900 resultados para Subjective quality


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of the study were to translate and adapt the Subjective Handicap of Epilepsy (SHE) instrument to Brazilian Portuguese and to determine its psychometric properties for the evaluation of quality of life in patients with epilepsy. A sample of 448 adult patients with epilepsy with different clinical profiles (investigation, preoperative period, postoperative period, and drug treatment follow-up) was evaluated with the SHE and the Epilepsy Surgery Inventory (ESI-55). Exploratory factorial analysis demonstrated that four factors explained 60.47% of the variance and were sensitive to discriminate the different clinical groups, with the preoperative group having the poorest quality of life. Internal consistency ranged from 0.92 to 0.96, and concurrent validity with the ESI-55 was moderate/strong (0.32-0.70). Test-retest reliability was confirmed, with an ICC value of 0.54 (2 days), 0.91 (7 days), and 0.97 (30 days). The SHE had satisfactory psychometric qualities for use in the Brazilian population, similar to those of the original version. The instrument seems to be more adequate in psychometric terms for the postoperative and drug treatment follow-up groups, and its use should be encouraged. (c) 2012 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to investigate the relationships between the constructs subjective well-being (SWB), dyadic adjustment (DA) and marital satisfaction (MS). Participants were 106 married Brazilians, of both sexes, with a mean age of 42 (+/- 11) years. Instruments used for the sociodemographic characterization and socioeconomic classification were the Subjective Wellbeing Scale (SWBS), the Dyadic Adjustment Scale (DAS) and the Marital Satisfaction Scale (MSS). Through the analysis of correlations and of stepwise multiple regression, it was verified that all the factors of the dyadic adjustment showed correlation with the marital satisfaction. The satisfaction with life (factor of the SWBS) and dyadic satisfaction (factor of the DAS), were positively and significantly correlated (r = .20; p = .04), which reveals that people who say they are satisfied with life in different domains also do so in relation to the marital experience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:In the BIG 1-98 trial objective cognitive function improved in postmenopausal women 1 year after cessation of adjuvant endocrine therapy for breast cancer. This report evaluates changes in subjective cognitive function (SCF).Methods:One hundred postmenopausal women, randomised to receive 5 years of adjuvant tamoxifen, letrozole, or a sequence of the two, completed self-reported measures on SCF, psychological distress, fatigue, and quality of life during the fifth year of trial treatment (year 5) and 1 year after treatment completion (year 6). Changes between years 5 and 6 were evaluated using the Wilcoxon signed-rank test. Subjective cognitive function and its correlates were explored.Results:Subjective cognitive function and the other patient-reported outcomes did not change significantly after cessation of endocrine therapy with the exception of improvement for hot flushes (P=0.0005). No difference in changes was found between women taking tamoxifen or letrozole. Subjective cognitive function was the only psychosocial outcome with a substantial correlation between year 5 and 6 (Spearman's R=0.80). Correlations between SCF and the other patient-reported outcomes were generally low.Conclusion:Improved objective cognitive function but not SCF occur following cessation of adjuvant endocrine therapy in the BIG 1-98 trial. The substantial correlation of SCF scores over time may represent a stable attribute.British Journal of Cancer advance online publication, 24 April 2012; doi:10.1038/bjc.2012.156 www.bjcancer.com.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study is to evaluate (a) health-related quality of life (HRQL) after vertical banded gastroplasty (VBG) (Mason) and (b) predictors of HRQL. SUBJECTS: Eighty-two consecutive patients were assessed preoperatively and then after 6, 12 and 24 months. Patients filled out questionnaires for subjective appraisal of HRQL (physical well-being, mood, physical performance, perceived health, social support and coping/adjustment). RESULTS: The greatest improvement in weight and HRQL was seen within 6 months of surgery. Twenty-four months after VBG weight reduction (P<0.05), perceived health (P<0.05), physical well-being (P<0.05), physical performance (P<0.05), mood (P<0.05), coping/adjustment (P<0.05) continued to be better than before surgery. Preoperative binge eating