956 resultados para TONIC VIBRATION REFLEX
Resumo:
PURPOSE: We hypothesize that untrained subjects can benefit from a greater cardiovascular stimulation than trained athletes, resembling classical aerobic-type activity, in addition to eliciting strength gains.METHODS: 3 groups of male subjects, inactive (SED), endurance trained (END) and strength trained (STR) underwent fitness (VO2max) and lower-body strength tests (isokinetic). Subjects were submitted to a session of oscillating VT, composed of 3 exercises (isometric half-squat, dynamic squat, dynamic squat with added load), each of 3 minutes duration, and repeated at 3 vibration frequencies (20, 26 and 32 Hz). VO2, heart rate and Borg scale were monitored.RESULTS: 27 healthy subjects (10 SED, 9 END and 8 STR), mean age 24.5 (SED), 25.0 (STR) and 29.8 (END) were included. VO2max was significantly different as expected (47.9 vs. 52.9 vs. 63.9 mL?min-1?kg-1, resp. for SED, STR and END). Isokinetic dominant leg extensors strength was higher in STR (3.32 N?m?kg-1 vs. 2.60 and 2.74 in SED and END). During VT, peak oxygen consumption (% of VO2max) attained was 59.3 in SED, 50.8 in STR and 48.0 in END (P<0.001 between SED and other subjects). Peak heart rate (% of heart rate max) was 82.7 in SED, 80.4 in STR and 72.4 in END. In SED, dynamic exercises without extra load elicited 51.0 % of VO2max and 72.1 % of heart rate max, and perceived effort reached 15.1/20.CONCLUSIONS: VT is an unconventional type of exercise, known to enhance strength, bone density, balance and flexibility. Users are attracted by the relative passivity. In SED, VT elicits sufficient cardiovascular response to benefit overall fitness in addition to the strength effects. VT's higher acceptance as an exercise in sedentary people, compared to jogging or cycling, can lead to better adherence to physical activity. Although long-term effects of VT on health are not available, we believe this type of mixed aerobic and resistance-type exercise can be beneficial on multiple health parameters, especially cardiovascular health.
Resumo:
In this paper, we describe several techniques for detecting tonic pitch value in Indian classical music. In Indian music, the raga is the basic melodic framework and it is built on the tonic. Tonic detection is therefore fundamental for any melodic analysis in Indian classical music. This workexplores detection of tonic by processing the pitch histograms of Indian classic music. Processing of pitch histograms using group delay functions and its ability to amplify certain traits of Indian music in the pitch histogram, is discussed. Three different strategies to detect tonic, namely, the concert method, the template matching and segmented histogram method are proposed. The concert method exploits the fact that the tonic is constant over a piece/concert.templatematchingmethod and segmented histogrammethodsuse the properties: (i) the tonic is always present in the background, (ii) some notes are less inflected and dominant, to detect the tonic of individual pieces. All the three methods yield good results for Carnatic music (90−100% accuracy), while for Hindustanimusic, the templatemethod works best, provided the v¯adi samv¯adi notes for a given piece are known (85%).
Resumo:
OBJECTIVE: To evaluate the dynamic properties of the horizontal vestibulo-ocular reflex (h-VOR) in the acute stage of two common labyrinthine diseases that provoke severe attacks of vertigo with spontaneous nystagmus: vestibular neuritis (vestibular loss alone) and viral labyrinthitis (cochleovestibular loss). MATERIAL AND METHODS: Sixty-three patients were investigated: 42 were diagnosed with vestibular neuritis and 21 with viral labyrinthitis. The h-VOR function was evaluated by conventional caloric and impulsive testing. A simplified model of vestibular function was used to analyze the vestibulo-ocular response to rotational stimulation. RESULTS: The results showed a significant difference in h-VOR characteristics between the two pathologies. Patients with vestibular neuritis exhibited a strong horizontal semicircular canal deficit, but no h-VOR asymmetry between the two rotational directions. In contrast, patients with viral labyrinthitis demonstrated moderate canal paresis and a marked h-VOR deficit in rotation toward the affected ear. CONCLUSION: These findings support the hypothesis that the h-VOR dynamic asymmetry that occurs after an acute unilateral inner ear lesion is not due to canal dysfunction alone, but involves complex adaptive changes in the central VOR that may implicate the otolith system. Based on histopathologic and clinical differences in the two pathologies reported in the literature, we postulate that this otolith-canal interaction is mainly linked to the loss of saccular function.
