpuhtauksien kvalitatiiviseen luokitteluun on yleisimmin käytetty mikroskopian, IR-spektroskopian ja analyyttisen pyrolyysin menetelmiä. Raman spektroskopia on harvinaisempi menetelmä paperiteollisuuden tutkimuksessa. Raman instrumenttien kehittyminen on ollut voimakasta viimeisen vuosikymmenen aikana. Raman spektroskopia onkin osoittanut mandollisuutensa polymeerien, lääketeollisuuden ja polttoaineteollisuuden tutkimuksissa. Tässä työssä tutkittiin erään elintarvikepakkauskartongin epäpuhtauksia Raman spektroskoopilla. Työn tavoitteena oli selvittää Raman analyysin käyttökelpoisuutta kartongin epäpuhtauksien online-luokittelussa. Tutkimukset suoritettiin Spectracoden RP-1 Raman instrumentilla. Tutkimukset osoittivat, että näytteen fluoresenssi ja näytteen hajoaminen asettavat rajoituksia epäpuhtauksien Raman analyysille. Epäpuhtauksien online-tunnistaminen toimii käytettäessä suuria lasertehoja ja säteilytysaikoja. Näytteiden laserherkkyys ja fluoresenssi rajoittavat kuitenkin suurien laiteparametrien käyttöä. Laiteparametrien pienentäminen johti mittauksien signaali-kohina suhteen alenemiseen, mikä puolestaan aiheutti online-tunnistuksen toimimattomuuden.
Resumo:
Diplomityön tavoitteena on paineistimen yksityiskohtainen mallintaminen APROS- ja TRACE- termohydrauliikkaohjelmistoja käyttäen. Rakennetut paineistinmallit testattiin vertaamalla laskentatuloksia paineistimen täyttymistä, tyhjentymistä ja ruiskutusta käsittelevistä erilliskokeista saatuun mittausdataan. Tutkimuksen päätavoitteena on APROSin paineistinmallin validoiminen käyttäen vertailuaineistona PACTEL ATWS-koesarjan sopivia paineistinkokeita sekä MIT Pressurizer- ja Neptunus- erilliskokeita. Lisäksi rakennettiin malli Loviisan ydinvoimalaitoksen paineistimesta, jota käytettiin turbiinitrippitransientin simulointiin tarkoituksena selvittää mahdolliset voimalaitoksen ja koelaitteistojen mittakaavaerosta johtuvat vaikutukset APROSin paineistinlaskentaan. Kokeiden simuloinnissa testattiin erilaisia noodituksia ja mallinnusvaihtoehtoja, kuten entalpian ensimmäisen ja toisen kertaluvun diskretisointia, ja APROSin sekä TRACEn antamia tuloksia vertailtiin kattavasti toisiinsa. APROSin paineistinmallin lämmönsiirtokorrelaatioissa havaittiin merkittävä puute ja laskentatuloksiin saatiin huomattava parannus ottamalla käyttöön uusi seinämälauhtumismalli. Työssä tehdyt TRACE-simulaatiot ovat osa United States Nuclear Regulatory Commissionin kansainvälistä CAMP-koodinkehitys-ja validointiohjelmaa.
Resumo:
Tämän työn tarkoituksena on selvittää, miten höyryn kosteuden erotus toimii Kemijärven Sellun soodakattilassa. Höyryn kosteuden erotuksen toiminta tarkastetaan määrittämällä höyryn kosteus tulistetussa höyryssä. Höyryyn kulkeutuvan kattilaveden määrä määritettiin käyttäen merkkiaineena natriumia, jota kulkeutuu höyryyn kattilavesipisaroiden sekä ruiskutusveden mukana. Pieniä määriä kulkeutuu myös haihtumalla, mikä on otettu laskuissa huomioon. Kattilaveden ja höyryn natriumpitoisuuksien suhteen perusteella lasketaan kosteusprosentti. Kattilaveden kulkeutuessa höyryyn kulkeutuu veden mukana myös epäpuhtauksia, jotka turbiiniin joutuessaan saattavat aiheuttaa korroosiota sekä kerrostumia turbiinin siivistössä. Kosteuden erotuksen parantamiseksi on esitetty muutosehdotus siten, että nykyinen poimulevyerottimilla toteutettu sekundäärierotus korvattaisiin uudella teräsverkkoerottimella. Tällöin pystyttäisiin poistamaan entistä pienempiä pisaroita ja vähentämään höyryyn kulkeutuvan kattilaveden määrää.
