985 resultados para Reliability index


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to refine a multi-dimensional scale based on physiological and behavioural parameters, known as the post abdominal surgery pain assessment scale (PASPAS), to quantify pain after laparotomy in horses. After a short introduction, eight observers used the scale to assess eight horses at multiple time points after laparotomy. In addition, a single observer was used to test the correlation of each parameter with the total pain index in 34 patients, and the effect of general anaesthesia on PASPAS was investigated in a control group of eight horses. Inter-observer variability was low (coefficient of variation 0.3), which indicated good reliability of PASPAS. The correlation of individual parameters with the total pain index differed between parameters. PASPAS, which was not influenced by general anaesthesia, was a useful tool to evaluate pain in horses after abdominal surgery and may also be useful to investigate analgesic protocols or for teaching purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare standard plaster models with their digital counterparts for the applicability of the Index of Complexity, Outcome, and Need (ICON). Generated study models of 30 randomly selected patients: 30 pre- (T(0)) and 30 post- (T(1)) treatment. Two examiners, calibrated in the ICON, scored the digital and plaster models. The overall ICON scores were evaluated for reliability and reproducibility using kappa statistics and reliability coefficients. The values for reliability of the total and weighted ICON scores were generally high for the T(0) sample (range 0.83-0.95) but less high for the T(1) sample (range 0.55-0.85). Differences in total ICON score between plaster and digital models resulted in mostly statistically insignificant values (P values ranging from 0.07 to 0.19), except for observer 1 in the T(1) sample. No statistically different values were found for the total ICON score on either plaster or digital models. ICON scores performed on computer-based models appear to be as accurate and reliable as ICON scores on plaster models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

QUESTION UNDER STUDY: Purpose was to validate accuracy and reliability of automated oscillometric ankle-brachial (ABI) measurement prospectively against the current gold standard of Doppler-assisted ABI determination. METHODS: Oscillometric ABI was measured in 50 consecutive patients with peripheral arterial disease (n = 100 limbs, mean age 65 +/- 6 years, 31 men, 19 diabetics) after both high and low ABI had been determined conventionally by Doppler under standardised conditions. Correlation was assessed by linear regression and Pearson product moment correlation. Degree of inter-modality agreement was quantified by use of Bland and Altman method. RESULTS: Oscillometry was performed significantly faster than Doppler-assisted ABI (3.9 +/- 1.3 vs 11.4 +/- 3.8 minutes, P <0.001). Mean readings were 0.62 +/- 0.25, 0.70 +/- 0.22 and 0.63 +/- 0.39 for low, high and oscillometric ABI, respectively. Correlation between oscillometry and Doppler ABI was good overall (r = 0.76 for both low and high ABI) and excellent in oligo-symptomatic, non-diabetic patients (r = 0.81; 0.07 +/- 0.23); it was, however, limited in diabetic patients and in patients with critical limb ischaemia. In general, oscillometric ABI readings were slightly higher (+0.06), but linear regression analysis showed that correlation was sustained over the whole range of measurements. CONCLUSIONS: Results of automated oscillometric ABI determination correlated well with Doppler-assisted measurements and could be obtained in shorter time. Agreement was particularly high in oligo-symptomatic non-diabetic patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lucid dream and nightmare frequencies vary greatly between individuals and to assess these differences reliable instruments are needed. The present study aimed to examine the reliability of eight-point scales for measuring lucid dream and nightmare frequencies. The scales were administered twice (with a four-week interval) to 93 sport students. A re-test reliability for the lucid dream frequency was found r=.89 (p<.001) and for the nightmare frequency r=.75 (p<.001). Both eight-point scales appear to be reliable measures for assessing individual differences in lucid dream and nightmare frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Critically ill and injured patients require pain relief and sedation to reduce the body's stress response and to facilitate painful diagnostic and therapeutic procedures. Presently, the level of sedation and analgesia is guided