978 resultados para Sensitive Development
Resumo:
Hepatitis E virus (HEV) is classified within the family Hepeviridae, genus Hepevirus. HEV genotype 3 (Gt3) infections are endemic in pigs in Western Europe and in North and South America and cause zoonotic infections in humans. Several serological assays to detect HEV antibodies in pigs have been developed, at first mainly based on HEV genotype 1 (Gt1) antigens. To develop a sensitive HEV Gt3 ELISA, a recombinant baculovirus expression product of HEV Gt3 open reading frame-2 was produced and coated onto polystyrene ELISA plates. After incubation of porcine sera, bound HEV antibodies were detected with anti-porcine anti-IgG and anti-IgM conjugates. For primary estimation of sensitivity and specificity of the assay, sets of sera were used from pigs experimentally infected with HEV Gt3. For further validation of the assay and to set the cutoff value, a batch of 1100 pig sera was used. All pig sera were tested using the developed HEV Gt3 assay and two other serologic assays based on HEV Gt1 antigens. Since there is no gold standard available for HEV antibody testing, further validation and a definite setting of the cutoff of the developed HEV Gt3 assay were performed using a statistical approach based on Bayes' theorem. The developed and validated HEV antibody assay showed effective detection of HEV-specific antibodies. This assay can contribute to an improved detection of HEV antibodies and enable more reliable estimates of the prevalence of HEV Gt3 in swine in different regions.
Resumo:
In recent years, technological advancements in microelectronics and sensor technologies have revolutionized the field of electrical engineering. New manufacturing techniques have enabled a higher level of integration that has combined sensors and electronics into compact and inexpensive systems. Previously, the challenge in measurements was to understand the operation of the electronics and sensors, but this has now changed. Nowadays, the challenge in measurement instrumentation lies in mastering the whole system, not just the electronics. To address this issue, this doctoral dissertation studies whether it would be beneficial to consider a measurement system as a whole from the physical phenomena to the digital recording device, where each piece of the measurement system affects the system performance, rather than as a system consisting of small independent parts such as a sensor or an amplifier that could be designed separately. The objective of this doctoral dissertation is to describe in depth the development of the measurement system taking into account the challenges caused by the electrical and mechanical requirements and the measurement environment. The work is done as an empirical case study in two example applications that are both intended for scientific studies. The cases are a light sensitive biological sensor used in imaging and a gas electron multiplier detector for particle physics. The study showed that in these two cases there were a number of different parts of the measurement system that interacted with each other. Without considering these interactions, the reliability of the measurement may be compromised, which may lead to wrong conclusions about the measurement. For this reason it is beneficial to conceptualize the measurement system as a whole from the physical phenomena to the digital recording device where each piece of the measurement system affects the system performance. The results work as examples of how a measurement system can be successfully constructed to support a study of sensors and electronics.
Resumo:
Seeds of Magnolia ovata were dried to different water contents to assess the viability and transcript abundance of genes related to seed development, cell cycle, cytoskeleton and desiccation tolerance.The expression of development, cell cycle and cytoskeleton relative genes (ABI3, CDC2-like and ACT2) alone could not explain the germination behaviour of M. ovata seeds in relation to drying damage. Irrespective of their initial water content, the seeds performed in the same way during the initial period of germination and the deleterious effects of desiccation only occurred in later stages. Expression of PKABA1, sHSP17.5 and 2-Cys-PRX did not show a relationship with desiccation. However, the expression patterns of PKABA1 and sHSP17.5 suggested the participation of these genes in protective mechanisms during the imbibition of M. ovata seeds.
Resumo:
Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.
