531 resultados para Shoe Inserts


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Genealogy reaching back to his great-grandparents in 18th century; history of the family's wine business until its liquidation in 1931; primary and secondary education; military service; activities in various associations; president of the "Israelitische Oberkirchenbehoerde" (Federation of Wuerttemberg Jewish communities); information about Stuttgart Jewish community.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seizure resistance of several cast aluminium base alloys has been examined using a standard Hohman Wear Tester. Disks of aluminium base alloys were run against a standard aluminium 12% silicon base alloy. The seizure resistance of the alloys (as measured by the lowest bearing parameter reached before seizure) increased with hardness, yield and tensile strength. In Al-Si-Ni alloys where silicon and nickel have little solid solubility in α-aluminium and Si and Ni Al3 hard phases are formed, the minimum bearing parameter decreased with the parameter V (The product of vol. % of hard phases in the disk and the shoe). Apparently the silicon and NiAl3 particles provided discontinuities in the matrix and reduced the probability (1 − V) of the α-aluminium phase in the disk coming into contact with the α-aluminium phase in the shoe. The copper and magnesium containing Al-Si-Ni alloys with lesser volumes of hard phases exhibit considerably better seizure resistance indicating that a slight increase in the solute content or the hardness of the primary α-phase leads to a considerable increase in seizure resistance. Deformation during wear and seizure leads to fragmentation of the original hard particles into considerably smaller particles uniformly dispersed in the deformed α-aluminium matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two backward facing step (2 mm and 3 mm step height) models are selected for surface heat transfer measurements. The platinum thin film gauges are deposited on the Macor inserts using both hand paint and vacuum sputtering technique. Using the Eckert reference temperature method the heating rates has been theoretically calculated along the flat plate portion of the model and the theoretical estimates are compared with experimentally determined surface heat transfer rate. Theoretical analysis of heat flux distribution down stream of the backward facing step model has been carried out using Gai’s non-dimensional analysis. Based on the measured surface heating rates on the backward facing step, the reattachment distance is estimated for 2 and 3 mm step height at nominal Mach number of 7.6. It has been found from the present study that for 2 and 3 mm step height, it approximately takes about 10 and 8 step heights downstream of the model respectively for the flow to re-attach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to investigate the use of custom-made orthopedic shoes (OS) and the association between the use of OS and the most relevant aspects of their usability. Over a 6-month period, patients meeting the inclusion criteria were recruited by 12 orthopedic shoe companies scattered throughout the Netherlands and asked to complete a questionnaire composed of a pre- and post-OS section. Patients with different pathologies were included in the study (n = 339; response 67%). Mean age of the patients was 63 +/- 15 years, and 38% were male. Three months after delivery, 81% of the patients used their OS frequently (4-7 days/week), 13% occasionally (1-3 days/week), and 6% did not use their OS. Associations were found between use and all measured aspects of usability (p-values varied from <0.001 to 0.028). Patients who used their OS more often had a more positive opinion regarding all the aspects of usability. We conclude that all aspects of the usability of OS are relevant in relation to their use and should be taken into account when prescribing and evaluating OS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To investigate the association between patients' expectations and the actual use of custom-made orthopaedic shoes. Design: A prospective cohort study with internal comparison. Setting: Twelve orthopaedic shoe companies. Patients: During six months, consecutive patients who were provided with their first ever pair of orthopaedic shoes and aged 16 years or older were recruited. A total of 339 patients with different pathologies were included (response 67%). Mean (SD) age of the patients was 63 (15) years, and 129 patients (38%) were male. Main measures: A practical and reproducible questionnaire, measuring: frequency of use of orthopaedic shoes, patients' expectations and experiences of aspects of the usability of orthopaedic shoes, and communication about patients' expectations. Results: Patients' expectations were not associated with the use of orthopaedic shoes (P-values range: 0.106 to 0.607), but the difference between expectations and experiences was (P-values range: <0.001 to 0.012). The expectations of patients who frequently used their orthopaedic shoes were in concordance with their