894 resultados para TEFL devices
Resumo:
MRI visualization of devices is traditionally based on signal loss due to T(2)* effects originating from local susceptibility differences. To visualize nitinol devices with positive contrast, a recently introduced postprocessing method is adapted to map the induced susceptibility gradients. This method operates on regular gradient-echo MR images and maps the shift in k-space in a (small) neighborhood of every voxel by Fourier analysis followed by a center-of-mass calculation. The quantitative map of the local shifts generates the positive contrast image of the devices, while areas without susceptibility gradients render a background with noise only. The positive signal response of this method depends only on the choice of the voxel neighborhood size. The properties of the method are explained and the visualizations of a nitinol wire and two stents are shown for illustration.
Resumo:
Nowadays, there are several services and applications that allow users to locate and move to different tourist areas using a mobile device. These systems can be used either by internet or downloading an application in concrete places like a visitors centre. Although such applications are able to facilitate the location and the search for points of interest, in most cases, these services and applications do not meet the needs of each user. This paper aims to provide a solution by studying the main projects, services and applications, their routing algorithms and their treatment of the real geographical data in Android mobile devices, focusing on the data acquisition and treatment to improve the routing searches in off-line environments.
Resumo:
In this work, we have developed the first free software for mobile devices with the Android operating system that can preventively mitigate the number of contagions of sexually transmitted infections (STI), associated with risk behavior. This software runs in two modes. The normal mode allows the user to see the alerts and nearby health centers. The second mode enables the service to work in the background. This software reports the health risks, as well as the location of different test centers.
Resumo:
Percutaneous closure of patent foramen ovale (PFO) has been proposed as the treatment of choice for young high-risk patients who suffered cryptogenic stroke and/or peripheral paradoxical embolism. We sought to compare prospectively two different devices used for percutaneous PFO closure.Prospective data were collected on 40 high risk patients (females: 38%, mean age : 44 +/- 11 years, interatrial septal aneurysm >10 mm: 68%) who underwent percutaneous PFO closure after cryptogenic stroke (n = 38) or peripheral paradoxical embolism (n = 2). Chronologically, 20 patients were first treated by a PFO-Star (Cardia, Burnsville, MI) device. Then, 20 other patients received a Starflex occluder (NMT, Boston, MA). The primary endpoint was complete PFO closure at 6 months as assessed by transthoracic contrast echocardiography. Secondary endpoints were major peri- or post procedural complications and clinical recurrence at 1 year follow-up.Baseline clinical and anatomical characteristics were comparable for both groups. Complete PFO closure was observed in 50% (PFO-Star) and 90% (Starflex) of patients (p=0.001) respectively. Major peri-procedural complications occurred in the PFO-star group only: right-sided device thrombus (1 patient) and aorto-right atrial fistula (1 patient). At 1 year follow-up, no clinical recurrence occurred.In conclusion, despite the absence of clinical recurrence in this high-risk population with presumed paradoxical embolism, complete PFO closure at 6 months follow-up was significantly related to the type of closure device used
Resumo:
This paper describes a systematic research about free software solutions and techniques for art imagery computer recognition problem.
Resumo:
Intrauterine devices (IUDs), long-acting and reversible contraceptives, induce a number of immunological and biochemical changes in the uterine environment that could affect endometrial cancer (EC) risk. We addressed this relationship through a pooled analysis of data collected in the Epidemiology of Endometrial Cancer Consortium. We combined individual-level data from 4 cohort and 14 case-control studies, in total 8,801 EC cases and 15,357 controls. Using multivariable logistic regression, we estimated pooled odds ratios (pooled-ORs) and 95% confidence intervals (CIs) for EC risk associated with ever use, type of device, ages at first and last use, duration of use and time since last use, stratified by study and adjusted for confounders. Ever use of IUDs was inversely related to EC risk (pooled-OR = 0.81, 95% CI = 0.74-0.90). Compared with never use, reduced risk of EC was observed for inert IUDs (pooled-OR = 0.69, 95% CI = 0.58-0.82), older age at first use (≥35 years pooled-OR = 0.53, 95% CI = 0.43-0.67), older age at last use (≥45 years pooled-OR = 0.60, 95% CI = 0.50-0.72), longer duration of use (≥10 years pooled-OR = 0.61, 95% CI = 0.52-0.71) and recent use (within 1 year of study entry pooled-OR = 0.39, 95% CI = 0.30-0.49). Future studies are needed to assess the respective roles of detection biases and biologic effects related to foreign body responses in the endometrium, heavier bleeding (and increased clearance of carcinogenic cells) and localized hormonal changes.
Resumo:
This project analyses WiFiSLAM, an indoor positioning system for mobile phones that tries to estimate the position by analysing WiFi signals.
Resumo:
PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.
Resumo:
BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.
