990 resultados para Pressão intraocular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose
To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality.

Setting
Cathedral Eye Clinic, Belfast, United Kingdom.

Design
Retrospective comparative case series.

Methods
Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal near-segment placement and the other, superotemporal near-segment placement. A +3.00 diopter (D) reading addition (add) was used in all eyes. The main outcome measures included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), contrast sensitivity, and quality of vision. Follow-up was 3 months.

Results
Patients ranged in age from 43 to 76 years. The inferonasal group comprised 80 eyes (40 patients) and the superotemporal group, 76 eyes (38 patients). The mean 3-month spherical equivalent was −0.11 D ± 0.49 (SD) in the inferonasal group and −0.18 ± 0.46 D in the superotemporal group. The mean postoperative UDVA was 0.14 ± 0.10 logMAR and 0.18 ± 0.15 logMAR, respectively. The mean monocular UNVA was 0.21 ± 0.14 logRAD and 0.24 ± 0.13 logRAD, respectively. No significant differences were observed in the higher-order aberrations, total Strehl ratio (point-spread function), or modulation transfer function between the groups. Dysphotopic symptoms measured with a validated quality-of-vision questionnaire were not significantly different between groups.

Conclusion
Positioning of the near add did not significantly affect objective or subjective visual function parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current therapies that target vascular endothelial growth factor (VEGF) have become a mainstream therapy for the management of diabetic macular oedema. The treatment involves monthly repeated intravitreal injections of VEGF inhibitors. VEGF is an important growth factor for many retinal cells, including different types of neurons. In this study, we investigated the adverse effect of multiple intravitreal anti-VEGF injections (200 ng/μl/eye anti-mouse VEGF164, once every 2 weeks totalling 5-6 injections) to retinal neurons in Ins2(Akita) diabetic mice. Funduscopic examination revealed the development of cotton wool spot-like lesions in anti-VEGF treated Ins2(Akita) mice after 5 injections. Histological investigation showed focal swellings of retinal nerve fibres with neurofilament disruption. Furthermore, anti-VEGF-treated Ins2(Akita) mice exhibited impaired electroretinographic responses, characterized by reduced scotopic a- and b-wave and oscillatory potentials. Immunofluorescent staining revealed impairment of photoreceptors, disruptions of synaptic structures and loss of amacrine and retinal ganglion cells in anti-VEGF treated Ins2(Akita) mice. Anti-VEGF-treated WT mice also presented mild amacrine and ganglion cell death, but no overt abnormalities in photoreceptors and synaptic structures. At the vascular level, exacerbated albumin leakage was observed in anti-VEGF injected diabetic mice. Our results suggest that sustained intraocular VEGF neutralization induces retinal neurodegeneration and vascular damage in the diabetic eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pediatric ophthalmologists increasingly recognize that the ideal site for intraocular lens (IOL) implantation is in the bag for aphakic eyes, but it is always very difficult via conventional technique. We conducted a prospective case series study to investigate the success rate and clinical outcomes of capsular bag reestablishment and in-the-bag IOL implantation via secondary capsulorhexis with radiofrequency diathermy (RFD) in pediatric aphakic eyes, in which twenty-two consecutive aphakic pediatric patients (43 aphakic eyes) enrolled in the Childhood Cataract Program of the Chinese Ministry of Health were included. The included children underwent either our novel technique for secondary IOL implantation (with RFD) or the conventional technique (with a bent needle or forceps), depending on the type of preoperative proliferative capsular bag present. In total, secondary capsulorhexis with RFD was successfully applied in 32 eyes (32/43, 74.4%, age 5.6±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved in 30 eyes (30/43, 70.0%), but in the remaining 2 eyes (2/32, 6.2%) the IOLs were implanted in the sulcus with a capsular bag that was too small. Secondary capsulorhexis with conventional technique was applied in the other 11 eyes (11/43, 25.6%, age 6.9±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved only in 3 eyes(3/43, 7.0%), and the IOLs were implanted in the sulcus in the remaining 8 eyes. A doughnut-like proliferative capsular bag with an extensive Soemmering ring (32/43, 74.4%) was the main success factor for secondary capsulorhexis with RFD, and a sufficient capsular bag size (33/43, 76.7%) was an additional factor in successful in-the-bag IOL implantation. In conclusion, RFD secondary capsulorhexis technique has 70% success rate in the capsular bag reestablishment and in-the-bag IOL implantation in pediatric aphakic eyes, particularly effective in cases with a doughnut-like, extensively proliferative Soemmering ring. © 2013 Luo et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TOPIC:

To analyze the literature pertaining to the techniques used in combined cataract and glaucoma surgery, including the technique of cataract extraction, the timing of the surgery (staged procedure versus combined procedure), the anatomic location of the operation, and the use of antifibrosis agents.

