320 resultados para Shaft


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Trichothiodistrophy (TTD) is a rare autosomal recessive condition that is characterized by a specific congenital hair shaft dysplasia caused by deficiency of sulfur associated with a wide spectrum of multisystem abnormalities. In this article, we study clinical, microscopic, and ultrastructural findings of 20 patients with TTD with the aim to add further insights regarding to this rare condition. Additionally, analyses of our results are compared with those extracted from the literature in order to enhance its comprehensibility. Materials and Methods: Twenty cases of TTD were included: 7 from Mexico and 14 from Spain. Clinical, microscopic, scanning electron microscopy (SEM) studies and X-ray microanalysis (XrMa) were carried out in all of them. Genetic studies were performed in all seven Mexican cases. Patients with xeroderma pigmentosum and xeroderma pigmentosum/TTD-complex were excluded. Results: Cuticular changes and longitudinal crests of the hair shaft were demonstrated. These crests were irregular, disorganized, following the hair longest axis. Hair shaft sulfur deficiency was disposed discontinuously and intermittently rather than uniformly. This severe decrease of sulfur contents was located close to the trichoschisis areas. Only five patients did not show related disturbances. Micro-dolichocephaly was observed in five cases and represented the most frequent facial dysmorphism found. It is also remarkable that all patients with urologic malformations also combined diverse neurologic disorders. Moreover, three Mexican sisters demonstrated the coexistence of scarce pubic vellus hair, developmental delay, onychodystrophy, and maxillar/mandibullar hypoplasia. Conclusions: TTD phenotype has greatly varied from very subtle forms to severe alterations such as neurologic abnormalities, blindness, lamellar ichthyosis and gonadal malformations. Herein, a multisystem study should be performed mandatorily in patients diagnosed with TTD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nyky yhteiskunta tulee päivä päivältä riippuvaisemmaksi sähköstä ja sen luotettavasta siirrosta ja jakelusta. Suurhäiriö kantaverkossa on erittäin epätodennäköinen, mutta sen mahdollisuutta ei koskaan voida kokonaan rajata pois. Suurhäiriön seuraukset ovat erittäin vakavat ja yhteiskäytön palautus häiriön jälkeen voi pitkittyä. Diplomityössä käsitellään kantaverkkoyhtiö Fingrid Oyj:n kaasuturpiinivaravoimalaitoksia ja niiden ominaisuuksia kantaverkon suurhäiriössä. Varavoimalaitosten pimeäkäynnistysvalmiudet tarkastettiin ja niissä suoritettiin koeajoja, jotka sisälsivät jatkuvan ja dynaamisen tilan koeajo osuudet. Yhdessä laitosyksikössä tehtiin myös pimeäkäynnistys ja saarekekoeajo. Koeajojen perusteella saatiin arvokasta perustietoa kaasuturpiinilaitosten ominaisuuksista ja mahdollisuuksista toimia pimeäkäynnistystilanteissa. Varavoimalaitosten matemaattista mallintamista yksinkertaisella teollisuuskaasuturpiinilaitoksen mallilla kokeiltiin siinä kuitenkaan onnistumatta. Kokemusten perusteella esitetään keskeisimmät havainnot ja ehdotukset kevyen, moniakselisen kaasuturpiinilaitoksen mallintamiseksi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pumppukäytöt vastaavat noin neljännestä Euroopan alueen sähkömoottoreissa kuluvasta energiasta. Energian hinnan nousun vuoksi energian säästäminen ja energiatehokkuus ovat nousseet tärkeään asemaan paljon energiaa kuluttavassa teollisuudessa. Pumppukäyttöjen hyötysuhteen parantaminen on noussut olennaiseen osaan paperi- ja kartonkiteollisuuden energiatehokkuustarkasteluissa. Tässä työssä tarkastellaan kartonkikoneen pumppukäyttöjen toiminnan energiatehokkuutta moottorin virtamittausten perusteella. Analyysi perustuu moottorin akselitehon määrittämiseen ja sen perusteella tehtävään pumpun toimintapisteen laskentaan. Työssä esitellään käytetyt estimointimenetelmät ja niillä saadut tulokset kartonkikoneen pumppukäytöille. Lisäksi työssä arvioidaan kolmen yksittäisen pumppukäytön energiankulutuksen säästöpotentiaalia. Työssä käytettyä menetelmää voidaan käyttää sekä vakio- että vaihtonopeuspumppukäyttöjen toiminnan ja hyötysuhteen analysointiin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tämä diplomityö on osa FCEP hankeen Lappeenrannan teknillisessä yliopistossa tehtävää tutkimusta polttomoottoreiden energiatehokkuuden parantamisesta. Työn tavoitteena on saada tutkimustietoa polttomoottoreiden hukkalämpövirtojen hyödyntämisestä sähköntuotannossa. Tavoitteena on kartoittaa polttomoottorin hukkalämpövirtojen sähköksi muunnon potentiaalia valituilla