Resumo:
It is commonly regarded that the overuse of traffic control devices desensitizes drivers and leads to disrespect, especially for low-volume secondary roads with limited enforcement. The maintenance of traffic signs is also a tort liability concern, exacerbated by unnecessary signs. The Federal Highway Administration’s (FHWA) Manual on Uniform Traffic Control Devices (MUTCD) and the Institute of Transportation Engineer’s (ITE) Traffic Control Devices Handbook provide guidance for the implementation of STOP signs based on expected compliance with right-of-way rules, provision of through traffic flow, context (proximity to other controlled intersections), speed, sight distance, and crash history. The approach(es) to stop is left to engineering judgment and is usually dependent on traffic volume or functional class/continuity of system. Although presently being considered by the National Committee on Traffic Control Devices, traffic volume itself is not given as a criterion for implementation in the MUTCD. STOP signs have been installed at many locations for various reasons which no longer (or perhaps never) met engineering needs. If in fact the presence of STOP signs does not increase safety, removal should be considered. To date, however, no guidance exists for the removal of STOP signs at two-way stop-controlled intersections. The scope of this research is ultra-low-volume (< 150 daily entering vehicles) unpaved intersections in rural agricultural areas of Iowa, where each of the 99 counties may have as many as 300 or more STOP sign pairs. Overall safety performance is examined as a function of a county excessive use factor, developed specifically for this study and based on various volume ranges and terrain as a proxy for sight distance. Four conclusions are supported: (1) there is no statistical difference in the safety performance of ultra-low-volume stop-controlled and uncontrolled intersections for all drivers or for younger and older drivers (although interestingly, older drivers are underrepresented at both types of intersections); (2) compliance with stop control (as indicated by crash performance) does not appear to be affected by the use or excessive use of STOP signs, even when adjusted for volume and a sight distance proxy; (3) crash performance does not appear to be improved by the liberal use of stop control; (4) safety performance of uncontrolled intersections appears to decline relative to stop-controlled intersections above about 150 daily entering vehicles. Subject to adequate sight distance, traffic professionals may wish to consider removal of control below this threshold. The report concludes with a section on methods and legal considerations for safe removal of stop control.
Resumo:
BACKGROUND: Closures of atrial septal defects or a patent foramen ovale (PFO) are increasingly performed percutaneously. The experience of late migration of a new bio-absorbable device is presented here, followed by conceptual discussion. METHODS: Six months post PFO closure with a BioSTAR® device a patient presented with chest pain. Echocardiography showed a hyperechogenic structure perforating the aortic wall. RESULTS: Surgical exploration showed a perforation of the ascending aorta by one metallic, non absorbable arm. This is the second case of late (>6 months) dislocation of the residual framework of the occluder. CONCLUSIONS: The overall incidence of perforation of cardiac structures due to secondary dislocation is low. However this complication exists and should kept in mind in symptomatic patients with new onset of chest pain, after percutaneous procedures. The concept of biodegradation, with residual, non absorbable metal braiding, should be reviewed, analyzing in particular long term results and incidence of secondary dislocation.
Resumo:
AbstractOBJECTIVETo analyze the care implemented by the nursing team to promote the safety of adult patients and prevention of skin and mucosal lesions associated with the presence of lower airways invasive devices.METHODStudy with qualitative and quantitative approach, descriptive and exploratory type, whose investigative scenarios were adult inpatient units of a hospital in the West Frontier of Rio Grande do Sul. The study subjects consisted of nurses, nursing technicians and nursing assistants.RESULTSA total of 118 professionals were interviewed. We highlight the observed specific care with endotracheal tube and tracheostomy, management and assessment of the cuff and the criteria used to secretion aspiration.CONCLUSIONThere is a superficial nursing work in the patient direct care and a differentiation in relation to the perception of nurse technicians, especially those working in the intensive care unit, who presented major property and view of the patient's clinical status.
Resumo:
BACKGROUND: Totally implanted vascular access devices are frequently used in children for repeated blood samples or intravenous treatments. This prospective study aims at identifying the risk factors associated with infections, obstructions and surgical complications of these devices in pediatric patients. METHODS: From January 2006 to January 2008, all children older than one year of age with a diagnosis of solid or blood cell malignancy were included in the study. Insertion was performed by the surgeon according to a standardized protocol after landmark-guided puncture of the subclavian or internal jugular vein by a senior anesthesiologist. Dressing and post-operative care were standardized. Every manipulation was prospectively recorded by specialized dedicated nurses, and all patients were screened for complications one month post-surgery. RESULTS: 45 consecutive patients 1 to 16 years old were enrolled in the study. Mean age at the time of procedure was 8.5 years (range 1.3-15.6; SD +/- 4.88). There were 12 peroperative adverse events in 45 procedures (27%), detailed as follows: 3 pneumothoraces (7%), 3 hematomas (7%), 6 arterial punctures (13%). Among these events, intervention was necessary for two pneumothorax and one arterial puncture. There was no air embolism. At one month, we recorded 5 post-operative complications (11%): 2 thrombotic obstructions, one unsightly scar, and one scapular pain of unknown etiology. One patient needed repositioning of the catheter. There was no catheter-related infection. CONCLUSION: Prospective recording of TIVA insertion in children reveals a significant number of early incidents and complications, mainly associated with the percutaneous puncture technique. We found no infection in this series. Results of a longer follow-up in the same population are pending.
Resumo:
We propose a method to estimate time invariant cyclical DSGE models using the informationprovided by a variety of filters. We treat data filtered with alternative procedures as contaminated proxies of the relevant model-based quantities and estimate structural and non-structuralparameters jointly using a signal extraction approach. We employ simulated data to illustratethe properties of the procedure and compare our conclusions with those obtained when just onefilter is used. We revisit the role of money in the transmission of monetary business cycles.