744 resultados para Reliability and Validity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Postural instability is one of the major complications found in stroke survivors. Parameterising the functional reach test (FRT) could be useful in clinical practice and basic research. OBJECTIVES: To analyse the reliability, sensitivity, and specificity in the FRT parameterisation using inertial sensors for recording kinematic variables in patients who have suffered a stroke. DESIGN: Cross-sectional study. While performing FRT, two inertial sensors were placed on the patient's back (lumbar and trunk). PARTICIPANTS: Five subjects over 65 who suffer from a stroke. MEASUREMENTS: FRT measures, lumbosacral/thoracic maximum angular displacement, maximum time of lumbosacral/thoracic angular displacement, time return initial position, and total time. Speed and acceleration of the movements were calculated indirectly. RESULTS: FRT measure is  12.75±2.06 cm. Intrasubject reliability values range from 0.829 (time to return initial position (lumbar sensor)) to 0.891 (lumbosacral maximum angular displacement). Intersubject reliability values range from 0.821 (time to return initial position (lumbar sensor)) to 0.883 (lumbosacral maximum angular displacement). FRT's reliability was 0.987 (0.983-0.992) and 0.983 (0.979-0.989) intersubject and intrasubject, respectively. CONCLUSION: The main conclusion could be that the inertial sensors are a tool with excellent reliability and validity in the parameterization of the FRT in people who have had a stroke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. To develop and psychometrically test a survey instrument to identify the factors influencing the provision of end-of-life care by critical care nurses. Background. Following a decision to withdraw life-sustaining treatment, critical care nurses remain with the patient and their family providing end-of-life care. Identification of factors influencing the provision of this care can give evidence to inform practice development and support nurses. Design. A cross-sectional survey of critical care nurses. Method. An online survey was developed, reviewed by an expert panel and pilot tested to obtain preliminary evidence of its reliability and validity. In May 2011, a convenience sample of critical care nurses (n = 392, response rate 25%) completed the survey. The analytical approach to data obtained from the 58 items measured on a Likert scale included exploratory factor analysis and descriptive statistics. Results. Exploratory factor analysis identified eight factors influencing the provision of end-of-life care: emotional support for nurses, palliative values, patient and family preferences, resources, organizational support, care planning, knowledge and preparedness. Internal consistency of each latent construct was deemed satisfactory. The results of descriptive statistics revealed a strong commitment to the inclusion of families in end-of-life care and the value of this care in the critical care setting. Conclusion. This paper reports preliminary evidence of the psychometric properties of a new survey instrument. The findings may inform practice development opportunities to support critical care nurses in the provision of endof- life care and improve the care that patients and their families receive.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood metaphors abound in everyday social discourse among both Aboriginal and non-Aboriginal people. However, ‘Aboriginal blood talk’, more specifically, is located within a contradictory and contested space in terms of the meanings and values that can be attributed to it by Aboriginal and non-Aboriginal people. In the colonial context, blood talk operated as a tool of oppression for Aboriginal people via blood quantum discourses, yet today, Aboriginal people draw upon notions of blood, namely bloodlines, in articulating their identities. This paper juxtaposes contemporary Aboriginal blood talk as expressed by Aboriginal people against colonial blood talk and critically examines the ongoing political and intellectual governance regarding the validity of this talk in articulating Aboriginalities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To assess the performance of the 2Win eccentric videorefractor in relation to subjective refraction and table-mounted autorefraction. METHODS Eighty-six eyes of 86 adults (46 male and 40 female subjects) aged between 20 and 25 years were examined. Subjective refraction and autorefraction using the table-mounted Topcon KR8800 and the handheld 2Win videorefractor were carried out in a randomized fashion by three different masked examiners. Measurements were repeated about 1 week after to assess instrument reproducibility, and the intertest variability was compared between techniques. Agreement of the 2Win videorefractor with subjective refraction and autorefraction was assessed for sphere and for cylindrical vectors at 0 degrees (J0) and 45 degrees (J45). RESULTS Reproducibility coefficients for sphere values measured by subjective refraction, Topcon KR8800, and 2Win (±0.42, ±0.70, and ±1.18, respectively) were better than their corresponding J0 (±1.0, ±0.85, and ±1.66) and J45 (±1.01, ±0.87, and ±1.31) vector