939 resultados para Pseudorandom generator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved chemical strategy for processing of the generator produced 68Ga was developed based on processing of the original 68Ge/68Ga generator eluate on a micro-column. Direct pre-concentration and purification of the eluted 68Ga is performed on a cation-exchange resin in hydrochloric acid/acetone media. A supplementary step based on a second micro-column filled with a second resin allows direct re-adsorption of 68Ga eluted from the cation exchanger. 68Ga is finally striped from the second resin with a small volume of pure water. For this purpose a strong anion exchanger and a novel extraction chromatographic resin based on tetraalkyldiglycolamides are characterized. The strategy allows online pre-concentration and purification of 68Ga from the original generator eluate. The supplementary column allows transferring 68Ga with high radionuclide and chemical quality in the aqueous solution with small volume and low acidity useful for direct radiolabeling reactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Jing Ltd. miniature combustion aerosol standard (Mini-CAST) soot generator is a portable, commercially available burner that is widely used for laboratory measurements of soot processes. While many studies have used the Mini-CAST to generate soot with known size, concentration, and organic carbon fraction under a single or few conditions, there has been no systematic study of the burner operation over a wide range of operating conditions. Here, we present a comprehensive characterization of the microphysical, chemical, morphological, and hygroscopic properties of Mini-CAST soot over the full range of oxidation air and mixing N-2 flow rates. Very fuel-rich and fuel-lean flame conditions are found to produce organic-dominated soot with mode diameters of 10-60nm, and the highest particle number concentrations are produced under fuel-rich conditions. The lowest organic fraction and largest diameter soot (70-130nm) occur under slightly fuel-lean conditions. Moving from fuel-rich to fuel-lean conditions also increases the O:C ratio of the soot coatings from similar to 0.05 to similar to 0.25, which causes a small fraction of the particles to act as cloud condensation nuclei near the Kelvin limit (kappa similar to 0-10(-3)). Comparison of these property ranges to those reported in the literature for aircraft and diesel engine soots indicates that the Mini-CAST soot is similar to real-world primary soot particles, which lends itself to a variety of process-based soot studies. The trends in soot properties uncovered here will guide selection of burner operating conditions to achieve optimum soot properties that are most relevant to such studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy-harvesting devices attract wide interest as power supplies of today's medical implants. Their long lifetime will spare patients from repeated surgical interventions. They also offer the opportunity to further miniaturize existing implants such as pacemakers, defibrillators or recorders of bio signals. A mass imbalance oscillation generator, which consists of a clockwork from a commercially available automatic wrist watch, was used as energy harvesting device to convert the kinetic energy from the cardiac wall motion to electrical energy. An MRI-based motion analysis of the left ventricle revealed basal regions to be energetically most favorable for the rotating unbalance of our harvester. A mathematical model was developed as a tool for optimizing the device's configuration. The model was validated by an in vitro experiment where an arm robot accelerated the harvesting device by reproducing the cardiac motion. Furthermore, in an in vivo experiment, the device was affixed onto a sheep heart for 1 h. The generated power in both experiments-in vitro (30 μW) and in vivo (16.7 μW)-is sufficient to power modern pacemakers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microfluidic hydrogen generator is presented in this work. Its fabrication, characterization, and integration with a micro proton exchange membrane (PEM) fuel cell are described. Hydrogen gas is generated by the hydrolysis of aqueous ammonia borane. Gas generation, as well as the circulation of ammonia borane from a rechargeable fuel reservoir, is performed without any power consumption. To achieve this, directional growth and selective venting of hydrogen gas is maintained in the microchannels, which results in the circulation of fresh reactant from the fuel reservoir. In addition to this self-circulation mechanism, the hydrogen generator has been demonstrated to self-regulate gas generation to meet demands of a connected micro fuel cell. All of this is done without parasitic power consumption from the fuel cell. Results show its feasibility in applications of high-impedance systems. Lastly, recommendations for improvements and suggestions for future work are described

