843 resultados para Residual-Based Cointegration Test
Resumo:
Background. In malaria-endemic areas it is recommended that febrile children be tested for malaria by rapid diagnostic test (RDT) or blood slide (BS) and receive effective malaria treatment only if results are positive. However, RDTs are known to perform less well for Plasmodium vivax. We evaluated the safety of withholding antimalarial drugs from young Papua New Guinean children with negative RDT results in areas with high levels of both Plasmodium falciparum and P. vivax infections. Methods. longitudinal prospective study of children aged 3-27 months visiting outpatient clinics for fever. RDT was administered at first visit. RDT and microscopy were performed if children returned because of persistent symptoms. Outcomes were rates of reattendance and occurrence of severe illnesses. Results. Of 5670 febrile episodes, 3942 (70%) involved a negative RDT result. In 133 cases (3.4%), the children reattended the clinic within 7 days for fever, of whom 29 (0.7%) were parasitemic by RDT or microscopy. Of children who reattended, 24 (0.7%) presented with a severe illness: 2 had lower respiratory tract infections (LRTIs) with low-density P. vivax on BS; 2 received a diagnosis of P. vivax malaria on the basis of RDT but BSs were negative; 16 had LRTIs; 3 had alternative diagnoses. Of these 24, 22 were cured at day 28. Two children died of illnesses other than malaria and were RDT and BS negative at the initial and subsequent visits. Conclusion. Treatment for malaria based on RDT results is safe and feasible even in infants living in areas with moderate to high endemicity for both P. falciparum and P. vivax infections.
Resumo:
Toxicity of chemical pollutants in aquatic environments is often addressed by assays that inquire reproductive inhibition of test microorganisms, such as algae or bacteria. Those tests, however, assess growth of populations as a whole via macroscopic methods such as culture turbidity or colony-forming units. Here we use flow cytometry to interrogate the fate of individual cells in low-density populations of the bacterium Pseudomonas fluorescens SV3 exposed or not under oligotrophic conditions to a number of common pollutants, some of which derive from oil contamination. Cells were stained at regular time intervals during the exposure assay with fluorescent dyes that detect membrane injury (i.e., live-dead assay). Reduction of population growth rates was observed upon toxicant insult and depended on the type of toxicant. Modeling and cell staining indicate that population growth rate decrease is a combined effect of an increased number of injured cells that may or may not multiply, and live cells dividing at normal growth rates. The oligotrophic assay concept presented here could be a useful complement for existing biomarker assays in compliance with new regulations on chemical effect studies or, more specifically, for judging recovery after exposure to fluctuating toxicant conditions.
Resumo:
A test kit based on living, lyophilized bacterial bioreporters emitting bioluminescence as a response to arsenite and arsenate was applied during a field campaign in six villages across Bangladesh. Bioreporter field measurements of arsenic in groundwater from tube wells were in satisfying agreement with the results of spectroscopic analyses of the same samples conducted in the lab. The practicability of the bioreporter test in terms of logistics and material requirements, suitability for high sample throughput, and waste disposal was much better than that of two commercial chemical test kits that were included as references. The campaigns furthermore demonstrated large local heterogeneity of arsenic in groundwater, underscoring the use of well switching as an effective remedy to avoid high arsenic exposure.
Resumo:
Aims and objectives This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.
Resumo:
Several unit root tests in panel data have recently been proposed. The test developed by Harris and Tzavalis (1999 JoE) performs particularly well when the time dimension is moderate in relation to the cross-section dimension. However, in common with the traditional tests designed for the unidimensional case, it was found to perform poorly when there is a structural break in the time series under the alternative. Here we derive the asymptotic distribution of the test allowing for a shift in the mean, and assess the small sample performance. We apply this new test to show how the hypothesis of (perfect) hysteresis in Spanish unemployment is rejected in favour of the alternative of the natural unemployment rate, when the possibility of a change in the latter is considered.
Resumo:
Several unit root tests in panel data have recently been proposed. The test developed by Harris and Tzavalis (1999 JoE) performs particularly well when the time dimension is moderate in relation to the cross-section dimension. However, in common with the traditional tests designed for the unidimensional case, it was found to perform poorly when there is a structural break in the time series under the alternative. Here we derive the asymptotic distribution of the test allowing for a shift in the mean, and assess the small sample performance. We apply this new test to show how the hypothesis of (perfect) hysteresis in Spanish unemployment is rejected in favour of the alternative of the natural unemployment rate, when the possibility of a change in the latter is considered.
Resumo:
BACKGROUND: The objective is to develop a cost-effective, reliable and non invasive screening test able to detect early CRCs and adenomas. This is done on a nucleic acids multigene assay performed on peripheral blood mononuclear cells (PBMCs). METHODS: A colonoscopy-controlled study was conducted on 179 subjects. 92 subjects (21 CRC, 30 adenoma >1 cm and 41 controls) were used as training set to generate a signature. Other 48 subjects kept blinded (controls, CRC and polyps) were used as a test set. To determine organ and disease specificity 38 subjects were used: 24 with inflammatory bowel disease (IBD),14 with other cancers (OC). Blood samples were taken and PBMCs were purified. After the RNA extraction, multiplex RT-qPCR was applied on 92 different candidate biomarkers. After different univariate and multivariate analysis 60 biomarkers with significant p-values (<0.01) were selected. 2 distinct biomarker signatures are used to separate patients without lesion from those with CRC or with adenoma, named COLOX CRC and COLOX POL. COLOX performances were validated using random resampling method, bootstrap. RESULTS: COLOX CRC and POL tests successfully separate patients without lesions from those with CRC (Se 67%, Sp 93%, AUC 0.87), and from those with adenoma > 1cm (Se 63%, Sp 83%, AUC 0.77). 6/24 patients in the IBD group and 1/14 patients in the OC group have a positive COLOX CRC. CONCLUSION: The two COLOX tests demonstrated a high Se and Sp to detect the presence of CRCs and adenomas > 1 cm. A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.