experiences, whereas the expectations of patients who did not use their orthopaedic shoes were much higher than their experiences. There was no communication of patients' expectations with the medical specialist or orthopaedic shoe technician in 34% and 25% of the patients respectively. Conclusions: In relation to the actual use of orthopaedic shoes, it is crucial that patients' expectations are not much higher than their experiences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated long-term use of custom-made orthopedic shoes (OS) at 1.5 years follow-up. In addition, the association between short-term outcomes and long-term use was studied. Patients from a previously published study who did use their first-ever pair of OS 3 months after delivery received another questionnaire after 1.5 years. Patients with different pathologies were included in the study (n = 269, response = 86%). Mean age was 63 ± 14 years, and 38% were male. After 1.5 years, 87% of the patients still used their OS (78% frequently [4-7 days/week] and 90% occasionally [1-3 days/week]) and 13% of the patients had ceased using their OS. Patients who were using their OS frequently after 1.5 years had significantly higher scores for 8 of 10 short-term usability outcomes (p-values ranged from <0.001 to 0.046). The largest differences between users and nonusers were found for scores on the short-term outcomes of OS fit and communication with the medical specialist and shoe technician (effect size range = 0.16 to 0.46). We conclude that patients with worse short-term usability outcomes for their OS are more likely to use their OS only occasionally or not at all at long-term follow-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Binaural experiments are described which indicate that the ability of the brain to localize a desired sound and to suppress undesired sounds coming from other directions can be traced in part to the different times of arrival of a sound at the two ears. It is suggested that the brain inserts a time delay in one of the two nerve paths associated with the ears so as to be able to compare, and thus concentrate on, those sounds arriving at the ears with this particular time of arrival distance.The ability to perceive weak sounds binaurally in the presence of noise is shown to be a simple function of the direction of the desired sound and noise. An explanation is given for the effect reported by Koenig that front and rear confusion is avoided by head movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The random direction short Glass Fiber Reinforced Plastics (GFRP) have been prepared by two compression moulding processes, namely the Preform and Sheet Moulding Compound (SMC) processes. Cutting force analysis and surface characterization are conducted on the random direction short GFRPs with varying fiber contents (25 similar to 40%). Edge trimming experiments are preformed using carbide inserts with varing the depth of cut and cutting speed. Machining characteristics of the Preform and SMC processed random direction short GFRPs are evaluated in terms of cutting forces, surface quality, and tool wear. It is found that composite primary processing and fiber contents are major contributing factors influencing the cutting force magnitudes and surface textures. The SMC composites show better surface finish over the Preform composites due to less delamination and fiber pullouts. Moreover, matrix damage and fiber protrusions at the machined edge are reduced by increasing fiber content in the random direction short GFRP composites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report in this paper the aggregation properties of amphotericin-B (amp-B) in solution using CD and 1H-NMR techniques. Our results indicate that the preferred structure of amp-B in dimethylsulfoxide is a monomer at low concentrations (10−4M and below) and a stable dimer at higher concentrations (range 5 · 103 M to 10−2M). In a DMSO/ethanol mixture (1:1 (v/v)), the antibiotic is monomeric, irrespective of the concentration within the range studied. We propose a head-to-tail model based on NMR data. An understanding of the head-to-tail dimer, is, we believe important, particularly in view of the recent report wherein it is proposed that the drug inserts into bilayers as head-to-tail oligomers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The entry of the plant toxin ricin and its A- and B-subunits in model membranes in the presence as well as absence of monosialoganglioside (GM(1)) has been studied. Dioleoylphosphatidylcholine and 5-, 10-, and 12-doxyl- or 9,10-dibromophosphatidylcholines serve as quenchers of intrinsic tryptophan fluorescence of the proteins. The parallax method of Chattopadhyay and London [(1987) Biochemistry 26, 39-45] has been employed to measure the average membrane penetration depth of tryptophans of ricin and its B-chain and the actual depth of the sole Trp 211 in the A-chain. The results indicate that both of the chains as well as intact ricin penetrate the membrane deeply and the C-terminal end of the A-chain is well inside the bilayer, especially