menetelmillä ja tekniikoilla. Työssä tarkasteltavaksi moottoriksi valittiin DF- monipolttoainemoottori. DF-moottorin polttoaineena voidaan käyttää joko kaasua tai polttoöljyä. Laskennat suoritettiin moottorin valmistajan antamien hukkalämpövirtojen arvojen ja moottorin lämpötaseen avulla. Laskennan perusperiaatteena oli vesihöyryprosessin ja ORC-prosessien vertailu pakokaasulämmön hyödyntämisessä sekä matalalämpöisten hukkalämpövirtojen hyödyntäminen ORC-prosesseilla. Lisäksi työssä tutkittiin korkealla painesuhteella ja korkealla hyötysuhteella toimivan turboahtimen vaikutusta hukkalämpövirroista saatavaan tehoon. Diplomityössä tarkasteltiin moottorin lämpötaseen mukaisten arvojen lisäksi moottorin parametrien muuttamisen vaikutusta hukkalämpövirroista saatavaan tehoon. Moottorin parametrien muuttamisen vaikutusta moottorin akselitehoon tai moottorin lämpötaseeseen ei kuitenkaan tämän tutkimuksen puitteissa tarkasteltu. Työssä saatiin arvokasta tietoa polttomoottoreiden hukkalämpövirtojen muuntamisesta sähköksi eri menetelmillä sekä moottorin energiatehokkuuden parantamisesta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high-speed and high-voltage solid-rotor induction machine provides beneficial features for natural gas compressor technology. The mechanical robustness of the machine enables its use in an integrated motor-compressor. The technology uses a centrifugal compressor, which is mounted on the same shaft with the high-speed electrical machine driving it. No gearbox is needed as the speed is determined by the frequency converter. The cooling is provided by the process gas, which flows through the motor and is capable of transferring the heat away from the motor. The technology has been used in the compressors in the natural gas supply chain in the central Europe. New areas of application include natural gas compressors working at the wellheads of the subsea gas reservoir. A key challenge for the design of such a motor is the resistance of the stator insulation to the raw natural gas from the well. The gas contains water and heavy hydrocarbon compounds and it is far harsher than the sales gas in the natural gas supply network. The objective of this doctoral thesis is to discuss the resistance of the insulation to the raw natural gas and the phenomena degrading the insulation. The presence of partial discharges is analyzed in this doctoral dissertation. The breakdown voltage of the gas is measured as a function of pressure and gap distance. The partial discharge activity is measured on small samples representing the windings of the machine. The electrical field behavior is also modeled by finite element methods. Based on the measurements it has been concluded that the discharges are expected to disappear at gas pressures above 4 – 5 bar. The disappearance of discharges is caused by the breakdown strength of the gas, which increases as the pressure increases. Based on the finite element analysis, the physical length of a discharge seen in the PD measurements at atmospheric pressure was approximated to be 40 – 120 m. The chemical aging of the insulation when exposed to raw natural gas is discussed based on a vast set of experimental tests with the gas mixture representing the real gas mixture at the wellhead. The mixture was created by mixing dry hydrocarbon gas, heavy hydrocarbon compounds, monoethylene glycol, and water. The mixture was chosen to be more aggressive by increasing the amount of liquid substances. Furthermore, the temperature and pressure were increased, which resulted in accelerated test conditions. The time required to detect severe degradation was thus decreased. The test program included a comparison of materials, an analysis of the e ects of di erent compounds in the gas mixture, namely water and heavy hydrocarbons, on the aging, an analysis of the e ects of temperature and exposure duration, and also an analysis on the e ect of sudden pressure changes on the degradation of the insulating materials. It was found in the tests that an insulation consisting of mica, glass, and epoxy resin can tolerate the raw natural gas, but it experiences some degradation. The key material in the composite insulation is the resin, which largely defines the performance of the insulation system. The degradation of the insulation is mostly determined by the amount of gas mixture di used into it. The di usion was seen to follow Fick’s second law, but the coe cients were not accurately defined. The di usion was not sensitive to temperature, but it was dependent upon the thermodynamic state of the gas mixture, in other words, the amounts of liquid components