by the use of clinical scores which can be unreliable. There is therefore, a need for an objective measure of sedation and analgesia. The Bispectral Index (BIS) and Patient State Index (PSI) were recently introduced into clinical practice as objective measures of the depth of analgesia and sedation. ^ Aim. To compare the different measures of sedation and analgesia (BIS and PSI) to the standard and commonly used modified Ramsay Score (MRS) and determine if the monitors can be used interchangeably. ^ Methods. MRS, BIS and PSI values were obtained in 50 postoperative cardiac surgery patients requiring analgesia and sedation from June to December 2004. The MRS, BIS and PSI values were assessed hourly for up to 6-h by a single observer. ^ The relationship between BIS and PSI values were explored using scatter plots and correlation between MRS, BIS and PSI was determined using Spearman's correlation coefficient. Intra-class correlation (ICC) was used to determine the inter-rater reliability of MRS, BIS and PSI. Kappa statistics was used to further evaluate the agreement between BIS and PSI at light, moderate and deep levels of sedation. ^ Results. There was a positive correlation between BIS and PSI values (Rho = 0.731, p<0.001). Intra-class correlation between BIS and PSI was 0.58, MRS and BIS 0.43 and MRS and PSI 0.27. Using Kappa statistics, agreement between MRS and BIS was 0.35 (95% CI: 0.27–0.43) and for MRS and PSI was 0.21 (95% CI: 0.15–0.28). The kappa statistic for BIS and PSI was 0.45 (95% CI: 0.37–0.52). Receiver operating characteristics (ROC) curves constructed to detect undersedation indicated an area under the curve (AUC) of 0.91 (95% CI = 0.87 to 0.94) for the BIS and 0.84 (95% CI = 0.79 to 0.88) for the PSI. For detection of oversedation, AUC for the BIS was 0.89 (95% CI = 0.84 to 0.92) and 0.80 (95% CI = 0.75 to 0.85) for the PSI. ^ Conclusions. There is a statistically significant positive correlation between the BIS and PSI but poor correlation and poor test agreement between the MRS and BIS as well as MRS and PSI. Both the BIS and PSI demonstrated a high level of prediction for undersedation and oversedation; however, the BIS and PSI can not be considered interchangeable monitors of sedation. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To assess the measurement properties of a simple index of symptom severity in osteoarthritis (OA) of the hips and knees. Methods. Both the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the proposed new Comprehensive Osteoarthritis Test (COAT) instrument were completed weekly by 125 subjects in the context of a randomized, 12-week, 3 parallel-arm clinical trial. The reliabilities of the various scales were assessed on a weekly basis by use of Cronbach's alpha coefficients. The validity of the COAT total scale was assessed by correlation with the WOMAC total scale on a weekly basis with correlation coefficients, and in terms of the correlations between subject-level intercepts and slopes over time. The relative responsiveness of the WOMAC and COAT total scales was assessed using a multilevel (longitudinal) multivariate (WOMAC, COAT) linear model. Results. The WOMAC and COAT total scales were highly reliable (mean over weeks: WOMAC alpha = 0.98; COAT alpha = 0.97). The correlations between the WOMAC and COAT scales were very high (mean over weeks = 0.92; subject-level intercepts = 0.91, slopes = 0.88). The COAT total scale was significantly more responsive than the WOMAC total scale in the active treatment (34.8% improvement vs 26.8%; p = 0.002). Conclusion. The COAT total scale is simple to administer, reliable, valid, and responsive to treatment effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present investigation aimed to critically examine the factor structure and psychometric properties of the Anxiety Sensitivity Index - Revised (ASI-R). Confirmatory factor analysis using a clinical sample of adults (N = 248) revealed that the ASI-R could be improved substantially through the removal of 15 problematic items in order to account for the most robust dimensions of anxiety sensitivity. This modified scale was renamed the 21-item Anxiety Sensitivity Index (21-item ASI) and reanalyzed with a large sample of normative adults (N = 435), revealing configural and metric invariance across groups. Further comparisons with other alternative models, using multi-sample analysis, indicated the 21-item ASI to be the best fitting model for both groups. There was also evidence of internal consistency, test-retest reliability, and construct validity for both samples suggesting that the 21-item ASI is a useful assessment device for investigating the construct of anxiety sensitivity