983 resultados para Surgery, Operative.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. METHODS: Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: <60, 61 to 90, 91 to 120, and >120 minutes. Three categories were defined for operative time: <120, 121 to 150, and >150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. RESULTS: In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. CONCLUSION: We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Measurement of vital capacity (VC) by spirometry is the most widely used technique for lung function evaluation, however, this form of assessment is costly and further investigation of other reliable methods at lower cost is necessary. Objective: To analyze the correlation between direct vital capacity measured with ventilometer and with incentive inspirometer in patients in pre and post cardiac surgery. Methodology Cross-sectional comparative study with patients undergoing cardiac surgery. Respiratory parameters were evaluated through the measurement of VC performed by ventilometer and inspirometer. To analyze data normality the Kolmogorov-Smirnov test was applied, for correlation the Pearson correlation coefficient was used and for comparison of variables in pre and post operative period Student's t test was adopted. We established a level of ignificance of 5%. Data was presented as an average, standard deviation and relative frequency when needed. The significance level was set at 5%. Results We studied 52 patients undergoing cardiac surgery, 20 patients in preoperative with VC-ventilometer: 32.95 ± 11.4 ml/kg and VC-inspirometer: 28.9 ± 11 ml/Kg, r = 0.7 p < 0.001. In the post operatory, 32 patients were evaluated with VC-ventilometer: 28.27 ± 12.48 ml/kg and VC-inspirometer: 26.98 ± 11 ml/Kg, r = 0.95 p < 0.001. Presenting a very high correlation between the evaluation forms studied. Conclusion There was a high correlation between DVC measures with ventilometer and incentive spirometer in pre and post CABG surgery. Despite this, arises the necessity of further studies to evaluate the repercussion of this method in lowering costs at hospitals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Introduction Several studies have shown that maximizing stroke volume (or increasing it until a plateau is reached) by volume loading during high-risk surgery may improve post-operative outcome. This goal could be achieved simply by minimizing the variation in arterial pulse pressure (ΔPP) induced by mechanical ventilation. We tested this hypothesis in a prospective, randomized, single-centre study. The primary endpoint was the length of postoperative stay in hospital. Methods Thirty-three patients undergoing high-risk surgery were randomized either to a control group (group C, n = 16) or to an intervention group (group I, n = 17). In group I, ΔPP was continuously monitored during surgery by a multiparameter bedside monitor and minimized to 10% or less by volume loading. Results Both groups were comparable in terms of demographic data, American Society of Anesthesiology score, type, and duration of surgery. During surgery, group I received more fluid than group C (4,618 ± 1,557 versus 1,694 ± 705 ml (mean ± SD), P < 0.0001), and ΔPP decreased from 22 ± 75 to 9 ± 1% (P < 0.05) in group I. The median duration of postoperative stay in hospital (7 versus 17 days, P < 0.01) was lower in group I than in group C. The number of postoperative complications per patient (1.4 ± 2.1 versus 3.9 ± 2.8, P < 0.05), as well as the median duration of mechanical ventilation (1 versus 5 days, P < 0.05) and stay in the intensive care unit (3 versus 9 days, P < 0.01) was also lower in group I. Conclusion Monitoring and minimizing ΔPP by volume loading during high-risk surgery improves postoperative outcome and decreases the length of stay in hospital. Trial registration NCT00479011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thoracic endovascular aortic repair is increasingly becoming the standard treatment of many thoracic aortic pathologies. New reliable and accurate stent grafts are emerging to widen the endovascular treatment options. We report the results of RELAY (Bolton Medical, Barcelona, Spain) in the large RELAY Endovascular Registry for Thoracic Disease (RESTORE) European registry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Temporal hollowing due to temporal muscle atrophy after standard skull base surgery is common. Various techniques have been previously described to correct the disfiguring defect. Most often reconstruction is performed using freehand molded polymethylmethacrylate cement. This method and material are insufficient in terms of aesthetic results and implant characteristics. We herein