868 resultados para Quality control -- Management
Resumo:
The Brazilian network for genotyping is composed of 21 laboratories that perform and analyze genotyping tests for all HIV-infected patients within the public system, performing approximately 25,000 tests per year. We assessed the interlaboratory and intralaboratory reproducibility of genotyping systems by creating and implementing a local external quality control evaluation. Plasma samples from HIV-1-infected individuals (with low and intermediate viral loads) or RNA viral constructs with specific mutations were used. This evaluation included analyses of sensitivity and specificity of the tests based on qualitative and quantitative criteria, which scored laboratory performance on a 100-point system. Five evaluations were performed from 2003 to 2008, with 64% of laboratories scoring over 80 points in 2003, 81% doing so in 2005, 56% in 2006, 91% in 2007, and 90% in 2008 (Kruskal-Wallis, p = 0.003). Increased performance was aided by retraining laboratories that had specific deficiencies. The results emphasize the importance of investing in laboratory training and interpretation of DNA sequencing results, especially in developing countries where public (or scarce) resources are used to manage the AIDS epidemic.
Resumo:
The development of an electroanalytical method for simultaneous determination of copper and lead ions in sugar cane spirit (cachaça) using carbon paste electrode modified with ascorbic acid and carbon nanotubes (CPE-AaCNT) is described. Squarewave voltammetry (SWV) with anodic stripping was employed, and this technique was optimized with respect to the following parameters: frequency (50 Hz), amplitude (100 mV) and scan increment (9 mV). The analytical curves were linear in the range from 0.0900 to 7.00 mg L- 1 for lead and copper. The limits of detection were 48.5 and 23.9 µg L- 1 for lead and copper, respectively. The developed method was applied to the simultaneous determination of copper and lead in five commercial samples of sugar cane spirit. The results were in good agreement with those obtained by F AAS/GF AAS (flame atomic absorption spectrometry/graphite furnace atomic absorption spectrometry) and showed that CPE-AaCNT can be successfully employed in the simultaneous determination of these metals in real sugar cane spirit samples.
Resumo:
The Gaia space mission is a major project for the European astronomical community. As challenging as it is, the processing and analysis of the huge data-flow incoming from Gaia is the subject of thorough study and preparatory work by the DPAC (Data Processing and Analysis Consortium), in charge of all aspects of the Gaia data reduction. This PhD Thesis was carried out in the framework of the DPAC, within the team based in Bologna. The task of the Bologna team is to define the calibration model and to build a grid of spectro-photometric standard stars (SPSS) suitable for the absolute flux calibration of the Gaia G-band photometry and the BP/RP spectrophotometry. Such a flux calibration can be performed by repeatedly observing each SPSS during the life-time of the Gaia mission and by comparing the observed Gaia spectra to the spectra obtained by our ground-based observations. Due to both the different observing sites involved and the huge amount of frames expected (≃100000), it is essential to maintain the maximum homogeneity in data quality, acquisition and treatment, and a particular care has to be used to test the capabilities of each telescope/instrument combination (through the “instrument familiarization plan”), to devise methods to keep under control, and eventually to correct for, the typical instrumental effects that can affect the high precision required for the Gaia SPSS grid (a few % with respect to Vega). I contributed to the ground-based survey of Gaia SPSS in many respects: with the observations, the instrument familiarization plan, the data reduction and analysis activities (both photometry and spectroscopy), and to the maintenance of the data archives. However, the field I was personally responsible for was photometry and in particular relative photometry for the production of short-term light curves. In this context I defined and tested a semi-automated pipeline which allows for the pre-reduction of imaging SPSS data and the production of aperture photometry catalogues ready to be used for further analysis. A series of semi-automated quality control criteria are included in the pipeline at various levels, from pre-reduction, to aperture photometry, to light curves production and analysis.