in both clinical and normative populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The annealing properties of Type IA Bragg gratings are investigated and compared with Type I and Type IIA Bragg gratings. The transmission properties (mean and modulated wavelength components) of gratings held at predetermined temperatures are recorded from which decay characteristics are inferred. Our data show critical results concerning the high temperature stability of Type IA gratings, as they undergo a drastic initial decay at 100°C, with a consequent mean index change that is severely reduced at this temperature However, the modulated index change of IA gratings remains stable at lower annealing temperatures of 80°C, and the mean index change decays at a comparable rate to Type I gratings at 80°C. Extending this work to include the thermal decay of Type IA gratings inscribed under strain shows that the application of strain quite dramatically transforms the temperature characteristics of the Type IA grating, modifying the temperature coefficient and annealing curves, with the grating showing a remarkable improvement in high temperature stability, leading to a robust grating that can survive temperatures exceeding 180°C. Under conditions of inscription under strain it is found that the temperature coefficient increases, but is maintained at a value considerably different to the Type I grating. Therefore, the combination of Type I and IA (strained) gratings make it possible to decouple temperature and strain over larger temperature excursions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The International FItness Scale (IFIS) is a self-reported measure of physical fitness that could easily. This scale has been validated in children, adolescents, and young adults; however, it is unknown whether the IFIS represents a valid and reliable estimate of physical fitness in Latino-American youth population. In the present study we aimed to examine the validity and reliability of the IFIS on a population-based sample of schoolchildren in Bogota, Colombia. Participants were 1,875 Colombian youth (56.2% girls) aged 9 to 17.9 years old. We measured adiposity markers (body fat, waist-to-height ratio, skinfold thicknesses and BMI), blood pressure, lipids profile, fasting glucose, and physical fitness level (self reported and measured). Also, a validated cardiometabolic risk index was used. An age- and sex-matched sample of 229 Schoolchildren originally not included in the study sample fulfilled IFIS twice for reliability purposes. Our data suggest that both measured and self-reported overall fitness were associated inversely with adiposity indicators and a cardiometabolic risk score. Overall, schoolchildren who self-reported “good” and “very good” fitness had better measured fitness than those who reported “very poor” and “poor” fitness (all p<0.001). Test–retest reliability of IFIS items was also good, with an average weighted Kappa of 0.811. Therefore, our findings suggest that self-reported fitness, as assessed by IFIS, is a valid, reliable, and health-related measure, and it can be a good alternative for future use in large studies with Latin-schoolchildren from Colombia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Objective: Evidence shows an association between muscular strength (MS) and health among youth, however low muscular strength cut-points for the detection of high metabolic risk in Latin-American populations are scarce. The aim of this study was two-fold: to explore potential age- and sex-specific thresholds of MS, for optimal cardiometabolic risk categorization among Colombian children and adolescents; and to investigate if cardiometabolic risk differed by MS group by applying the receiver operating characteristic curve (ROC) cut point. Methods: This is a secondary analysis of a cross-sectional study (the FUPRECOL study), published elsewhere. The FUPRECOL study assessments were conducted during the 2014– 2015 school year. MS was estimated by a handle dynamometer on 1,950 children and adolescents from Colombia, using the MS relative to weight (handgrip strength/body mass). A metabolic risk score was computed from the following components: waist circumference, triglycerides, HDL-c, glucose, systolic and diastolic blood pressure. ROC analysis showed a significant discriminatory accuracy of MS in identifying the low/high metabolic risk in children and adolescents and both gender. Results: In children, handgrip strength/body mass level for a low metabolic risk were 0.359 and 0.376 in girls and boys, respectively. In adolescents, these points were 0.440 and 0.447 in girls and boys, respectively. Conclusion: In conclusion, the