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A physical random number generator based on the intrinsic randomness of quantum mechanics is described. The random events are realized by the choice of single photons between the two outputs of a beamsplitter. We present a simple device, which minimizes the impact of the photon counters’ noise, dead-time and after pulses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the complexity of active medical implants increases, the task of embedding a life-long power supply at the time of implantation becomes more challenging. A periodic renewal of the energy source is often required. Human energy harvesting is, therefore, seen as a possible remedy. In this paper, we present a novel idea to harvest energy from the pressure-driven deformation of an artery by the principle of magneto-hydrodynamics. The generator relies on a highly electrically conductive fluid accelerated perpendicularly to a magnetic field by means of an efficient lever arm mechanism. An artery with 10 mm inner diameter is chosen as a potential implantation site and its ability to drive the generator is established. Three analytical models are proposed to investigate the relevant design parameters and to determine the existence of an optimal configuration. The predicted output power reaches 65 μW according to the first two models and 135 μW according to the third model. It is found that the generator, designed as a circular structure encompassing the artery, should not exceed a total volume of 3 cm3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the heart's action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited. The aim of this article is to explore the technical feasibility of harvesting 1 mW electric power using a miniature hydrodynamic turbine powered by about 1% of the cardiac output flow in a peripheral artery. To this end, numerical modelling of the fluid mechanics and experimental verification of the overall performance of a 1:1 scale friction turbine are performed in vitro. The numerical flow model is validated for a range of turbine configurations and flow conditions (up to 250 mL/min) in terms of hydromechanic efficiency; up to 15% could be achieved with the nonoptimized configurations of the study. Although this article does not entail the clinical feasibility of intravascular turbines in terms of hemocompatibility and impact on the circulatory system, the numerical model does provide first estimates of the mechanical shear forces relevant to blood trauma and platelet activation. It is concluded that the time-integrated shear stress exposure is significantly lower than in cardiac assist devices due to lower flow velocities and predominantly laminar flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An autonomous energy source within a human body is of key importance in the development of medical implants. This work deals with the modelling and the validation of an energy harvesting device which converts the myocardial contractions into electrical energy. The mechanism consists of a clockwork from a commercially available wrist watch. We developed a physical model which is able to predict the total amount of energy generated when applying an external excitation. For the validation of the model, a custom-made hexapod robot was used to accelerate the harvesting device along a given trajectory. We applied forward kinematics to determine the actual motion experienced by the harvesting device. The motion provides translational as well as rotational motion information for accurate simulations in three-dimensional space. The physical model could be successfully validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The respiratory central pattern generator is a collection of medullary neurons that generates the rhythm of respiration. The respiratory central pattern generator feeds phrenic motor neurons, which, in turn, drive the main muscle of respiration, the diaphragm. The purpose of this thesis is to understand the neural control of respiration through mathematical models of the respiratory central pattern generator and phrenic motor neurons. ^ We first designed and validated a Hodgkin-Huxley type model that mimics the behavior of phrenic motor neurons under a wide range of electrical and pharmacological perturbations. This model was constrained physiological data from the literature. Next, we designed and validated a model of the respiratory central pattern generator by connecting four Hodgkin-Huxley type models of medullary respiratory neurons in a mutually inhibitory network. This network was in turn driven by a simple model of an endogenously bursting neuron, which acted as the pacemaker for the respiratory central pattern generator. Finally, the respiratory central pattern generator and phrenic motor neuron models were connected and their interactions studied. ^ Our study of the models has provided a number of insights into the behavior of the respiratory central pattern generator and phrenic motor neurons. These include the suggestion of a role for the T-type and N-type calcium channels during single spikes and repetitive firing in phrenic motor neurons, as well as a better understanding of network properties underlying respiratory rhythm generation. We also utilized an existing model of lung mechanics to study the interactions between the respiratory central pattern generator and ventilation. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a practical activity, part of the renewable energy course where the students have to build their own complete wind generation system, including blades, PM-generator, power electronics and control. After connecting the system to the electric grid the system has been tested during real wind scenarios. The paper will describe the electric part of the work surface-mounted permanent magnet machine design criteria as well as the power electronics part for the power control and the grid connection. A Kalman filter is used for the voltage phase estimation and current commands obtained in order to control active and reactive power. The connection to the grid has been done and active and reactive power has been measured in the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of abstract machines involves complex decisions regarding, e.g., data representation, opcodes, or instruction specialization levéis, all of which affect the final performance of the emulator and the size of the bytecode programs in ways that are often difficult to foresee. Besides, studying alternatives by implementing abstract machine variants is a time-consuming and error-prone task because of the level of complexity and optimization of competitive implementations, which makes them generally difficult to understand, maintain, and modify. This also makes it hard to genérate specific implementations for particular purposes. To ameliorate those problems, we propose a systematic approach to the automatic generation of implementations of abstract machines. Different parts of their definition (e.g., the instruction set or the infernal data and bytecode representation) are kept sepárate and automatically assembled in the generation process. Alternative versions of the abstract machine are therefore easier to produce, and variants of their implementation can be created mechanically, with specific characteristics for a particular application if necessary. We illustrate the practicality of the approach by reporting on an implementation of a generator of production-quality WAMs which are specialized for executing a particular fixed (set of) program(s). The experimental results show that the approach is effective in reducing emulator size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe lpdoc, a tool which generates documentation manuals automatically from one or more logic program source files, written in Ciao, ISO-Prolog, and other (C)LP languages. It is particularly useful for documenting library modules, for which it automatically generates a rich description of the module interface. However, it can also be used quite successfully to document full applications. A fundamental advantage of using lpdoc is that it helps maintaining a true correspondence between the program and its documentation, and also identifying precisely to what versión of the program a given printed manual corresponds. The quality of the documentation generated can be greatly enhanced by including within the program text assertions (declarations with types, modes, etc. ...) for the predicates in the program, and machine-readable comments. One of the main novelties of lpdoc is that these assertions and comments are written using the Ciao system asseriion language, which is also the language of communication between the compiler and the user and between the components of the compiler. This allows a significant synergy among specification, debugging, documentation, optimization, etc. A simple compatibility library allows conventional (C)LP systems to ignore these assertions and comments and treat normally programs documented in this way. The documentation can be generated interactively from emacs or from the command line, in many formats including texinfo, dvi, ps, pdf, info, ascii, html/css, Unix nroff/man, Windows help, etc., and can include bibliographic citations and images, lpdoc can also genérate "man" pages (Unix man page format), nicely formatted plain ASCII "readme" files, installation scripts useful when the manuals are included in software distributions, brief descriptions in html/css or info formats suitable for inclusión in on-line Índices of manuals, and even complete WWW and info sites containing on-line catalogs of documents and software distributions. The lpdoc manual, all other Ciao system manuals, and parts of this paper are generated by lpdoc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe lpdoc, a tool which generates documentation manuals automatically from one or more logic program source files, written in ISO-Prolog, Ciao, and other (C)LP languages. It is particularly useful for documenting library modules, for which it automatically generates a rich description of the module interface. However, it can also be used quite successfully to document full applications. The documentation can be generated in many formats including t e x i n f o, dvi, ps, pdf, inf o, html/css, Unix nrof f/man, Windows help, etc., and can include bibliographic citations and images, lpdoc can also genérate "man" pages (Unix man page format), nicely formatted plain ascii "readme" files, installation scripts useful when the manuals are included in software distributions, brief descriptions in html/css or inf o formats suitable for inclusión in on-line Índices of manuals, and even complete WWW and inf o sites containing on-line catalogs of documents and software distributions. A fundamental advantage of using lpdoc is that it helps maintaining a true correspondence between the program and its documentation, and also identifying precisely to what versión of the program a given printed manual corresponds. The quality of the documentation generated can be greatly enhanced by including within the program text assertions (declarations with types, modes, etc. ...) for the predicates in the program, and machine-readable comments. These assertions and comments are written using the Ciao system assertion language. A simple compatibility library allows conventional (C)LP systems to ignore these assertions and comments and treat normally programs documented in this way. The lpdoc manual, all other Ciao system manuals, and most of this paper, are generated by lpdoc.