915 resultados para SURGICAL-CORRECTION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To investigate the effect of metal implants in proton radiotherapy, dose distributions of different, clinically relevant treatment plans have been measured in an anthropomorphic phantom and compared to treatment planning predictions. The anthropomorphic phantom, which is sliced into four segments in the cranio-caudal direction, is composed of tissue equivalent materials and contains a titanium implant in a vertebral body in the cervical region. GafChromic® films were laid between the different segments to measure the 2D delivered dose. Three different four-field plans have then been applied: a Single-Field-Uniform-Dose (SFUD) plan, both with and without artifact correction implemented, and an Intensity-Modulated-Proton-Therapy (IMPT) plan with the artifacts corrected. For corrections, the artifacts were manually outlined and the Hounsfield Units manually set to an average value for soft tissue. Results show a surprisingly good agreement between prescribed and delivered dose distributions when artifacts have been corrected, with > 97% and 98% of points fulfilling the gamma criterion of 3%/3 mm for both SFUD and the IMPT plans, respectively. In contrast, without artifact corrections, up to 18% of measured points fail the gamma criterion of 3%/3 mm for the SFUD plan. These measurements indicate that correcting manually for the reconstruction artifacts resulting from metal implants substantially improves the accuracy of the calculated dose distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Correction of all kind of deformities at the distal part of the femur (supracondylar). INDICATIONS Flexion, extension osteotomies, and varus or valgus, and external or internal rotation osteotomies, and shortening osteotomies of the distal femur or combined surgical procedures (e.g., extension and de-rotation osteotomy). CONTRAINDICATIONS Osteotomy through unknown bony process. SURGICAL TECHNIQUE LCP system provides angular stable fixation. POSTOPERATIVE MANAGEMENT Without concomitant surgical procedures of soft tissue (e.g., patellar tendon shortening), early functional rehabilitation is possible with immediate weight bearing (35 kg for small fragment plates and 70 kg for large fragment plates). RESULTS The surgical procedure is safe and is associated with few complications. Overall complication rate in this series of patients was 3%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acetabular retroversion is the result of an externally rotated hemipelvis rather than a focal overgrowth of the anterior wall and/or hypoplasia of the posterior wall. Acetabular retroversion is a cause of pincer impingement which, if left untreated, can lead to hip pain and osteoarthritis. The causal surgical treatment in hips with acetabular retroversion is acetabular reorientation with a reverse periacetabular osteotomy (PAO). Indication is based on a positive correlation among symptoms (typically groin pain), physical findings on examination (positive anterior impingement test and decreased flexion and internal rotation), and radiographic signs for acetabular retroversion. These include a positive crossover, posterior wall, and ischial spine sign. A reverse PAO is performed with four osteotomies and a controlled fracture. Unlike reorientation of the acetabular fragment in dysplastic hips, correction for acetabular retroversion is achieved by a combined extension and internal rotation of the acetabular fragment. Typically, a small supra-acetabular wedge resection is required to allow sufficient extension of the fragment. The quality of acetabular reorientation is evaluated by intraoperative AP pelvic radiographs. In addition, intraoperative testing of range of motion following acetabular reorientation is mandatory. An arthrotomy and offset correction of the femoral head-neck area is indicated in hips with decreased internal rotation following acetabular reorientation. In a 10-year follow-up study of reverse PAO, a favorable outcome with preservation of all native joints was found. Correct acetabular orientation and, if necessary, a concomitant offset correction were the keys of successful outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospital acquired infections (HAI) are costly but many are avoidable. Evaluating prevention programmes requires data on their costs and benefits. Estimating the actual costs of HAI (a measure of the cost savings due to prevention) is difficult as HAI changes cost by extending patient length of stay, yet, length of stay is a major risk factor for HAI. This endogeneity bias can confound attempts to measure accurately the cost of HAI. We propose a two-stage instrumental variables estimation strategy that explicitly controls for the endogeneity between risk of HAI and length of stay. We find that a 10% reduction in ex ante risk of HAI results in an expected savings of £693 ($US 984).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prospective, consecutive series of 106 patients receiving endoscopic anterior scoliosis correction. The aim was to analyse changes in radiographic parameters and rib hump in the two years following surgery. Endoscopic anterior scoliosis correction is a level sparing approach, therefore it is important to assess the amount of decompensation which occurs after surgery. All patients received a single anterior rod and vertebral body screws using a standard compression technique. Cleared disc spaces were packed with either mulched femoral head allograft or rib head/iliac crest autograft. Radiographic parameters (major, instrumented, minor Cobb, T5-T12 kyphosis) and rib hump were measured at 2,6,12 and 24 months after surgery. Paired t-tests and Wilcoxon signed ranks tests were used to assess the statistical significant of changes between adjacent time intervals.