980 resultados para Reliability testing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study is to assess the structural and cross-cultural validity of the KIDSCREEN-27 questionnaire. METHODS: The 27-item version of the KIDSCREEN instrument was derived from a longer 52-item version and was administered to young people aged 8-18 years in 13 European countries in a cross-sectional survey. Structural and cross-cultural validity were tested using multitrait multi-item analysis, exploratory and confirmatory factor analysis, and Rasch analyses. Zumbo's logistic regression method was applied to assess differential item functioning (DIF) across countries. Reliability was assessed using Cronbach's alpha. RESULTS: Responses were obtained from n = 22,827 respondents (response rate 68.9%). For the combined sample from all countries, exploratory factor analysis with procrustean rotations revealed a five-factor structure which explained 56.9% of the variance. Confirmatory factor analysis indicated an acceptable model fit (RMSEA = 0.068, CFI = 0.960). The unidimensionality of all dimensions was confirmed (INFIT: 0.81-1.15). Differential item functioning (DIF) results across the 13 countries showed that 5 items presented uniform DIF whereas 10 displayed non-uniform DIF. Reliability was acceptable (Cronbach's alpha = 0.78-0.84 for individual dimensions). CONCLUSIONS: There was substantial evidence for the cross-cultural equivalence of the KIDSCREEN-27 across the countries studied and the factor structure was highly replicable in individual countries. Further research is needed to correct scores based on DIF results. The KIDSCREEN-27 is a new short and promising tool for use in clinical and epidemiological studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Prolonged sacral neuromodulation (SNM) testing is more reliable for accurate patient selection than the usual test period of 4-7 days. However, prolonged testing was suspected to result in a higher complication rate due to infection via the percutaneous passage of the extension wire. Therefore, we prospectively assessed the complications associated with prolonged tined lead testing. PATIENTS AND METHODS: A consecutive series of 44 patients who underwent prolonged tined lead testing for at least 14 days between May 2002 and April 2007 were evaluated. Complications during prolonged tined lead testing, during and after tined lead explantation and during follow-up after implantation of the implantable pulse generator (IPG) were registered prospectively. RESULTS: Four patients suffered from urgency-frequency syndrome, 13 from urge incontinence, 18 from non-obstructive chronic urinary retention and nine from chronic pelvic pain syndrome. The median test phase was 30 days (interquartile range [IQR] 21-36). Thirty-two of the 44 patients (73%) had successful prolonged tined lead testing and 31 of these (97%) underwent the implantation of the IPG. The median follow-up of the IPG implanted patients was 31 months (IQR 20-41). The complication rate was 5% (2/44) during prolonged tined lead testing and 16% (5/31) during follow-up of the IPG implanted patients, respectively. None of the complications could be attributed to prolonged testing. No infections were observed during the study period. CONCLUSIONS: This prospective, observational non-randomised study suggests prolonged SNM tined lead testing is a safe procedure. Based on the low complication rate and the increased reliability for accurate patient selection, this method is proposed as a possible standard test procedure, subject to confirmation by further randomised, controlled clinical studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A graphing method was developed and tested to estimate gestational ages pre-and postnatally in a consistent manner for epidemiological research and clinical purposes on feti/infants of women with few consistent prenatal estimators of gestational age. Each patient's available data was plotted on a single page graph to give a comprehensive overview of that patient. A hierarchical classification of gestational age determination was then applied in a systematic manner, and reasonable gestational age estimates were produced. The method was tested for validity and reliability on 50 women who had known dates for their last menstrual period or dates of conception, and multiple ultrasound examinations and other gestational age estimating measures. The feasibility of the procedure was then tested on 1223 low income women with few gestational age estimators. The graphing method proved to have high inter- and intrarater reliability. It was quick, easy to use, inexpensive, and did not require special equipment. The graphing method estimate of gestational age for each infant was tested against the last menstrual period gestational age estimate using paired t-Tests, F tests and the Kolmogorov-Smirnov test of similar populations, producing a 98 percent probability or better that the means and data populations were the same. Less than 5 percent of the infants' gestational ages were misclassified using the graphing method, much lower than the amount of misclassification produced by ultrasound or neonatal examination estimates. