895 resultados para Swan Ganz catheter
Resumo:
The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.
Resumo:
The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance catheter (CC). Sprague-Dawley rats with left anterior descending coronary artery ligation (MI group, n = 9) were compared with a sham-operated control group (n = 10) without MI. Transthoracic echocardiography (TTE) was performed every 2 wk over an 8-wk period, after which classic TTE parameters, especially MPI and LVFS/MPI, were compared with invasive indexes obtained by using a CC. Serial TTE data showed significant alterations in the majority of the noninvasive functional and structural parameters (classic and novel) studied in the presence of MI. Both MPI and LVFS/MPI significantly (P < 0.05 for all reported values) correlated with body weight (r = -0.58 and 0.76 for MPI and LVFS/MPI, respectively), preload recruitable stroke work (r = -0.61 and 0.63), LV end-diastolic pressure (LVEDP) (r = 0.82 and -0.80), end-diastolic volume (r = 0.61 and -0.58), and end-systolic volume (r = 0.46 and -0.48). Forward stepwise linear regression analysis revealed that, of all variables tested, LVEDP was the only independent determinant of MPI (r = 0.84) and LVFS/MPI (r = 0.83). We conclude that MPI and LVFS/MPI correlate strongly and better than the classic noninvasive TTE parameters with established, invasively assessed indexes of contractility, preload, and volumetry. These findings support the use of these two new noninvasive indexes for long-term analysis of the post-MI LV remodeling.
Resumo:
OBJECTIVE: The tradition of yearly reports on cardiac catheter interventions in Europe has been initiated in 1992. This 11th report presents aggregated data on cardiac catheter procedures in 30 European countries in the year 2002. DESIGN AND SETTING: A detailed questionnaire addressing summary data of all cardiac interventions was mailed to presidents or delegates of the national societies of cardiology in Europe. The questionnaire was distributed to all institutions with cardiac catheterisation programs. All questionnaires were compiled in a national summary data sheet, then entered into a central database and subsequently analysed. MAIN OUTCOME MEASURES: Coronary angiography, PTCA, and stenting in absolute numbers and per million inhabitants in the participating countries and the whole of Europe. RESULTS: Overall, 1,901,932 coronary angiograms were reported. The population-adjusted rate of coronary angiograms amounted to an absolute mean of 3358 per 10(6) inhabitants, an increase of 7% compared with 2001. A total of 686,869 PTCA procedures were reported. The mean European number of PTCAs per 10(6) inhabitants increased by 10% from 1103 in 2001 to 1213 in 2002. Procedures with stenting increased by 17% from 508,999 to 593,906. The stenting rate was 86% compared with 82% in 2001. CONCLUSIONS: In pace with epidemiological demand and the need to catch-up from underuse in certain countries, a continuous and considerable growth of coronary interventions can be observed. It will take years to find out whether the announced change of paradigm in the treatment of multivessel disease in the wake of drug-eluting stents will come true.
Resumo:
BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.
Resumo:
Central venous catheters are established as vascular access in hemodialysis therapy. Vascular catheter misdirection may occur and is a well known problem. We present a rare catheter malposition in a young dialysis patient with consequent dilatation of the azygos vein system, simulating the appearance of an azygos continuation syndrome.
Resumo:
BACKGROUND: Early catheter-related infection is a serious complication in cancer treatment, although risk factors for its occurrence are not well established. The authors conducted a prospective study to identify the risk factors for developing early catheter-related infection. METHODS: All consecutive patients with cancer who underwent insertion of a central venous catheter were enrolled and were followed prospectively during 1 month. The study endpoint was occurrence of early catheter-related infection. RESULTS: Over 10,392 catheter-days of follow-up, 14 of 371 patients had early catheter-related infections (14 patients in 10,392 catheter-days or 1.34 per 1000 catheter-days). The causative pathogens were gram positive in 11 of 14 patients. In univariate analysis, the risk factors for early catheter-related infection were aged <10 years (P = .0001), difficulties during insertion (P < 10(-6)), blood product administration (P < 10(-3)), parenteral nutrition (P < 10(-4)), and use >2 days (P < 10(-6)). In multivariate analysis, 3 variables remained significantly associated with the risk of early catheter-related infection: age <10 years (odds ratio [OR], 18.4; 95% confidence interval [95% CI], 1.9-106.7), difficulties during insertion procedure (OR, 25.6; 95% CI, 4.2-106), and parenteral nutrition (OR, 28.5; 95% CI, 4.2-200). CONCLUSIONS: On the day of insertion, 2 variables were identified that were associated with a high risk of developing an early catheter-related infection: young age and difficulties during insertion. The results from this study may be used to identify patients who are at high risk of infection who may be candidates for preventive strategies.
Resumo:
Acute ischemic stroke is a major cause of morbidity and mortality in industrialized nations. The sequel of stroke ranges from mild to severe disability and even death. Since the impairment may be permanent, the costs to society from work incapacity and the need for long-term care can be high. Additionally, the burden of suffering associated with the disease may have devastating effects on individuals and families.Following the occlusion of a cerebral vessel, the full extent of the infarction may not become clinically and radiologically apparent until days after. By then, the surrounding watershed zone, or penumbra, either survives or succumbs to necrosis over time. The natural history of this "tissue at risk" is determined by two factors: the collateralization from other vascular territories and the possible occurrence of spontaneous recanalization of the occluded vessel. The current treatment options for acute ischemic stroke are aiming at an early and sustained restoration of flow to the penumbra. The effect of the treatment is therefore time-dependent and the neurologic outcome is a function of the time span between onset of symptoms and recanalization therapy as well as of the recanalization rate associated with a specific treatment.This report summarizes the results of the major trials on catheter-based interventions, either using thrombolytic drugs or novel mechanical approaches being developed to treat patients with acute ischemic stroke.
Resumo:
The technique of transseptal puncture for catheter ablation of atrial fibrillation after percutaneous closure of a foramen ovale with the Amplatzer Occluder is demonstrated based on 2 representative cases.
Resumo:
OBJECTIVE: To clarify the role of the pulmonary artery catheter in the intensive care unit. DATA SOURCES: Recent and relevant literature from MEDLINE and authors' personal databases. STUDY SELECTION: Studies on pulmonary artery catheter use and use of other monitoring devices in critically ill patients. DATA EXTRACTION: Based largely on clinical experience and assessment of the relevant published literature and in response to recent articles attacking the pulmonary artery catheter, we propose that the pulmonary artery catheter is still a valuable tool for the hemodynamic monitoring of patients with complex disease processes in whom the information obtained from the pulmonary artery catheter may influence management. We suggest that there is a need to revisit the basics of hemodynamic management and reassess the way in which the pulmonary artery catheter is used, applying three key principles: correct measurement, correct data interpretation, and correct application. CONCLUSION: The pulmonary artery catheter is still a valuable tool for hemodynamic monitoring when used in selected patients and by physicians adequately trained to correctly interpret and apply the data provided.