----- Results: Mean loss of major curve correction from 2 to 24 months after surgery was 4 degrees. Mean loss of rib hump correction was 1.4 degrees. Mean sagittal kyphosis increased from 27 degrees at 2 months to 30.6 degrees at 24 months. Rod fractures and screw-related complications resulted in several degrees less correction than patients without complications, but overall there was no clinically significant decompensation following complications. The study concluded that there are small changes in deformity measures after endoscopic anterior scoliosis surgery, which are statistically significant but not clinically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary aims of scoliosis surgery are to halt the progression of the deformity, and to reduce its severity (cosmesis). Currently, deformity correction is measured in terms of posterior parameters (Cobb angles and rib hump), even though the cosmetic concern for most patients is anterior chest wall deformity. In this study, we propose a new measure for assessing anterior chest wall deformity and examine the correlation between rib hump and the new measure. 22 sets of CT scans were retrieved from the QUT/Mater Paediatric Spinal Research Database. The Image J software (NIH) was used to manipulate formatted CT scans into 3-dimensional anterior chest wall reconstructions. A ‘chest wall angle’ was then measured in relation to the first sacral vertebral body. The chest wall angle was found to be a reliable tool in the analysis of chest wall deformity. No correlation was found between the new measure and rib hump angle. Since rib hump has been shown to correlate with vertebral rotation on CT, this suggests that there maybe no correlation between anterior and posterior deformity measures. While most surgical procedures will adequately address the coronal imbalance & posterior rib hump elements of scoliosis, they do not reliably alter the anterior chest wall shape. This implies that anterior chest wall deformity is to a large degree an intrinsic deformity, not directly related to vertebral rotation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Anterior vertebral stapling using a nitinol staple is one such treatment. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The aims of this study were threefold; (1) to measure changes in the bending stiffness of a single motion segment following staple insertion, (2) to describe the forces that occur within the staple during spinal movement, and (3) to describe the anatomical changes that occur following staple insertion. Results suggest that staple insertion consistently decreased stiffness in all directions of motion. An explanation for the finding may be found in the outcomes of the strain gauge testing and micro-CT scan. The strain gauge testing showed that once inserted, the staple tips applied a baseline compressive force to the surrounding trabecular bone and vertebral end-plate. This finding would be consistent with the current belief that the clinical effect of the staples is via unilateral compression of the physis. Interestingly however, as each specimen progressed through the five cycles of each test, the baseline load on the staple tips gradually decreased, implying that the force at the staple tip-bone interface was decreasing. We believe that this was likely occurring as a result of structural damage to the trabecular bone and vertebral end-plate by the staple effectively causing ‘loosening’ of the staple. This hypothesis is further supported by the findings of the micro-CT scan. The pictures depict significant trabecular bone and physeal injury around the staple blades. These results suggest that the current hypothesis that stapling modulates growth through physeal compression may be incorrect, but rather the effect occurs through mechanical disruption of the vertebral growth plate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone graft is generally considered fundamental in achieving solid fusion in scoliosis correction and pseudarthrosis following instrumentation may predispose to implant failure. In endoscopic anterior-instrumented scoliosis surgery, autologous rib or iliac crest graft has been utilised traditionally but both techniques increase operative duration and cause donor site morbidity. Allograft bone and bone- morphogenetic-protein alternatives may improve fusion rates but this remains controversial. This study's objective was to compare two-year postoperative fusion rates in a series of patients who underwent endoscopic anterior instrumentation for thoracic scoliosis utilising various bone graft types. Significantly better rates of fusion occurred in endoscopic anterior instrumented scoliosis correction using femoral allograft compared to autologous rib-heads and iliac crest graft. This may be partly explained by the difficulty obtaining sufficient quantities of autologous graft. Lower fusion rates in the autologous graft group appeared to predispose to rod fracture although the clinical consequence of implant failure is uncertain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.