components. The Topcon KR8800 showed the most reproducible values for mean spherical equivalent refraction and the J0 and J45 vector components, whereas reproducibility of spherical component was best for subjective refraction. The 2Win videorefractor measurements were the least reproducible for all measures. All refractive components measured by the 2Win videorefractor did not differ significantly from those of subjective refraction, in both sessions (p > 0.05). The Topcon KR8800 autorefractometer and the 2Win videorefractor measured significantly more positive spheres and mean spherical equivalent refraction (p < 0.0001), but the J0 and J45 vector components were similar (p > 0.05), in both sessions. CONCLUSIONS The 2Win videorefractor compares well, on average, with subjective refraction. The reproducibility values for the 2Win videorefractor were considerably worse than either subjective refraction or autorefraction. The wide limits of reproducibility of the 2Win videorefractor probably limit its usefulness as a primary screening device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The Palliative Care Problem Severity Score is a clinician-rated tool to assess problem severity in four palliative care domains (pain, other symptoms, psychological/spiritual, family/carer problems) using a 4-point categorical scale (absent, mild, moderate, severe). Aim To test the reliability and acceptability of the Palliative Care Problem Severity Score. Design: Multi-centre, cross-sectional study involving pairs of clinicians independently rating problem severity using the tool. Setting/participants Clinicians from 10 Australian palliative care services: 9 inpatient units and 1 mixed inpatient/community-based service. Results A total of 102 clinicians participated, with almost 600 paired assessments completed for each domain, involving 420 patients. A total of 91% of paired assessments were undertaken within 2 h. Strength of agreement for three of the four domains was moderate: pain (Kappa = 0.42, 95% confidence interval = 0.36 to 0.49); psychological/spiritual (Kappa = 0.48, 95% confidence interval = 0.42 to 0.54); family/carer (Kappa = 0.45, 95% confidence interval = 0.40 to 0.52). Strength of agreement for the remaining domain (other symptoms) was fair (Kappa = 0.38, 95% confidence interval = 0.32 to 0.45). Conclusion The Palliative Care Problem Severity Score is an acceptable measure, with moderate reliability across three domains. Variability in inter-rater reliability across sites and participant feedback indicate that ongoing education is required to ensure that clinicians understand the purpose of the tool and each of its domains. Raters familiar with the patient they were assessing found it easier to assign problem severity, but this did not improve inter-rater reliability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Surgery is an example of expanded practice scope that enhances podiatry and incorporates inter-professional collaboration. By 2050 demand for foot and ankle procedures is predicted to rise nationally by 61.9%. Performance management of this increase motivated the development of an online audit tool. Developed in collaboration with the Australasian College of Podiatric Surgeons (ACPS), the ACPS audit tool provides real-time data capture and reporting. It is the first audit tool designed in Australia to support and improve the outcomes of foot and ankle surgery. Methods Audit activity in general, orthopaedic, plastic and podiatric surgery was examined using a case study design. Audit participation enablers and barriers were explored. Case study results guided a Delphi survey of international experts experienced or associated with foot and ankle surgery. Delphi survey-derived consensus informed modification of a generic data set from the Royal Australasian College of Surgeons (RACS). Based on the Delphi survey findings the ACPS online audit tool was developed and piloted. Reliability and validity of data entry and usability of this new tool was then assessed with an online survey. Results The case study found surgeon attitudes and behaviours positively impacted audit participation, and also indicated that audit data should be: (1) available in real time, (2) identify practice change, (3) applicable for safety and quality management, and; (4) useful for peer review discussion. The Delphi process established consensus on audit variables to be captured, including the modified RACS generic data set. 382 cases of foot and ankle surgery were captured across 3 months using the new tool. Data entry was found to be valid and reliable. Real-time outcome reporting and practice change identification impacted positively on safety and quality management and assisted peer review discussion. An online survey showed high levels of usability. Conclusions Surgeon contribution to audit tool development resulted in 100% audit participation. The data from the ACPS audit tool supported the ACPS submission to the Medical Services Advisory Committee to list podiatric surgery under Medicare, an outcome noted by the Federal Minister of Health.