was the most important predictor of HRQL. CONCLUSION: Two years after VBG weight loss and a significant improvement of HRQL can be found. HRQL and weight loss are not associated in terms of outcome, indicating that weight loss alone may not be enough to improve HRQL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In patients with malignant pleural mesothelioma undergoing a multimodality therapy, treatment toxicity may outweigh the benefit of progression-free survival. The subjective experience across different treatment phases is an important clinical outcome. This study compares a standard with an individual quality of life (QoL) measure used in a multi-center phase II trial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Elevated platelet count might reflect increased inflammation as an etiological factor for venous thromboembolism (VTE). Poor sleep, fatigue, and exhaustion are all associated with inflammation and are also common sequelae of chronic psychological stress that previously predicted increased risk of VTE. We hypothesized that platelet count would be high in patients with VTE who sleep poorly and who are fatigued and exhausted. We investigated 205 patients scheduled for thrombophilia work-up > or =3 months after an objectively diagnosed venous thromboembolic event. They completed the Jenkins Sleep Questionnaire to rate subjective sleep quality and the short forms of the Multidimensional Fatigue Symptom Inventory and Maastricht Vital Exhaustion Questionnaire. Platelet count was determined by a mechanical Coulter counter. Analyses controlled for age, sex, body mass index, time since the index event, and medication. After taking into account these covariates, poorer sleep quality (p = 0.001; DeltaR(2)= 0.046), high fatigue (p = 0.008; DeltaR(2)= 0.032), and vital exhaustion (p = 0.050; DeltaR(2)= 0.017) were all associated with elevated platelet count. In addition, high level of fatigue mediated the relationship between poor sleep quality and elevated platelet count (p = 0.046). Poor sleep quality, high levels of fatigue, and vital exhaustion were identified as correlates of an elevated platelet count in patients with a previous episode of VTE. Given the emerging role of inflammatory processes in VTE, the findings suggest a mechanism through which behavioral and chronic psychological stressors might contribute to incident and recurrent venous thrombotic events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, the oral health-related quality of life of 18 patients (13 men and 5 women) was evaluated using validated questionnaires as proposed by the European Organization of Research and Treatment of Cancer (EORTC). The patients belonged to a cohort of 48 patients, whose prosthetic treatment was performed during the years 2004-2007. In the course of tumor resection, 12 patients underwent graft surgery and 14 patients radiotherapy. One patient required a nasal epithesis since resection of the nose became necessary. Five patients underwent a full block resection of the mandible, and tumor resection in 3 patients resulted in a large oronasal communication. Prosthetic rehabilitation was performed in all patients, and the follow-up period with regular care covered a minimum of 3 years. Eleven patients received dental implants for better support and retention of the prostheses. In spite of compromised oral conditions, functional restrictions, and some difficulties with the prostheses, the answers to the questionnaire were quite positive. The majority judged their general health as good or even excellent. The subjective perception of the patients may contradict the objective view by the dentist. In fact, the individual patient's history and experience provide a better understanding of the impact of oral tumors on daily life. The overall assessment identified 4 items that were perceived as major problems by all patients: swallowing solid food, dry mouth, limited mouth opening, and appearance. Prosthetic rehabilitation has only a limited influence on such problems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND CONTEXT A new device, DensiProbe, has been developed to provide surgeons with intraoperative information about bone strength by measuring the peak breakaway torque. In cases of low bone quality, the treatment can be adapted to the patient's condition, for example, by improving screw-anchorage with augmentation techniques. PURPOSE The objective of this study was to investigate the feasibility of DensiProbe Spine in patients undergoing transpedicular fixation. STUDY DESIGN Prospective feasibility study on consecutive patients. PATIENT SAMPLE Fourteen women and 16 men were included in