980 resultados para SPECT-CT
Resumo:
FUNDAMENTO: Alguns pacientes apresentam fração de ejeção do ventrículo esquerdo (FEVE) superestimada na cintilografia miocárdica com sincronização eletrocardiográfica (gated SPECT). OBJETIVO: Estabelecer a relação entre fatores biológicos e FEVE superestimada. MÉTODOS: Selecionamos 3.838 pacientes que realizaram gated SPECT entre 20/5/2000 e 16/9/2005, com imagens normais de perfusão e FEVE >50%. Analisamos as variáveis: sexo (29,4% feminino e 70,6% masculino), idade (de 20 a 94 anos - média: 56 anos), peso (de 33,5 a 150 kg - média: 79,6 kg), altura (de 138 a 220 cm - média: 171 cm) e IMC (de 13,9 a 54 - média: 27,2). Em um subgrupo de 1.002 pacientes que realizaram ecocardiograma, incluímos as variáveis diâmetros diastólico (de 36 a 68 mm - média 47,5 mm) e sistólico (de 22 a 41 mm - média 29,8 mm). Dividimos os pacientes em dois grupos: FEVE normal (<80%) e superestimada (>80%). A Razão de Chances (RC) para apresentar FEVE superestimada foi calculada para cada variável por regressão logística. RESULTADOS: Encontramos as seguintes Razões de Chances (p < 0,005): sexo feminino RC = 3,585 (IC95%: 2,745 a 4,683), idade em anos RC = 1,020 (IC95%: 1,011 a 1,029) e altura em cm RC = 0,893 (IC95%: 0,829 a 0,962). O peso e o IMC não se associaram a FEVE significativamente (p>0,2). No subgrupo de 1.002 pacientes, encontramos influência estatisticamente significativa na obtenção da FEVE superestimada para as variáveis diâmetro sistólico, sexo e altura. CONCLUSÃO: Apesar de o diâmetro sistólico influenciar na obtenção da FEVE superestimada, as variáveis sexo e altura apresentam influência independente na superestimação da FEVE pelo gated SPECT.
Resumo:
FUNDAMENTO: A avaliação da função ventricular esquerda pode ser limitada pela movimentação anômala do septo interventricular, freqüentemente encontrada após cirurgia de revascularização miocárdica (CRM). A validação do Gated SPECT como ferramenta para avaliação da função ventricular nesse grupo de pacientes é escassa. OBJETIVO: Investigamos a concordância e a correlação entre a fração de ejeção do ventrículo esquerdo (FEVE), o volume diastólico final (VDF) e o volume sistólico final (VDF), obtidos pela cintilografia de perfusão miocárdica tomográfica sincronizada pelo eletrocardiograma (Gated SPECT), com os mesmos parâmetros medidos pela ressonância magnética cardíaca em 20 pacientes submetidos à revascularização miocárdica. MÉTODOS: A correlação foi medida pelo coeficiente de correlação de Spearman (ρ), enquanto a concordância foi avaliada por meio da análise de Bland e Altman. RESULTADOS: Houve uma correlação boa entre o Gated SPECT e a ressonância magnética cardíaca nos pacientes após CRM em relação à fração de ejeção do ventrículo esquerdo (ρ = 0,85; p = 0,0001), uma correlação moderada para o volume sistólico final (ρ = 0,51; p = 0,02) e uma correlação insignificante para o volume diastólico final (ρ = 0,13; p = 0,5). Os limites de concordância para FEVE, VSF e VDF foram: de -20% a 12%; de -38 a 54ml e de -96 a 100ml, respectivamente. CONCLUSÃO: A fração de ejeção do ventrículo esquerdo obtida pelo Gated SPECT correlaciona-se de modo confiável com a da ressonância magnética em pacientes submetidos à CRM. Os volumes ventriculares, entretanto, não apresentam uma correlação adequada.
