403 resultados para Radiopharmaceutical 18F-FDG


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Functional imaging studies of addiction following protracted abstinence have not been systematically conducted to look at the associations between severity of use of different drugs and brain dysfunction. Findings from such studies may be relevant to implement specific interventions for treatment. The aim of this study was to examine the association between resting-state regional brain metabolism (measured with 18F-fluorodeoxyglucose Positron Emission Tomography (FDG-PET) and the severity of use of cocaine, heroin, alcohol, MDMA and cannabis in a sample of polysubstance users with prolonged abstinence from all drugs used. METHODS Our sample consisted of 49 polysubstance users enrolled in residential treatment. We conducted correlation analyses between estimates of use of cocaine, heroin, alcohol, MDMA and cannabis and brain metabolism (BM) (using Statistical Parametric Mapping voxel-based (VB) whole-brain analyses). In all correlation analyses conducted for each of the drugs we controlled for the co-abuse of the other drugs used. RESULTS The analysis showed significant negative correlations between severity of heroin, alcohol, MDMA and cannabis use and BM in the dorsolateral prefrontal cortex (DLPFC) and temporal cortex. Alcohol use was further associated with lower metabolism in frontal premotor cortex and putamen, and stimulants use with parietal cortex. CONCLUSIONS Duration of use of different drugs negatively correlated with overlapping regions in the DLPFC, whereas severity of cocaine, heroin and alcohol use selectively impact parietal, temporal, and frontal-premotor/basal ganglia regions respectively. The knowledge of these associations could be useful in the clinical practice since different brain alterations have been associated with different patterns of execution that may affect the rehabilitation of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte : Les patients souffrant d'un épisode dépressif sévère sont fréquemment traités par des inhibiteurs sélectifs de la recapture de la sérotonine (SSRI). Cependant, seulement 30-50% des patients répondront à ce type de traitement. Actuellement, il n'existe pas de marqueur biologique utilisable pour prédire la réponse à un traitement par SSRI. Un délai dans la mise en place d'une thérapie efficace peut avoir comme conséquences néfastes une augmentation du risque de suicide et une association avec un moins bon pronostic à long terme lors d'épisodes ultérieurs. Objectif : Par l'étude du métabolisme cérébral par tomographie par émission de positons (PET) au F-18-fluorodeoxyglucose (FDG), nous étudierons la présence de corrélations éventuelles entre la réponse clinique, qui généralement survient dans les 4 à 6 semaines après l'instauration du traitement antidépresseur, et une modification du métabolisme cérébral mesuré plus précocement, dans le but d'identifier les futurs répondeurs au traitement par SSRI. Méthodes : Cette étude longitudinale comprendra 20 patients unipolaires avec un épisode dépressif sévère au bénéfice d'un traitement par SSRI. Chacun des patients aura deux examens PET cérébraux au F-18-FDG. Le premier PET aura lieu juste avant le début du traitement aux SSRI et le second dans la 3ème semaine après début du traitement. La réponse clinique sera mesurée à 3 mois, et les répondeurs seront identifiés par une diminution significative des scores lors d'évaluation sur échelles de dépression. La recherche d'altérations métaboliques cérébrales sera faite en évaluant: (1) l'examen de base ou (2) l'examen PET précoce, à la recherche d'altérations spécifiques corrélées à une bonne réponse clinique, afin d'obtenir une valeur pronostique quant à la réponse au traitement. L'analyse de l'imagerie cérébrale utilisera la technique SPM (Statistical Parameter Mapping) impliquant un traitement numérique voxel par voxel des images PET. Résultats escomptés : Cette étude caractérisant les variations du métabolisme cérébral dans la phase précoce d'un traitement par SSRI vise à identifier des marqueurs métaboliques potentiels fournissant une valeur prédictive quant à la future efficacité du traitement SSRI introduit. Plus-value escomptée : L'identification d'un tel marqueur métabolique permettrait d'identifier rapidement les futurs répondeurs aux SSRI, et par conséquent d'éviter de proposer aux non-répondeurs la poursuite d'une médication, pendant plusieurs semaines, qui aurait peu de chance d'être efficace. Ainsi, une identification précoce des répondeurs aux SSRI pourrait permettre d'éviter des délais dans la mise en place d'une thérapie efficace et d'obtenir une amélioration du pronostic à plus long terme, avec une influence favorable sur les coûts de la santé.