991 resultados para Radiology, nuclear medicine
Resumo:
Hemochromatosis can be classified as (a) primary, when it originates from a genetic disturbance that promotes the increase of iron absorption, or (b) secondary, when it relates to chronic diseases or to multiple transfusions. The distribution of iron accumulation differs between these two forms; therefore, they can be distinguished by using imaging methods in the majority of cases. Magnetic resonance (MR) imaging is the most sensitive and specific imaging modality in the diagnosis of hemochromatosis. The susceptibility effect caused by the accumulation of iron leads to signal loss in the affected tissues, particularly with the T2*-weighted sequences, which makes the diagnosis of iron overload possible. By using MR imaging techniques, it is possible to estimate the hepatic iron concentration in a noninvasive way, thereby avoiding repeated biopsies. Hemochromatosis can lead to complications, such as a higher frequency of neoplasia, particularly the development of hepatocellular carcinoma. Other neoplasms, such as colorectal tumors, are also associated. Complications related to the treatment of chronic anemia include the appearance of peliosis hepatis and tumors, which can regress after the suspension of treatment with drugs. Knowledge of the disease and of the patterns of iron deposition in patients with iron overload enables not only diagnosis, but also treatment, follow-up, and the detection of possible complications by using imaging methods. (C) RSNA, 2009 . radiographics.rsna.org
Resumo:
OBJECTIVE. Toxic leukoencephalopathy may present acutely or subacutely with symmetrically reduced diffusion in the periventricular and supraventricular white matter, hereafter referred to as periventricular white matter. This entity may reverse both on imaging and clinically. However, a gathering together of the heterogeneous causes of this disorder as seen on MRI with diffusion-weighted imaging (DWI) and an analysis of their likelihood to reverse has not yet been performed. Our goals were to gather causes of acute or subacute toxic leukoencephalopathy that can present with reduced diffusion of periventricular white matter in order to promote recognition of this entity, to evaluate whether DWI with apparent diffusion coefficient (ADC) values can predict the extent of chronic FLAIR abnormality ( imaging reversibility), and to evaluate whether DWI can predict the clinical outcome ( clinical reversibility). MATERIALS AND METHODS. Two neuroradiologists retrospectively reviewed the MRI examinations of 39 patients with acute symptoms and reduced diffusion of periventricular white matter. The reviewers then scored the extent of abnormality on DWI and FLAIR. ADC ratios of affected white matter versus the unaffected periventricular white matter were obtained. Each patient`s clinical records were reviewed to determine the cause and clinical outcome. Histology findings were available in three patients. Correlations were calculated between the initial MRI markers and both the clinical course and the follow-up extent on FLAIR using Spearman`s correlation coefficient. RESULTS. Of the initial 39 patients, seven were excluded because of a nontoxic cause (hypoxic-ischemic encephalopathy [HIE] or congenital genetic disorders) or because of technical errors. In the remaining 32 patients, no correlation was noted between any of the initial MRI markers (percentage of ADC reduction, DWI extent, or FLAIR extent) with the clinical outcome. Three patients had histologic correlation. However, moderate correlation was seen between the extent of abnormality on initial FLAIR and the extent on follow-up FLAIR (r = 0.441, p = 0.047). Of the 13 patients who underwent repeat MRI at 21 days or longer, the reduced diffusion resolved in all but one. Significant differences were noted between ADC values in affected white matter versus unaffected periventricular white matter on initial (p < 0.0001) but not on follow-up MRI (p = 0.13), and in affected white matter on initial versus follow-up (p = 0.0014) in those individuals who underwent repeat imaging on the same magnet (n = 9), confirming resolution of the DWI abnormalities. CONCLUSION. Acute toxic leukoencephalopathy with reduced diffusion may be clinically reversible and radiologically reversible on DWI, and may also be reversible, but to a lesser degree, on FLAIR MRI. None of the imaging markers measured in this study appears to correlate with clinical outcome, which underscores the necessity for prompt recognition of this entity. Alerting the clinician to this potentially reversible syndrome can facilitate treatment and removal of the offending agent in the early stages.