Resumo:
FUNDAMENTO: O choque cardiogênico e o edema agudo de pulmão são as principais causas de óbito em pacientes com escorpionismo, cujo mecanismo fisiopatológico ainda é controverso. OBJETIVOS: Investigar a correlação entre os distúrbios da perfusão miocárdica e a função contrátil do ventrículo esquerdo, em vítimas de escorpionismo. MÉTODOS: Quinze pacientes submeteram-se à cintilografia de perfusão miocárdica sincronizada com ECG (Gated SPECT), dentro de 72 horas e 15 dias após o acidente escorpiônico. As imagens foram analisadas visualmente por escore semiquantitativo de perfusão (0 = normal, 4 = ausente) e mobilidade (0 = normal, 4 = acinético), utilizando modelo de 17 segmentos. Para cada paciente foram calculados escores somados de perfusão (ESP) e mobilidade (ESM). A fração de ejeção (FEVE) foi calculada por software comercialmente disponível. RESULTADOS: Na avaliação inicial, 12 dos 15 pacientes apresentaram alterações da contratilidade e da perfusão miocárdica. O ESP foi de 12,5 ± 7,3, o ESM de 17,0 ± 12, 8 e a FEVE de 44,6 ± 16,0%. Houve correlação positiva entre o ESP e o ESM (r = 0,68; p = 0,005) e negativa entre o ESP e a FEVE (r = -0,75; p = 0,0021). Os estudos de seguimento mostraram recuperação da contratilidade global (FEVE de 68,9 ± 9,5, p = 0,0002), segmentar (ESM 2,6 ± 3,1, p = 0,0009) e da perfusão (ESP 3,7 ± 3,3, p = 0,0003). A melhora da FEVE correlacionou-se positivamente com a melhora do ESP (r = 0,72; p = 0,0035). CONCLUSÕES: Alterações perfusionais miocárdicas são comuns no envenenamento escorpiônico e correlacionam-se topograficamente com a disfunção contrátil. A recuperação da contratilidade correlaciona-se com a reversibilidade dos defeitos perfusionais. Estes achados sugerem a participação de alterações perfusionais miocárdicas na fisiopatologia desta forma de insuficiência ventricular aguda. (Arq Bras Cardiol 2010;94(4): 444-451)
Resumo:
FUNDAMENTO: Técnicas de imageamento in vivo permitem avaliar sequencialmente a morfologia e a função dos órgãos em diversos modelos experimentais. Desenvolvemos um dispositivo de adaptação de uma gama-câmara clínica para obter imagens tomográficas por emissão de fótons singulares (SPECT) de alta resolução, baseado em colimador pinhole. OBJETIVO: Determinar a acurácia desse sistema na quantificação da área de infarto miocárdico em ratos. MÉTODOS: Treze ratos Wistar machos (250 g) foram submetidos a infarto do miocárdio por oclusão da artéria coronária esquerda. Após 4 semanas, foram adquiridas imagens tomográficas com o sistema desenvolvido, 1,5 hora após a injeção endovenosa de 555MBq de 99mTc-Sestamibi. Na reconstrução tomográfica, utilizamos software especialmente desenvolvido baseado no algoritmo de Máxima Verossimilhança. Comparamos as médias e analisamos a correlação entre a extensão dos defeitos perfusionais detectados pela cintilografia e a extensão da fibrose miocárdica avaliada pela histologia. RESULTADOS: As imagens apresentaram ótima relação órgão-alvo/fundo, com apropriada visualização das paredes e da cavidade do ventrículo esquerdo. Todos os animais exibindo áreas de infarto foram corretamente identificados pelas imagens de perfusão. Não houve diferença entre a área do infarto medida pelo SPECT (21,1 ± 21,2%) e pela histologia (21,7 ± 22,0%; p = 0,45), obtendo forte correlação entre os valores da área de infarto mensurada pelos dois métodos (r = 0,99; p < 0,0001). CONCLUSÃO: O sistema desenvolvido apresentou resolução espacial adequada e elevada acurácia para detecção e quantificação das áreas de infarto miocárdico, sendo uma opção de baixo custo e grande versatilidade na obtenção de imagens em SPECT de alta resolução de órgãos de pequenos roedores.
