1000 resultados para Processamento de sinais acústicos submarinos


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Originally aimed at operational objectives, the continuous measurement of well bottomhole pressure and temperature, recorded by permanent downhole gauges (PDG), finds vast applicability in reservoir management. It contributes for the monitoring of well performance and makes it possible to estimate reservoir parameters on the long term. However, notwithstanding its unquestionable value, data from PDG is characterized by a large noise content. Moreover, the presence of outliers within valid signal measurements seems to be a major problem as well. In this work, the initial treatment of PDG signals is addressed, based on curve smoothing, self-organizing maps and the discrete wavelet transform. Additionally, a system based on the coupling of fuzzy clustering with feed-forward neural networks is proposed for transient detection. The obtained results were considered quite satisfactory for offshore wells and matched real requisites for utilization

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O processamento da informação sonora depende da integridade das vias auditivas aferentes e eferentes. O sistema auditivo eferente pode ser avaliado por meio dos reflexos acústicos e da supressão das emissões otoacústicas. OBJETIVO: Verificar a atividade do sistema auditivo eferente, por meio da supressão das emissões otoacústicas (EOA) e da sensibilização do reflexo acústico no distúrbio de processamento auditivo. CASUÍSTICA E MÉTODO: Estudo prospectivo: 50 crianças com alteração de processamento auditivo (grupo estudo) e 38 sem esta alteração (grupo controle), avaliadas por meio das EOA na ausência e presença de ruído contralateral e da pesquisa dos limiares do reflexo acústico na ausência e presença de estímulo facilitador contralateral. RESULTADOS: O valor médio da supressão das EOA foi de até 1,50 dB para o grupo controle e de até 1,26 dB para o grupo estudo. O valor médio da sensibilização dos reflexos foi de até 14,60 dB para o grupo estudo e de até 15,21 dB para o grupo controle. Não houve diferença estatisticamente significante entre as respostas dos grupos controle e estudo em ambos os procedimentos. CONCLUSÃO: O grupo estudo apresentou valores reduzidos na supressão das EOA e valores aumentados na sensibilização do reflexo acústico, em relação ao grupo controle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Em idosos, os resultados da avaliação comportamental das vias auditivas centrais são considerados de difícil interpretação devido à possível interferência do comprometimento das vias auditivas periféricas. OBJETIVO: Avaliar a eficiência das funções auditivas centrais de idosos que relatam ouvir bem. MATERIAL E MÉTODO: Estudo de casos que incluiu 40 indivíduos na faixa etária de 60 a 75 anos. Os pacientes foram submetidos à avaliação do processamento auditivo que constou de anamnese, exame otorrinolaringológico, audiometria tonal liminar, limiar de reconhecimento de fala, índice de reconhecimento de fala, imitanciometria, pesquisa de reflexos estapedianos, teste de identificação de sentenças sintéticas com mensagem competitiva ipsilateral, teste de padrões de freqüência e teste de dissílabos alternados por meio de tarefa dicótica. RESULTADOS: Gênero, faixa etária e perda auditiva não influenciaram os resultados dos testes de padrões de freqüência e dissílabos alternados por meio de tarefa dicótica; faixa etária e perda auditiva influenciaram os resultados do teste de identificação de sentenças com mensagem competitiva ipsilateral. Porcentagens de acertos abaixo dos padrões da normalidade de adultos foram observadas nos três testes que acessam as funções auditivas centrais. CONCLUSÃO: Indivíduos idosos que relatam ouvir bem apresentam prevalência relevante de sinais de ineficiência das funções auditivas centrais.