in the gas. The weight increase observed was mostly related to heavy hydrocarbon compounds, which act as plasticizers in the epoxy resin. The di usion of these compounds is determined by the crosslink density of the resin. Water causes slight changes in the chemical structure, but these changes do not significantly contribute to the aging phenomena. Sudden changes in pressure can lead to severe damages in the insulation, because the motion of the di used gas is able to create internal cracks in the insulation. Therefore, the di usion only reduces the mechanical strength of the insulation, but the ultimate breakdown can potentially be caused by a sudden drop in the pressure of the process gas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityössä on esitelty ja tutkittu laakerivirtailmiötä sähkökoneissa. Työn pääpaino on suurissa kestomagneettitahtikoneissa, joissa niin sanotut kiertävät laakerivirrat ovat dominoivia. Työssä on lisäksi tarkasteltu staattorin segmentoinnin aiheuttamia matalataajuisia kiertovirtoja. Laakerivirran ja akselijännitteen ehkäisyyn on esitetty sekä testattu mahdollisia ratkaisuja.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to model mathematically and to simulate the dynamic behavior of an auger-type fertilizer applicator (AFA) in order to use the variable-rate application (VRA) and reduce the coefficient of variation (CV) of the application, proposing an angular speed controller θ' for the motor drive shaft. The input model was θ' and the response was the fertilizer mass flow, due to the construction, density of fertilizer, fill factor and the end position of the auger. The model was used to simulate a control system in open loop, with an electric drive for AFA using an armature voltage (V A) controller. By introducing a sinusoidal excitation signal in V A with amplitude and delay phase optimized and varying θ' during an operation cycle, it is obtained a reduction of 29.8% in the CV (constant V A) to 11.4%. The development of the mathematical model was a first step towards the introduction of electric drive systems and closed loop control for the implementation of AFA with low CV in VRA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT The power consumption and load capacity of agricultural machines have grown and the effects of pressure on the soil by tires have been still little investigated. In concern with sustainable development, the relationship machine-tire-soil must be in balance to give more consistency on the best use of tires for a given load. This study aimed to evaluate four tires of two constructive types, the bias belted tires and radial tires, both with respective rim diameters of 22.5 and 26.5 inches with variables measuring the footprint, elastic deformation, sinkage and resistance to penetration. A hydraulic press with an attachment shaft for tire mounting and a box of soil in which the tire has been imposed on a load of 53.00 kN using nominal pressures recommended by the tire manufacturer. The radial construction tire with rim diameter of 26.5 inches obtained less sinkage and resistance to penetration; however, greater elastic deformation and footprint compared to other tires. The bias-belted tire with 22.5-inch rim presented the highest resistance to penetration and the lowest elastic deformation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This master’s thesis mainly focuses on the design requirements of an Electric drive for Hybrid car application and its control strategy to achieve a wide speed range. It also emphasises how the control and performance requirements are transformed into its design variables. A parallel hybrid topology is considered where an IC engine and an electric drive share a common crank shaft. A permanent magnet synchronous machine (PMSM) is used as an electric drive machine. Performance requirements are converted into Machine design variables using the vector model of PMSM. Main dimensions of the machine are arrived using analytical approach and Finite Element Analysis (FEA) is used to verify the design and performance. Vector control algorithm was used to control the machine. The control algorithm was tested in a low power PMSM using an embedded controller. A prototype of 10 kW PMSM was built according to the design values. The prototype was tested in the laboratory using a high power converter. Tests were carried out to verify different operating modes. The results were in agreement with the calculations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Centrifugal pumps are a notable end-consumer of electrical energy. Typical application of a centrifugal pump