Resumo:
In this master's thesis a mechanical model that is driven with variable speed synchronous machine was developed. The developed mechanical model simulates the mechanics of power transmission and its torsional vibrations. The mechanical model was developed for the need of the branched mechanics of a rolling mill and the propulsion system of a tanker. First, the scope of the thesis was to clarify the concepts connected to the mechanical model. The clarified concepts are the variable speed drive, the mechanics of power transmission and the vibrationsin the power transmission. Next, the mechanical model with straight shaft line and twelve moments of inertia that existed in the beginning was developed to be branched considering the case of parallel machines and the case of parallel rolls. Additionally, the model was expanded for the need of moreaccurate simulation to up to thirty moments of inertia. The model was also enhanced to enable three phase short circuit situation of the simulated machine. After that the mechanical model was validated by comparing the results of the developed simulation tool to results of other simulation tools. The compared results are the natural frequencies and mode shapes of torsional vibration, the response of the load torque step and the stress in the mechanical system occurred by the permutation of the magnetic field that is arisen from the three phase short circuit situation. The comparisons were accomplished well and the mechanical model was validated for the compared cases. Further development to be made is to develop the load torque to be time-dependent and to install two frequency converters and two FEM modeled machines to be simulated parallel.
Resumo:
In order that the radius and thus ununiform structure of the teeth and otherelectrical and magnetic parts of the machine may be taken into consideration the calculation of an axial flux permanent magnet machine is, conventionally, doneby means of 3D FEM-methods. This calculation procedure, however, requires a lotof time and computer recourses. This study proves that also analytical methods can be applied to perform the calculation successfully. The procedure of the analytical calculation can be summarized into following steps: first the magnet is divided into slices, which makes the calculation for each section individually, and then the parts are submitted to calculation of the final results. It is obvious that using this method can save a lot of designing and calculating time. Thecalculation program is designed to model the magnetic and electrical circuits of surface mounted axial flux permanent magnet synchronous machines in such a way, that it takes into account possible magnetic saturation of the iron parts. Theresult of the calculation is the torque of the motor including the vibrations. The motor geometry and the materials and either the torque or pole angle are defined and the motor can be fed with an arbitrary shape and amplitude of three-phase currents. There are no limits for the size and number of the pole pairs nor for many other factors. The calculation steps and the number of different sections of the magnet are selectable, but the calculation time is strongly depending on this. The results are compared to the measurements of real prototypes. The permanent magnet creates part of the flux in the magnetic circuit. The form and amplitude of the flux density in the air-gap depends on the geometry and material of the magnetic circuit, on the length of the air-gap and remanence flux density of the magnet. Slotting is taken into account by using the Carter factor in the slot opening area. The calculation is simple and fast if the shape of the magnetis a square and has no skew in relation to the stator slots. With a more complicated magnet shape the calculation has to be done in several sections. It is clear that according to the increasing number of sections also the result will become more accurate. In a radial flux motor all sections of the magnets create force with a same radius. In the case of an axial flux motor, each radial section creates force with a different radius and the torque is the sum of these. The magnetic circuit of the motor, consisting of the stator iron, rotor iron, air-gap, magnet and the slot, is modelled with a reluctance net, which considers the saturation of the iron. This means, that several iterations, in which the permeability is updated, has to be done in order to get final results. The motor torque is calculated using the instantaneous linkage flux and stator currents. Flux linkage is called the part of the flux that is created by the permanent magnets and the stator currents passing through the coils in stator teeth. The angle between this flux and the phase currents define the torque created by the magnetic circuit. Due to the winding structure of the stator and in order to limit the leakage flux the slot openings of the stator are normally not made of ferromagnetic material even though, in some cases, semimagnetic slot wedges are used. In the slot opening faces the flux enters the iron almost normally (tangentially with respect to the rotor flux) creating tangential forces in the rotor. This phenomenon iscalled cogging. The flux in the slot opening area on the different sides of theopening and in the different slot openings is not equal and so these forces do not compensate each other. In the calculation it is assumed that the flux entering the left side of the opening is the component left from the geometrical centre of