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As comunicações ópticas e as comunicações sem fios têm sofrido uma grande evolução ao longo das últimas décadas. Com o objectivo de juntar as vantagens de cada um dos sistemas surgiu o que se designa por rádio sobre fibra. Este sistema permite centralizar todo o processamento necessário num só local, na estação central, simplificando assim a estação base. Esta simplificação permite reduzir os custos de implementação e torna o sistema menos complexo. Esta dissertação de mestrado tem como objectivo principal estudar e simular um sistema que permite o envio de sinaisdeo e rádio pela fibra óptica para posterior difusão, utilizando o conceito de rádio sobre fibra. Os sinais enviados foram o LTE (Long Term Evolution), o UWB (Ultra WideBand) e o WiMAX (Worldwide Interoperability for Microwave Access). O primeiro disponibiliza o serviço de voz, o segundo disponibiliza o serviço de televisão e o último dá suporte à internet. Estes sinais foram modulados em OFDM (Orthogonal Frequency Division Multiplex), porque, posteriormente, estes sinais vão ser difundidos num ambiente sem fios e este tipo de modulação minimiza o efeito de multipercurso e da interferência intersimbólica. Com este estudo pretende-se verificar qual a viabilidade de um sistema que permite o envio de três sinais distintos simultaneamente (serviço Triple Play). Ao analisar os resultados deste sistema concluiu-se que a sua aplicabilidade pode apresentar algumas limitações, dependendo do tipo de modulação e do tipo de modulador que se utilize. Os moduladores ópticos utilizados foram o MZ (Mach-Zehnder) e o EA (Electro-Absorption). A qualidade do sinal recebido foi analisada com base no valor de EVM (Error Vector Magnitude). O primeiro modulador foi aquele que apresentou mais limitações, pois o desempenho do sistema é comprometido para distâncias superiores a 40 km e para potências de entrada inferiores a 0 dBm. Este tipo de sistema apresenta um EVM mais baixo quando a potência de entrada utilizada está entre 0 e 6 dBm. Se o modulador utilizado for o EA, o sistema apresenta um EVM mais baixo quando se utiliza um índice de modulação entre 20% e 30%, para uma potência de entrada entre 0 e 2 dBm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia de Eletrónica e Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Devido ao crescente desenvolvimento das nanotecnologias, estando associadas a melhoria da eficiência energética assim como mais processamento de dados e a redução dos custos, esta dissertação possibilita todo o enquadramento com sistemas modernos ao nível do áudio digital. Tendo como base esta perspetiva, esta dissertação apresenta um sistema de áudio completo desde a fonte do sinal digital no PC até ao sinal analógico no altifalante. O sistema é constituído pelos seguintes módulos: a interface do utilizador no PC, o Processador Digital de Sinais (DSP), o amplificador digital e os altifalantes. O sistema é baseado na amplificação de classe D controlada por um modulador sigma delta (ΣΔM) digital. São abordadas as técnicas utilizadas e os cuidados a ter em conta em cada módulo, tendo como principal objetivo uma boa qualidade de áudio. Diferentes arquiteturas ΣΔM são primeiramente analisadas por simulações para validar a estabilidade e a funcionalidade, seguidamente são implementadas ao nível físico no protótipo para qualificar algumas medições elétricas e testes acústicos básicos. Depois de selecionados os ΣΔM mais promissores, o sistema foi avaliado pela análise de alguns testes elétricos de alto nível assim como gravações do sinal de áudio em um ambiente de estúdio controlado. Os resultados acústicos são comparados com um sistema de estúdio com reconhecimento no mercado. As medições finais do protótipo revelaram valores do rendimento de até 72%, a SNR na saída do amplificador digital de 73 dB através da leitura com o Audio Precision ATS-2, com uma THD de -75 dB e uma gama dinâmica (DR) de 75 dB. A tensão de alimentação pode ir dos 5 aos 12 Volt, utilizando uma metodologia H-bridge na saída do amplificador, e podendo ser aplicada uma carga mínima de 4 Ohm. O sistema desenvolvido demonstra-se promissor e possibilita melhorias através de otimização de cada elemento em particular, desde adicionar capacidades ao DSP através de novo firmware, ou melhorar a potência do amplificador digital consoante os requisitos da aplicação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Um dos maiores desafios da neurofisiologia é o de compreender a forma como a informação é transmitida através do sistema nervoso. O estudo do sistema nervoso tem várias aplicações, tanto na neurologia, permitindo avanços ao nível clínico, como noutras áreas, e.g., nos sistemas de processamento de informação baseados em redes neuronais. A transmissão de informação entre neurónios é feita por via de sinais elétricos. A compreensão deste fenómeno é ainda incompleta e há projectos a nível europeu e mundial com o objetivo de modular o sistema nervoso no seu todo de forma a melhor o compreender. Uma das teses que se desenvolve hoje em dia é a de que a transmissão de sinais elétricos no sistema