Resumo:
Background: Detection rates for adenoma and early colorectal cancer (CRC) are unsatisfactory due to low compliance towards invasive screening procedures such as colonoscopy. There is a large unmet screening need calling for an accurate, non-invasive and cost-effective test to screen for early neoplastic and pre-neoplastic lesions. Our goal is to identify effective biomarker combinations to develop a screening test aimed at detecting precancerous lesions and early CRC stages, based on a multigene assay performed on peripheral blood mononuclear cells (PBMC).Methods: A pilot study was conducted on 92 subjects. Colonoscopy revealed 21 CRC, 30 adenomas larger than 1 cm and 41 healthy controls. A panel of 103 biomarkers was selected by two approaches: a candidate gene approach based on literature review and whole transcriptome analysis of a subset of this cohort by Illumina TAG profiling. Blood samples were taken from each patient and PBMC purified. Total RNA was extracted and the 103 biomarkers were tested by multiplex RT-qPCR on the cohort. Different univariate and multivariate statistical methods were applied on the PCR data and 60 biomarkers, with significant p-value (< 0.01) for most of the methods, were selected.Results: The 60 biomarkers are involved in several different biological functions, such as cell adhesion, cell motility, cell signaling, cell proliferation, development and cancer. Two distinct molecular signatures derived from the biomarker combinations were established based on penalized logistic regression to separate patients without lesion from those with CRC or adenoma. These signatures were validated using bootstrapping method, leading to a separation of patients without lesion from those with CRC (Se 67%, Sp 93%, AUC 0.87) and from those with adenoma larger than 1cm (Se 63%, Sp 83%, AUC 0.77). In addition, the organ and disease specificity of these signatures was confirmed by means of patients with other cancer types and inflammatory bowel diseases.Conclusions: The two defined biomarker combinations effectively detect the presence of CRC and adenomas larger than 1 cm with high sensitivity and specificity. A prospective, multicentric, pivotal study is underway in order to validate these results in a larger cohort.
Resumo:
Personality differences based on fine motor precision performance were studied in early stage Parkinson's patients and an age-matched control group under two different test conditions: proprioceptive + visual information and proprioceptive information alone. A comparative data analysis for deviations of three measured movement types (transversal, frontal and sagittal) was done for both hands (dominant and non-dominant) with relation to personality dimensions. There were found significant differences between the two groups in decision making dimension and emotionality. After splitting the data for gender subgroups, some significant differences were found for men but not for women. The differences in fine motor task performance varied, being better in some directions for the Parkinson"s patients and worse in others. The findings may suggest that medication has both positive and negative effects on motor performance and provoke personality changes, being more pronounced in men.
Resumo:
Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.
Resumo:
The fiscal policy rule implicit in the Stability and Growth Pact, has been rationalised as a way to ensure that national fiscal policies remain sustainable within the EU, thereby endorsing the independence of the ECB. We empirically examine the sustainability of European fiscal policies over the period 1970-2001. The intertemporal government budget constraint provides a test based on the cointegration relation between government revenues, expenditures and interest payments. Sustainability is analysed at both the national level and for a European panel. Results show that European fiscal policy has been sustainable overall, yet national experiences differ considerably.
Resumo:
Two sensitive spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsule formulation. The methods are based on the oxidation of lansoprazole by insitu generated bromine followed by determination of unreacted bromine by two different reaction schemes. In one procedure (method A), the residual bromine is treated with excess of iron (II), and the resulting iron (III) is complexed with thiocyanate and measured at 470 nm. The second approach (method B) involves treating the unreacted bromine with a measured excess of iron (II) and remaining iron (II) is complexed with orthophenanthroline at a raised pH, and measured at 510 nm. In both methods, the amount of bromine reacted corresponds to the amount of LPZ. The experimental conditions were optimized. In method A, the absorbance is found to decrease linearly with the concentration of LPZ (r = -0.9986) where as in the method B a linear increase in absorbance occurs (r = 0.9986) The systems obey Beer's law for 0.5-4.0 and 0.5-6.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 3.97µ10(4) and 3.07µ10(4) L mol-1cm-1 for method A and method B, respectively, and the corresponding Sandell sensitivity values are 0.0039 and 0.0013 µg cm-2. The limit of detection (LOD) and quantification (LOQ) are also reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim and the results were statistically compared with those of a reference method by applying the Student's t-test and F-test. No interference was observed from the concomitant substances normally added to capsules. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard-addition method.
Resumo:
Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of ferroin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves the reduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is complexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were optimized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer's law for 0.6-7.5 and 0.5-5.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 10(4) and 1.06 X 10(5) Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039µg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student's t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.