875 resultados para Solvent replacement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the influence of ankle osteoarthritis (AOA) treatments, i.e., ankle arthrodesis (AA) and total ankle replacement (TAR), on the kinematics of multi-segment foot and ankle complex during relatively long-distance gait. Forty-five subjects in four groups (AOA, AA, TAR, and control) were equipped with a wearable system consisting of inertial sensors installed on the tibia, calcaneus, and medial metatarsals. The subjects walked 50-m twice while the system measured the kinematic parameters of their multi-segment foot: the range of motion of joints between tibia, calcaneus, and medial metatarsals in three anatomical planes, and the peaks of angular velocity of these segments in the sagittal plane. These parameters were then compared among the four groups. It was observed that the range of motion and peak of angular velocities generally improved after TAR and were similar to the control subjects. However, unlike AOA and TAR, AA imposed impairments in the range of motion in the coronal plane for both the tibia-calcaneus and tibia-metatarsals joints. In general, the kinematic parameters showed significant correlation with established clinical scales (FFI and AOFAS), which shows their convergent validity. Based on the kinematic parameters of multi-segment foot during 50-m gait, this study showed significant improvements in foot mobility after TAR, but several significant impairments remained after AA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eimeria motelo sp. n. is described from faeces of the yellow-footed tortoise, Geochelone denticulata (L.). Oocysts are irregularly ellipsoidal or cylindrical, with slightly expressed lobed protrusions and irregularities at the poles, possibly caused by wrinkling of the oocyst wall, 17 (15-19) × 9.4 (8.5-11) µm, shape index (length/width) being 1.81 (1.45-2). The oocyst wall is smooth, single-layered, 0.5 µm thick with no micropyle. There are no polar bodies. Sporocysts are ellipsoidal, 8.9 (7.5-10) × 4.4 (4-5) µm, shape index 2.03 (1.7-2.5). A sporocyst residuum is present, composed of many granules of irregular size. The sporozoites are elongate, lying lengthwise in the sporocysts. Comparison with other species of the genus Eimeria parasitising members of family Testudinidae indicates that the presently described coccidium represents a new species. The name of Eimeria carinii Lainson, Costa & Shaw, 1990 is found to be preoccupied by a homonym, Eimeria carinii Pinto 1928 given to a coccidium from Rattus norvegicus. Therefore, it is replaced by Eimeria lainsoni nom. nov.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined Tetanus/Low Dose Diphtheria Vaccine for Adults and Adolescents

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La teràpia suplementària de ferro millora la capacitat d’exercici i la qualitat de vida en malalts amb una cardiopatia congènita cianòtica i/ o síndrome d’Eisenmenger El dèficit de ferro és una troballa comú en la cardiopatia congènita cianòtica, i pot ser la causa d’una reducció en la capacitat d’exercici. Actualment, està indicada la reposició dels dipòsits de ferro en aquest grup de malalts, éssent les evidències científiques escasses. En el present treball investiguem la seguretat i eficàcia del tractament amb ferro en malalts amb una cardiopatia congènita cianòtica. Per tal motiu, vint-i-cinc malalts amb una cardiopatia congenita cianòtica i dèficit de ferro van ser inclosos de forma prospectiva entre Agost del 2008 i Gener del 2009. El tractament utilitzat fou fumarat ferròs oral, fins a una dosi màxima de 200 mg tres vegades al dia. En l’anàlisi basal i als tres mesos de seguiment es va utilitzar el test de qualitat de vida “CAMPHOR”, el test de la marxa dels 6 minuts i la prova d’esforç amb consum d’oxigen. L’edat mitja fou 39.9+/-10.9 anys, 80% dones. Catorze malalts tenien la síndrome d’Eisenmenger, sis una malaltia cianòtica complexa i cinc circulació de Fontan. Cap d’ells va haver d'interrompre el tractament degut a efectes adversos. Després de tres mesos de tractament, l’hemoglobina (19.0+/-2.9g/dL a 20.4+/-2.7g/dL, p&0.001), ferritina (13.3+/-4.7mug/L a 