nervoso é influenciada por fenómenos de sincronia. O objetivo desta dissertação é o de otimizar um protocolo de aquisição e análise de dados reais de eletroencefalograma e eletromiograma com o propósito de observar fenómenos de sincronia, baseando-se num algoritmo (análise por referência de fase, ou RPA, do inglês reference phase analysis) que deteta sincronias de fase entre os sinais de eletroencefalograma (EEG) e um sinal de referência, que é, no caso presente, o eletromiograma (EMG). A otimização deste protocolo e sua validação indicaram a existência de fenómenos significativos de sincronia no sinal elétrico, transmitido entre os músculos da mão e o córtex motor, no decorrer da ação motora.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The occurrence of transients in electrocardiogram (ECG) signals indicates an electrical phenomenon outside the heart. Thus, the identification of transients has been the most-used methodology in medical analysis since the invention of the electrocardiograph (device responsible for benchmarking of electrocardiogram signals). There are few papers related to this subject, which compels the creation of an architecture to do the pre-processing of this signal in order to identify transients. This paper proposes a method based on the signal energy of the Hilbert transform of electrocardiogram, being an alternative to methods based on morphology of the signal. This information will determine the creation of frames of the MP-HA protocol responsible for transmitting the ECG signals through an IEEE 802.3 network to a computing device. That, in turn, may perform a process to automatically sort the signal, or to present it to a doctor so that he can do the sorting manually

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Brain-Computer Interfaces (BCI) have as main purpose to establish a communication path with the central nervous system (CNS) independently from the standard pathway (nervous, muscles), aiming to control a device. The main objective of the current research is to develop an off-line BCI that separates the different EEG patterns resulting from strictly mental tasks performed by an experimental subject, comparing the effectiveness of different signal-preprocessing approaches. We also tested different classification approaches: all versus all, one versus one and a hierarchic classification approach. No preprocessing techniques were found able to improve the system performance. Furthermore, the hierarchic approach proved to be capable to produce results above the expected by literature

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente trabalho trata da filtragem e reconstrução de sinais em frequência intermediária usando FPGA. É feito o desenvolvimento de algoritmos usando processamento digital de sinais e também a implementação dos mesmos, constando desde o projeto da placa de circuito impresso, montagem e teste. O texto apresenta um breve estudo de amostragem e reconstrução de sinais em geral. Especial atenção é dada à amostragem de sinais banda-passante e à análise de questões práticas de reconstrução de sinais em frequência intermediária. Dois sistemas de reconstrução de sinais baseados em processamento digital de sinais, mais especificamente reamostragem no domínio discreto, são apresentados e analisados. São também descritas teorias de processos de montagem e soldagem de placas eletrônicas com objetivo de definir uma metodologia de projeto, montagem e soldagem de placas eletrônicas. Tal metodologia é aplicada no projeto e manufatura do protótipo de um módulo de filtragem digital para repetidores de telefonia celular. O projeto, implementado usando FPGA, é baseado nos dois sistemas supracitados. Ao final do texto, resultados obtidos em experimentos de filtragem digital e reconstrução de sinais em frequência intermediária com o protótipo desenvolvido são apresentados.