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim Psychotic-like experiences (PLEs) are common in young people and are associated with both distress and adverse outcomes. The Community Assessment of Psychic Experiences-Positive Scale (CAPE-P) provides a 20-item measure of lifetime PLEs. A 15-item revision of this scale was recently published (CAPE-P15). Although the CAPE-P has been used to assess PLEs in the last 12 months, there is no version of the CAPE for assessing more recent PLEs (e.g. 3 months). This study aimed to determine the reliability and validity of the current CAPE-P15 and assess its relationship with current distress. Method A cross-sectional online survey of 489 university students (17–25 years) assessed lifetime and current substance use, current distress, and lifetime and 3-month PLEs on the CAPE-P15. Results Confirmatory factor analysis indicated that the current CAPE-P15 retained the same three-factor structure as the lifetime version consisting of persecutory ideation, bizarre experiences and perceptual abnormalities. The total score of the current version was lower than the lifetime version, but the two were strongly correlated (r = .64). The current version was highly predictive of generalized distress (r = .52) and indices that combined symptom frequency with associated distress did not confer greater predictive power than frequency alone. Conclusion This study provided preliminary data that the current CAPE-P15 provides a valid and reliable measure of current PLEs. The current CAPE-P15 is likely to have substantial practical utility if it is later shown to be sensitive to change, especially in prevention and early intervention for mental disorders in young people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Models are abstractions of reality that have predetermined limits (often not consciously thought through) on what problem domains the models can be used to explore. These limits are determined by the range of observed data used to construct and validate the model. However, it is important to remember that operating the model beyond these limits, one of the reasons for building the model in the first place, potentially brings unwanted behaviour and thus reduces the usefulness of the model. Our experience with the Agricultural Production Systems Simulator (APSIM), a farming systems model, has led us to adapt techniques from the disciplines of modelling and software development to create a model development process. This process is simple, easy to follow, and brings a much higher level of stability to the development effort, which then delivers a much more useful model. A major part of the process relies on having a range of detailed model tests (unit, simulation, sensibility, validation) that exercise a model at various levels (sub-model, model and simulation). To underline the usefulness of testing, we examine several case studies where simulated output can be compared with simple relationships. For example, output is compared with crop water use efficiency relationships gleaned from the literature to check that the model reproduces the expected function. Similarly, another case study attempts to reproduce generalised hydrological relationships found in the literature. This paper then describes a simple model development process (using version control, automated testing and differencing tools), that will enhance the reliability and usefulness of a model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To develop the DCDDaily, an instrument for objective and standardized clinical assessment of capacity in activities of daily living (ADL) in children with developmental coordination disorder (DCD), and to investigate its usability, reliability, and validity. Subjects Five to eight-year-old children with and without DCD. Main measures The DCDDaily was developed based on thorough review of the literature and extensive expert involvement. To investigate the usability (assessment time and feasibility), reliability (internal consistency and repeatability), and validity (concurrent and discriminant validity) of the DCDDaily, children were assessed with the DCDDaily and the Movement Assessment Battery for Children-2 Test, and their parents filled in the Movement Assessment Battery for Children-2 Checklist and Developmental Coordination Disorder Questionnaire. Results 459 children were assessed (DCD group, n = 55; normative reference group, n = 404). Assessment was possible within 30 minutes and in any clinical setting. For internal consistency, Cronbach’s α = 0.83. Intraclass correlation = 0.87 for test–retest reliability and 0.89 for inter-rater reliability. Concurrent correlations with Movement Assessment Battery for Children-2 Test and questionnaires were ρ = −0.494, 0.239, and −0.284, p < 0.001. Discriminant validity measures showed significantly worse performance in the DCD group than in the control group (mean (SD) score 33 (5.6) versus 26 (4.3), p < 0.001). The area under curve characteristic = 0.872, sensitivity and specificity were 80%. Conclusions The DCDDaily is a valid and reliable instrument for clinical assessment of capacity in ADL, that is feasible for use in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A randomised and population-based screening design with new technologies has been applied to the organised cervical cancer screening programme in Finland. In this experiment the