Resumo:
La neuropathie humaine sensitive et autonome de type 2 (NHSA 2) est une pathologie héréditaire rare caractérisée par une apparition précoce des symptômes et une absence d’affectation motrice. Cette pathologie entraîne la perte de perception de la douleur, de la chaleur et du froid ainsi que de la pression (toucher) dans les membres supérieurs et inférieurs et est due à des mutations autosomales récessives confinées à l’exon HSN2 de la protéine kinase à sérine/thréonine WNK1 (with-no-lysine protein kinase 1). Cet exon spécifique permettrait de conférer une spécificité au système nerveux à l’isoforme protéique WNK1/HSN2. La kinase WNK1 est étudiée en détails, en particulier au niveau du rein, mais son rôle au sein du système nerveux demeure inconnu. Considérant le début précoce de la neuropathie et le manque d’innervation sensorielle révélé par des biopsies chez les patients NHSA2, notre hypothèse de recherche est que les mutations tronquantes menant à la NHSA de type 2 causent une perte de fonction de l’isoforme WNK1/HSN2 spécifique au système nerveux entraînant un défaut dans le développement du système nerveux sensoriel périphérique. Chez l’embryon du poisson zèbre, WNK1/HSN2 est exprimé au niveau des neuromastes de la ligne latérale postérieure, un système mécanosensoriel périphérique. Nous avons obtenu des embryons knockdown pour WNK1/HSN2 par usage d’oligonucléotides morpholino antisens (AMO). Nos trois approches AMO ont révélé des embryons présentant des défauts d’établissement au niveau de la ligne latérale postérieure. Afin de déterminer la voie pathogène impliquant l’isoforme WNK1/HSN2, nous nous sommes intéressés à l’interaction rapportée entre la kinase WNK1 et le co-transporteur neuronal KCC2. Ce dernier est une cible de phosphorylation de WNK1 et son rôle dans la promotion de la neurogenèse est bien connu. Nous avons détecté l’expression de KCC2 au niveau de neuromastes de la ligne latérale postérieure et observé une expression accrue de KCC2 chez les embryons knockdown pour WNK1/HSN2 à l’aide de RT-PCR semi-quantitative. De plus, une sur-expression d’ARN humain de KCC2 chez des embryons a produit des défauts dans la ligne latérale postérieure, phénocopiant le knockdown de WNK1/HSN2. Ces résultats furent validés par un double knockdown, produisant des embryons n’exprimant ni KCC2, ni WNK1/HSN2, dont le phénotype fut atténué. Ces résultats nous mènent à suggérer une voie de signalisation où WNK1/HSN2 est en amont de KCC2, régulant son activation, et possiblement son expression. Nous proposons donc que la perte de fonction de l’isoforme spécifique cause un débalancement dans les niveaux de KCC2 activée, menant à une prolifération et une différenciation réduites des progéniteurs neuronaux du système nerveux périphérique. Les défauts associés à la NHSA de type 2 seraient donc de nature développementale et non neurodégénérative.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
Les liposomes sont des nanovecteurs polyvalents et prometteurs quant à leur utilisation dans plusieurs domaines. Il y a une décennie, un nouveau type de liposome constitué d’amphiphiles monoalkylés et de stérols est né fortuitement dans notre groupe. Ils sont nommés Stérosomes puisqu’ils contiennent une grande proportion de stérols, entre 50 et 70 mol %. Les objectifs de cette thèse sont de développer de nouvelles formulations de Stérosomes ayant des caractéristiques spécifiques et d’acquérir une compréhension plus profonde des règles physicochimiques qui dictent leur comportement de phase. Nous avons spécifiquement examiné le rôle de motifs moléculaires des stérols, de la charge interfaciale et de la capacité à former des liaisons H dans les interactions intermoléculaires menant à l’autoassemblage. Le comportement de phase a été caractérisé par calorimétrie différentielle à balayage (DSC), par spectroscopie infrarouge (IR) et par spectroscopie de résonance magnétique nucléaire du deutérium (²H NMR). Premièrement, nous avons établi certaines corrélations entre la structure des stérols, leur tendance à former des bicouches fluides en présence d'amphiphile monoalkylé et la perméabilité des grandes vésicules unilamellaires (LUV) formées. La nature des stérols module les propriétés de mélange avec de l’acide palmitique (PA). Les stérols portant une chaîne volumineuse en position C17 sont moins aptes à induire des bicouches fluides que ceux qui ont une chaîne plus simple, comme celle du cholestérol. Un grand ordre de la chaîne alkyle de PA est un effet commun à tous les stérols investigués. Il a été démontré que la perméabilité des LUV peut être contrôlée en utilisant des stérols différents. Cependant, ces stérols n’ont aucun impact significatif sur la sensibilité des Stérosomes au pH. Afin de créer des liposomes qui sont sensibles au pH et qui ont une charge positive à la surface, des Stérosomes composés de stéarylamine et de cholestérol (Chol) ont été conçus et caractérisés. Il a été conclu que l’état de protonation de l’amine, dans ce travail, ou du groupe carboxylique, dans un travail précédent, confère une sensibilité au pH et détermine la charge à la surface du liposome. Les premiers Stérosomes complètement neutres ont été fabriqués en utilisant un réseau de fortes liaisons H intermoléculaires. Le groupe sulfoxyde est capable de former de fortes liaisons H avec le cholestérol et les molécules d’eau. Une bicouche fluide métastable a été obtenue, à la température de la pièce, à partir d'un mélange équimolaire d’octadécyl méthyl sulfoxyde (OMSO) et de Chol. Ce comportement distinct a permis d’extruder le mélange pour former des LUV à la température de la pièce. Après 30 h, le temps de vie de la phase métastable, des Stérosomes stables et imperméables existaient toujours sous une forme solide. Un diagramme de température-composition a été proposé afin de résumer le comportement de phase des mélanges d’OMSO/Chol. Finalement, nous avons élaboré des Stérosomes furtifs en incorporant du polyéthylène glycol (PEG) avec une ancre de cholestérol (PEG-Chol) à l’interface de Stérosomes de PA/Chol. Jusqu’à 20 mol % de PEG-Chol peut être introduit sans perturber la structure de la bicouche. La présence du PEG-Chol n’a aucun impact significatif sur la perméabilité de la LUV. L'encapsulation active de la doxorubicine, un médicament contre le cancer, a été réalisée malgré la faible perméabilité de ces LUV et la présence du PEG à l’interface. L’inclusion de PEG a modifié considérablement les propriétés de l’interface et a diminué la libération induite par la variation de pH observée avec des LUV nues de PA/Chol. Cette formulation inédite est potentiellement utile pour l’administration intraveineuse de médicaments.