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esta dissertação tem como objetivo principal propor um nodo (ou nó) sensor sem fio para ser utilizado em redes de sensores sem fio, em sistemas de aquisição de dados de extensômetros. O sistema de aquisição para os extensômetros é baseado na ponte de Wheatstone e de modo a permitir várias configurações de extensômetros. O processamento e a comunicação sem fio é realizada pelo ATmega128RFA1, composto por um microcontrolador e um transceiver Rádio-Frequência com o padrão Zigbee. O nodo foi projetado para garantir confiabilidade na aquisição de dados e ser totalmente controlado remotamente. Entre os parâmetros controláveis estão: o ganho do sinal e a taxa de amostragem. Além disso, o nodo possui recursos para efetuar o equilíbrio da ponte de Wheatstone automaticamente. A escolha de seus componentes, baseou-se em critérios relacionados ao consumo de energia do mesmo e ao custo. Foi concebida uma placa de circuito impresso (PCI) para o nodo, e sobre ela foram realizadas estimativas sobre o consumo de energia e valor agregado do protótipo, com o objetivo de analisar a sua viabilidade. Além do projeto do nodo sensor, o trabalho apresenta a proposta de integração do mesmo em uma rede de sensores sem fio (RSSF), incluindo a sugestão do hardware complementar e desenvolvimentos dos softwares. Para os testes do nodo sensor, foi construido experimentalmente um transdutor de força.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A monitorização ambulatorial do eletrocardiograma (ECG) permite seguir as atividades cotidianas do paciente durante períodos de 24 horas (ou ainda maiores) possibilitando o estudo de casos que pudessem ter episódios arrítmicos fatais. Entretanto, o maior desafio tecnológico que este tipo de monitorização enfrenta é a perda de informação pela presença de ruídos e artefatos quando o paciente se move. A análise do intervalo QT de despolarização e repolarização ventricular do eletrocardiograma superficial é uma técnica não invasiva com um grande valor para a diagnose e prognósticos de cardiopatias e neuropatias, assim como para a predição da morte cardíaca súbita. A análise do desvio padrão do intervalo QT proporciona informação sobre a dispersão (temporal ou espacial) da repolarização ventricular, entretanto a influencia do ruído provoca erros na detecção do final da onda T que são apreciáveis devido ao fato dos valores pequenos do desvio padrão do QT tanto para sujeitos patológicos e quanto para os sãos. O objetivo geral desta tese é melhorar os métodos de processamento do sinal de ECG ambulatorial usando inteligência computacional, especificamente os métodos relacionados com a detecção do final da onda T, e os de reconhecimento morfológico de batimentos que invalidam a análise da variabilidade do intervalo QT. É proposto e validado (em termos de exatidão e precisão) um novo método e algoritmo para estimar o final da onda T baseado no calculo de áreas de trapézios, empregando sinais da base de dados QT da Physionet. O desempenho do método proposto foi testado e comparado com um dos métodos mais usados para detectar o final da onda T: o método baseado no limiar na primeira derivada. O método de inteligência computacional sugerido combina a extração de características usando o método de análise de componentes principais não lineares e a rede neural de tipo perceptron multicamada. O método de áreas de trapézios teve um bom desempenho em condições ruidosas e não depende de nenhum limiar empírico, sendo adequado para situações com níveis de elevados de ruído de banda larga. O método de reconhecimento morfológico de batimentos foi avaliado com sinais ambulatoriais com e sem artefatos pertencentes a bases de dados de prestigio internacional, e mostrou um bom desempenho.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi estimar a entropia conjunta do sistema visual humano no domínio do espaço e no domínio das freqüências espaciais através de funções psicométricas. Estas foram obtidas com testes de discriminação de estímulos com luminância ou cromaticidade moduladas por funções de Gábor. A essência do método consistiu em avaliar a entropia no domínio do espaço, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em extensão espacial, e avaliar a entropia no domínio das freqüências espaciais, testando-se a capacidade do sujeito em discriminar estímulos que diferiam apenas em freqüência espacial. A entropia conjunta foi calculada, então, a partir desses dois valores individuais de entropia. Três condições visuais foram estudadas: acromática, cromática sem correção fina para eqüiluminância e cromática com correção para eqüiluminância através de fotometria com flicker heterocromático. Quatro sujeitos foram testados nas três condições, dois sujeitos adicionais foram testados na condição cromática sem eqüiluminância fina e um sétimo sujeito também fez o teste acromático. Todos os sujeitos foram examinados por oftalmologista e considerados normais do ponto de vista oftálmico, não apresentando relato, sintomas ou sinais de disfunções visuais ou de moléstias potencialmente capazes de afetar o sistema visual. Eles tinham acuidade