the slot. This torque component together with the torque component calculated using the Lorenz force make the total torque of the motor. It is easy to assume that when all the magnet edges, where the derivative component of the magnet flux density is at its highest, enter the slot openings at the same time, this will have as a result a considerable cogging torque. To reduce the cogging torquethe magnet edges can be shaped so that they are not parallel to the stator slots, which is the common way to solve the problem. In doing so, the edge may be spread along the whole slot pitch and thus also the high derivative component willbe spread to occur equally along the rotation. Besides forming the magnets theymay also be placed somewhat asymmetric on the rotor surface. The asymmetric distribution can be made in many different ways. All the magnets may have a different deflection of the symmetrical centre point or they can be for example shiftedin pairs. There are some factors that limit the deflection. The first is that the magnets cannot overlap. The magnet shape and the relative width compared to the pole define the deflection in this case. The other factor is that a shifting of the poles limits the maximum torque of the motor. If the edges of adjacent magnets are very close to each other the leakage flux from one pole to the other increases reducing thus the air-gap magnetization. The asymmetric model needs some assumptions and simplifications in order to limit the size of the model and calculation time. The reluctance net is made for symmetric distribution. If the magnets are distributed asymmetrically the flux in the different pole pairs will not be exactly the same. Therefore, the assumption that the flux flows from the edges of the model to the next pole pairs, in the calculation model from one edgeto the other, is not correct. If it were wished for that this fact should be considered in multi-pole pair machines, this would mean that all the poles, in other words the whole machine, should be modelled in reluctance net. The error resulting from this wrong assumption is, nevertheless, irrelevant.
Resumo:
This article describes the case of a 17-year-old adolescent boy who received a foot kick in the trunk area from an expert in karate. He presented with immediate cardiocirculatory arrest. After a prolonged resuscitation, he was transferred to a hospital where he died 5 days later without ever regaining consciousness. Postmortem investigations including autopsy, radiology, histology, toxicology, and postmortem chemistry were performed that showed signs of multiple organ failure, an acute hemorrhage in the region of the celiac plexus, and signs of medical resuscitation. No preexisting disease, particularly those concerning the heart, was objectified. The cause of death was attributed to multiple organ failure after a prolonged cardiocirculatory arrest. Concerning the origin of the cardiac arrest, 2 hypotheses were considered-a cardioinhibitory reflex and a cardiac contusion (commotio cordis). Because of the presence of traumatic lesions in the celiac plexus, the first hypothesis was finally submitted. This case is reported because rare cases of sudden death from celiac reflex are described in the literature where it is almost impossible to find references with accurate documentation. The presented case confirms the importance of detailed documentation of the circumstances and postmortem investigations to establish a diagnosis of death due to cardioinhibitory reflex.
Resumo:
[cat] La carpeta d'aprenentatge representa un punt de trobada dels grans temes que han ocupat la Didàctica d'ençà dels anys 90 del segle passat: el caràcter formatiu de l'avaluació, l'assumpte de les competències, la metacognició i el pensament crític de l'estudiant, el paper desenvolupat per les TIC, i la concepció d'un aprenentatge col·laboratiu i plantejat a llarg termini. En aquest article de revisió, hom estudia com aquests temes s'han concretat en la carpeta d'aprenentatge i n'han determinat la seva evolució. [eng] The learning portofolio represents a meeting point for the big questions than have concernend teaching since the 1990s: the formative character of the assessment, the issue of competencies, metacognition and the students's critical thinking, the role played by ICTs, and the idea of collaborative learning considered in the long term. The article looks at how these subjects have taken shape in the learning portofolio and how they have determinded its evolutin.
Resumo:
During the last decade, many studies have been carried out to understand the effects of focal vibratory stimuli at various levels of the central nervous system and to study pathophysiological mechanisms of neurological disorders as well as the therapeutic effects of focal vibration in neurorehabilitation. This review aimed to describe the effects of focal vibratory stimuli in neurorehabilitation including the neurological diseases or disorders like stroke, spinal cord injury, multiple sclerosis, Parkinson's' disease and dystonia. In conclusion, focal vibration stimulation is well tolerated, effective and easy to use, and it could be used to reduce spasticity, to promote motor activity and motor learning within a functional activity, even in gait training, independent from etiology of neurological pathology. Further studies are needed in the future well- designed trials with bigger sample size to determine the most effective frequency, amplitude and duration of vibration application in the neurorehabilitation.