Resumo:
In the last decade the near-surface mounted (NSM) strengthening technique using carbon fibre reinforced polymers (CFRP) has been increasingly used to improve the load carrying capacity of concrete members. Compared to externally bonded reinforcement (EBR), the NSM system presents considerable advantages. This technique consists in the insertion of carbon fibre reinforced polymer laminate strips into pre-cut slits opened in the concrete cover of the elements to be strengthened. CFRP reinforcement is bonded to concrete with an appropriate groove filler, typically epoxy adhesive or cement grout. Up to now, research efforts have been mainly focused on several structural aspects, such as: bond behaviour, flexural and/or shear strengthening effectiveness, and energy dissipation capacity of beam-column joints. In such research works, as well as in field applications, the most widespread adhesives that are used to bond reinforcements to concrete are epoxy resins. It is largely accepted that the performance of the whole application of NSM systems strongly depends on the mechanical properties of the epoxy resins, for which proper curing conditions must be assured. Therefore, the existence of non-destructive methods that allow monitoring the curing process of epoxy resins in the NSM CFRP system is desirable, in view of obtaining continuous information that can provide indication in regard to the effectiveness of curing and the expectable bond behaviour of CFRP/adhesive/concrete systems. The experimental research was developed at the Laboratory of the Structural Division of the Civil Engineering Department of the University of Minho in Guimar\~aes, Portugal (LEST). The main objective was to develop and propose a new method for continuous quality control of the curing of epoxy resins applied in NSM CFRP strengthening systems. This objective is pursued through the adaptation of an existing technique, termed EMM-ARM (Elasticity Modulus Monitoring through Ambient Response Method) that has been developed for monitoring the early stiffness evolution of cement-based materials. The experimental program was composed of two parts: (i) direct pull-out tests on concrete specimens strengthened with NSM CFRP laminate strips were conducted to assess the evolution of bond behaviour between CFRP and concrete since early ages; and, (ii) EMM-ARM tests were carried out for monitoring the progressive stiffness development of the structural adhesive used in CFRP applications. In order to verify the capability of the proposed method for evaluating the elastic modulus of the epoxy, static E-Modulus was determined through tension tests. The results of the two series of tests were then combined and compared to evaluate the possibility of implementation of a new method for the continuous monitoring and quality control of NSM CFRP applications.
Resumo:
Virgin olive oil(VOO) is a product characterized by high economic and nutritional values, because of its superior sensory characteristics and minor compounds (phenols and tocopherols) contents. Since the original quality of VOO may change during its storage, this study aimed to investigate the influence of different storage and shipment conditions on the quality of VOO, by studying different solutions such as filtration, dark storage and shipment inside insulated containers to protect it. Different analytical techniques were used to follow-up the quality changes during virgin olive oil storage and simulated shipments, in terms of basic quality parameters, sensory analysis and evaluation of minor components (phenolic compounds, diglycerides, volatile compounds). Four main research streams were presented in this PhD thesis: The results obtained from the first experimental section revealed that the application of filtration and/or clarification can decrease the unavoidable quality loss of the oil samples during storage, in comparison with unfiltered oil samples. The second section indicated that the virgin olive oil freshness, evaluated by diglycerides content, was mainly affected by the storage time and temperature. The third section revealed that fluctuation in temperature during storage may adversely affect the virgin olive oil quality, in terms of hydrolytic rancidity and oxidation quality. The fourth section showed that virgin olive oil shipped inside insulated containers showed lower hydrolytic and oxidation degradation than those without insulation cover. Overall, this PhD thesis highlighted that application of adequate treatment, such as filtration or clarification, in addition to a good protection against other external variables, such as temperature and light, will improve the stability of virgin olive oil during storage.
