627 resultados para Silicone hydrogel contact lenses
Resumo:
Purpose: The primary outcome of this study is to compare the axial length growth of white European myopic children wearing orthokeratology contact lenses (OK) to a control group (CT) over a 7-year period. Methods: Subjects 6–12 years of age with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were prospectively allocated OK or distance single-vision spectacles (SV) correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals over a 2-year period. Subjects were invited to return to the clinic approximately 5 years later (i.e., 7 years after the beginning of the study) for assessment of their ocular refractive and biometric components. The CT consisted of 4 SV and 12 subjects who switched from SV to soft contact lens wear after the initial 2 years of SV lens wear. Changes in axial length relative to baseline over a 7-year period were compared between groups. Results: Fourteen and 16 subjects from the OK and CT groups, respectively, were examined 6.7 ± 0.5 years after the beginning of the study. Statistically significant changes in the axial length were found over time and between groups (both p <0.001), but not for the time*group interaction (p = 0.125). The change in the axial length for the OK group was 22% (p = 0.328), 42% (p = 0.007), 40% (p = 0.020), 41% (p = 0.013), and 33% (p = 0.062) lower than the CT group following 6, 12, 18, 24, and 84 months of lens wear, respectively. Conclusion: A trend toward a reduction in the rate of axial elongation of the order of 33% was found in the OK group in comparison to the CT group following 7 years of lens wear.
Resumo:
OBJETIVO: Desenvolver simulação computadorizada de ablação para produzir lentes de contato personalizadas a fim de corrigir aberrações de alta ordem. MÉTODOS: Usando dados reais de um paciente com ceratocone, mensurados em um aberrômetro ("wavefront") com sensor Hartmann-Shack, foram determinados as espessuras de lentes de contato que compensam essas aberrações assim como os números de pulsos necessários para fazer ablação as lentes especificamente para este paciente. RESULTADOS: Os mapas de correção são apresentados e os números dos pulsos foram calculados, usando feixes com a largura de 0,5 mm e profundidade de ablação de 0,3 µm. CONCLUSÕES: Os resultados simulados foram promissores, mas ainda precisam ser aprimorados para que o sistema de ablação "real" possa alcançar a precisão desejada.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.
Resumo:
PURPOSE: To evaluate the safety and efficacy of corneal collagen crosslinking (CXL) in patients with painful pseudophakic bullous keratopathy (PBK). SETTING: University of Sao Paulo, Sao Paulo and Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. METHODS: This prospective study included consecutive eyes with PBK that had CXL. After a 9.0 mm epithelial removal, riboflavin 0.1% with dextran 20% was applied for 30 minutes followed by ultraviolet-A irradiation (370 nm, 3 mW/cm(2)). Therapeutic contact lenses were placed for 1 week. Corneal transparency, central corneal thickness (CCT), and ocular pain were assessed preoperatively and 1 and 6 months postoperatively. Statistical analysis was by paired t tests. RESULTS: Fourteen patients (14 eyes) with a mean age 71.14 years +/- 11.70 (SD) (range 53 to 89 years) were enrolled. Corneal transparency was better in all eyes 1 month after surgery. At 6 months, corneal transparency was similar to preoperative levels (P = .218). The mean CCT was 747 mu m preoperatively and 623 mu m at 1 month; the decrease was statistically significant (P<.001). At 6 months, the mean CCT increased to 710 mu m, still significantly thinner than preoperatively (P = .006). Pain scores at 6 months were not significantly different than preoperatively (P = .066). CONCLUSIONS: Corneal CXL significantly improved corneal transparency, corneal thickness, and ocular pain 1 month postoperatively. However, it did not seem to have a long-lasting effect in decreasing pain and maintaining corneal transparency in patients with PBK.
Resumo:
Purpose: To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Methods: Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of −6.00, −3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. Results: In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p < 0.05 in all cases), did not change with the +3.00 soft lens power (p = 1.0); and steepened with the +6.00 soft lens power (p = 0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p > 0.05). RGP’s BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p < 0.001), but no significant differences were found among negative- or positive-powers separately (both p > 0.05). Estimated RGP’s final power increased significantly with positive in comparison with negative lens powers (all p < 0.001), but no significant differences were found among negative or positive lens powers separately (both p > 0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p > 0.05). Conclusion: The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects.