this study. OUTCOME MEASURES Local and general bone quality. METHODS These consecutive patients scheduled for transpedicular fixation were evaluated for bone mineral density (BMD), which was measured globally by dual-energy X-ray absorptiometry and locally via biopsies using quantitative microcomputed tomography. The breakaway torque force within the vertebral body was assessed intraoperatively via the transpedicular approach with the DensiProbe Spine. The results were correlated with the areal BMD at the lumbar spine and the local volumetric BMD (vBMD) and a subjective impression of bone strength. The feasibility of the method was evaluated, and the clinical and radiological performance was evaluated over a 1-year follow-up. This study was funded by an AO Spine research grant; DensiProbe was developed at the AO Research Institute Davos, Switzerland; the AO Foundation is owner of the intellectual property rights. RESULTS In 30 patients, 69 vertebral levels were examined. The breakaway torque consistently correlated with an experienced surgeon's quantified impression of resistance as well as with vBMD of the same vertebra. Beyond a marginal prolongation of surgery time, no adverse events related to the usage of the device were observed. CONCLUSIONS The intraoperative transpedicular measurement of the peak breakaway torque was technically feasible, safe, and reliably predictive of local vBMD during dorsal spinal instrumentations in a clinical setting. Larger studies are needed to define specific thresholds that indicate a need for the augmentation or instrumentation of additional levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless Mesh Networks (WMNs) are increasingly deployed to enable thousands of users to share, create, and access live video streaming with different characteristics and content, such as video surveillance and football matches. In this context, there is a need for new mechanisms for assessing the quality level of videos because operators are seeking to control their delivery process and optimize their network resources, while increasing the user’s satisfaction. However, the development of in-service and non-intrusive Quality of Experience assessment schemes for real-time Internet videos with different complexity and motion levels, Group of Picture lengths, and characteristics, remains a significant challenge. To address this issue, this article proposes a non-intrusive parametric real-time video quality estimator, called MultiQoE that correlates wireless networks’ impairments, videos’ characteristics, and users’ perception into a predicted Mean Opinion Score. An instance of MultiQoE was implemented in WMNs and performance evaluation results demonstrate the efficiency and accuracy of MultiQoE in predicting the user’s perception of live video streaming services when compared to subjective, objective, and well-known parametric solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Endothelial function typically precedes clinical manifestations of cardiovascular disease and provides a potential mechanism for the associations observed between cardiovascular disease and sleep quality. This study examined how subjective and objective indicators of sleep quality relate to endothelial function, as measured by brachial artery flow-mediated dilation (FMD). In a clinical research centre, 100 non-shift working adults (mean age: 36 years) completed FMD testing and the Pittsburgh Sleep Quality Index, along with a polysomnography assessment to obtain the following measures: slow wave sleep, percentage rapid eye movement (REM) sleep, REM sleep latency, total arousal index, total sleep time, wake after sleep onset, sleep efficiency and apnea-hypopnea index. Bivariate correlations and follow-up multiple regressions examined how FMD related to subjective (i.e., Pittsburgh Sleep Quality Index scores) and objective (i.e., polysomnography-derived) indicators of sleep quality. After FMD showed bivariate correlations with Pittsburgh Sleep Quality Index scores, percentage REM sleep and REM latency, further examination with separate regression models indicated that these associations remained significant after adjustments for sex, age, race, hypertension, body mass index, apnea-hypopnea index, smoking and income (Ps < 0.05). Specifically, as FMD decreased, scores on the Pittsburgh Sleep Quality Index increased (indicating decreased subjective sleep quality) and percentage REM sleep decreased, while REM sleep latency increased (Ps < 0.05). Poorer subjective sleep quality and adverse changes in REM sleep were associated with diminished vasodilation, which could link sleep disturbances to cardiovascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To compare the computed tomography (CT) dose and image quality with the filtered back projection against the iterative reconstruction and CT with a minimal electronic noise detector. METHODS A lung phantom (Chest Phantom N1 by Kyoto Kagaku) was scanned with 3 different CT scanners: the Somatom Sensation, the Definition Flash and the Definition Edge (all from Siemens, Erlangen, Germany). The scan parameters were identical to the Siemens presetting for THORAX ROUTINE (scan length 35 cm and FOV 33 cm). Nine different exposition levels were examined (reference mAs/peek voltage): 100/120, 100/100, 100/80, 50/120, 50/100, 50/80, 25/120, 25/100 and 25 mAs/80 kVp. Images from the SOMATOM Sensation were reconstructed using classic filtered back projection. Iterative reconstruction (SAFIRE, level 3) was performed for the two other scanners. A Stellar detector was used with the Somatom Definition Edge. The CT doses were represented by the dose length products (DLPs) (mGycm) provided by the scanners. Signal, contrast, noise and subjective image quality were recorded by two different radiologists with 10 and 3 years of experience in chest CT radiology. To determine the average dose reduction between two scanners, the integral of the dose difference was calculated from the lowest to the highest noise level. RESULTS When using iterative reconstruction (IR) instead of filtered back projection (FBP), the average dose reduction was 30%, 52% and 80% for bone, soft tissue and air, respectively, for the same image quality (P < 0.0001). The recently introduced Stellar detector (Sd) lowered the radiation dose by an additional 27%, 54% and 70% for bone, soft tissue and air, respectively (P < 0.0001). The benefit of dose reduction was larger at lower dose levels. With the same radiation dose, an average of 34% (22%-37%) and 25% (13%-46%) more contrast to noise was achieved by changing from FBP to IR and from IR to Sd, respectively. For the same contrast to noise level, an average of 59% (46%-71%) and 51% (38%-68%) dose reduction was produced for IR and Sd, respectively. For the same subjective image quality, the dose could be reduced by 25% (2%-42%) and 44% (33%-54%) using IR and Sd, respectively. CONCLUSION This study showed an average dose reduction between 27% and 70% for the new Stellar detector, which is equivalent to using IR instead of FBP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability. MATERIALS AND METHODS 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20-40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4™, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined. RESULTS In LDCT high iDose4™ levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4™ levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4™ levels (> iDose4). LDCT with iDose4™ level 6 was determined to be of equivalent image quality as RDCT with FBP. CONCLUSION iDose4™ substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4™ levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To compare image quality and diagnostic confidence of 100 kVp CT pulmonary angiography (CTPA) in patients with body weights (BWs) below and above 100kg. MATERIALS AND METHODS The present retrospective study comprised 216 patients (BWs of 75-99kg, 114 patients; 100-125kg, 88 patients; >125kg, 14 patients), who received 100 kVp CTPA to exclude pulmonary embolism. The attenuation was measured and the contrast-to-noise ratio (CNR) was calculated in the pulmonary trunk. Size-specific dose estimates (SSDEs) were evaluated. Three blinded radiologists rated subjective image quality and diagnostic confidence. Results between the BW groups and between three body mass index (BMI) groups (BMI <25kg/m(2), BMI = 25-29.9kg/m(2), and BMI ≥30kg/m(2), i.e., normal weight, overweight, and obese patients) were compared using the Kruskal-Wallis test. RESULTS Vessel attenuation was higher and SDDE was lower in the 75-99kg group than at higher BWs (p-values between <0.001 and 0.03), with no difference between the 100-125 and >125kg groups (p = 0.892 and 1). Subjective image quality and diagnostic confidence were not different among the BW groups (p = 0.225 and 1). CNR was lower (p < 0.006) in obese patients than in normal weight or overweight subjects. Diagnostic confidence was not different in the BMI groups (p = 0.105). CONCLUSION CTPA at 100 kVp tube voltage can be used in patients weighing up to 125kg with no significant deterioration of subjective image quality and confidence. The applicability of 100 kVp in the 125-150kg BW range needs further testing in larger collectives.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.