Resumo:
In recent years,photonics has emerged as an essential technology related to such diverse fields like laser technology,fiber optics,communication,optical signal processing,computing,entertainment,consumer electronics etc.Availabilities of semiconductor lasers and low loss fibers have also revolutionized the field of sensor technology including telemetry. There exist fiber optic sensors which are sensitive,reliable.light weight and accurate devices which find applications in wide range of areas like biomedicine,aviation,surgery,pollution monitoring etc.,apart from areas in basic sciences.The present thesis deals with the design,fabrication and characterization of a variety of cost effective and sensitive fiber optic sensors for the trace detetction of certain environment pollutants in air and water.The sensor design is carried out using the techniques like evanescent waves,micro bending and long period gratings.
Resumo:
The design and development of a cost-effective, simple, sensitive and portable LED based fiber optic evanescent wave sensor for simultaneously detecting trace amounts of chromium and nitrite in water are presented. In order to obtain the desired performance, the middle portions of two multimode plastic clad silica fibers are unclad and are used as the sensing elements in the two arms of the sensor. Each of the sensor arms is sourced by separate super bright green LEDs, which are modulated in a time-sharing manner and a single photo detector is employed for detecting these light signals. The performance and characteristics of this system clearly establish the usefulness of the technique for detecting very low concentrations of the dissolved contaminants.
Resumo:
n the recent years protection of information in digital form is becoming more important. Image and video encryption has applications in various fields including Internet communications, multimedia systems, medical imaging, Tele-medicine and military communications. During storage as well as in transmission, the multimedia information is being exposed to unauthorized entities unless otherwise adequate security measures are built around the information system. There are many kinds of security threats during the transmission of vital classified information through insecure communication channels. Various encryption schemes are available today to deal with information security issues. Data encryption is widely used to protect sensitive data against the security threat in the form of “attack on confidentiality”. Secure transmission of information through insecure communication channels also requires encryption at the sending side and decryption at the receiving side. Encryption of large text message and image takes time before they can be transmitted, causing considerable delay in successive transmission of information in real-time. In order to minimize the latency, efficient encryption algorithms are needed. An encryption procedure with adequate security and high throughput is sought in multimedia encryption applications. Traditional symmetric key block ciphers like Data Encryption Standard (DES), Advanced Encryption Standard (AES) and Escrowed Encryption Standard (EES) are not efficient when the data size is large. With the availability of fast computing tools and communication networks at relatively lower costs today, these encryption standards appear to be not as fast as one would like. High throughput encryption and decryption are becoming increasingly important in the area of high-speed networking. Fast encryption algorithms are needed in these days for high-speed secure communication of multimedia data. It has been shown that public key algorithms are not a substitute for symmetric-key algorithms. Public key algorithms are slow, whereas symmetric key algorithms generally run much faster. Also, public key systems are vulnerable to chosen plaintext attack. In this research work, a fast symmetric key encryption scheme, entitled “Matrix Array Symmetric Key (MASK) encryption” based on matrix and array manipulations has been conceived and developed. Fast conversion has been achieved with the use of matrix table look-up substitution, array based transposition and circular shift operations that are performed in the algorithm. MASK encryption is a new concept in symmetric key cryptography. It employs matrix and array manipulation technique using secret information and data values. It is a block cipher operated on plain text message (or image) blocks of 128 bits using a secret key of size 128 bits producing cipher text message (or cipher image) blocks of the same size. This cipher has two advantages over traditional ciphers. First, the encryption and decryption procedures are much simpler, and consequently, much faster. Second, the key avalanche effect produced in the ciphertext output is better than that of AES.