Resumo:
Objective. To evaluate the degree of axial elongation with soft radial refractive gradient (SRRG) contact lenses, orthokeratology (OK), and single vision (SV) spectacle lenses (control) during a period of 1 year before treatment and 2 years after treatment. Methods. This was a prospective, longitudinal, nonrandomized study. The study groups consisted of 30, 29, and 41 children, respectively. The axial length (AL) was measured during 2 years after recruitment and lens fitting. Results. The baseline refractive sphere was correlated significantly (r 2 = 0.542; P < 0.0001) with the amount of myopia progression before baseline. After 2 years, the mean myopia progression values for the SRRG, OK, and SV groups were −0.56 ± 0.51, −0.32 ± 0.53, and −0.98 ± 0.58 diopter, respectively. The results represent reductions in myopic progression of 43% and 67% for the SRRG and OK groups, respectively, compared to the SV group. The AL increased more in the SV group compared to the SRRG and OK groups, with 27% and 38% lower axial elongation, respectively, compared to the SV group at the 2-year visit (P < 0.05). SRRG and OK showed no differences (P = 0.430). Conclusion. The SRRG lens significantly decreased AL elongation compared to the SV control group. The SRRG lens was similarly effective to OK in preventing myopia progression in myopic children and adolescent.
Resumo:
Purpose: To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Methods: Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between ?1.50 and ?2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ)lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January–December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Results: Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. Conclusions: We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment.
Resumo:
Objectives: To evaluate neophyte contact lens wearers’ fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Methods: Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Results: Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.1262.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a signifi- cant increase at 10 days (P,0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Conclusions: Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.
Resumo:
Purpose: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (FT) and sagittal (FS) power errors across the central 70 of the visual field in the horizontal meridian. Methods: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (2.15 ± 1.26D, range: 0.88 to 5.25D). Axial and peripheral refraction were measured along the central 70 of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [MBaseline = 0.88 to 1.50D; n = 11], Group 2 [MBaseline = 1.51 to 2.49D; n = 11], and Group 3 [MBaseline = 2.50 to 5.25D; n = 12]. Results: Spherical equivalent was significantly more myopic after treatment beyond the central 40 of the visual field (p50.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25 (p 0.017), 30 (p 0.007) and 35 (p 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35 in the nasal and temporal retina (p 0.045). Conclusions: Orthokeratology changes significantly FT in the myopic direction beyond the central 40 of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35 of eye rotation were significantly correlated with axial myopia at baseline. Keywords: Field
Resumo:
Among corneal dystrophies, the keratoconus is one of the most frequently observed among young adults. A clinico pathological case is reported in a 13-year-old-girl of African origin. The diagnosis of bilateral keratoconus was established based on the obvious changes of the corneal curvature and thickness. After an unsuccessful attempt to improve vision with contact lenses, a keratoplasty was finally performed on one side to remove the pathological cornea. Its histopathological study found the characteristic changes of keratoconus: breaks of Bowman's layer and corneal thinning.
Resumo:
Various strategies for ocular drug delivery are considered; from basic formulation techniques for improving availability of drugs; viscosity enhancers and mucoadhesives aid drug retention and penetration enhancers promote drug transport into the eye. The use of drug loaded contact lenses and ocular inserts allows drugs to be better placed where they are needed for more direct delivery. Developments in ocular implants gives a means to overcome the physical barriers that traditionally prevented effective treatment. Implant technologies are under development allowing long term drug delivery from a single procedure, these devices allow posterior chamber diseases to be effectively treated. Future developments could bring artificial corneas to eliminate the need for donor tissue and one-off implantable drug depots lasting the patient’s lifetime.