women invited to routine five-yearly screening are individually randomised to be screened with automation-assisted cytology, human papillomavirus (HPV) test or conventional cytology. By using the randomised design, the ultimate aim is to assess and compare the long-term outcomes of the different screening regimens. The primary aim of the current study was to evaluate, based on the material collected during the implementation phase of the Finnish randomised screening experiment, the cross-sectional performance and validity of automation-assisted cytology (Papnet system) and primary HPV DNA testing (Hybrid Capture II assay for 13 oncogenic HPV types) within service screening, in comparison to conventional cytology. The parameters of interest were test positivity rate, histological detection rate, relative sensitivity, relative specificity and positive predictive value. Also, the effect of variation in performance by screening laboratory on age-adjusted cervical cancer incidence was assessed. Based on the cross-sectional results, almost no differences were observed in the performance of conventional and automation-assisted screening. Instead, primary HPV screening found 58% (95% confidence interval 19-109%) more cervical lesions than conventional screening. However, this was mainly due to overrepresentation of mild- and moderate-grade lesions and, thus, is likely to result in overtreatment since a great deal of these lesions would never progress to invasive cancer. Primary screening with an HPV DNA test alone caused substantial loss in specificity in comparison to cytological screening. With the use of cytology triage test, the specificity of HPV screening improved close to the level of conventional cytology. The specificity of primary HPV screening was also increased by increasing the test positivity cutoff from the level recommended for clinical use, but the increase was more modest than the one gained with the use of cytology triage. The performance of the cervical cancer screening programme varied widely between the screening laboratories, but the variation in overall programme effectiveness between respective populations was more marginal from the very beginning of the organised screening activity. Thus, conclusive interpretations on the quality or success of screening should not be based on performance parameters only. In the evaluation of cervical cancer screening the outcome should be selected as closely as possible to the true measure of programme effectiveness, which is the number of invasive cervical cancers and subsequent deaths prevented in the target population. The evaluation of benefits and adverse effects of each new suggested screening technology should be performed before the technology becomes an accepted routine in the existing screening programme. At best, the evaluation is performed randomised, within the population and screening programme in question, which makes the results directly applicable to routine use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Given the increasing cost of designing and building new highway pavements, reliability analysis has become vital to ensure that a given pavement performs as expected in the field. Recognizing the importance of failure analysis to safety, reliability, performance, and economy, back analysis has been employed in various engineering applications to evaluate the inherent uncertainties of the design and analysis. The probabilistic back analysis method formulated on Bayes' theorem and solved using the Markov chain Monte Carlo simulation method with a Metropolis-Hastings algorithm has proved to be highly efficient to address this issue. It is also quite flexible and is applicable to any type of prior information. In this paper, this method has been used to back-analyze the parameters that influence the pavement life and to consider the uncertainty of the mechanistic-empirical pavement design model. The load-induced pavement structural responses (e.g., stresses, strains, and deflections) used to predict the pavement life are estimated using the response surface methodology model developed based on the results of linear elastic analysis. The failure criteria adopted for the analysis were based on the factor of safety (FOS), and the study was carried out for different sample sizes and jumping distributions to estimate the most robust posterior statistics. From the posterior statistics of the case considered, it was observed that after approximately 150 million standard axle load repetitions, the mean values of the pavement properties decrease as expected, with a significant decrease in the values of the elastic moduli of the expected layers. An analysis of the posterior statistics indicated that the parameters that contribute significantly to the pavement failure were the moduli of the base and surface layer, which is consistent with the findings from other studies. After the back analysis, the base modulus parameters show a significant decrease of 15.8% and the surface layer modulus a decrease of 3.12% in the mean value. The usefulness of the back analysis methodology is further highlighted by estimating the design parameters for specified values of the factor of safety. The analysis revealed that for the pavement