984 resultados para Sight Distances.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Birds frequently interact with people when they occur in coupled human-ecological or anthropogenic environments, which makes the protection of legally protected species a challenge. Flight initiation distances (FIDs) are often used to inform development of appropriate buffer distances required for human exclusion zones used to protect birds nesting in anthropogenic landscapes. Piping Plovers (Charadrius melodus) are protected by the Endangered Species Act in the United States and often nest in areas used by humans. Studies evaluating Piping Plover FIDs are limited and implementation of exclusion zones has been inconsistent across the species’ range. We measured Piping Plover response and FIDs to naturally occurring stimuli on public beaches at Lake McConaughy, Nebraska, USA. Piping Plover FIDs differed most by stimulus class (vehicle, human, dog, human with dog), Julian day, and hour of day. Piping Plover FIDs were greatest for dog and human with dog compared to humans and vehicles. For all types of stimuli, Piping Plover FIDs decreased over time during the nesting season and increased slightly during each day. In the majority of instances in which Piping Plovers left their nests, return times to the nest were relatively short (less than three minutes). These results suggest Piping Plovers become habituated to the presence of human-related stimuli over the course of a nesting season, but other explanations such as parental investment and risk allocation cannot be excluded. Additional research and improved guidance regarding the implementation of exclusion zones is needed so managers can implement effective protection programs in anthropogenic landscapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equations are presented for the avereage internuclear distance r(g) and r(a) in terms of elements of the L matrix and the L tensor. These are an alternative to the equations presented by Kuchitsu and Morino.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is reported in the literature that distances from the observer are underestimated more in virtual environments (VEs) than in physical world conditions. On the other hand estimation of size in VEs is quite accurate and follows a size-constancy law when rich cues are present. This study investigates how estimation of distance in a CAVETM environment is affected by poor and rich cue conditions, subject experience, and environmental learning when the position of the objects is estimated using an experimental paradigm that exploits size constancy. A group of 18 healthy participants was asked to move a virtual sphere controlled using the wand joystick to the position where they thought a previously-displayed virtual cube (stimulus) had appeared. Real-size physical models of the virtual objects were also presented to the participants as a reference of real physical distance during the trials. An accurate estimation of distance implied that the participants assessed the relative size of sphere and cube correctly. The cube appeared at depths between 0.6 m and 3 m, measured along the depth direction of the CAVE. The task was carried out in two environments: a poor cue one with limited background cues, and a rich cue one with textured background surfaces. It was found that distances were underestimated in both poor and rich cue conditions, with greater underestimation in the poor cue environment. The analysis also indicated that factors such as subject experience and environmental learning were not influential. However, least square fitting of Stevens’ power law indicated a high degree of accuracy during the estimation of object locations. This accuracy was higher than in other studies which were not based on a size-estimation paradigm. Thus as indirect result, this study appears to show that accuracy when estimating egocentric distances may be increased using an experimental method that provides information on the relative size of the objects used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that the affective experience of touch and the sight of touch can be modulated by cognition, and investigate in an fMRI study where top-down cognitive modulations of bottom-up somatosensory and visual processing of touch and its affective value occur in the human brain. The cognitive modulation was produced by word labels, 'Rich moisturizing cream' or 'Basic cream', while cream was being applied to the forearm, or was seen being applied to a forearm. The subjective pleasantness and richness were modulated by the word labels, as were the fMRI activations to touch in parietal cortex area 7, the insula and ventral striatum. The cognitive labels influenced the activations to the sight of touch and also the correlations with pleasantness in the pregenual cingulate/orbitofrontal cortex and ventral striatum. Further evidence of how the orbitofrontal cortex is involved in affective aspects of touch was that touch to the forearm [which has C fiber Touch (CT) afferents sensitive to light touch] compared with touch to the glabrous skin of the hand (which does not) revealed activation in the mid-orbitofrontal cortex. This is of interest as previous studies have suggested that the CT system is important in affiliative caress-like touch between individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of this study was to compare and evaluate bone and soft tissue levels between immediately placed, immediately restored implants positioned in the esthetic anterior region with different interimplant distances (IID). Methods: Forty-nine patients requiring multiple implant restorations in the anterior regions received 152 implants, which were restored immediately. Periapical radiographs and digital images of 99 interimplant sites were taken at the regular follow-up examinations at 0, 6, 12, and 24 months after surgery. They were digitally recorded and analyzed. The presence of the interproximal papilla was assessed and compared to the distances between the bone crest and the contact point between the natural teeth and the restoration crowns. Results: Implants with an IID <2 mm seemed to lose less bone laterally. When the IID was <2 mm, vertical crestal bone loss was significantly greater than in the group with IID >4 mm. The percentage of the interproximal papilla presence decreased when the distance between the bone crest and the contact point between the two restoration crowns was >6 mm and when two implants were placed at a distance >= 4 mm. Conclusions: To guarantee a better esthetic result in immediately placed, immediately restored implants, the contact point between the two prosthetic crowns should be placed at 3 to 4 mm, and never >6 mm, from the bone peak. Two adjacent implants should be placed at a distance >2 and <4 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the factors that contribute to the papilla formation and crestal bone preservation between contiguous implants, this animal study clinically and radiographically evaluated the interimplant distances (IDs) of 2 and 3 mm and the placement depths of Morse cone connection implants restored with platform switch. Bilateral mandibular premolars of 6 dogs were extracted, and after 12 weeks, the implants were placed. Four experimental groups were constituted: subcrestally with ID of 2 mm (2 SCL) and 3 mm (3 SCL) and crestally with ID of 2 mm (2 CL) and 3 mm (3 CL). Metallic crowns were immediately installed with a distance of 3 mm between the contact point and the bone crest. Eight weeks later, clinical measurements were performed to evaluate papilla formation, and radiographic images were taken to analyze the crestal bone remodeling. The subcrestal groups achieved better levels of papillae formation when compared with the crestal groups, with a significant difference between the 3 SCL and 3 CL groups (P = .026). Radiographically, the crestal bone preservation was also better in the subcrestal groups, with statistically significant differences between the 2SCL and 2CL groups (P = .002) and between the 3SCL and 3CL groups (P = .008). With the present conditions, it could be concluded that subcrestal implant placement had a positive impact on papilla formation and crestal bone preservation, which could favor the esthetic of anterior regions. However, the IDs of 2 and 3 mm did not show significantly different results.