993 resultados para SYMPTOM-FREE SUBJECTS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The blood pressure, heart rate and humoral responses to single intravenous doses of the angiotensin converting enzyme inhibitor captopril were evaluated in 5 volunteers on a free salt intake. Each subject was given at one-week intervals a 1, 5 and 25 mg intravenous dose of captopril as well as the vehicle of captopril. The study was conducted in a single-blind fashion and the order of treatment phases was randomized. Captopril was found to inhibit the renin-angiotensin system in a dose-dependent fashion. A fall in circulating angiotensin II was observed with doses of 1 and 5 mg. Plasma angiotensin II was not detectable 15 min after the 25 mg dose. Acute inhibition of angiotensin converting enzyme with intravenous captopril had no effect on blood pressure and heart rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to investigate the relationship between the physical activity (PA) and its related variables under confinement and in free-living conditions in Asian individuals, where no such information presently exists. The subjects consisted of eighty-six Japanese individuals with a mean age of 38+/-12 years. Under confinement in a large respiratory chamber, the energy expenditure (EE) was measured for 24h. In addition, two moderate walking exercises of 30 min each on a horizontal treadmill were assigned. Free-living measurements of 7 days were also performed using a validated accelerometer. The PA level in the chamber (1.47+/-0.11), expressed as a multiple of the basal EE, was lower than that in free-living conditions (1.53+/-0.12) (p<0.001). However, the two values were closely correlated (r=0.744, p<0.001). Conversely, a residual analysis showed a wide variation in the mean difference for both conditions and revealed a significant systematic error (r=-0.548, p<0.001), thus indicating an increased gap with increasing PA levels in free-living conditions. Similar results were obtained following the exclusion of the imposed exercise sessions. In contrast, the daily step counts under both conditions did not show any correlation. The PA level in the chamber (including and excluding imposed walking exercises) is compatible with the PA level in free-living conditions at the group level, although the daily step counts are unrelated. Thus, the PA level in the chamber may provide valuable information to help us achieve a better understanding of human PA in daily life as it is related to behavioral research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The nutritional status of cystic fibrosis (CF) patients has to be regularly evaluated and alimentary support instituted when indicated. Bio-electrical impedance analysis (BIA) is a recent method for determining body composition. The present study evaluates its use in CF patients without any clinical sign of malnutrition. Thirty-nine patients with CF and 39 healthy subjects aged 6-24 years were studied. Body density and mid-arm muscle circumference were determined by anthropometry and skinfold measurements. Fat-free mass was calculated taking into account the body density. Muscle mass was obtained from the urinary creatinine excretion rate. The resistance index was calculated by dividing the square of the subject's height by the body impedance. We show that fat-free mass, mid-arm muscle circumference and muscle mass are each linearly correlated to the resistance index and that the regression equations are similar for both CF patients and healthy subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a previous study, we demonstrated that the new beta-adrenoceptor agonist Ro 16-8714 possesses thermogenic property in normal male volunteers. The aim of the present study was to compare the metabolic response of lean vs obese individuals to a similar dose of this compound. Following an overnight fast, Ro 16-8714 (0.17 mg/kg fat free mass) or a placebo was given per os to six normal-weight subjects and to six moderately obese subjects. The rate of energy expenditure (EE) and the substrate utilization were determined by indirect calorimetry (hood system) before and for 6 h following the drug administration. Heart rate and blood pressure as well as plasma glucose, insulin and free fatty acid (FFA) concentrations were also measured at regular intervals throughout the study. The increment relative to base-line (mean +/- s.e.m.) in EE was similar in the two groups and averaged 4.0 +/- 1.4 per cent and 12.2 +/- 1.4 per cent with placebo and with Ro 16-8714 respectively in lean subjects, whereas the values reached 3.5 +/- 1.2 per cent and 14.4 +/- 2.0 per cent in obese subjects. Heart rate, systolic blood pressure, insulin and FFA were increased without any significant difference between the two groups. This study shows that Ro 16-8714 is a potent thermogenic agent both in normal and obese subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the prevalence of low fat-free mass index (FFMI) and high and very high body fat mass index (BFMI) after lung transplantation (LTR). A total of 37 LTR patients were assessed prior to and at 1 month, 1 year and 2 years for FFM and compared to 37 matched volunteers (VOL). FFM was calculated by the Geneva equation and normalized for height (kg/m(2)). Subjects were classified as FFMI "low", <or=17.4 in men and <or=15.0 in women; BFMI "high", 5.2-8.1 in men and 8.3-11.7 in women; or "very high" >8.2 kg/m(2) in men and >11.8 kg/m(2) in women. In 23 M/14 F, body mass index (BMI) was 22.3+/-4.4 and 20.1+/-4.9 kg/m(2), respectively. The prevalence of low FFMI was 80% at 1 month and 33% at 2 years after LTR. Prevalence of very high BFMI increased and was higher in patients than VOL after LTR. The prevalence of low FFMI was high prior to and remained important 2 years after LTR, whereas BFMI was lower prior to and higher 2 years after LTR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P &lt; 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P &lt; 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P &lt; 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Black women are at greater risk of obesity than are white women, perhaps because of their lower levels of physical activity. OBJECTIVE: We compared free-living activity energy expenditure (AEE) in sedentary white and black women (in overweight and normal-weight states) and in