998 resultados para TISSUE DOPPLER VELOCITY
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia cardiovascular
Resumo:
INTRODUCTION: The significant risk of sudden arrhythmic death in patients with congestive heart failure and electromechanical ventricular dyssynchrony has led to increased use of combined cardiac resynchronization therapy defibrillator (CRT-D) devices. OBJECTIVES: To evaluate the echocardiographic variables in patients undergoing CRT-D that predict the occurrence of appropriate therapies (AT) for ventricular tachyarrhythmia. METHODS: We analyzed 38 consecutive patients (mean age 60 +/- 12 years, 63% male) with echocardiographic evaluation before and 6 months after CRT-D implantation. Patients with AT were identified in a mean follow-up of 471 +/- 323 days. A standard echocardiographic study was performed including tissue Doppler imaging (TDI). Responders were defined as patients with improvement in NYHA class of < or = 1 in the first six months, and reverse remodeling as a decrease in left ventricular end-systolic volume of < or = 15% and/or an increase in left ventricular ejection fraction of > 25%. RESULTS: The responder rate was 74%, and the reverse remodeling rate was 55%. AT occurred in 21% of patients, who presented with greater left ventricular end-diastolic internal diameter (LVEDD) before implantation (86 +/- 8 vs. 76 +/- 11 mm, p = 0.03) and at 6 months (81 +/- 8 vs. 72 +/- 14 mm, p = 0.08), and increased left ventricular end-systolic internal diameter (66 +/- 14 vs. 56 +/- 14 mm, p = 0.03) and lower ejection fraction (24 +/- 6 vs. 34 +/- 14%, p = 0.08) at 6 months. In the group with AT, the responder rate was lower (38 vs. 83%, p = 0.03), without significant differences in reverse remodeling (38% for the AT group vs. 60%, p = 0.426) or in the other variables. By univariate analysis, predictors of AT were LVEDD before implantation and E' after implantation. Age, gender, ischemic etiology, use of antiarrhythmic drugs, reverse remodeling and the other echocardiographic parameters did not predict AT. In multivariate logistic regression analysis, both LVEDD before implantation (OR 1.24, 95% CI 1.04-1.48, p = 0.019) and postimplantation E' (OR 0.27, 95% CI 0.09-0.76, p = 0.014) remained as independent predictors of AT. CONCLUSIONS: In patients undergoing CRT-D, episodes of ventricular tachyarrhythmia occur with high incidence, independently of echocardiographic response, with LVEDD before implantation and E' after implantation as the only independent predictors of AT in the medium-term. These results highlight the importance of combined devices with defibrillation capability.
Resumo:
Diagnosis, prognosis and evaluation of death risk in Chagas cardiomyopathy still constitute a challenge due to the diversity of manifestations, which determine the importance of using echocardiography, tissue Doppler and biomarkers. To evaluate, within a systematic review, clinical and echocardiographic profiles of patients with chronic chagasic cardiomyopathy, which may be related to worse prognosis and major mortality risk. To perform the systematic review, we used Medline (via PubMed), LILACS and SciELO databases to identify 82 articles published from 1991 to 2012, with the following descriptors: echocardiography, mortality and Chagas disease. We selected 31 original articles, involving diagnostic and prognostic methods. The importance of Chagas disease has increased due to its emergence in Europe and United States, but most evidence came from Brazil. Among the predictors of worse prognosis and higher mortality risk are morphological and functional alterations in the left and right ventricles, evaluated by conventional echocardiography and tissue Doppler, as well as the increase in brain natriuretic peptide and troponin I concentrations. Recently, the evaluations of dyssynchrony, dysautonomia, as well as strain, strain rate and myocardial twisting were added to the diagnostic arsenal for the early differentiation of Chagas cardiomyopathy. Developments in imaging and biochemical diagnostic procedures have enabled more detailed cardiac evaluations, which demonstrate the early involvement of both ventricles, allowing a more accurate assessment of the mortality risk in Chagas disease.