Resumo:
OBJECTIVE. The purposes of this study were to use the myocardial delayed enhancement technique of cardiac MRI to investigate the frequency of unrecognized myocardial infarction (MI) in patients with end-stage renal disease, to compare the findings with those of ECG and SPECT, and to examine factors that may influence the utility of these methods in the detection of MI. SUBJECTS AND METHODS. We prospectively performed cardiac MRI, ECG, and SPECT to detect unrecognized MI in 72 patients with end-stage renal disease at high risk of coronary artery disease but without a clinical history of MI. RESULTS. Fifty-six patients (78%) were men ( mean age, 56.2 +/- 9.4 years) and 16 (22%) were women ( mean age, 55.8 +/- 11.4). The mean left ventricular mass index was 103.4 +/- 27.3 g/m(2), and the mean ejection fraction was 60.6% +/- 15.5%. Myocardial delayed enhancement imaging depicted unrecognized MI in 18 patients (25%). ECG findings were abnormal in five patients (7%), and SPECT findings were abnormal in 19 patients (26%). ECG findings were false-negative in 14 cases and false-positive in one case. The accuracy, sensitivity, and specificity of ECG were 79.2%, 22.2%, and 98.1% (p = 0.002). SPECT findings were false-negative in six cases and false-positive in seven cases. The accuracy, sensitivity, and specificity of SPECT were 81.9%, 66.7%, and 87.0% ( not significant). During a period of 4.9-77.9 months, 19 cardiac deaths were documented, but no statistical significance was found in survival analysis. CONCLUSION. Cardiac MRI with myocardial delayed enhancement can depict unrecognized MI in patients with end-stage renal disease. ECG and SPECT had low sensitivity in detection of MI. Infarct size and left ventricular mass can influence the utility of these methods in the detection of MI.
Resumo:
Purpose: To evaluate the risk of geographic miss associated with the classic four-field ""box"" irradiation technique and to define the variables that predict this risk. Materials and Methods: The study population consisted of 80 patients with uterine cervix cancer seen between 2001 and 2006. Median age was 55 years (23-82 years), and 72 (90%) presented with squamous cell carcinoma. Most patients (68.7%) presented with locally advanced disease (IIb or more). Magnetic resonance imaging findings from before treatment were compared with findings from simulation of the conventional four-field ""box"" technique done with rectal contrast. Study variables included tumor volume; involvement of vagina, parametrium, bladder, or rectum; posterior displacement of the anterior rectal wall; and tumor anteroposterior diameter (APD). Margins were considered adequate when the target volume (primary tumor extension, whole uterine body, and parametrium) was included within the field limits and were at least 1 cm in width. Results: Field limits were inadequate in 45 (56%) patients: 29 (36%) patients at the anterior and 28 (35%) at the posterior border of the lateral fields. Of these, 12 patients had both anterior and posterior miss, and this risk was observed in all stages of the disease (p = 0.076). Posterior displacement of the anterior rectal wall beyond S2-S3 was significantly correlated with the risk of geographic miss (p = 0.043). Larger tumors (APD 6 cm or above and volume above 50 cm(3)) were also significantly correlated with this risk (p = 0.004 and p = 0.046, respectively). Conclusions: Posterior displacement of the anterior rectal wall, tumor APD, and volume can be used as guidance in evaluating the risk of geographic miss. (C) 2009 Elsevier Inc.
Resumo:
(99m)Tc-MIBI gated myocardial scintigraphy (GMS) evaluates myocyte integrity and perfusion, left ventricular (LV) dyssynchrony and function. Cardiac resynchronization therapy (CRT) may improve the clinical symptoms of heart failure (HF), but its benefits for LV function are less pronounced. We assessed whether changes in myocardial (99m)Tc-MIBI uptake after CRT are related to improvement in clinical symptoms, LV synchrony and performance, and whether GMS adds information for patient selection for CRT. A group of 30 patients with severe HF were prospectively studied before and 3 months after CRT. Variables analysed were HF functional class, QRS duration, LV ejection fraction (LVEF) by echocardiography, myocardial (99m)Tc-MIBI uptake, LV end-diastolic volume (EDV) and end-systolic volume (ESV), phase analysis LV dyssynchrony indices, and regional motion by GMS. After CRT, patients were divided into two groups according to improvement in LVEF: group 1 (12 patients) with increase in LVEF of 5 or more points, and group 2 (18 patients) without a significant increase. After CRT, both groups showed a significant improvement in HF functional class, reduced QRS width and increased septal wall (99m)Tc-MIBI uptake. Only group 1 showed favourable changes in EDV, ESV, LV dyssynchrony indices, and regional motion. Before CRT, EDV, and ESV were lower in group 1 than in group 2. Anterior and inferior wall (99m)Tc-MIBI uptakes were higher in group 1 than in group 2 (p < 0.05). EDV was the only independent predictor of an increase in LVEF (p=0.01). The optimal EDV cut-off point was 315 ml (sensitivity 89%, specificity 94%). The evaluation of EDV by GMS added information on patient selection for CRT. After CRT, LVEF increase occurred in hearts less dilated and with more normal (99m)Tc-MIBI uptake.