CLINICAL RELEVANCE:

Cataract and glaucoma are both common conditions and are often present in the same patient. There is no agreement concerning the optimal surgical management of these disorders when they coexist.

METHODS/LITERATURE REVIEWED:

Electronic searches of English language articles published since 1964 were conducted in Pub MED and CENTRAL, the Cochrane Collaboration's database. These were augmented by a hand search of six ophthalmology journals and the reference lists of a sample of studies included in the literature review. Evidence grades (A, strong; B, moderate; C, weak; I, insufficient) were assigned to the evidence that involved a direct comparison of alternative techniques.

RESULTS:

The preponderance of evidence from the literature suggests a small (2-4 mmHg) benefit from the use of mitomycin-C (MMC), but not 5-fluorouracil (5-FU), in combined cataract and glaucoma surgery (evidence grade B). Two-site surgery provides slightly lower (1-3 mmHg) intraocular pressure (IOP) than one-site surgery (evidence grade C), and IOP is lowered more (1-3 mmHg) by phacoemulsification than by nuclear expression in combined procedures (evidence grade C). There is insufficient evidence to conclude either that staged or combined procedures give better results or that alternative glaucoma procedures are superior to trabeculectomy in combined procedures.

CONCLUSIONS:

In the literature on surgical techniques and adjuvants used in the management of coexisting cataract and glaucoma, the strongest evidence of efficacy exists for using MMC, separating the incisions for cataract and glaucoma surgery, and removing the nucleus by phacoemulsification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To investigate the heritability of intraocular pressure (IOP) and cup-to-disc ratio (CDR) in an older well-defined population.

DESIGN:

Family-based cohort study.

PARTICIPANTS:

Through the population-based Salisbury Eye Evaluation study, we recruited 726 siblings (mean age, 74.7 years) in 284 sibships.

METHODS:

Intraocular pressure and CDR were measured bilaterally for all participants. The presence or absence of glaucoma was determined by a glaucoma specialist for all probands on the basis of visual field, optic nerve appearance, and history. The heritability of IOP was calculated as twice the residual between-sibling correlation of IOP using linear regression and generalized estimating equations after adjusting for age, gender, mean arterial pressure, race, self-reported diabetes status, and history of systemic steroid use. The heritability of CDR was calculated using the same model and adjustments as above, while also adjusting for IOP.

MAIN OUTCOME MEASURES:

Heritability and determinants of IOP and CDR, and impact of siblings' glaucoma status on IOP and CDR.

RESULTS:

We estimated the heritability to be 0.29 (95% confidence interval [CI], 0.12-0.46) for IOP and 0.56 (95% CI, 0.35-0.76) for CDR in this population. Mean IOP in siblings of glaucomatous probands was statistically significantly higher than in siblings of normal probands (mean difference, 1.02 mmHg; P = 0.017). The mean CDR in siblings of glaucomatous probands was 0.07 (or 19%) larger than in siblings of glaucoma suspect referrals (P = 0.045) and siblings of normal probands (P = 0.004).

CONCLUSIONS:

In this elderly population, we found CDR to be highly heritable and IOP to be moderately heritable. On average, siblings of glaucoma patients had higher IOPs and larger CDRs than siblings of nonglaucomatous probands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We studied the effects on intraocular pressure (IOP) of anesthesia administered during examination under anesthesia (EUA) in children. DESIGN: Randomized clinical trial. METHODS: This randomized trial compared IOP after inhaled sevoflurane gas to that after intramuscular ketamine hydrochloride in children undergoing EUA. IOP was measured in 30 eyes with TonoPen XL (Mentor, Inc, Norwell, Massachusetts, USA) as soon as possible after anesthesia induction (T1) and two, four, six, and eight minutes thereafter. At the same times, we recorded systolic and diastolic blood pressure (SBP, DBP) and heart rate (HR). RESULTS: Compared with the mean IOP at T1, IOP in the sevoflurane group was significantly lower for all measurements from two to eight minutes thereafter (mean decrease in IOP: two minutes = 12%, four minutes = 19%; six minutes = 19%; eight minutes = 17%, all P < or = .01). In the ketamine group, mean IOP was not significantly changed from T1 through six minutes, whereas at eight minutes, it was 7% lower (P = .03). SBP and DBP were significantly lower for sevoflurane than for ketamine at all measurements from two minutes onward, and HR was lower for sevoflurane than for ketamine at two, four, and six minutes. CONCLUSIONS: IOP measured after ketamine sedation is more likely to represent the awake IOP than that after sevoflurane anesthesia. Changes in SBP, DBP, and HR caused by sevoflurane suggest that hemodynamic alterations may underlie its effects on IOP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. METHODS: Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). RESULTS: The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P < .001). CONCLUSION: Although the pressure phosphene tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Recent studies report that increased corneal edema because of contact lens wear under closed lids is associated with elevated Goldmann intraocular pressure (GAT IOP). We sought to assess whether the impact of postoperative corneal edema on GAT IOP would be similar and to determine the differential effect of different amounts of edema. METHODS: The setting is a tertiary level cataract clinic in Shantou, China. Pre- and postoperative (day 1) GAT IOP, central corneal thickness (CCT), corneal hysteresis, corneal resistance factor, and radius of corneal curvature were measured for consecutive patients undergoing phacoemulsification surgery by 2 experienced surgeons. Corneal edema was calculated as the percentage increase in CCT. RESULTS: Among 136 subjects (mean age, 62.5 ± 15.4 years; 53.7% women), the mean increase in CCT was 10.3% postoperatively. Greater corneal edema was associated with lower GAT IOP in unadjusted analyses (P < 0.03) and in linear regression models (P < 0.01). In the model, higher corneal resistance factor (P < 0.001), lower corneal hysteresis (P < 0.001), and steeper radius of corneal curvature (P < 0.001) were associated with higher GAT IOP. Among subjects with edema < the median, edema was associated with lower GAT IOP (P = 0.004), whereas among those with edema ≥ the median, edema was not associated with GAT IOP. An increase in CCT of 7% was associated with an 8 mm Hg underestimation of GAT IOP in our models. CONCLUSIONS: The effect of postoperative edema on GAT IOP seems to be the opposite of contact lens-induced edema. The magnitude of the effect is potentially relevant to patient management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the distribution of central corneal thickness (CCT), intraocular pressure (IOP), and their determinants and association with glaucoma in Chinese adults.DESIGN: Population-based cross-sectional study.METHODS: Chinese adults aged 50 years and older were identified using cluster random sampling in Liwan District, Guangzhou. CCT (both optical [OCCT] and ultrasound [UCCT]), intraocular pressure (by Tonopen, IOP), refractive error (by autorefractor, RE), radius of corneal curvature (RCC), axial length (AL), and body mass index (BMI) were measured, and history of hypertension and diabetes (DM) was collected by questionnaire. Right eye data were analyzed.RESULTS: The mean values of OCCT, UCCT, and IOP were 512 ± 29.0 μm, 542 ± 31.4 μm, and 15.2 ± 3.1 mm Hg, respectively. In multiple regression models, CCT declined with age (P < .001) and increased with greater RCC (P < .001) and DM (P = .037). IOP was positively associated with greater CCT (P < .001), BMI (P < .001), and hypertension (P < .001). All 25 persons with open-angle glaucoma had IOP <21 mm Hg. CCT did not differ significantly between persons with and without open- or closed-angle glaucoma. Among 65 persons with ocular hypertension (IOP >97.5th percentile), CCT (555 ± 29 μm) was significantly (P = .01) higher than for normal persons.CONCLUSIONS: The distributions of CCT and IOP in this study are similar to that for other Chinese populations, though IOP was lower than for European populations, possibly due to lower BMI and blood pressure. Glaucoma with IOP <21 mm Hg is common in this population. We found no association between glaucoma and CCT, though power (0.3) for this analysis was low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We conducted a systematic review and meta-analysis of observational studies to evaluate the effect of oral statins on intraocular pressure (IOP) and the incidence and progression of glaucoma. Methods: This was a systematic review of the literature and meta-analysis. Searches of PubMed/Medline and Embase were conducted to include all types of studies. Gray literature abstracts were also considered for inclusion. Last search