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El 18F-ML-10 és un radiofàrmac utilitzat com a traçador de cèl·lules apoptòtiques mitjançant la tècnica del PET (Positron Emission Tomography). En el present treball de recerca s’ha dut a terme la síntesi de dos precursors del 18F-ML-10, i del producte final no marcat isotòpicament, el ML-10. S’ha plantejat una síntesi convergent per l’obtenció del compost final 3, partint del malonat de di-tert-butil i l’1,5-pentandiol. Tant el precursor tosilat 1 com el mesilat 2 s’han sintetitzat en 3 etapes amb un 29% i un 36% de rendiment, respectivament. El compost 3, utilitzat com a referència en la síntesi del 18F-ML-10, s’ha sintetitzat en 2 etapes a partir del precursor 2 amb un rendiment total de la síntesi del 31%. El procés de radiomarcació s’està portant a terme a l’Institut d’Alta Tecnologia – Parc de Recerca Biomèdica de Barcelona (IAT–PRBB), on posteriorment es faran estudis neurològics i oncològics on el seguiment de processos apoptòtics és clau.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif : Les épanchements pleuraux sont fréquents chez les patients porteurs de cancer et déterminer s'ils sont de nature tumorale ou non relève d'une grande importance clinique, particulièrement pour le groupe des carcinomes pulmonaires NON à petites cellules (NSCLC). Le PET/CT s'est montré d'une grande utilité et est actuellement indiscutablement reconnu comme outils nécessaire dans la prise en charge et notamment la stadification et le suivi des cancers, et particulièrement des cancers pulmonaires. Sa capacité à pouvoir distinguer les épanchements pleuraux malins des épanchements pleuraux non tumoraux, « bénins » n'est pas précisément connue et n'a pas jusqu'à présent été investiguée de manière approfondie. Matériel et méthodes : Nous avons examiné la captation du FDG (indice SUVmax) des épanchements pleuraux de 50 PET/CT réalisés chez 47 patients (29 hommes, 18 femmes, 60±16 ans) avec épanchements pleuraux et cancer connu (24 NSCLC, 7 lymphomes, 5 cancer du sein, 4 GIST, 3 mésothéliomes, 2 cancer ORL, 2 tératomes malins, 1 carcinome colorectal, 1 carcinome oesophagien, 1 mélanome). Ces résultats ont été corrélés aux résultats des examens cytopathologiques réalisés après ponction de ces mêmes épanchements dans un intervalle médian de 21 jours (interquartile range -3 to 23). L'examen du liquide d'épanchement comportait la mesure du pH, la distribution relative des différents éléments cellulaires (macrophages, neutrophils, éosinophiles, basophiles, lymphocytes, plasmocytes), la numération cellulaire et bien entendu présence de cellules tumorales. Résultats : Parmis les épanchements, 17 étaient malins (34%) (6 NSCLC, 5 lymphomes, 2 cancers mammaires, 2 mésothéliomes, 2 tératomes malins). Les SUV étaient plus élevés dans les épanchements malins que dans les épanchements bénins [3.7 (95%IC 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], avec une corrélation entre les épanchements malins et le SUV (coefficient de Spearman ρ = 0.50, p = 0.001). Il n'a pas été observé de corrélation entre aucun des autres paramètres cyptopathologiques ou radiologiques analysé (aire sous la courbe ROC 0.83 ± 0.06). En utilisant un seuil du SUV de 2.2-mg/l, 12 examens PET/CT étaient interprétés comme positifs and 38 comme négatifs avec une sensibilité et une spécificité, valeur prédictive positive et négative de 53%, 91%, 75% and 79% respectivement. Concernant le groupe des NSCLC seulement (n = 24), aire sous la courbe ROC était de 0.95 ± 0.04. Sept examens étaient considérés comme positifs et 17 comme négatifs avec une sensibilité, une spécificité, valeur prédictive positive et négative de 83%, 89%, 71 et 94% respectivement. Conclusion : Le PET/CT peut aider à différencier la nature bénigne ou maligne des épanchements avec une haute spécificité chez les patients avec tumeur connue, en particulier dans un contexte de carcinome NON à petites cellules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We diagnosed a non-small cell lung carcinoma in a 49-year-old female patient with the histopathological diagnosis of stage IIIB mixed bronchioloalveolar and papillary adenocarcinoma with extensive micropapillary feature, which was not visualized on the preoperative multimodality imaging with positron emission tomography (PET) and computed tomography (CT). The micropapillary component characterized by a unique growth pattern with particular morphological features can be observed in all subtypes of lung adenocarcinoma. Micropapillary component is increasingly recognized as a distinct entity associated with higher aggressiveness. Even the most modern multimodality PET/CT imaging technology may fail to adequately visualize this important component with highly relevant prognostic implications. Thus, the pathologist needs to consciously look for a micropapillary component in the surgical specimen or in preoperative biopsies or cytology. This may have potential future treatment implications, as adjuvant or neoadjuvant chemotherapy may be of relevance, even in the early stages of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In the radiopharmaceutical therapy