The selection of intended actions and the observation of others' actions: A time-resolved fMRI study
Resumo:
Whenever we plan, imagine, or observe an action, the motor systems that would be involved in preparing and executing that action are similarly engaged. The way in which such common motor activation is formed, however, is likely to differ depending on whether it arises from our own intentional selection of action or from the observation of another's action. In this study, we use time-resolved event-related functional MRI to tease apart neural processes specifically related to the processing of observed actions, the selection of our own intended actions, the preparation for movement, and motor response execution. Participants observed a finger gesture movement or a cue indicating they should select their own finger gesture to perform, followed by a 5-s delay period; participants then performed the observed or self-selected action. During the preparation and readiness for action, prior to initiation, we found activation in a common network of higher motor areas, including dorsal and ventral premotor areas and the pre-supplementary motor area (pre-SMA); the more caudal SMA showed greater activation during movement execution. Importantly, the route to this common motor activation differed depending on whether participants freely selected the actions to perform or whether they observed the actions performed by another person. Observation of action specifically involved activation of inferior and superior parietal regions, reflecting involvement of the dorsal visual pathway in visuomotor processing required for planning the action. In contrast, the selection of action specifically involved the dorsal lateral prefrontal and anterior cingulate cortex, reflecting the role of these prefrontal areas in attentional selection and guiding the selection of responses. (c) 2005 Elsevier Inc. All rights reserved.
Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64
Resumo:
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.
Resumo:
OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.
Resumo:
Background and purpose: To evaluate biochemical control and treatment related toxicity of patients with localized adenocarcinoma of the prostate treated with high dose-rate brachytherapy (HDRB) combined with conventional 2D or 3D-conformal external beam irradiation (EBI). Material and methods: Four-hundred and three patients treated between December 2000 and March 2004. HDRB was delivered with three fractions of 5.5-7 Gy with a single implant, followed by 45 Gy delivered with 2D or 3D conformal EBI. Results: The median follow-up was 48.4 months. Biochemical failure (BF) occurred in 9.6% according to both ASTRO and Phoenix consensus criteria. Mean time to relapse was 13 and 26 months, respectively. The 5-year BF free survival using the ASTRO criteria was 94.3%, 86.9% and 86.6% for the low, intermediate and high risk groups, respectively; using Phoenix criteria, 92.4%, 88.0% and 85.3%, respectively. The only predictive factor of BF in the multivariate analysis by both ASTRO and Phoenix criteria was the presence of prostate nodules detected by digital palpation, and patients younger than 60 years presented a higher chance of failure using Phoenix criteria only. Conclusions: Treatment scheme is feasible and safe with good efficacy. (C) 2011 Elsevier Ireland Ltd All rights reserved. Radiotherapy and Oncology 98 (2011) 169-174
Resumo:
Purpose: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). Materials and Methods: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multi-center study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (>50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (<90 degrees), moderate (90 degrees-180 degrees), or severe (>180 degrees) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. Results: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). Conclusion: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.
Resumo:
Direct carotid-cavernous fistula (CCF) is a direct communication between the internal carotid artery (ICA) and the cavernous sinus. Some patients treated with detachable balloons develop pseudoaneurysms or present with a true aneurysm recanalization in the cavernous ICA with poorly known long-term radiological and clinical progression. The objective of the present study was to evaluate the long-term clinical and radiological progression of patients treated with detachable balloons. The present study evaluated 13 patients previously treated for direct CCF by an endovascular approach. The follow-up period ranged between 19 and 128 months. Ophthalmological evaluation demonstrated alterations in eight patients (61.5%). All of these alterations were already present from the moment of the treatment and displayed no signs of progression. Cranial magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) were performed in all patients, and 11 pseudoaneurysms were demonstrated in ten of the 11 patients in whom ICA patency had been preserved. Five patients were submitted for cerebral digital subtraction angiography (DSA) to characterize the pseudoaneurysms previously observed on MRA studies, with no significant differences in morphology, size, aneurismal neck, and number of lesions. Endovascular treatment of direct CCF with detachable balloons has been shown to be a long-term effective and stable therapeutic method. The authors found asymptomatic pseudoaneurysms in 91% of cases where the ICA patency was preserved. MRI and MRA demonstrated an accuracy similar to that of DSA in the diagnosis of pseudoaneurysms of cavernous ICA.
Resumo:
CTX is a rare lipid-storage disease. Novel MRS findings from 3 patients, using a short TE, were the presence of lipid peaks at 0.9 and 1.3 ppm in the depth of the cerebellar hemisphere; this might represent an additional marker of disease that is CNS-specific and noninvasive. A decrease in NAA concentration was also detected and attributed to neuroaxonal damage. One patient presented an increase in mlns concentration, pointing to gliosis and astrocytic proliferation.