Resumo:
Purpose: We described the rate of Acanthamoeba keratitis (AK) in a referral eye center in Sao Paulo, Brazil, through a retrospective review of clinical and laboratorial records of patients over 2 decades. Methods: From 1987 to 2006, a total of 581 requests for amoebic laboratory workup in cases of infections keratitis were investigated. Statistical analyses were applied to analyze a tendency of AK cases. Results: Acanthamoeba species were cultured from corneal scrapings of 185 patients, 5 of them with bilateral infection. Eighty-three percent of those patients were related with contact lens wear. Conclusions: The results suggested that patients with AK have persisted and increased over time at our ophthalmology center. Contact lenses showed to be a potential risk factor. Amoebic corneal infection can be considered as a new but well-established disease ill Brazilian ophthalmology and visual sciences.
Resumo:
OBJETIVO: Analisar o perfil dos usuários de lentes de contato entre os estudantes de medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), quanto à ametropia, à aquisição, aos cuidados e às complicações. MÉTODOS: Foi aplicado um questionário aos alunos do 1º ao 6º ano de Medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), perfazendo um estudo analítico transversal. RESULTADOS: Foram 566 entrevistados. Destes, 155 (27,4%) usavam lente de contato. Das lentes de contato usadas, 94,8% eram gelatinosas, e em 98,7% o grau era negativo. O descarte dessas lentes era mensal em 46,9% dos entrevistados e 63,9% a utilizavam, em média, 14 horas/dia. Faziam aquisição da lente de contato em óptica ou farmácia 14,1% dos estudantes. Faziam a higiene ao colocá-las e ao retirá-las dos olhos, 46,5%. As complicações referentes aos olhos vermelhos eram 51,0%; 44,5%, embaçamento; e 42,6%, sensação de corpo estranho, além de 4 estudantes relatarem ceratite. CONCLUSÕES: A maioria dos alunos utilizava lentes hidrofílicas, descarte mensal e grau negativo. A adaptação inadequada, aquisição de lentes de contato em ópticas ou farmácias e complicações graves ocorreram, mesmo nos usuários socioculturalmente considerados diferenciados. em vista disso, demanda a extrema necessidade de maior atenção na abordagem do tema em questão, a fim de prevenir o comprometimento visual permanente.
Resumo:
Purpose: To analyze the conditions, consequences and risks of self-medication in patients attended in ophthalmology emergency room at Hospital das Clínicas de Botucatu (UNESP). Methods: Sixty patients who had used any form of self-medication were studied according: age, sex, professional activity, mainly complain, visual acuity (best-corrected vision), who administrated the self-medication (friends/parents, pharmacy clerk, advertisement, or the person himself), sort of medication or product used (eyedrops/ointments/contact lenses), cost (R$), time expenditure to medical attention, ocular complications, risk of visual loss and final diagnose. Results: The majority of patients with self-medication were male (72%). The mean age was 40,9 years (7-77 years). Patients usually used eyedrops that they had at home and delayed 3 days to the first medical evaluation. The most frequently kind of topical eyedrop used was vasoconstrictor (17%). However, many patients even knew what kind of medication they had dropped in their eyes (21%). The great majority of the patients (68%) were exposed to the risk of visual loss. According to our results, self-medication may cause visual complications in 12% of patients, in which, 42% was related to the contact lenses fit without ophthalmologic assistance. Conclusion: The majory of the patients used medication that they had in home. The topical vasoconstrictor was the most frequently used drug, however, they did not know which medication were dropping in their eyes (21%).
Resumo:
Purpose: The aim of this study was to evaluate the roughness of colorless ocular button and four brands of colorless acrylic resins designed to fabricate ocular prosthesis as a function of weathering (1008 h) and different thickness (1 and 3.5 mm). Materials and methods: One-hundred-and-twenty specimens were fabricated and distributed in 12 groups. The analysis was carried out by means of digital roughness meter. Results: Data were analyzed statistically by ANOVA and Tukey test at 1% significance. The results showed that there was no statistically significant difference after the weathering period. Both the Vipi Cril acrylic resin with 3.5 mm in thickness and ocular button with 1 mm in thickness presented the lowest roughness values (0.12. Ra). Conclusion: The roughness of the acrylic resins and the ocular button was not affect by the weathering of 1008 h. However, the thickness of the specimens proved to have a major influence on roughness property. © 2010.