visual normal ou corrigida de no mínimo 20/30. O trabalho foi aprovado pela Comissão de Ética em Pesquisa do Núcleo de Medicina Tropical da UFPA e obedeceu às recomendações da Declaração de Helsinki. As funções de Gábor usadas para modulação de luminância ou cromaticidade compreenderam redes senoidais unidimensionais horizontais, moduladas na direção vertical, dentro de envelopes gaussianos bidimensionais cuja extensão espacial era medida pelo desvio padrão da gaussiana. Os estímulos foram gerados usando-se uma rotina escrita em Pascal num ambiente Delphi 7 Enterprise. Foi utilizado um microcomputador Dell Precision 390 Workstation e um gerador de estímulos CRS VSG ViSaGe para exibir os estímulos num CRT de 20”, 800 x 600 pixels, 120 Hz, padrão RGB, Mitsubishi Diamond Pro 2070SB. Nos experimentos acromáticos, os estímulos foram gerados pela modulação de luminância de uma cor branca correspondente à cromaticidade CIE1931 (x = 0,270; y = 0,280) ou CIE1976 (u’ = 0,186; v’= 0,433) e tinha luminância média de 44,5 cd/m2. Nos experimentos cromáticos, a luminância média foi mantida em 15 cd/m2 e foram usadas duas series de estímulos verde-vermelhos. Os estímulos de uma série foram formados por duas cromaticidades definidas no eixo M-L do Espaço de Cores DKL (CIE1976: verde, u’=0,131, v’=0,380; vermelho, u’=0,216, v’=0,371). Os estímulos da outra série foram formados por duas cromaticidades definidas ao longo de um eixo horizontal verde-vermelho definido no Espaço de Cores CIE1976 (verde, u’=0,150, v’=0,480; vermelho, u’=0,255, v’=0,480). Os estímulos de referência eram compostos por redes de três freqüências espaciais diferentes (0,4, 2 e 10 ciclos por grau) e envelope gaussiano com desvio padrão de 1 grau. Os estímulos de testes eram compostos por uma entre 19 freqüências espaciais diferentes em torno da freqüência espacial de referência e um entre 21 envelopes gaussianos diferentes com desvio padrão em torno de 1 grau. Na condição acromática, foram estudados quatro níveis de contraste de Michelson: 2%, 5%, 10% e 100%. Nas duas condições cromáticas foi usado o nível mais alto de contraste agregado de cones permitidos pelo gamut do monitor, 17%. O experimento consistiu numa escolha forçada de dois intervalos, cujo procedimento de testagem compreendeu a seguinte seqüência: i) apresentação de um estímulo de referência por 1 s; ii) substituição do estímulo de referência por um fundo eqüiluminante de mesma cromaticidade por 1 s; iii) apresentação do estímulo de teste também por 1 s, diferindo em relação ao estímulo de referência seja em freqüência espacial, seja em extensão espacial, com um estímulo sonoro sinalizando ao sujeito que era necessário responder se o estímulo de teste era igual ou diferente do estímulo de referência; iv) substituição do estímulo de teste pelo fundo. A extensão espacial ou a freqüência espacial do estímulo de teste foi mudada aleatoriamente de tentativa para tentativa usando o método dos estímulos constantes. Numa série de 300 tentativas, a freqüencia espacial foi variada, noutra série também de 300 tentativas, a extensão espacial foi variada, sendo que cada estímulo de teste em cada série foi apresentado pelo menos 10 vezes. A resposta do indivíduo em cada tentativa era guardada como correta ou errada para posterior construção das curvas psicométricas. Os pontos experimentais das funções psicométricas para espaço e freqüência espacial em cada nível de contraste, correspondentes aos percentuais de acertos, foram ajustados com funções gaussianas usando-se o método dos mínimos quadrados. Para cada nível de contraste, as entropias para espaço e freqüência espacial foram estimadas pelos desvios padrões dessas funções gaussianas e a entropia conjunta foi obtida multiplicando-se a raiz quadrada da entropia para espaço pela entropia para freqüência espacial. Os valores de entropia conjunta foram comparados com o mínimo teórico para sistemas lineares, 1/4π ou 0,0796. Para freqüências espaciais baixas e intermediárias, a entropia conjunta atingiu níveis abaixo do mínimo teórico em contrastes altos, sugerindo interações não lineares entre dois ou mais mecanismos visuais. Este fenômeno occorreu em todas as condições (acromática, cromática e cromática eqüiluminante) e foi mais acentuado para a frequência espacial de 0,4 ciclos / grau. Uma possível explicação para este fenômeno é a interação não linear entre as vias visuais retino-genículo-estriadas, tais como as vias K, M e P, na área visual primária ou em níveis mais altos de processamento neural.