Resumo:
One of the main challenges in the development of metal-oxide gas sensors is enhancement of selectivity to a particular gas. Currently, two general approaches exist for enhancing the selective properties of sensors. The first one is aimed at preparing a material that is specifically sensitive to one compound and has low or zero cross-sensitivity to other compounds that may be present in the working atmosphere. To do this, the optimal temperature, doping elements, and their concentrations are investigated. Nonetheless, it is usually very difficult to achieve an absolutely selective metal oxide gas sensor in practice. Another approach is based on the preparation of materials for discrimination between several analyte in a mixture. It is impossible to do this by using one sensor signal. Therefore, it is usually done either by modulation of sensor temperature or by using sensor arrays. The present work focus on the characterization of n-type semiconducting metal oxides like Tungsten oxide (WO3), Zinc Oxide (ZnO) and Indium oxide (In2O3) for the gas sensing purpose. For the purpose of gas sensing thick as well as thin films were fabricated. Two different gases, NO2 and H2S gases were selected in order to study the gas sensing behaviour of these metal oxides. To study the problem associated with selectivity the metal oxides were doped with metals and the gas sensing characteristics were investigated. The present thesis is entitled “Development of semiconductor metal oxide gas sensors for the detection of NO2 and H2S gases” and consists of six chapters.
Resumo:
Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.
Resumo:
Investigaciones recientes sugieren que en la adolescencia tienen lugar importantes cambios en la estructura, bioquímica y fisiología del cerebro que podrían explicar la dificultad que experimentan los adolescentes en el control de sus emociones así como también otros rasgos de su comportamiento inestable. En este artículo presentamos algunas investigaciones que establecen, asimismo, una correlación entre las reorganizaciones cerebrales que tienen lugar en el primer año de vida con signos de irritabilidad y desazón emocional que muestra el bebé durante este periodo. En ambos casos la dificultad de controlar los impulsos emocionales es susceptible de afectar la relación de los padres con el niño o joven. Discutimos la posible relevancia de esta coincidencia dentro de una perspectiva evolucionista así como la posible vulnerabilidad de estos períodos. Finalmente, apuntamos la necesidad de una teoría integradora del desarrollo humano y ofrecemos algunos puntos de debate
Resumo:
Many connections in the basal ganglia are made around birth when animals are exposed to a host of new affective, cognitive, and sensori-motor stimuli. It is thought that dopamine modulates cortico-striatal synapses that result in the strengthening of those connections that lead to desired outcomes. We propose that there must be a time before which stimuli cannot be processed into functional connections, otherwise it would imply an effective link between stimulus, response, and reward in uterus. Consistent with these ideas, we present evidence that early in development dopamine neurons are electrically immature and do not produce high-frequency firing in response to salient stimuli. We ask first, what makes dopamine neurons immature? and second, what are the implications of this immaturity for the basal ganglia? As an answer to the first question, we find that at birth the outward current is small (3nS-V), insensitive to Ca2z, TEA, BK, and SK blockers. Rapidly after birth, the outward current increases to 15nS-V and becomes sensitive to Ca2z, TEA, BK, and SK blockers. We make a detailed analysis of the kinetics of the components of the outward currents and produce a model for BK and SK channels that we use to reproduce the outward current, and to infer the geometrical arrangement of BK and Ca2z channels in clusters. In the first cluster, T-type Ca2z and BK channels are coupled within distances of *20 nm (200 A˚). The second cluster consists of L-type Ca2z and BK channels that are spread over distances of at least 60 nm. As for the second question, we propose that early in development, the mechanism of action selection is in a ‘‘locked-in’’ state that would prevent dopamine neurons from reinforcing cortico-striatal synapses that do not have a functional experiential- based value.
Resumo:
Many connections in the basal ganglia are made around birth when animals are exposed to a host of new affective, cognitive, and sensori-motor stimuli. It is thought that dopamine modulates cortico-striatal synapses that result in the strengthening of those connections that lead to desired outcomes. We propose that there must be a time before which stimuli cannot be processed into functional connections, otherwise it would imply an effective link between stimulus, response, and reward in uterus. Consistent with these ideas, we present evidence that early in development dopamine neurons are electrically immature and do not produce high-frequency firing in response to salient stimuli. We ask first, what makes dopamine neurons immature? and second, what are the implications of this immaturity for the basal ganglia? As an answer to the first question, we find that at birth the outward current is small (3nS-V), insensitive to Ca2+, TEA, BK, and SK blockers. Rapidly after birth, the outward current increases to 15nS-V and becomes sensitive to Ca2+, TEA, BK, and SK blockers. We make a detailed analysis of the kinetics of the components of the outward currents and produce a model for BK and SK channels that we use to reproduce the outward current, and to infer the geometrical arrangement of BK and Ca2+ channels in clusters. In the first cluster, T-type Ca2+ and BK channels are coupled within distances of similar to 20 nm (200 parallel to). The second cluster consists of L-type Ca2+ and BK channels that are spread over distances of at least 60 nm. As for the second question, we propose that early in development, the mechanism of action selection is in a "locked-in" state that would prevent dopamine neurons from reinforcing cortico-striatal synapses that do not have a functional experiential-based value.