Resumo:
Environmentally harmful consequences of fossil fuel utilisation andthe landfilling of wastes have increased the interest among the energy producers to consider the use of alternative fuels like wood fuels and Refuse-Derived Fuels, RDFs. The fluidised bed technology that allows the flexible use of a variety of different fuels is commonly used at small- and medium-sized power plants ofmunicipalities and industry in Finland. Since there is only one mass-burn plantcurrently in operation in the country and no intention to build new ones, the co-firing of pre-processed wastes in fluidised bed boilers has become the most generally applied waste-to-energy concept in Finland. The recently validated EU Directive on Incineration of Wastes aims to mitigate environmentally harmful pollutants of waste incineration and co-incineration of wastes with conventional fuels. Apart from gaseous flue gas pollutants and dust, the emissions of toxic tracemetals are limited. The implementation of the Directive's restrictions in the Finnish legislation is assumed to limit the co-firing of waste fuels, due to the insufficient reduction of the regulated air pollutants in the existing flue gas cleaning devices. Trace metals emission formation and reduction in the ESP, the condensing wet scrubber, the fabric filter, and the humidification reactor were studied, experimentally, in full- and pilot-scale combustors utilising the bubbling fluidised bed technology, and, theoretically, by means of reactor model calculations. The core of the model is a thermodynamic equilibrium analysis. The experiments were carried out with wood chips, sawdust, and peat, and their refuse-derived fuel, RDF, blends. In all, ten different fuels or fuel blends were tested. Relatively high concentrations of trace metals in RDFs compared to the concentrations of these metals in wood fuels increased the trace metal concentrations in the flue gas after the boiler ten- to hundred-folds, when RDF was co-fired with sawdust in a full-scale BFB boiler. In the case of peat, lesser increase in trace metal concentrations was observed, due to the higher initial trace metal concentrations of peat compared to sawdust. Despite the high removal rate of most of the trace metals in the ESP, the Directive emission limits for trace metals were exceeded in each of the RDF co-firing tests. The dominat trace metals in fluegas after the ESP were Cu, Pb and Mn. In the condensing wet scrubber, the flue gas trace metal emissions were reduced below the Directive emission limits, whenRDF pellet was used as a co-firing fuel together with sawdust and peat. High chlorine content of the RDFs enhanced the mercuric chloride formation and hence the mercury removal in the ESP and scrubber. Mercury emissions were lower than theDirective emission limit for total Hg, 0.05 mg/Nm3, in all full-scale co-firingtests already in the flue gas after the ESP. The pilot-scale experiments with aBFB combustor equipped with a fabric filter revealed that the fabric filter alone is able to reduce the trace metal concentrations, including mercury, in the flue gas during the RDF co-firing approximately to the same level as they are during the wood chip firing. Lower trace metal emissions than the Directive limits were easily reached even with a 40% thermal share of RDF co-firing with sawdust.Enrichment of trace metals in the submicron fly ash particle fraction because of RDF co-firing was not observed in the test runs where sawdust was used as the main fuel. The combustion of RDF pellets with peat caused an enrichment of As, Cd, Co, Pb, Sb, and V in the submicron particle mode. Accumulation and release oftrace metals in the bed material was examined by means of a bed material analysis, mass balance calculations and a reactor model. Lead, zinc and copper were found to have a tendency to be accumulated in the bed material but also to have a tendency to be released from the bed material into the combustion gases, if the combustion conditions were changed. The concentration of the trace metal in the combustion gases of the bubbling fluidised bed boiler was found to be a summary of trace metal fluxes from three main sources. They were (1) the trace metal flux from the burning fuel particle (2) the trace metal flux from the ash in the bed, and (3) the trace metal flux from the active alkali metal layer on the sand (and ash) particles in the bed. The amount of chlorine in the system, the combustion temperature, the fuel ash composition and the saturation state of the bed material in regard to trace metals were discovered to be key factors affecting therelease process. During the co-firing of waste fuels with variable amounts of e.g. ash and chlorine, it is extremely important to consider the possible ongoingaccumulation and/or release of the trace metals in the bed, when determining the flue gas trace metal emissions. If the state of the combustion process in regard to trace metals accumulation and/or release in the bed material is not known,it may happen that emissions from the bed material rather than the combustion of the fuel in question are measured and reported.