approach to the fight against cancer, in particular when it comes to translating laboratory results to the clinical setting, modeling has served as an invaluable tool for guidance and for understanding the processes operating at the cellular level and how these relate to macroscopic observables. Tumor control probability (TCP) is the dosimetric end point quantity of choice which relates to experimental and clinical data: it requires knowledge of individual cellular absorbed doses since it depends on the assessment of the treatment's ability to kill each and every cell. Macroscopic tumors, seen in both clinical and experimental studies, contain too many cells to be modeled individually in Monte Carlo simulation; yet, in particular for low ratios of decays to cells, a cell-based model that does not smooth away statistical considerations associated with low activity is a necessity. The authors present here an adaptation of the simple sphere-based model from which cellular level dosimetry for macroscopic tumors and their end point quantities, such as TCP, may be extrapolated more reliably. METHODS: Ten homogenous spheres representing tumors of different sizes were constructed in GEANT4. The radionuclide 131I was randomly allowed to decay for each model size and for seven different ratios of number of decays to number of cells, N(r): 1000, 500, 200, 100, 50, 20, and 10 decays per cell. The deposited energy was collected in radial bins and divided by the bin mass to obtain the average bin absorbed dose. To simulate a cellular model, the number of cells present in each bin was calculated and an absorbed dose attributed to each cell equal to the bin average absorbed dose with a randomly determined adjustment based on a Gaussian probability distribution with a width equal to the statistical uncertainty consistent with the ratio of decays to cells, i.e., equal to Nr-1/2. From dose volume histograms the surviving fraction of cells, equivalent uniform dose (EUD), and TCP for the different scenarios were calculated. Comparably sized spherical models containing individual spherical cells (15 microm diameter) in hexagonal lattices were constructed, and Monte Carlo simulations were executed for all the same previous scenarios. The dosimetric quantities were calculated and compared to the adjusted simple sphere model results. The model was then applied to the Bortezomib-induced enzyme-targeted radiotherapy (BETR) strategy of targeting Epstein-Barr virus (EBV)-expressing cancers. RESULTS: The TCP values were comparable to within 2% between the adjusted simple sphere and full cellular models. Additionally, models were generated for a nonuniform distribution of activity, and results were compared between the adjusted spherical and cellular models with similar comparability. The TCP values from the experimental macroscopic tumor results were consistent with the experimental observations for BETR-treated 1 g EBV-expressing lymphoma tumors in mice. CONCLUSIONS: The adjusted spherical model presented here provides more accurate TCP values than simple spheres, on par with full cellular Monte Carlo simulations while maintaining the simplicity of the simple sphere model. This model provides a basis for complementing and understanding laboratory and clinical results pertaining to radiopharmaceutical therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Contribution of 3-phase 18F-fluorocholine PET/CT in suspected prostate cancer recurrence at early rise of PSA. PATIENTS, METHODS: Retrospective analysis was performed in 47 patients after initial treatment with radiotherapy (n=30) or surgery (n=17). Following CT, 10 minutes list-mode PET acquisition was done over the prostate bed after injection of 300 MBq of 18F-fluorocholine. Three timeframes of 3 minutes each were reconstructed for analysis. All patients underwent subsequent whole body PET/CT. Delayed pelvic PET/CT was obtained in 36 patients. PET/CT was interpreted visually by two observers and SUVmax determined for suspicious lesions. Biopsies were obtained from 13 patients. RESULTS: Biopsies confirmed the presence of cancer in 11 of 13 patients with positive PET for a total of 15 local recurrences in which average SUVmax increased during 14 minutes post injection and marginally decreased in delayed scanning. Conversely inguinal lymph nodes with mild to moderate metabolic activity on PET showed a clearly different pattern with decreasing SUVmax on dynamic images. Three-phase PET/CT contributed to the diagnostic assessment of 10 of 47 patients with biological evidence of recurrence of cancer. It notably allowed the discrimination of confounding blood pool or urinary activity from suspicious hyperactivities. PET/CT was positive in all patients with PSA>or=2 ng/ml (n=34) and in 4/13 patients presenting PSA values<2 ng/ml. CONCLUSION: 18F-fluorocholine 3-phase PET/CT showed a progressively increasing SUVmax in biopsy confirmed cancer lesions up to 14 minutes post injection