propose reconstruction of such defects with a polyetheretherketone (PEEK)-based patient-specific implant (PSI) including soft-tissue augmentation to preserve normal facial topography. We describe a patient who presented with a large temporo-orbital hemangioma that had been repaired with polymethylmethacrylate 25 years earlier. Because of a toxic skin atrophy fistula, followed by infection and meningitis, this initial implant had to be removed. The large, disfiguring temporo-orbital defect was reconstructed with a PEEK-based PSI. The lateral orbital wall and the temporal muscle atrophy were augmented with computer-aided design and surface modeling techniques. The operative procedure to implant and adopt the reconstructed PEEK-based PSI was simple, and an excellent cosmetic outcome was achieved. The postoperative clinical course was uneventful over a 5-year follow-up period. Polyetheretherketone-based combined bony and soft contour remodeling is a feasible and effective method for cranioplasty including combined bone and soft-tissue reconstruction of temporo-orbital defects. Manual reconstruction of this cosmetically delicate area carries an exceptional risk of disfiguring results. Augmentation surgery in this anatomic location needs accurate PSIs to achieve satisfactory cosmetic results. The cosmetic outcome achieved in this case is superior compared with previously reported techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the past decades, major progress in patient selection, surgical techniques and anaesthetic management have largely contributed to improved outcome in lung cancer surgery. The purpose of this study was to identify predictors of post-operative cardiopulmonary morbidity in patients with a forced expiratory volume in 1 s <80% predicted, who underwent cardiopulmonary exercise testing (CPET). In this observational study, 210 consecutive patients with lung cancer underwent CPET with completed data over a 9-yr period (2001-2009). Cardiopulmonary complications occurred in 46 (22%) patients, including four (1.9%) deaths. On logistic regression analysis, peak oxygen uptake (peak V'(O₂) and anaesthesia duration were independent risk factors of both cardiovascular and pulmonary complications; age and the extent of lung resection were additional predictors of cardiovascular complications, whereas tidal volume during one-lung ventilation was a predictor of pulmonary complications. Compared with patients with peak V'(O₂) >17 mL·kg⁻¹·min⁻¹, those with a peak V'(O₂) <10 mL·kg⁻¹·min⁻¹ had a four-fold higher incidence of cardiac and pulmonary morbidity. Our data support the use of pre-operative CPET and the application of an intra-operative protective ventilation strategy. Further studies should evaluate whether pre-operative physical training can improve post-operative outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the peri-operative analgesic efficacy of intra-articular bupivacaine administered before or after stifle arthrotomy. STUDY DESIGN: Prospective, randomized, blind, placebo-controlled experimental trial. ANIMALS: Thirty-nine healthy goats. METHODS: The goats were allocated randomly to one of three intra-articular treatment groups: group PRE (bupivacaine before and saline after surgery), group POST (saline before and bupivacaine after surgery) and group CON (saline before and after surgery). Anaesthesia was maintained with a constant end-tidal sevoflurane of 2.5%. Intra-operatively heart rate (HR), respiratory rate and mean arterial blood pressure (MAP) after critical surgical events (CSE) were recorded and compared with pre-incision values. Propofol requirements to maintain surgical anaesthesia were recorded. Flunixin was administered for 5 days. Post-operative pain assessment at 20 minutes, 2 hours, 4 hours after recovery and on day 2 and 3 included a multidimensional pain score (MPS), a lameness score and mechanical nociceptive threshold (MNT) testing. Rescue analgesia consisted of systemic opioids. Data were analysed using Kruskal-Wallis, Mann-Whitney, Friedman or chi-square tests as appropriate. RESULTS: Intra-operatively, group PRE had lower HR and MAP at several CSEs than groups POST/CON and required less propofol [0 mg kg(-1) (0-0 mg kg(-1))] than group POST/CON [0.3 mg kg(-1) (0-0.6 mg kg(-1))]. Post-operatively, group POST had significantly higher peri-articular MNTs than groups PRE and CON up to 4 hours after recovery. No treatment effect was detected for MPS, lameness scores and rescue analgesic consumption at any time point. CONCLUSIONS AND CLINICAL RELEVANCE: Pre-operative intra-articular bupivacaine provided notable intra-operative analgesia in goats undergoing stifle arthrotomy but did not reduce post-operative