Resumo:
Appearance of the vibration is the very important problem in long tool turning and milling. Current solutions of minimizing vibrations provided by different tool suppliers are very expensive. This Master’s Thesis is presenting the new type of vibration free machining tools produced by Konepaja ASTEX Gear Oy that have cheaper production costs compare to competitors’ products. Vibration problems in machining and their today’s solutions are analyzed in this work. The new vibration damping invention is presented and described. Moreover, the production, laboratory experimental modal analysis and practical testing of the new vibration free prototypes are observed and analyzed on the pages of this Thesis. Based on the testing results the new invention is acknowledged to be successful and approved for further studies and developments.
Resumo:
The vibration during transportation is one of the main causes of fruit damage. The actual methodologies used for damage evaluation in fruits seem to be subjective, since most of them are based on visual evaluation. In this study the effect of vibration, for one and two hours, on polyphenoloxidase (PPO) activity in peach pulp was investigated. The relation among PPO activity variation, postharvest time and resting time were also considered. Results showed that vibration affects PPO activity. However, it was not possible to correlate PPO activity variation and vibration.
Resumo:
Large amplitude bus bar aeolian vibration may lead to post insulator damage. Different damping applications are used to decrease the risk of large amplitude aeolian vibration. In this paper the post insulator load caused by the bus bar aeolian vibration and the effect of damping methods are evaluated. The effects of three types of bus bar connectors and three types of primary structures are studied. Two actual damping devices, damping cable and their combinations are studied. The post insulator loads are studied with strain gage based custom made force sensors installed on the both ends of the post insulator and with the displacement sensor installed on the midpoint of the bus bar. The post insulator loads are calculated from the strain values and the damping properties are determined from the displacement history. The bus bar is deflected with a hanging weight. The weight is released and the bus bar is left to free damped vibration. Both actual bus bar vibration dampers RIBE and SBI were very effective against the aeolian vibration. Combining vibration damper with damping cable will increase the damping ratio but it may be unnecessary considering the extra effort. Bus bar connector type or primary structure have no effect on the vertical load. The bending moment at the post insulator with double sided bus bar connector is significantly higher than at the post insulator with single sided bus bar connector. No reliable conclusions about bus bar connector type effect can be done, but the roller bearing type or central bearing type connector may reduce the bending moment. The RHS steel frame as primary structure may increase the bending moment peak values since it is the least rigid primary structure type and it may start to vibrate as a response to the awakening force of the vibrating bus bar.
Resumo:
This paper investigates defect detection methodologies for rolling element bearings through vibration analysis. Specifically, the utility of a new signal processing scheme combining the High Frequency Resonance Technique (HFRT) and Adaptive Line Enhancer (ALE) is investigated. The accelerometer is used to acquire data for this analysis, and experimental results have been obtained for outer race defects. Results show the potential effectiveness of the signal processing technique to determine both the severity and location of a defect. The HFRT utilizes the fact that much of the energy resulting from a defect impact manifests itself in the higher resonant frequencies of a system. Demodulation of these frequency bands through use of the envelope technique is then employed to gain further insight into the nature of the defect while further increasing the signal to noise ratio. If periodic, the defect frequency is then present in the spectra of the enveloped signal. The ALE is used to enhance the envelope spectrum by reducing the broadband noise. It provides an enhanced envelope spectrum with clear peaks at the harmonics of a characteristic defect frequency. It is implemented by using a delayed version of the signal and the signal itself to decorrelate the wideband noise. This noise is then rejected by the adaptive filter that is based upon the periodic information in the signal. Results have been obtained for outer race defects. They show the effectiveness of the methodology to determine both the severity and location of a defect. In two instances, a linear relationship between signal characteristics and defect size is indicated.
Resumo:
This paper examines two passive techniques for vibration reduction in mechanical systems: the first one is based on dynamic vibration absorbers (DVAs) and the second uses resonant circuit shunted (RCS) piezoceramics. Genetic algorithms are used to determine the optimal design parameters with respect to performance indexes, which are associated with the dynamical behavior of the system over selected frequency bands. The calculation of the frequency response functions (FRFs) of the composite structure (primary system + DVAs) is performed through a substructure coupling technique. A modal technique is used to determine the frequency response function of the structure containing shunted piezoceramics which are bonded to the primary structure. The use of both techniques simultaneously on the same structure is investigated. The methodology developed is illustrated by numerical applications in which the primary structure is represented by simple Euler-Bernoulli beams. However, the design aspects of vibration control devices presented in this paper can be extended to more complex structures.