54.1+/-24.2mug/L, p&0.001) i saturació de transferrina (17.8+/-9.6% a 34.8+/-23.4%, p&0.001) van augmentar significativament. També hi va haver una millora significativa en la puntuació del test de qualitat de vida (20.7+/-10.9 a 16.2+/-10.4, p=0.001) i el test de la marxa (371.7+/-84.7m a 402.8.0+/-74.9m, p=0.001). No es van evidenciar canvis significatius en els valors de consum d’oxigen (40.7+/-9.2% a 43.8+/-12.4%, p=0.15). En definitiva, la teràpia suplementària amb ferro en els malats amb una cardiopatia congènita cianòtica i dèficit de ferro és segura i millora la qualitat de vida i la capacitat funcional. En aquest grup de malalts, per tant, és aconsellable identificar el dèficit de ferro i restaurar-ne els seus dipòsits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

METHODS: Twenty-two patients receiving (R)-methadone maintenance treatment were switched to a double dose of (R,S)-methadone: blood samples were collected before and after the change, and the concentrations of the enantiomers were measured. In the second period, during racemic methadone treatment, important interindividual variability in the stereoselective disposition of the enantiomers of methadone was measured, with (R)/(S) ratios ranging from 0.63 to 2.40. This point should be taken into account particularly with respect to therapeutic drug monitoring of racemic methadone. RESULTS: A significant decrease P < 0.005 in the mean serum concentration/dose ratios of the active (R)-enantiomer before and after the change was measured (mean 3.97 and 3.33). CONCLUSION: Although of small amplitude (16%), this decrease confirms previously described adaptive changes in methadone pharmacokinetics during racemic methadone maintenance treatment and may necessitate, in some patients, a dose adjustment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sensitivity of two Gram positive (Staphylococcus aureus and Bacillus subtilis) and two Gram negative (Escherichia coli and Pseudomonas aeruginosa) pathogenic multi-drug resistant bacteria was tested against the crude extracts (cold aqueous, hot aqueous, and methanol extracts) of leaves and seeds of Argemone mexicana L. (Papaveraceae) by agar well diffusion method. Though all the extracts were found effective, yet the methanol extract showed maximum inhibition against the test microorganisms followed by hot aqueous extract and cold aqueous extract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many life-history traits are expressed interactively in life, but to a varying extent on different occasions. Changes in trait expression can be accounted for by differences in the quality of the environment ('environmental constraint' hypothesis) or by strategic adjustments, if the relative contribution of the trait to fitness varies with time ('strategic allocation' hypothesis). In birds, egg production is lower in replacement clutches than in first clutches, but it is unknown whether this reduction results from an environmental constraint (e.g. food being less available at the time when the replacement clutch is produced) or from a strategic allocation of resources between the two breeding attempts. To distinguish between these two hypotheses, we performed an experiment with black-legged kittiwakes (Rissa tridactyla). Pairs were either food-supplemented or not before the first clutch was laid onwards and we induced them to produce a replacement clutch by removing eggs once when the first clutch was complete. As predicted by the 'strategic allocation' hypothesis, egg production of food-supplemented and non-food-supplemented birds decreased between first and replacement clutches. This suggests that kittiwakes strategically reduce investment in egg production for their replacement clutches compared to first clutches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Associations of hormone-receptor positive breast cancer with excess adiposity are reasonably well characterized; however, uncertainty remains regarding the association of body mass index (BMI) with hormone-receptor negative malignancies, and possible interactions by hormone replacement therapy (HRT) use. METHODS Within the European EPIC cohort, Cox proportional hazards