section considered, a reliability of 89% and 94% can be achieved by adopting FOS values of 1.5 and 2, respectively. The methodology proposed can therefore be effectively used to identify the parameters that are critical to pavement failure in the design of pavements for specified levels of reliability. DOI: 10.1061/(ASCE)TE.1943-5436.0000455. (C) 2013 American Society of Civil Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Strontium ions (Sr2+) are known to prevent osteoporosis and also encourage bone formation. Such twin requirements have motivated researchers to develop Sr-substituted biomaterials for orthopaedic applications. The present study demonstrates a new concept of developing Sr-substituted Mg-3(PO4)(2) - based biodegradable scaffolds. In particular, this work reports the fabrication, mechanical properties with an emphasis on strength reliability as well as in vitro degradation of highly biodegradable strontium-incorporated magnesium phosphate cements. These implantable scaffolds were fabricated using three-dimensional powder printing, followed by high temperature sintering and/or chemical conversion, a technique adaptable to develop patient-specific implants. A moderate combination of strength properties of 36.7 MPa (compression), 242 MPa (bending) and 10.7 MPa (tension) were measured. A reasonably modest Weibull modulus of up to 8.8 was recorded after uniaxial compression or diametral tensile tests on 3D printed scaffolds. A comparison among scaffolds with varying compositions or among sintered or chemically hardened scaffolds reveals that the strength reliability is not compromised in Sr-substituted scaffolds compared to baseline Mg-3(PO4)(2). The micro-computed tomography analysis reveals the presence of highly interconnected porous architecture in three-dimension with lognormal pore size distribution having median in the range of 17.74-26.29 mu m for the investigated scaffolds. The results of extensive in vitro ion release study revealed passive degradation with a reduced Mg2+ release and slow but sustained release of Sr2+ from strontium-substituted magnesium phosphate scaffolds. Taken together, the present study unequivocally illustrates that the newly designed Sr-substituted magnesium phosphate scaffolds with good strength reliability could be used for biomedical applications requiring consistent Sr2+-release, while the scaffold degrades in physiological medium. Statement of significance The study investigates the additive manufacturing of scaffolds based on different strontium-substituted magnesium phosphate bone cements by means of three-dimensional powder printing technique (3DPP). Magnesium phosphates were chosen due to their higher biodegradability compared to calcium phosphates, which is due to both a higher solubility as well as the absence of phase changes (to low soluble hydroxyapatite) in vivo. Since strontium ions are known to promote bone formation by stimulating osteoblast growth, we aimed to establish such a highly degradable magnesium phosphate ceramic with an enhanced bioactivity for new bone ingrowth. After post-processing, mechanical strengths of up to 36.7 MPa (compression), 24.2 MPa (bending) and 10.7 MPa (tension) could be achieved. Simultaneously, the failure reliability of those bioceramic implant materials, measured by Weibull modulus calculations, were in the range of 4.3-8.8. Passive dissolution studies in vitro proved an ion release of Mg2+ and PO43- as well as Sr2+, which is fundamental for in vivo degradation and a bone growth promoting effect. In our opinion, this work broadens the range of bioceramic bone replacement materials suitable for additive manufacturing processing. The high biodegradability of MPC ceramics together with the anticipated promoting effect on osseointegration opens up the way for a patient-specific treatment with the prospect of a fast and complete healing of bone fractures. (C) 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The working condition and atmosphere in a wooden fishing vessel are generally most injurious to the electrical systems. Therefore great care has to be taken in designing electrical systems for small c1afts. This paper deals with the difficult operating conditions and standardisation of electrical systems as applicable to small fishing vessels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this presentation, we report excellent electrical and optical characteristics of a dual gate photo thin film transistor (TFT) with bi-layer oxide channel, which was designed to provide virgin threshold voltage (V T) control, improve the negative bias illumination temperature stress (NBITS) reliability, and offer high photoconductive gain. In order to address the photo-sensitivity of phototransistor for the incoming light, top transparent InZnO (IZO) gate was employed, which enables the independent gate control of dual gate photo-TFT without having any degradation of its photosensitivity. Considering optimum initial V T and NBITS reliability for the device operation, the top gate bias was judiciously chosen. In addition, the speed and noise performance of the photo-TFT is competitive with silicon photo-transistors, and more importantly, its superiority lies in optical transparency. © 2011 IEEE.