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION AND HYPOTHESIS The prevalence of female stress urinary incontinence is high, and young adults are also affected, including athletes, especially those involved in "high-impact" sports. To date there have been almost no studies testing pelvic floor muscle (PFM) activity during dynamic functional whole body movements. The aim of this study was the description and reliability test of PFM activity and time variables during running. METHODS A prospective cross-sectional study including ten healthy female subjects was designed with the focus on the intra-session test-retest reliability of PFM activity and time variables during running derived from electromyography (EMG) and accelerometry. RESULTS Thirteen variables were identified based on ten steps of each subject: Six EMG variables showed good reliability (ICC 0.906-0.942) and seven time variables did not show good reliability (ICC 0.113-0.731). Time variables (e.g. time difference between heel strike and maximal acceleration of vaginal accelerator) showed low reliability. However, relevant PFM EMG variables during running (e.g., pre-activation, minimal and maximal activity) could be identified and showed good reliability. CONCLUSION Further adaptations regarding measurement methods should be tested to gain better control of the kinetics and kinematics of the EMG probe and accelerometers. To our knowledge this is the first study to test the reliability of PFM activity and time variables during dynamic functional whole body movements. More knowledge of PFM activity and time variables may help to provide a deeper insight into physical strain with high force impacts and important functional reflexive contraction patterns of PFM to maintain or to restore continence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Stress urinary incontinence (SUI) affects women of all ages including young athletes, especially those involved in high-impact sports. To date, hardly any studies are available testing pelvic floor muscles (PFM) during sports activities. The aim of this study was the description and reliability test of six PFM electromyography (EMG) variables during three different running speeds. The secondary objective was to evaluate whether there was a speed-dependent difference between the PFM activity variables. METHODS This trial was designed as an exploratory and reliability study including ten young healthy female subjects to characterize PFM pre-activity and reflex activity during running at 7, 9 and 11 km/h. Six variables for each running speed, averaged over ten steps per subject, were presented descriptively, tested regarding their reliability (Friedman, ICC, SEM, MD) and speed difference (Friedman). RESULTS PFM EMG variables varied between 67.6 and 106.1 %EMG, showed no systematic error and were low for SEM and MD using the single value model. Applying the average model over ten steps, ICC (3,k) were >0.75 and SEM and MD about 50 % lower than for the single value model. Activity was found to be highest in 11 km/h. CONCLUSION EMG variables showed excellent ICC and very low SEM and MD. Further studies should investigate inter-session reliability and PFM reactivity patterns of SUI patients using the average over ten steps for each variable as it showed very high ICC and very low SEM and MD. Subsequently, longer running distances and other high-impact sports disciplines could be studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Due to the lack of exercise testing devices that can be employed in stroke patients with severe disability, the aim of this PhD research was to investigate the clinical feasibility of using a robotics-assisted tilt table (RATT) as a method for cardiopulmonary exercise testing (CPET) and exercise training in stroke patients. For this purpose, the RATT was augmented with force sensors, a visual feedback system and a work rate calculation algorithm. As the RATT had not been used previously for CPET, the first phase of this project focused on a feasibility study in 11 healthy able-bodied subjects. The results demonstrated substantial cardiopulmonary responses, no complications were found, and the method was deemed feasible. The second phase was to analyse validity and test-retest reliability of the primary CPET parameters obtained from the RATT in 18 healthy able-bodied subjects and to compare the outcomes to those obtained from standard exercise testing devices (a cycle ergometer and a treadmill). The results demonstrated that peak oxygen uptake (V'O2peak) and oxygen uptake at the submaximal exercise thresholds on the RATT were ̴20% lower than for the cycle ergometer and ̴30% lower than on the treadmill. A very high correlation was found between the RATT vs the cycle ergometer V'O2peak and the RATT vs the treadmill V'O2peak. Test-retest reliability of CPET parameters obtained from the RATT were similarly high to those for standard exercise testing devices. These findings suggested that the RATT is a valid and reliable device for CPET and that it has potential to be used in severely impaired patients. Thus, the third phase was to investigate using the RATT for CPET and exercise training in 8 severely disabled stroke patients. The method was technically implementable, well tolerated by the patients, and substantial cardiopulmonary responses were observed. Additionally, all patients could exercise at the recommended training intensity for 10 min bouts. Finally, an investigation of test-retest reliability and four-week changes in cardiopulmonary fitness was carried out in 17 stroke patients with various degrees of disability. Good to excellent test-retest reliability and repeatability were found for the main CPET variables. There was no significant difference in most CPET parameters over four weeks. In conclusion, based on the demonstrated validity, reliability and repeatability, the RATT was found to be a feasible and appropriate alternative exercise testing and training device for patients who have limitations for use of standard devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Not only has obesity played a role in Texas adults but it is also becoming a large issue among low-income Latino children. In Latino children between 2-5 years of age, the Pediatric Nutrition Surveillance data in 1997 found the prevalence of obesity was 12 percent, highest among all ethnic groups. Children learn what and how to eat from their environment. Despite many mothers being working mothers they