models were used to describe the relationship of BMI, waist and hip circumferences with risk of estrogen-receptor (ER) negative and progesterone-receptor (PR) negative (n = 1,021) and ER+PR+ (n = 3,586) breast tumors within five-year age bands. Among postmenopausal women, the joint effects of BMI and HRT use were analyzed. RESULTS For risk of ER-PR- tumors, there was no association of BMI across the age bands. However, when analyses were restricted to postmenopausal HRT never users, a positive risk association with BMI (third versus first tertile HR = 1.47 (1.01 to 2.15)) was observed. BMI was inversely associated with ER+PR+ tumors among women aged ≤49 years (per 5 kg/m2 increase, HR = 0.79 (95%CI 0.68 to 0.91)), and positively associated with risk among women ≥65 years (HR = 1.25 (1.16 to 1.34)). Adjusting for BMI, waist and hip circumferences showed no further associations with risks of breast cancer subtypes. Current use of HRT was significantly associated with an increased risk of receptor-negative (HRT current use compared to HRT never use HR: 1.30 (1.05 to 1.62)) and positive tumors (HR: 1.74 (1.56 to 1.95)), although this risk increase was weaker for ER-PR- disease (Phet = 0.035). The association of HRT was significantly stronger in the leaner women (BMI ≤22.5 kg/m2) than for more overweight women (BMI ≥25.9 kg/m2) for, both, ER-PR- (HR: 1.74 (1.15 to 2.63)) and ER+PR+ (HR: 2.33 (1.84 to 2.92)) breast cancer and was not restricted to any particular HRT regime. CONCLUSIONS An elevated BMI may be positively associated with risk of ER-PR- tumors among postmenopausal women who never used HRT. Furthermore, postmenopausal HRT users were at an increased risk of ER-PR- as well as ER+PR+ tumors, especially among leaner women. For hormone-receptor positive tumors, but not for hormone-receptor negative tumors, our study confirms an inverse association of risk with BMI among young women of premenopausal age. Our data provide evidence for a possible role of sex hormones in the etiology of hormone-receptor negative tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The objective of the present study was to compare current results of prosthetic valve replacement following acute infective native valve endocarditis (NVE) with that of prosthetic valve endocarditis (PVE). Prosthetic valve replacement is often necessary for acute infective endocarditis. Although valve repair and homografts have been associated with excellent outcome, homograft availability and the importance of valvular destruction often dictate prosthetic valve replacement in patients with acute bacterial endocarditis. METHODS: A retrospective analysis of the experience with prosthetic valve replacement following acute NVE and PVE between 1988 and 1998 was performed at the Montreal Heart Institute. RESULTS: Seventy-seven patients (57 men and 20 women, mean age 48 +/- 16 years) with acute infective endocarditis underwent valve replacement. Fifty patients had NVE and 27 had PVE. Four patients (8%) with NVE died within 30 days of operation and there were no hospital deaths in patients with PVE. Survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 70% +/- 9%, 59% +/- 10%, and 55% +/- 10% for PVE, respectively (p = 0.15). Reoperation-free survival at 1, 5, and 7 years averaged 80% +/- 6%, 76% +/- 6%, and 76% +/- 6% for NVE and 45% +/- 10%, 40% +/- 10%, and 36% +/- 9% for PVE (p = 0.003). Five-year survival for NVE averaged 75% +/- 9% following aortic valve replacement and 79% +/- 9% following mitral valve replacement. Five-year survival for PVE averaged 66% +/- 12% following aortic valve replacement and 43% +/- 19% following mitral valve replacement (p = 0.75). Nine patients underwent reoperation during follow-up: indications were prosthesis infection in 4 patients (3 mitral, 1 aortic), dehiscence of mitral prosthesis in 3, and dehiscence of aortic prosthesis in 2. CONCLUSIONS: Prosthetic valve replacement for NVE resulted in good long-term patient survival with a minimal risk of reoperation compared with patients who underwent valve replacement for PVE. In patients with PVE, those who needed reoperation had recurrent endocarditis or noninfectious periprosthetic dehiscence.