Resumo:
PURPOSE: To report a series of patients with symptomatic internal carotid artery (ICA) occlusion treated with angioplasty and stents. MATERIALS AND METHODS: From a consecutive series of 50 patients experiencing neurologic ischemic symptoms and shown by conventional ultrasonography (US) to have a total ICA occlusion, 16 patients (ages 45-79 years; mean, 63 y; 10 men) were selected between August 2006 to September 2008 to be treated with angioplasty based on discovery of an open ICA distal to the occlusion through contrast-enhanced echo Doppler imaging and/or multislice contrast computed tomography (CT). Angioplasty and stent placement were performed under cerebral protection. Follow-up duplex imaging was performed at 14 days and 3 months and every 6 months thereafter and CT follow-up was performed at 2-9 months; the mean follow-up period was 9.9 months. RESULTS: Lesion crossing and stent placement was successful in 13 of 16 patients. There were no deaths, conversions, cardiac complications, or major strokes. One patient had a transient mild hemiparesis in the upper limb, with total recovery in 3 months. At follow-up, all 13 patients with a good initial result remained with patent arterial lumens and resolution of neurologic ischemic symptoms. After 2-9 months, ICAs with a ""string sign"" had calibers close or equal to those of normal arteries. CONCLUSIONS: Angioplasty with stent placement is an effective treatment with a low morbidity rate for selected patients who continue to experience neurologic ischemic symptoms despite US findings of total occlusion of the ICA.
Resumo:
Purpose: To define the role of magnetization transfer imaging (MTI) in detecting subclinical central nervous system (CNS) lesions in primary antiphospholipid syndrome (PAPS). Materials and Methods: Ten non-CNS PAPS patients were compared to 10 CNS PAPS patients and 10 age- and sex-matched controls. All PAPS patients met Sapporo criteria. All Subjects underwent conventional MRI and complementary MTI analysis to compose histograms. CNS viability was determined according to the magnetization transfer ratio (MTR) by mean pixel intensity (MPI) and the mean peak height (MPH). Volumetric cerebral measurements were assessed by brain parenchyma factor (BPF) and total/cerebral volume. Results: MTR histograms analysis revealed that MPI was significantly different among groups (P < 0.0001). Non-CNS PAPS had a higher MPI than CNS PAPS, (30.5 +/- 1.01 vs. 25.1 +/- 3.17 percent unit (pu); P < 0.05) although lower than controls (30.5 +/- 1.01 vs. 31.20 < 0.50 pu; P < 0.05). MPH in non-CNS PAPS (5.57 +/- 0.20% (1/pu)} was similar to controls (5.63 +/- 0.20% (1/pu), P > 0.05) and higher than CNS PAPS (4.71 +/- 0.30% (1/pu), P < 0.05). A higher peak location (PL) was also observed in the CNS PAPS group in comparison with the other groups (P < 0.0001). In addition, a lower BPF was found in non-CNS PAPS compared to controls (0.80 +/- 0.03 vs. 0.84 +/- 0.02 units; P < 0.05) but similar to CNS PAPS (0.80 +/- 0.03 vs. 0.79 +/- 0.05 units; P > 0.05). Conclusion: Our findings suggest that non-CNS PAPS patients have subclinical cerebral damage. The long-term-clinical relevance of MTI analysis in these patients needs to be defined by prospective studies.
Resumo:
As nuclear magnetic resonance imaging and spectroscopy move inexorably toward higher field-strength magnets in search of improved signal-to-noise ratio, spectral resolution, and spatial resolution, the way in which radiofrequency (RF) probes are designed changes. At higher frequencies, resonant cavities become the favored RF ''coil'' type and may be built using streamline elements to reduce the inductance of the system. In modeling such systems, the quasi-static approach of assuming that current flows evenly in all conductor cross sections and that adjacent conductors do not affect each other becomes less reasonable. The proximity of RF conductors in resonators typically causes RF eddy currents to flow, whereby the current density in each rung is altered by the RF fields generated by nearby conductors. The proper understanding and prediction of how resonators will perform require a model of the current densities flowing in conducting sections, including all RF eddy current effects. Very few models of this type have been presented in the literature. This article presents an overview of one such model and of how it may be applied to a variety of resonators, both shielded and unshielded, circular, and elliptical, in cross section. Results are presented from a shielded head coil operating at 2 tesla. (C) 1997 John Wiley & Sons, Inc.