Resumo:
BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.
Resumo:
Détecter et comprendre les formes de criminalité, notamment organisées, qui sont impliquées dans la fabrication, la diffusion et/ou l'utilisation de faux documents d'identité est un enjeu complexe et persistant, mais est une nécessité pour soutenir l'action de la sécurité et l'étude des phénomènes criminels. A cet égard, il est postulé qu'une approche traçologique s'appuyant sur un profilage systématique des caractéristiques matérielles des faux documents d'identité peut fournir des renseignements criminels originaux, utiles et pertinents. Une méthode générale a été développée pour extraire, mémoriser et comparer systématiquement les profils des faux documents d'identité saisis par les acteurs de la sécurité. Cette méthode permet de détecter et de suivre les relations entre cas, les tendances et patterns criminels, dont l'interprétation au travers de différentes formes d'analyse permet la mise en évidence de potentiels groupes criminels, d'auteurs prolifiques et de <i>modus operandi</i> récurrents. Par l'étude de centaines de faux documents d'identité saisis par la police et les garde-frontière dans deux pays distincts, cet article démontre comment le renseignement forensique peut soutenir la génération et l'étude d'hypothèses sur la criminalité, aidant par-là la compréhension des marchés et réseaux criminels sur les plans stratégique, opérationnel et tactique. L'article illustre également comment le renseignement forensique peut soutenir des mesures préventives et peut contribuer à l'analyse des risques que posent les faux documents d'identité, voire à la remise en cause de la stratégie sécuritaire et de contrôle actuelle. L'approche proposée présente un carctère essentiellement générique puisque, à l'instar de l'exemple des faux documents d'identité, n'importe quel type de trace matérielle peut être traité systématiquement et scientifiquement de sorte à contribuer à la construction structurée de connaissances sur la criminalité et la sécurité.
Resumo:
Tässä kandidaatintyössä on esitelty U.S. NRC:n kehittämä TRAC/RELAP Advanced Computational Engine termohydrauliikkamallinnusohjelmisto sekä sillä luodun yksinkertaistetun painevesilaitoksen mallin pienimuotoinen simulointi.
Resumo:
In order to broaden our knowledge and understanding of the decision steps in the criminal investigation process, we started by evaluating the decision to analyse a trace and the factors involved in this decision step. This decision step is embedded in the complete criminal investigation process, involving multiple decision and triaging steps. Considering robbery cases occurring in a geographic region during a 2-year-period, we have studied the factors influencing the decision to submit biological traces, directly sampled on the scene of the robbery or on collected objects, for analysis. The factors were categorised into five knowledge dimensions: strategic, immediate, physical, criminal and utility and decision tree analysis was carried out. Factors in each category played a role in the decision to analyse a biological trace. Interestingly, factors involving information available prior to the analysis are of importance, such as the fact that a positive result (a profile suitable for comparison) is already available in the case, or that a suspect has been identified through traditional police work before analysis. One factor that was taken into account, but was not significant, is the matrix of the trace. Hence, the decision to analyse a trace is not influenced by this variable. The decision to analyse a trace first is very complex and many of the tested variables were taken into account. The decisions are often made on a case-by-case basis.
Resumo:
Human activities have serious impacts on marine apex predators. Inadequate knowledge of the spatial and trophic ecology of these marine animals ultimately compromises the viability of their populations and impedes our ability to use them as environmental biomonitors. Intrinsic biogeochemical markers, such as stable isotopes, fatty acids, trace elements, and chemical pollutants, are increasingly being used to trace the spatial and trophic ecology of marine top predators. Notable advances include the emergence of the first oceanographic"isoscapes" (isotopic geographic gradients), the advent of compound-specific isotopic analyses, improvements in diet reconstruction through Bayesian statistics, and tissue analysis of tracked animals to ground-truth biogeochemical profiles. However, most researchers still focus on only a few tracers. Moreover, insufficient knowledge of the biogeochemical integration in tissues, fractionation and routing processes, and geographic and temporal variability in baseline levels continue to hamper the resolution and potential of these markers in studying the spatial and feeding ecology of top predators.
Resumo:
A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status