at pH 4.5. An extrinsic probe N-(iodoacetyl)-N'-(5-sulfo-1-naphthyl) ethylenediamine (I-AEDANS) has been attached to Cys 259 of the A-chain, and the kinetics of penetration has been followed by monitoring the increase in AEDANS fluorescence at 480 nm. The insertion follows first-order kinetics, and the rate constant is higher at a lower pH. The energy transfer distance analysis between Trp 211 and AEDANS points out that the conformation of the A-chain changes as it inserts into the membrane. CD studies indicate that the helicity of the proteins increases after penetration, which implies that some of the unordered structure in the native protein is converted to the ordered form during this process. Hydrophobic forces seem to be responsible for stabilizing a particular protein conformation inside the membrane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A previous study on the tribological performance of a compression-moulded aramid fibre-phenolic resin composite, containing 30% continuous fibre, showed that this composite provides a reasonable combination of the friction coefficient and wear rate to be used as a friction component, such as a brake shoe. In the present work, the effect of sliding speed on the friction and wear behaviour of this composite has been investigated. The sliding experiments were conducted in a speed range of 0.1-6 m s(-1) at two normal pressure levels of 1.0 and 4.9 MPa. The coefficient of friction was found to be stable over a wide range of sliding speeds and normal pressures. The wear of the composite was found to be insensitive to changes in the speed in the higher speed range. The results have been supplemented with scanning electron micrographs to help understand possible friction and wear mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two backward-facing models with step heights of 2 and 3 mm are used to measure the convective surface heat transfer rates by using platinum thin-film gauges, deposited on Macor inserts. Heat transfer rates have been theoretically calculated along the flat plate portion of a model using the Eckert reference temperature method. The experimentally determined surface heat transfer rate distributions are compared with theoretical and numerical estimations. Experimental heat flux distribution over a flat plate model showed good agreement with the reference temperature method at stagnation enthalpy range of 0.8-2 MJ/kg. Theoretical analysis has been used for downstream of a backward-facing step using Gai's nondimensional analysis. It has been found from the present study that approximately 10 and 8 step heights are required for the flow to reattach for 2 and 3 mm step height backward-facing step models, respectively, at a nominal Mach number of 7.6.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an open-source, realtime, embedded implementation of a foot-mounted, zero-velocity-update-aided inertial navigation system. The implementation includes both hardware design and software, uses off-the-shelf components and assembly methods, and features a standard USB interface. The software is written in C and can easily be modified to run user implemented algorithms. The hardware design and the software are released under permissive open-source licenses and production files, source code, documentation, and further resources are available at www.openshoe.org. The reproduction cost for a single unit is below $800, with the inertial measurement unit making up the bulk ($700). The form factor of the implementation is small enough for it to be integrated in the sole of a shoe. A performance evaluation of the system shows a position errors for short trajectories (<;100 [m]) of ± 0.2-1% of the traveled distance, depending on the shape of trajectory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shoe-mounted inertial sensors offer a convenient way to track pedestrians in situations where other localization systems fail. This tutorial outlines a simple yet effective approach for implementing a reasonably accurate tracker. This Web extra presents the Matlab implementation and a few sample recordings for implementing the pedestrian inertial tracking system using an error-state Kalman filter for zero-velocity updates (ZUPTs) and orientation estimation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heat fluxes around short, three-dimensional protuberances on sharp and blunt cones in hypersonic flow were experimentally measured using platinum thin-film sensors deposited on macor inserts. A parametric study of different protrusion geometries and flow conditions were conducted. Excessive heating was observed at locations near the protrusion where increased vorticity is expected, with the hottest spot being presented at the foot of the protuberance immediately upstream of it. If left unchecked, these hot spots could prove detrimental to hypersonic flight vehicles. Z-type schlieren technique was used to visualize the flow features qualitatively. New correlations to predict the heat flux at the hot spot have been proposed. (C) 2014 Elsevier Inc. All rights reserved.