Resumo:
Background: Heart failure with preserved ejection fraction (HFPEF) is the most common form of heart failure (HF), its diagnosis being a challenge to the outpatient clinic practice. Objective: To describe and compare two strategies derived from algorithms of the European Society of Cardiology Diastology Guidelines for the diagnosis of HFPEF. Methods: Cross-sectional study with 166 consecutive ambulatory patients (67.9±11.7 years; 72% of women). The strategies to confirm HFPEF were established according to the European Society of Cardiology Diastology Guidelines criteria. In strategy 1 (S1), tissue Doppler echocardiography (TDE) and electrocardiography (ECG) were used; in strategy 2 (S2), B-type natriuretic peptide (BNP) measurement was included. Results: In S1, patients were divided into groups based on the E/E'ratio as follows: GI, E/E'> 15 (n = 16; 9%); GII, E/E'8 to 15 (n = 79; 48%); and GIII, E/E'< 8 (n = 71; 43%). HFPEF was confirmed in GI and excluded in GIII. In GII, TDE [left atrial volume index (LAVI) ≥ 40 mL/m2; left ventricular mass index LVMI) > 122 for women and > 149 g/m2 for men] and ECG (atrial fibrillation) parameters were assessed, confirming HFPEF in 33 more patients, adding up to 49 (29%). In S2, patients were divided into three groups based on BNP levels. GI (BNP > 200 pg/mL) consisted of 12 patients, HFPEF being confirmed in all of them. GII (BNP ranging from 100 to 200 pg/mL) consisted of 20 patients with LAVI > 29 mL/m2, or LVMI ≥ 96 g/m2 for women or ≥ 116 g/m2 for men, or E/E'≥ 8 or atrial fibrillation on ECG, and the diagnosis of HFPEF was confirmed in 15. GIII (BNP < 100 pg/mL) consisted of 134 patients, 26 of whom had the diagnosis of HFPEF confirmed when GII parameters were used. Measuring BNP levels in S2 identified 4 more patients (8%) with HFPEF as compared with those identified in S1. Conclusion: The association of BNP measurement and TDE data is better than the isolated use of those parameters. BNP can be useful in identifying patients whose diagnosis of HF had been previously excluded based only on TDE findings.
Resumo:
Background:Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process.Objective:To evaluate the impact of AF ablation on estimated LV filling pressure.Methods:A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation.Results:One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001).Conclusion:Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure.
Resumo:
Background:Chagas disease is a cause of dilated cardiomyopathy, and information about left atrial (LA) function in this disease still lacks.Objective:To assess the different LA functions (reservoir, conduit and pump functions) and their correlation with the echocardiographic parameters of left ventricular (LV) systolic and diastolic functions.Methods:10 control subjects (CG), and patients with Chagas disease as follows: 26 with the indeterminate form (GI); 30 with ECG alterations (GII); and 19 with LV dysfunction (GIII). All patients underwent M-mode and two-dimensional echocardiography, pulsed-wave Doppler and tissue Doppler imaging.Results:Reservoir function (Total Emptying Fraction: TEF): (p <0.0001), lower in GIII as compared to CG (p = 0.003), GI (p <0.001) and GII (p <0.001). Conduit function (Passive Emptying Fraction: PEF): (p = 0.004), lower in GIII (GIII and CG, p = 0.06; GI and GII, p = 0.06; and GII and GIII, p = 0.07). Pump function (Active Emptying Fraction: AEF): (p = 0.0001), lower in GIII as compared to CG (p = 0.05), GI (p<0.0001) and GII (p = 0.002). There was a negative correlation of E/e’average with the reservoir and pump functions (TEF and AEF), and a positive correlation of e’average with s’ wave (both septal and lateral walls) and the reservoir, conduit and pump LA functions.Conclusion:An impairment of LA functions in Chagas cardiomyopathy was observed.