never-overweight control subjects. DESIGN: Subjects included 46 women (23 white, 23 black) studied while overweight and after reaching a normal weight and 38 female control subjects (23 white, 15 black). Diet, without exercise training, resulted in a mean weight loss of 13 kg and a body mass index (in kg/m(2)) < 25. Body composition, sleeping energy expenditure, free-living total energy expenditure, and the energy cost of activity and aerobic capacity were assessed before and after weight loss under 4-wk, diet-controlled, weight-stable conditions and in the control subjects. AEE was defined as above-sleep energy expenditure. RESULTS: No significant racial differences in body composition, before or after weight loss, were found. After weight loss, AEE and aerobic capacity increased in the white women and decreased in the black women (P < 0.05 and P < 0.02, respectively). After weight loss, but not before, the white women had a significantly higher mean AEE than did the black women (2448 +/- 979 and 1728 +/- 1373 kJ/d, respectively; P < 0.05), approximating AEEs in the white (2314 +/- 1105) and black (2310 +/- 1251) control subjects. CONCLUSIONS: Relative to the responses of the white women to diet-induced weight loss, the black women became less fit and less physically active. Induction of a normal body weight in overweight black women appeared to produce a more obesity-prone state, favoring weight relapse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare the metabolic effects of fructose in healthy male and female subjects. RESEARCH DESIGN AND METHODS: Fasting metabolic profile and hepatic insulin sensitivity were assessed by means of a hyperglycemic clamp in 16 healthy young male and female subjects after a 6-day fructose overfeeding. RESULTS: Fructose overfeeding increased fasting triglyceride concentrations by 71 vs. 16% in male vs. female subjects, respectively (P &lt; 0.05). Endogenous glucose production was increased by 12%, alanine aminotransferase concentration was increased by 38%, and fasting insulin concentrations were increased by 14% after fructose overfeeding in male subjects (all P &lt; 0.05) but were not significantly altered in female subjects. Fasting plasma free fatty acids and lipid oxidation were inhibited by fructose in male but not in female subjects. CONCLUSIONS: Short-term fructose overfeeding produces hypertriglyceridemia and hepatic insulin resistance in men, but these effects are markedly blunted in healthy young women.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The early diagnostic value of glucose hypometabolism and atrophy as potential neuroimaging biomarkers of mild cognitive impairment (MCI) and Alzheimer's disease (AD) have been extensively explored using [18F]fluorodeoxyglucose positron emission tomography (FDG-PET) and structural magnetic resonance imaging (MRI). The vast majority of previous imaging studies neglected the effects of single factors, such as age, symptom severity or time to conversion in MCI thus limiting generalisability of results across studies. Here, we investigated the impact of these factors on metabolic and structural differences. FDG-PET and MRI data from AD patients (n = 80), MCI converters (n = 65) and MCI non-converters (n = 64) were compared to data of healthy subjects (n = 79). All patient groups were split into subgroups by age, time to conversion (for MCI), or symptom severity and compared to the control group. AD patients showed a strongly age-dependent pattern, with younger patients showing significantly more extensive reductions in gray matter volume and glucose utilisation. In the MCI converter group, the amount of glucose utilisation reduction was linked to the time to conversion but not to atrophy. Our findings indicate that FDG-PET might be more closely linked to future cognitive decline whilst MRI being more closely related to the current cognitive state reflects potentially irreversible damage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to investigate the impact of radial k-space sampling and steady-state free precession (SSFP) imaging on image quality in MRI of coronary vessel walls. SUBJECTS AND METHODS: Eleven subjects were examined on a 1.5-T MR system using three high-resolution navigator-gated and cardiac-triggered 3D black blood sequences (cartesian gradient-echo [GRE], radial GRE, and radial SSFP) with identical spatial resolution (0.9 x 0.9 x 2.4 mm3). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and motion artifacts were analyzed. RESULTS: The mean SNR and CNR of the coronary vessel wall were improved using radial imaging and were best using radial k-space sampling combined with SSFP imaging. Vessel border definition was similar for all three sequences. Radial k-space sampling was found to be less sensitive to motion. Consistently good image quality was seen with the radial GRE sequence. CONCLUSION: Radial k-space sampling in MRI of coronary vessel walls resulted in fewer motion artifacts and improved SNR and CNR. The use of SSFP imaging, however, did not result in improved coronary vessel wall visualization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty-four-hour energy expenditure (24-EE), resting metabolic rate (RMR) and body composition were determined in 30 subjects from three groups; control (103 +/- 2% ideal body weight, n = 10), moderately obese (129 +/- 1% ideal body weight, n = 6), and obese (170 +/- 5% ideal body weight, n = 14) individuals. Twenty-four EE was measured in a comfortable airtight respiration chamber. When expressed as absolute values, both RMR and 24-EE were significantly increased in obese subjects when compared to normal weight subjects. The RMR was 7592 +/- 351 kJ/day in the obese, 6652 +/- 242 kJ/day in the moderately obese, and 6118 +/- 405 kJ/day in the controls. Mean 24-EE values were 10043 +/- 363, 9599 +/- 277, and 8439 +/- 432 kJ/day in the obese, moderately obese, and controls, respectively. The larger energy expenditure in the obese over 24 h was mainly due to a greater VO2 during the daylight hours. However, 92% of the larger 24-EE in the obese, compared to the control group, was accounted for by the higher RMR and only 8% by other factors such as the increased cost of moving the extra weight of the obese. The higher RMR and 24-EE in the obese was best related to the increased fat free mass.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.