Resumo:
For virtually all hospitals, utilization rates are a critical managerial indicator of efficiency and are determined in part by turnover time. Turnover time is defined as the time elapsed between surgeries, during which the operating room is cleaned and preparedfor the next surgery. Lengthier turnover times result in lower utilization rates, thereby hindering hospitals’ ability to maximize the numbers of patients that can be attended to. In this thesis, we analyze operating room data from a two year period provided byEvangelical Community Hospital in Lewisburg, Pennsylvania, to understand the variability of the turnover process. From the recorded data provided, we derive our best estimation of turnover time. Recognizing the importance of being able to properly modelturnover times in order to improve the accuracy of scheduling, we seek to fit distributions to the set of turnover times. We find that log-normal and log-logistic distributions are well-suited to turnover times, although further research must validate this finding. Wepropose that the choice of distribution depends on the hospital and, as a result, a hospital must choose whether to use the log-normal or the log-logistic distribution. Next, we use statistical tests to identify variables that may potentially influence turnover time. We find that there does not appear to be a correlation between surgerytime and turnover time across doctors. However, there are statistically significant differences between the mean turnover times across doctors. The final component of our research entails analyzing and explaining the benefits of introducing control charts as a quality control mechanism for monitoring turnover times in hospitals. Although widely instituted in other industries, control charts are notwidely adopted in healthcare environments, despite their potential benefits. A major component of our work is the development of control charts to monitor the stability of turnover times. These charts can be easily instituted in hospitals to reduce the variabilityof turnover times. Overall, our analysis uses operations research techniques to analyze turnover times and identify manners for improvement in lowering the mean turnover time and thevariability in turnover times. We provide valuable insight into a component of the surgery process that has received little attention, but can significantly affect utilization rates in hospitals. Most critically, an ability to more accurately predict turnover timesand a better understanding of the sources of variability can result in improved scheduling and heightened hospital staff and patient satisfaction. We hope that our findings can apply to many other hospital settings.
Resumo:
Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.
Resumo:
BACKGROUND Retinal optical coherence tomography (OCT) permits quantification of retinal layer atrophy relevant to assessment of neurodegeneration in multiple sclerosis (MS). Measurement artefacts may limit the use of OCT to MS research. OBJECTIVE An expert task force convened with the aim to provide guidance on the use of validated quality control (QC) criteria for the use of OCT in MS research and clinical trials. METHODS A prospective multi-centre (n = 13) study. Peripapillary ring scan QC rating of an OCT training set (n = 50) was followed by a test set (n = 50). Inter-rater agreement was calculated using kappa statistics. Results were discussed at a round table after the assessment had taken place. RESULTS The inter-rater QC agreement was substantial (kappa = 0.7). Disagreement was found highest for judging signal strength (kappa = 0.40). Future steps to resolve these issues were discussed. CONCLUSION Substantial agreement for QC assessment was achieved with aid of the OSCAR-IB criteria. The task force has developed a website for free online training and QC certification. The criteria may prove useful for future research and trials in MS using OCT as a secondary outcome measure in a multi-centre setting.
Resumo:
Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SP’s performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Methods SP trainers from all five Swiss medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised with the partners twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. Both, SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). FAIR_OSCE The list of items to assess the quality of the simulation by SPs was primarily developed and used to provide formative feedback to the SPs in order to help them to improve their performance. It was therefore named “Feedbackstruckture for the Assessment of Interactive Role play in Objective Structured Clinical Exams (FAIR_OSCE). It was also used to assess the quality of patient portrayal during the exam. The results were calculated for each of the five faculties individually. Formative evaluation was given to the five faculties with individual feedback without revealing results of other faculties other than overall results. Results High quality of patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. In example the rate of completely correct reaction in medical tests increased from 88% to 95%. 95% completely correct reactions together with 4% sufficient reactions add up to 99% of the reactions meeting the requirements of the exam. SP educators using the instrument reported an augmentation of SPs performance induced by the use of the instrument. Disadvantages mentioned were high concentration needed to explicitly observe all criteria and cumbersome handling of the paper-based forms. Conclusion We were able to document a very high quality of SP performance in our exam. The data also indicate that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed augmentation of performance. The development of an iPad based application for the form is planned to address the cumbersome handling of the paper.