Resumo:
Background:Left atrial volume (LAV) is a predictor of prognosis in patients with heart failure.Objective:We aimed to evaluate the determinants of LAV in patients with dilated cardiomyopathy (DCM).Methods:Ninety patients with DCM and left ventricular (LV) ejection fraction ≤ 0.50 were included. LAV was measured with real-time three-dimensional echocardiography (eco3D). The variables evaluated were heart rate, systolic blood pressure, LV end-diastolic volume and end-systolic volume and ejection fraction (eco3D), mitral inflow E wave, tissue Doppler e´ wave, E/e´ ratio, intraventricular dyssynchrony, 3D dyssynchrony index and mitral regurgitation vena contracta. Pearson´s coefficient was used to identify the correlation of the LAV with the assessed variables. A multiple linear regression model was developed that included LAV as the dependent variable and the variables correlated with it as the predictive variables.Results:Mean age was 52 ± 11 years-old, LV ejection fraction: 31.5 ± 8.0% (16-50%) and LAV: 39.2±15.7 ml/m2. The variables that correlated with the LAV were LV end-diastolic volume (r = 0.38; p < 0.01), LV end-systolic volume (r = 0.43; p < 0.001), LV ejection fraction (r = -0.36; p < 0.01), E wave (r = 0.50; p < 0.01), E/e´ ratio (r = 0.51; p < 0.01) and mitral regurgitation (r = 0.53; p < 0.01). A multivariate analysis identified the E/e´ ratio (p = 0.02) and mitral regurgitation (p = 0.02) as the only independent variables associated with LAV increase.Conclusion:The LAV is independently determined by LV filling pressures (E/e´ ratio) and mitral regurgitation in DCM.
Resumo:
AbstractIn children with structural congenital heart disease (CHD), the effects of chronic ventricular pacing on diastolic function are not well known. On the other hand, the beneficial effect of septal pacing over apical pacing is still controversial.The aim of this study was to evaluate the influence of different right ventricular (RV) pacing site on left ventricular (LV) diastolic function in children with cardiac defects.Twenty-nine pediatric patients with complete atrioventricular block (CAVB) and CHD undergoing permanent pacing were prospectively studied. Pacing sites were RV apex (n = 16) and RV septum (n = 13). Echocardiographic assessment was performed before pacemaker implantation and after it, during a mean follow‑up of 4.9 years.Compared to RV septum, transmitral E-wave was significantly affected in RV apical pacing (95.38 ± 9.19 vs 83 ± 18.75, p = 0.038). Likewise, parameters at the lateral annular tissue Doppler imaging (TDI) were significantly affected in children paced at the RV apex. The E´ wave correlated inversely with TDI lateral myocardial performance index (Tei index) (R2= 0.9849, p ≤ 0.001). RV apex pacing (Odds ratio, 0.648; confidence interval, 0.067-0.652; p = 0.003) and TDI lateral Tei index (Odds ratio, 31.21; confidence interval, 54.6-177.4; p = 0.025) predicted significantly decreased LV diastolic function.Of the two sites studied, RV septum prevents pacing-induced reduction of LV diastolic function.
Resumo:
This paper proposes MSISpIC, a probabilistic sonar scan matching algorithm for the localization of an autonomous underwater vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), the robot displacement estimated through dead-reckoning using a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method is an extension of the pIC algorithm. An extended Kalman filter (EKF) is used to estimate the robot-path during the scan in order to reference all the range and bearing measurements as well as their uncertainty to a scan fixed frame before registering. The major contribution consists of experimentally proving that probabilistic sonar scan matching techniques have the potential to improve the DVL-based navigation. The algorithm has been tested on an AUV guided along a 600 m path within an abandoned marina underwater environment with satisfactory results
Resumo:
Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.
Resumo:
AIMS: The aim of this study was to investigate the heritability as well as genetic and environmental correlations of left ventricular (LV) structural and functional traits in complex pedigrees of a Caucasian population. METHODS AND RESULTS: We randomly recruited 459 white European subjects from 52 families (50% women; mean age 45 years). LV structure was measured by M-mode and 2D echocardiography and LV function was measured by conventional Doppler and tissue Doppler imaging (TDI). Other measurements included blood pressure, anthropometric, and biochemical measurements. We estimated the heritability of LV traits while adjusting for covariables, including sex, age, body height and weight, systolic and diastolic blood pressures, and heart rate. With full adjustment, heritability of LV mass was 0.23 (P= 0.025). The TDI-derived mitral annular velocities Ea and Aa showed moderate heritability (h(2)= 0.36 and 0.53, respectively), whereas the mitral inflow A peak had weak heritability (h(2) = 0.25) and the E peak was not heritable (h(2) = 0.11). We partitioned the total phenotypic correlation when it reached significance, into a genetic and an environmental component. The genetic correlations were 0.61 between the E and Ea peaks and 0.90 between the A and Aa peaks. CONCLUSION: Our study demonstrated moderate heritability for LV mass as well as the mitral annular Ea and Aa peaks. We also found significant genetic correlations between the E and Ea peaks and between the A and Aa peaks. Our current findings support the ongoing research to map and detect genetic variants that contribute to the variation in LV mass and other LV structural and functional phenotypes.