pain. Post-operative intra-articular bupivacaine provided a short lasting reduction of peri-articular hyperalgesia without affecting the requirements for systemic analgesia. Multimodal perioperative pain therapy is recommended to provide adequate analgesia for stifle arthrotomy in goats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to investigate whether total arch replacement (TAR) during initial surgery for root aneurysm should be routinely performed in patients with Marfan syndrome (MFS). METHODS: Retrospective analysis of 94 consecutive MFS patients fulfilling Ghent criteria who underwent 148 aortic surgeries and were followed at this institution during the past 16 years. RESULTS: The mean follow-up interval was 8.8 ± 7 years. Initial presentation was acute aortic dissection (AAD) in 35% of patients (76% Type A and 24% Type B) and aneurismal disease in 65%. TAR was performed in 8% of patients during initial surgery for AAD (otherwise a hemi-arch replacement was performed) and 1.6% in elective root repair. Secondary TAR had to be performed in only 3% of patients without, but in 33% following AAD (33% Type A and 33% Type B; P = 0.0001). Thirty-day, 6-month, 1-year and overall mortalities were 3.2, 5.3, 6.4 and 11.7%, respectively. Operative and 30-day mortalities in secondary aortic arch replacement were zero. Secondary TAR after AAD did not increase the need for the replacement of the entire thoracoabdominal aorta during follow-up compared with patients without secondary TAR (37 vs 40%, P = 1.0). CONCLUSIONS: MFS patients undergoing elective root repair have small risk of reinterventions on the aortic arch, and primary prophylactic replacement does not seem to be justified. In patients with AAD, the need for reinterventions is precipitated by the dissection itself and not by limiting the procedure to the hemi-arch replacement in the emergency setting. Limiting surgery to the aortic root, ascending aorta and proximal aortic arch is associated with low mortality in MFS patients presenting with AAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

2D-3D registration of pre-operative 3D volumetric data with a series of calibrated and undistorted intra-operative 2D projection images has shown great potential in CT-based surgical navigation because it obviates the invasive procedure of the conventional registration methods. In this study, a recently introduced spline-based multi-resolution 2D-3D image registration algorithm has been adapted together with a novel least-squares normalized pattern intensity (LSNPI) similarity measure for image guided minimally invasive spine surgery. A phantom and a cadaver together with their respective ground truths were specially designed to experimentally assess possible factors that may affect the robustness, accuracy, or efficiency of the registration. Our experiments have shown that it is feasible for the assessed 2D-3D registration algorithm to achieve sub-millimeter accuracy in a realistic setup in less than one minute.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of all efforts to reduce the need of allogeneic blood transfusions is to avoid associated risks. There should particularly be a favourable effect according to the rate of transfusion-transmitted virus infections and immunological side-effects. The acceptance of an individually adjusted lowest haematocrit level and the minimisation of intra-operative blood loss by the application of optimal surgical techniques are among the most essential strategies to reduce or even avoid allogeneic blood transfusions. In addition the following interventions are generally accepted: Preoperative autologous blood donation, where appropriate supported by erythropoietin Preoperative haemodilution, where appropriate supported by erythropoietin Intra- and postoperative blood salvage Topical or systemic pharmacologic interventions to accelerate haemostasis Controlled hypotension Efficacy and indication of the different measures always depend on the individual circumstances of the specific patient. Therefore one should develop an individual approach for every case. In this context the most important subjects are an optimal coordination and if required an appropriate combination of the discussed methods. Algorithms which preoperatively allow approximate calculation of expected transfusion need may be a meaningful tool to facilitate blood conservation planning. However, at the same time one must consider that all strategies to reduce allogeneic transfusion needs are also associated with particular risks. Therefore one has to weigh carefully the pros and cons prior to their application, including the possible alternative of allogeneic transfusion in one's decision making process.