Resumo:
AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.
Resumo:
AbstractIntroduction:Coronary computed tomography angiography (CCTA) allows for non-invasive coronary artery disease (CAD) phenotyping. There are still some uncertainties regarding the impact this knowledge has on the clinical care of patients.Objective:To determine whether CAD phenotyping by CCTA influences clinical decision making by the prescription of cardiovascular drugs and their impact on non-LDL cholesterol (NLDLC) levels.Methods:We analysed consecutive patients from 2008 to 2011 submitted to CCTA without previous diagnosis of CAD that had two serial measures of NLDLC, one up to 3 months before CCTA and the second from 3 to 6 months after.Results:A total of 97 patients were included, of which 69% were men, mean age 64 ± 12 years. CCTA revealed that 18 (18%) patients had no CAD, 38 (39%) had non-obstructive (< 50%) lesions and 41 (42%) had at least one obstructive ≥ 50% lesion. NLDLC was similar at baseline between the grups (138 ± 52 mg/dL vs. 135 ± 42 mg/dL vs. 131 ± 44 mg/dL, respectively, p = 0.32). We found significative reduction in NLDLC among patients with obstrctive lesions (-18%, p = 0.001). We also found a positive relationship between clinical treatment intensification with aspirin and cholesterol reducing drugs and the severity of CAD.Conclusion:Our data suggest that CCTA results were used for cardiovascular clinical treatment titration, with especial intensification seen in patients with obstructive ≥50% CAD.
Resumo:
Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.
Resumo:
Magdeburg, Univ., Med. Fak., Diss., 2011
Resumo:
Die Mesostruktur von Werkstoffen wie Faserverbundwerkstoffen und Schaumstoffen beeinflusst deren mechanisches Verhalten wesentlich. Die inneren Strukturen des Werkstoffes müssen in die Analyse des Verformungs- und Versagensverhaltens einbezogen werden. Die Röntgenanalyse, insbesondere die Röntgen-Computertomographie (Röntgen-CT) ermöglicht eine zerstörungsfreie 3-dimensionale (3-d) Visualisierungund Charakterisierung innerer Strukturen. Für die Untersuchung des Einflusses der Mesostruktur eines Polymethacrymlid-Hartschaumstoffes auf das mechanische Verhalten speziell unter zugbelastung sollte eine speziell vom Fraunhofer-Institut für Werkstoffmechanik in Halle entwickelte In-situ-Verformungseinrichtung erprobt werden. Die Anlage wurde speziell für den Zugversuch optimiert. Es folgten mechanische Experimente, die mit den 3d-Bilddaten der Zellstruktur des Schaumstoffes korrelieren. Die ermittelten Bilddaten werden mit Hilfe einer Bildanalysesoftware ausgewertet und Rückschlüsse auf Verformungs- und Versagensverhalten grtroffen.
Resumo:
Universität Magdeburg, Univ., Dissertation, 2016
Resumo:
A 67-year-old woman was referred for staging of a mucosa-associated lymphoid tumor lymphoma involving the left conjunctiva. CT scan had shown paravertebral and pelvic masses, and a breast nodule. FDG PET/CT demonstrated moderately increased uptake in the left ocular conjunctiva and confirmed the paravertebral and pelvic masses and the breast nodule. Moreover, abnormal FDG uptake was shown in 2 breast nodules, the flank, the gluteus maximus, and the gastric cardia. The patient received 6 cycles of rituximab-bendamustine chemotherapy with a complete clinical and metabolic response at the 6-month follow-up PET/CT and remained relapse-free without visual acuity problem after a 36-month follow-up.
Resumo:
The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.