are still the principal caregivers and source of influence on their toddler's diet. Self-efficacy, a concept created by Albert Bandura, one's belief that one is capable of performing a behavior needed to reach an intended goal, is increasingly becoming important in nutrition and health education. This study is important to understand the degree of impact that a mother's self-efficacy will have on a child's diet. This is useful knowing if influencing a mother's self-efficacy could improve a child's diet to prevent certain public health issues such as obesity and diabetes. The purpose of this study was to examine nutrition self-efficacy of Latina mothers, focusing on sweets and beverage and if their self-efficacy impacted their child's diet. Methods. The data was collected during July-September 2008. Mothers were recruited from two federally qualified San Antonio health centers. In order to qualify, participants had to be Hispanic with children of toddler age. Mothers were informed of incentives available upon completion. The interview consisted of demographic info, a set of five self-efficacy questions repeated at completion, testing reliability and a 24-hour food recall diary asked of the participant's child's diet. Results. There were 225 mothers who participated between both clinics. The Crohnbach alpha scores for the two different times the self-efficacy questions were asked were .44 corresponding to the first time and .49 for the second time. The three most common beverages reported were milk, juice, and water. The mothers who met or gave their child more milk than recommended by the scientific community, 800mg of calcium/3 cups (24oz) set, had a higher self-efficacy score than those who did not meet the standard at all. Mothers who gave their children more juice than the standard recommends, 4-6oz for children 1-6 years of age, had slightly higher self-efficacy scores than mother's who simply met the standard. In general, the lower the mother's self-efficacy, the more sweets they gave their child and vice versa. Conclusion. This study's Kappa values were adequate and this research showed that Latina mothers did in fact have high self-efficacy. In general some of the children's diets did not reflect the current scientific nutrition recommendations. In order to improve self-efficacy and have an impact on children's diets, the scientific community has a responsibility to make recommendations that are easily understood and can be put into practice. The public health community needs to ensure that we encourage those we serve to be more active in their health and educate them about what constitutes good health and nutrition for both themselves and their children.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. At present, prostate cancer screening (PCS) guidelines require a discussion of risks, benefits, alternatives, and personal values, making decision aids an important tool to help convey information and to help clarify values. Objective: The overall goal of this study is to provide evidence of the reliability and validity of a PCS anxiety measure and the Decisional Conflict Scale (DCS). Methods. Using data from a randomized, controlled PCS decision aid trial that measured PCS anxiety at baseline and DCS at baseline (T0) and at two-weeks (T2), four psychometric properties were assessed: (1) internal consistency reliability, indicated by factor analysis intraclass correlations and Cronbach's α; (2) construct validity, indicated by patterns of Pearson correlations among subscales; (3) discriminant validity, indicated by the measure's ability to discriminate between undecided men and those with a definite screening intention; and (4) factor validity and invariance using confirmatory factor analyses (CFA). Results. The PCS anxiety measure had adequate internal consistency reliability and good construct and discriminant validity. CFAs indicated that the 3-factor model did not have adequate fit. CFAs for a general PCS anxiety measure and a PSA anxiety measure indicated adequate fit. The general PCS anxiety measure was invariant across clinics. The DCS had adequate internal consistency reliability except for the support subscale and had adequate discriminate validity. Good construct validity was found at the private clinic, but was only found for the feeling informed subscale at the public clinic. The traditional DCS did not have adequate fit at T0 or at T2. The alternative DCS had adequate fit at T0 but was not identified at T2. Factor loadings indicated that two subscales, feeling informed and feeling clear about values, were not distinct factors. Conclusions. Our general PCS anxiety measure can be used in PCS decision aid studies. The alternative DCS may be appropriate for men eligible for PCS. Implications: More emphasis needs to be placed on the development of PCS anxiety items relating to testing procedures. We recommend that the two DCS versions be validated in other samples of men eligible for PCS and in other health care decisions that involve uncertainty. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the advent of the Universal Technical Standard for Solar Home Systems, procedures to test the compliance of SHS fluorescent lamps with the standard have been developed. Definition of the laboratory testing procedures is a necessary step in any lamp quality assurance procedure. Particular attention has been paid to test simplicity and to affordability, in order to facilitate local application of the testing procedures, for example by the organisations which carry out electrification programmes. The set of test procedures has been applied to a representative collection of 42 lamps from many different countries, directly acquired in the current photovoltaic rural electrification market. Tests apply to: lamp resistance under normal operating conditions; lamp reliability under extreme conditions; under abnormal conditions; and lamp luminosity. Results are discussed and some recommendations for updating the relevant standard are given. The selected technical standard, together with the proposed testing procedures, form the basis of a complete quality assurance tool that can be applied locally in normal electrical laboratories. Full testing of a lamp requires less than one month, which is very reasonable on the context of quality assurance programmes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Software testing is a key aspect of software reliability and quality assurance in a context where software development constantly has to overcome mammoth challenges in a continuously changing environment. One of the characteristics of software testing is that it has a large intellectual capital component and can thus benefit from the use of the experience gained from past projects. Software testing can, then, potentially benefit from solutions provided by the knowledge management discipline. There are in fact a number of proposals concerning effective knowledge management related to several software engineering processes. Objective: We defend the use of a lesson learned system for software testing. The reason is that such a system is an effective knowledge management resource enabling testers and managers to take advantage of the experience locked away in the brains of the testers. To do this, the experience has to be gathered, disseminated and reused. Method: After analyzing the proposals for managing software testing experience, significant weaknesses have been detected in the current systems of this type. The architectural model proposed here for lesson learned systems is designed to try to avoid these weaknesses. This model (i) defines the structure of the software testing lessons learned; (ii) sets up procedures for lesson learned management; and (iii) supports the design of software tools to manage the lessons learned. Results: A different approach, based on the management of the lessons learned that software testing engineers gather from everyday experience, with two basic goals: usefulness and applicability. Conclusion: The architectural model proposed here lays the groundwork to overcome the obstacles to sharing and reusing experience gained in the software testing and test management. As such, it provides guidance for developing software testing lesson learned systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the consolidation of the new solid state lighting LEOs devices, te5t1n9 the compliance 01 lamps based on this technology lor Solar Home Systems (SHS) have been analyzed. The definition of the laboratory procedures to be used with final products 15 a necessary step in arder to be able to assure the quality of the lamps prior to be installed [1]. As well as with CFL technology. particular attention has been given to simplicity and technical affordability in arder to facilitate the implementation of the test with basie and simple laboratory too15 even on the same SHS electrification program locations. The block of test procedures has been applied to a set of 14 low-cost lamps. They apply to lamp resistance, reliability and performance under normal, extreme and abnormal operating conditions as a simple but complete quality meter tool 01 any LEO bulb.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experiences in decentralized rural electrification programmes using solar home systems have suffered difficulties during the operation and maintenance phase, due in many cases, to the underestimation of the maintenance cost, because of the decentralized character of the activity, and also because the reliability of the solar home system components is frequently unknown. This paper reports on the reliability study and cost characterization achieved in a large photovoltaic rural electrification programme carried out in Morocco. The paper aims to determinate the reliability features of the solar systems, focusing in the in-field testing for batteries and photovoltaic modules. The degradation rates for batteries and PV modules have been extracted from the in-field experiments. On the other hand, the main costs related to the operation and maintenance activity have been identified with the aim of establishing the main factors that lead to the failure of the quality sustainability in many rural electrification programmes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The definition of technical specifications and the corresponding laboratory procedures are necessary steps in order to assure the quality of the devices prior to be installed in Solar Home Systems (SHS). To clarify and unify criteria a European project supported the development of the Universal Technical Standard for Solar Home Systems (UTSfSHS). Its principles were to generate simple and affordable technical requirements to be optimized in order to facilitate the implementation of tests with basic and simple laboratory tools even on the same SHS electrification program countries. These requirements cover the main aspects of this type of installations and its lighting chapter was developed based on the most used technology at that time: fluorescent tubes and CFLs. However, with the consolidation of the new LED solid state lighting devices, particular attention is being given to this matter and new procedures are required. In this work we develop a complete set of technical specifications and test procedures that have been designed within the frame of the UTSfSHS, based on an intense review of the scientific and technical publications related to LED lighting and their practical application. They apply to lamp reliability, performance and safety under normal, extreme and abnormal operating conditions as a simple but complete quality meter tool for any LED bulb.