while decreasing in inguinal lymph nodes interpreted as benign. Furthermore, it was very useful in differentiating local recurrences from confounding blood pool and urinary activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 37-year-old man suffering from insidious visual agnosia and spastic paraparesis due to a PSEN1 mutation. His mother was diagnosed with Alzheimer disease after a biopsy. He was assessed by multimodal neuroimaging, including new in vivo positron emission tomography amyloid imaging (F-AV45). His data were compared with those from healthy participants and patients with sporadic predemential Alzheimer disease. He exhibited posterior cortical thickness reduction, posterior hypometabolism, and increased amyloid ligand uptake in the posterior cortex and the striatum. We show that F-AV45 positron emission tomography allows visualization of the unusual pattern of amyloid deposits that co-localize with cortical atrophy in this genetic form of Alzheimer disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is, aside skin cancer, the most common malignancy occurring after solid organ transplant in adults. Fluorodeoxyglucose (FDG) positron emission tomography (PET) has proved useful in the management of lymphomas. METHODS: We report our experience with the use of FDG-PET inline with computed tomography (CT) scanning in the management of four transplant recipients with histologically confirmed PTLD, including three monomorphic PTLDs and one polymorphic PTLD. RESULTS: FDG-PET/CT scan at diagnosis showed increased FDG uptake in all examined PTLD lesions, and the disease was upstaged on the basis of FDG-PET/CT scan results over conventional CT scanning in one patient. At the end of treatment, PET/CT scans no longer demonstrated FDG uptake in the original PTLD lesions in all patients. Complete remission of disease persisted for at least 1 year after diagnosis in all. CONCLUSIONS: Our results strongly support that FDG-PET scanning is highly specific for diagnosis and follow-up of PTLD. The clinical relevance of including FDG-PET/CT scanning in the management of PTLD should be evaluated in a larger prospective cohort study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: 5-fluoro-2'-deoxyuridine (FdUrd) depletes the endogenous 5'-deoxythymidine triphosphate (dTTP) pool. We hypothesized whether uptake of exogenous dThd analogues could be favoured through a feedback enhanced salvage pathway and studied the FdUrd effect on cellular uptake of 3'-deoxy-3'-18F-fluorothymidine (18F-FLT) and 5-125I-iodo-2'-deoxyuridine (125I-IdUrd) in different cancer cell lines in parallel. Methods: Cell uptake of 18F-FLT and 125I-IdUrd was studied in 2 human breast, 2 colon cancer and 2 glioblastoma lines. Cells were incubated with/without 1 µmol/l FdUrd for 1 h and, after washing, with 1.2 MBq 18F-FLT or 125I-IdUrd for 0.3 to 2 h. Cell bound 18F-FLT and 125I-IdUrd was counted and expressed in % incubated activity (%IA). Kinetics of 18F-FLT cell uptake and release were studied with/without FdUrd modulation. 2'-3H-methyl-fluorothymidine (2'-3H-FLT) uptake with/without FdUrd pretreatment was tested on U87 spheroids and monolayer cells. Results: Basal uptake at 2 h of 18F-FLT and 125I-IdUrd was in the range of 0.8-1.0 and 0.4-0.6 Bq/cell, respectively. FdUrd pretreatment enhanced 18F-FLT and 125I-IdUrd uptake 1.2-2.1 and 1.7-4.4 fold, respectively, while co-incubation with excess thymidine abrogated all 18F-FLT uptake. FdUrd enhanced 18F-FLT cellular inflow in 2 breast cancer lines by factors of 1.8 and 1.6, respectively, while outflow persisted at a slightly lower rate. 2'-3H-FLT basal uptake was very low while uptake increase after FdUrd was similar in U87 monolayer cells and spheroids. Conclusions: Basal uptake of 18F-FLT was frequently higher than that of 125I-IdUrd but FdUrd induced uptake enhancement was stronger for 125I-IdUrd in five of six cell lines. 18F-FLT outflow from cells might be an explanation for the observed difference with 125I-IdUrd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented evaluates the statistical characteristics of regional bias and expected error in reconstructions of real positron emission tomography (PET) data of human brain fluoro-deoxiglucose (FDG) studies carried out by the maximum likelihood estimator (MLE) method with a robust stopping rule, and compares them with the results of filtered backprojection (FBP) reconstructions and with the method of sieves. The task of evaluating radioisotope uptake in regions-of-interest (ROIs) is investigated. An assessment of bias and variance in uptake measurements is carried out with simulated data. Then, by using three different transition matrices with different degrees of accuracy and a components of variance model for statistical analysis, it is shown that the characteristics obtained from real human FDG brain data are consistent with the results of the simulation studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.