918 resultados para Systems integration


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nowadays web services technology is widely used to integrate heterogeneous systems and develop new applications. In this paper, an application of integration of hotel management systems by web services technology is presented. The Group Hotel Integration Reservation System (GHIRS) integrates lots of systems of hotel industry such as Front Office system, Property Management system, Enterprise Information System (EIS), Enterprise Information Portal system (EIP), Customer Relationship Management system (CRM) and Supply Chain Management system (SCM) together. This integration solution can add or expand hotel software system in any size of hotel chains environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a system of systems approach to threat detection through integration of heterogeneous independently operable systems. The approach is presented on a realistic situation where a human-controlled base robot, swarm robot(s), and sensors work together to obtain a decision about a possible threat in the environment. The base robot is remotely operated by a human using a haptic control system. The swarm robot(s) are autonomous and can accept directives from the base robot. Finally, sensors directly communicate with (report to) the base robot. In this scenario, heterogeneous systems and human interact in a system of systems architecture. With the inclusion of human expert and sensor verification of swarm robots, the system can successfully perform the threat detection and reduce the false alarms. Finally, a system of systems simulation framework including a base robot, a swarm robot, and two sensors is presented in addition to an experimental evaluation of the proposed SoS architecture

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The advancement in solar photovoltaic (PV) technology, the cost and efficiency of PVs have encouraged users worldwide to adopt more and more PVs as it is free from greenhouse gas emissions and unlimited in nature. Integration of roof-top solar PV systems is currently emerging rapidly in Australia as the governments are giving attractive incentives and encouraging households to build a sustainable climate-friendly society for the future. The key major barriers to the integration of roof-top solar PV systems are the uncertainties in the performance of the low voltage distribution network due to the intermittent nature of solar PV sources. In this paper, a model was developed to investigate the potential technical impacts of integrating roof-top solar PV systems into the low voltage distribution network in a subtropical climate. The results show that integration of roof-top solar PV in the customer premises causes uncertainties such as voltage fluctuations, phase unbalance, distribution transformer overloading, reactive power compensation, and harmonic injections that detract the overall power quality of the typical distribution network. © 2014 AIP Publishing LLC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Organizations often operate in turbulent environments characterized by intense competitiveness, constant technological progress, new market requirements, and scarce natural resources. This scenario imposes the constant need for change in the operation and companies' management. The integration of certifiable management systems is an effective alternative in this sense. The objective of the present study is to propose guidelines for the integration of the ISO 9001 Quality Management System (QMS), ISO 14001 Environmental Management System (EMS) and OHSAS 18001 Occupational Health and Safety Management System (OHSMS) in industrial companies. These guidelines were developed based on a theoretical framework and on the results from fourteen case studies performed in Brazilian industrial companies. The proposed guidelines were divided into three phases: A) integration planning, b) integration development, and c) integration control and improvement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

For over a quarter of a century, the Economic Commission for Latin America and the Caribbean (ECLAC) has been in the vanguard of the search for greater physical integration among South American countries, especially in the area of transport, including road, rail, river and multimodal transport.Its activities in this field have ranged from drafting agreements to the design and introduction of concrete measures and have been carried out, either individually, at the request of the Governments of member States, or in collaboration with other organizations, such as the Institute for the Integration of Latin America and the Caribbean (INTAL), which is part of the Inter-American Development Bank (IDB).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This edition of the Bulletin highlights sections of a recent study carried out by the Transport Unit of ECLAC on behalf of the Institute for Latin American Integration (INTAL) entitled Physical Integration of Mercosur-Bolivia- Chile-Peru: the potential contribution of the railway systems. One of the conclusions stresses the need for the railway and other companies involved in the construction of any major project to sign formal agreements relating to the allocation of freight, track utilization fees and other factors on which operation of the railway to be constructed will depend.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This progress report is an introduction to a study to evaluate the incorporation of rotational pasturing systems into cattle finishing programs. Because the first year is still in progress and the first trial is not complete, few data are available. However, there is a suggestion that feeding an ionophore to young calves on pasture may result in improved daily gains.