is the filling or emptying of a reservoir tank, where the pump is often operated at a constant speed until the process is completed. Installing a frequency converter to control the motor substitutes the traditional fixed-speed pumping system, allows the optimization of rotational speed profile for the pumping tasks and enables the estimation of rotational speed and shaft torque of an induction motor without any additional measurements from the motor shaft. Utilization of variable-speed operation provides the possibility to decrease the overall energy consumption of the pumping task. The static head of the pumping process may change during the pumping task. In such systems, the minimum rotational speed changes during reservoir filling or emptying, and the minimum energy consumption can’t be achieved with a fixed rotational speed. This thesis presents embedded algorithms to automatically identify, optimize and monitor pumping processes between supply and destination reservoirs, and evaluates the changing static head –based optimization method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä väitöskirjassa tarkastellaan suurnopeustekniikan eri sovelluksissa ilmeneviä roottoreihin liittyviä rakenteellisia vaatimuksia ja haasteita. Tässä yhteydessä suurnopeustekniikalla tarkoitetaan järjestelyä, jossa sähkökone (moottori, generaattori) ja toimilaite (turbiini, kompressori, puhallin) on kytketty ilman vaihdetta suoraan mekaanisesti yhteen ja jossa yhteisen roottorin pyörimisnopeus on selvästi suurempi kuin 50/60 hertsin verkosta syötetyn kaksinapaisen vaihtovirtasähkökoneen tahtinopeus. Tyypillistä suurnopeuskoneen roottorille on suuri tehotiheys ja suuri mekaaninen kuormitus. Siksi esimerkiksi sähkökoneen jäähdytys on entistä haasteellisempaa kasvavien rautahäviöiden ja pienempien lämmönsiirtopinta-alojen vuoksi. Tämän työn tavoitteet voidaan jakaa kolmeen osaan:  Yhdistetyn sähkö- ja turbokoneen roottorin mekaanisen rakenteen tarkastelu, jonka tavoitteena on pienentää lämmönkehitystä ja tehostaa kriittisten kohtien jäähdytystä. Tähän liittyy sähkömagneettisten häviöiden keskittäminen jäähdytyksen kannalta edullisiin kohtiin  Yhdistetyn sähkö- ja turbokoneen roottorin mekaanisen rakenteen tarkastelu kriittisten ominaistaajuuksien kannalta  Yhdistetyn sähkö- ja turbokoneen roottorin mekaanisen rakenteen analysointi lujuustekniseltä kannalta. Tähän liittyvät mm. erilaiset ahdistussovitteet ja niiden säilyminen korkeilla pyörimisnopeuksilla sekä niiden roottoria jäykistävä vaikutus ja lämmön johtuminen kyseisissä liitospinnoissa. Tämän työn tieteellinen uutuusarvo on nimenomaan yhdistetyn sähkö- ja turbokoneen roottorin rakenteen analysointi ottamalla samanaikaisesti huomioon kaikki edellä mainitut näkökohdat: jäähtyminen erityisen kuumissa kohdissa, sähköisten häviöiden alentaminen ja niiden jakautuman huomioon ottaminen, roottorin jäykkyyden maksimointi, lujuusrasitusten hallinta ja rakenteen mekaaninen stabiliteetti sekä lämpöteknisten ylimenovastusten tarkastelu.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ride comfort of elevators is one of the quality criteria valued by customers. The objective of this master’s thesis was to develop a process to measure the ride comfort of automatic elevator doors. The door’s operational noise was chosen as a focus area and other kinds of noise for example caused by pressure differences in the elevator shaft were excluded. The thesis includes a theory part and an empirical part. In the first part theories of quality management, measuring of quality and acoustics are presented. In the empirical part the developed ride comfort measuring process is presented, different operational noise sources are analyzed and an example is presented of how this measuring process can be used to guide product development. To measure ride comfort a process was developed where a two-room silent room was used as a measuring environment and EVA-625 device was used in the actual measuring of door noise. A-weighted decibels were used to scale noise pressure levels and the door movement was monitored with an accelerometer. This enabled the connection between the noise and noise sources which in turn helped to find potential ride comfort improvement ideas. The noise isolation class was also measured with the Ivie-measuring system. Measuring of door ride comfort gives feedback to product development and to managing current product portfolio. Measuring enables the continuous improvement of elevator door ride comfort. The measuring results can also be used to back up marketing arguments for doors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.