Resumo:
This paper compares two well known scan matching algorithms: the MbICP and the pIC. As a result of the study, it is proposed the MSISpIC, a probabilistic scan matching algorithm for the localization of an Autonomous Underwater Vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), and the robot displacement estimated through dead-reckoning with the help of a Doppler Velocity Log (DVL) and a Motion Reference Unit (MRU). The proposed method is an extension of the pIC algorithm. Its major contribution consists in: 1) using an EKF to estimate the local path traveled by the robot while grabbing the scan as well as its uncertainty and 2) proposing a method to group into a unique scan, with a convenient uncertainty model, all the data grabbed along the path described by the robot. The algorithm has been tested on an AUV guided along a 600m path within a marina environment with satisfactory results
Resumo:
This paper proposes a pose-based algorithm to solve the full SLAM problem for an autonomous underwater vehicle (AUV), navigating in an unknown and possibly unstructured environment. The technique incorporate probabilistic scan matching with range scans gathered from a mechanical scanning imaging sonar (MSIS) and the robot dead-reckoning displacements estimated from a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method utilizes two extended Kalman filters (EKF). The first, estimates the local path travelled by the robot while grabbing the scan as well as its uncertainty and provides position estimates for correcting the distortions that the vehicle motion produces in the acoustic images. The second is an augment state EKF that estimates and keeps the registered scans poses. The raw data from the sensors are processed and fused in-line. No priory structural information or initial pose are considered. The algorithm has been tested on an AUV guided along a 600 m path within a marina environment, showing the viability of the proposed approach
Resumo:
Osteoprotegerin (OPG) regulates bone mass by inhibiting osteoclast differentiation and activation, and plays a role in vascular calcification. We evaluated the relationship between osteoprotegerin levels and inflammatory markers, atherosclerosis, and mortality in patients with stages 3-5 chronic kidney disease. A total of 145 subjects (median age 61 years, 61% men; 36 patients on hemodialysis, 55 patients on peritoneal dialysis, and 54 patients with stages 3-5 chronic kidney disease) were studied. Clinical characteristics, markers of mineral metabolism (including fibroblast growth factor-23 [FGF-23]) and inflammation (high-sensitivity C-reactive protein [hsCRP] and interleukin-6 [IL-6]), and the intima-media thickness (IMT) in the common carotid arteries were measured at baseline. Cardiac function was assessed by color tissue Doppler echocardiography. After 36 months follow-up, the survival rate by Kaplan-Meier analysis was significantly different according to OPG levels (χ2=14.33; P=0.002). Increased OPG levels were positively associated with IL-6 (r=0.38, P<0.001), FGF-23 (r=0.26, P<0.001) and hsCRP (r=0.0.24, P=0.003). In addition, OPG was positively associated with troponin I (r=0.54, P<0.001) and IMT (r=0.39, P<0.0001). Finally, in Cox analysis, only OPG (HR=1.07, 95%CI=1.02-1.13) and hsCRP (HR=1.02, 95%CI=1.01-1.04) were independently associated with increased risk of death. These results suggested that elevated levels of serum OPG might be associated with atherosclerosis and all-cause mortality in patients with chronic kidney disease.
Resumo:
This paper proposes MSISpIC, a probabilistic sonar scan matching algorithm for the localization of an autonomous underwater vehicle (AUV). The technique uses range scans gathered with a Mechanical Scanning Imaging Sonar (MSIS), the robot displacement estimated through dead-reckoning using a Doppler velocity log (DVL) and a motion reference unit (MRU). The proposed method is an extension of the pIC algorithm. An extended Kalman filter (EKF) is used to estimate the robot-path during the scan in order to reference all the range and bearing measurements as well as their uncertainty to a scan fixed frame before registering. The major contribution consists of experimentally proving that probabilistic sonar scan matching techniques have the potential to improve the DVL-based navigation. The algorithm has been tested on an AUV guided along a 600 m path within an abandoned marina underwater environment with satisfactory results