results suggest a hypothetical MS level relative to weight for having a low metabolic risk, which could be used to identify youths at risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of the oral health of elderly people with and without a cognitive handicap was assessed. The cognitive condition, the indices of decayed, missing, filled teeth (DMFT), decayed, filled roots (DFR), the need for dental treatment, the presence of plaque (P), calculus (C), the community periodontal index (CPI), the rate of periodontal attachment loss (PAL), edentulism, prosthetic use and the need for prosthetics were evaluated in a complex probabilistic sample by conglomerates of the elderly (65-74 years). PASW(r) 17.0 was used for the statistical analyses with correction for the design effect, applying the Mann Whitney and chi-square test with 95% reliability. A total of 736 elderly individuals were interviewed and examined. Those with cognitive impairment had higher average DMFT, DFR and lower average healthy sextant CPI, a lower prevalence of sextants without plaque/calculus, use of prosthetics and higher prevalence of edentulism and need for prosthetics. Elderly individuals with a cognitive handicap had poorer oral health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

to assess the construct validity and reliability of the Pediatric Patient Classification Instrument. correlation study developed at a teaching hospital. The classification involved 227 patients, using the pediatric patient classification instrument. The construct validity was assessed through the factor analysis approach and reliability through internal consistency. the Exploratory Factor Analysis identified three constructs with 67.5% of variance explanation and, in the reliability assessment, the following Cronbach's alpha coefficients were found: 0.92 for the instrument as a whole; 0.88 for the Patient domain; 0.81 for the Family domain; 0.44 for the Therapeutic procedures domain. the instrument evidenced its construct validity and reliability, and these analyses indicate the feasibility of the instrument. The validation of the Pediatric Patient Classification Instrument still represents a challenge, due to its relevance for a closer look at pediatric nursing care and management. Further research should be considered to explore its dimensionality and content validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the relationship between parity, pre-pregnancy body mass index (BMI), and gestational weight gain (GWG). This observational controlled study was conducted from November 2013 to April 2014, with postpartum women who started antenatal care up to 14 weeks and had full-term births. Data were collected from medical records and antenatal cards. Descriptive and bivariate analyses were performed. The significance level was 5%. Data were collected from 130 primiparous and 160 multiparous women. At the beginning of prenatal care, 54.62% of the primiparous were eutrophic, while the majority of multiparous were overweight or obese (62.51%). Multiparas are two times more likely to be obese at the beginning of their pregnancies, when compared to primiparas. The average pre-pregnancy weight and final pregnancy weight was significantly higher in multiparous, however, the mean GWG was higher among primiparous. We found an inverse correlation between parity and the total GWG, but initial BMI was significantly higher in multiparas. Nevertheless, monitoring of the GWG through actions that promote a healthier lifestyle is needed, regardless of parity and nutritional status, in order to prevent excessive GWG and postpartum weight retention and consequently inadequate pre-pregnancy nutritional status in future pregnancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nutrients composition, phenolic compounds, antioxidant activity and estimated glycemic index (EGI) were evaluated in sorghum bran (SB) and decorticated sorghum flour (DSF), obtained by a rice-polisher, as well as whole sorghum flour (WSF). Correlation between EGI and the studied parameters were determined. SB presented the highest protein, lipid, ash, β-glucan, total and insoluble dietary fiber contents; and the lowest non-resistant and total starch contents. The highest carbohydrate and resistant starch contents were in DSF and WSF, respectively. Phenolic compounds and antioxidant activities were concentrated in SB. The EGI values were: DSF 84.5±0.41; WSF 77.2±0.33; and SB 60.3±0.78. Phenolic compounds, specific flavonoids and antioxidant activities, as well as total, insoluble and soluble dietary fiber and β-glucans of sorghum flour samples were all negatively correlated to EGI. RS content was not correlated to EGI.