date was February 2016. Risk of bias was assessed using the Newcastle-Ottawa scale independently by two reviewers. Odds ratios (OR) or hazard ratios (HR) and 95% confidence intervals (CI) were extracted from each study. Pooled ORs for incidence of glaucoma were calculated using a random-effects model. Results: We identified seven cohort studies, three case–control studies, and one cross-sectional study with a total number of 583,615 participants. No randomized controlled trials were retrieved. Pooled ORs demonstrated a statistically significant association between short-term statin use (≤2 years) and reduced incidence of glaucoma (OR 0.96, 95%CI 0.94, 0.99). Pooled ORs of long-term statin use (>2 years) did not demonstrate statistically significant reduction in incidence of glaucoma (OR 0.70, 95%CI 0.46, 1.06). There was inconsistent evidence for the protective effect of statins against the progression of glaucoma, although there was no standard definition for progression across studies. There was no significant difference in IOP associated with statin use. Conclusions: Short-term statin use is associated with a reduced incidence of glaucoma. The effect of statins on glaucoma progression and IOP is uncertain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente trabalho consistiu no estudo das propriedades viscoelásticas de suspensões de amido nativo e processado a alta pressão. Foi utilizado um sensor acústico de forma a analisar as propriedades das suspensões, sendo depois recolhidas informações complementares através de outras técnicas: calorimetria diferencial de varrimento, microscopia de luz polarizada e microscopia eletrónica de varrimento. Neste trabalho foram realizados estudos com amido de milho nativo e processado a alta pressão (500 MPa, 5 minutos, temperatura ambiente), tendo-se verificado que a suspensão do amido processado apresentava propriedades viscoelásticas muito diferentes do amido nativo. A temperatura a que se iniciou o aumento da viscosidade foi mais elevada para o amido processado a alta pressão, e as variações observadas para temperaturas superiores a 70 °C foram menores. Durante o arrefecimento foi detetada uma diminuição da viscosidade, correspondente a um aumento da organização molecular, com maior expressão no amido nativo mas que se dá no mesmo intervalo de temperatura, quer para este quer o processado a alta pressão. Foi também possível concluir que a velocidade de aquecimento da amostra de amido influencia as propriedades viscoelásticas da suspensão e as temperaturas a que ocorrem as variações de viscosidade relacionadas com o processo de gelatinização do amido. De assinalar também que no amido de milho se pode detetar pela variação da frequência do cristal piezoelétrico o rompimento dos grânulos e que apesar do estabelecimento de novas ligações e da reposição de alguma ordem molecular que se pode verificar durante o arrefecimento, a frequência da suspensão depois de arrefecida era muito diferente da suspensão de amido inicial. No amido de arroz, a temperatura a que se inicia o aumento de viscosidade foi superior à que se observou para o amido de milho, indicio da maior resistência do amido de arroz, para o qual não se detetou sinal de rutura dos grânulos. A frequência final da suspensão do mesmo, depois de arrefecido, era igual à inicial. Com o amido de arroz foi feito o estudo da influência da temperatura no processamento de alta pressão, tendo sido processadas suspensões a 400 MPa, durante 15 minutos, a 5, 10, 23 e 34 °C. As propriedades viscoelásticas foram analisadas com recurso a um sensor acústico, tendo-se verificado que quanto maior a temperatura de processamento a alta pressão, mais elevada a temperatura necessária para que se inicie o aumento de viscosidade e menores as temperaturas a que se inicia diminuição da mesma durante o arrefecimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No âmbito da unidade curricular “Dissertação, Projeto ou Estágio” do mestrado em Geomática, é desenvolvido um estágio curricular com a duração de 86 dias (645 horas) na Empresa de Desenvolvimento e Infra-estruturas do Alqueva, SA (EDIA). Este estágio tem como objetivo principal fornecer a primeira experiência profissional na área dos Sistemas de Informação Geográfica (SIG), permitindo desenvolver e consolidar as competências adquiridas ao longo do curso. Este relatório de estágio tem como finalidade dar a conhecer as atividades desenvolvidas pela aluna, e também servir como complemento ao manual da aplicação utilizada, o SIGOPRAM uma vez que o respetivo manual não reúne toda a informação necessária para que o utilizador menos experiente consiga desenvolver uma simulação na aplicação. O trabalho realizado incide na utilização de dois modelos distintos, o de dimensionamento e o de simulação, permitindo analisar o desempenho da aplicação, uma vez que esta nunca tinha sido utilizada na EDIA. Opta-se por aplicar os dois modelos para uma rede de rega pequena, tendo em consideração o tempo de duração do estágio e o facto de, no início do estágio, a aluna não estar familiarizada com a área de Hidráulica. O modelo de dimensionamento é aplicado a uma rede de rega do sub-bloco Cuba Este 1, de forma a analisar o comportamento do software DIOPRAM e a validar os seus resultados, através de uma comparação entre os resultados obtidos pela aplicação do modelo e os resultados de dimensionamento obtidos pela equipa projetista externa. Com a aplicação do modelo de dimensionamento obtêm-se resultados sobre o caudal, pressão dinâmica, velocidade, diâmetro e tipo de material aplicado em cada troço, otimizados de forma a obter a rede mais barata possível. Com a aplicação do modelo de simulação, são analisados possíveis problemas operacionais que a rede possa apresentar, ao nível da pressão e de velocidade de circulação da água nas condutas, através do software EPANET.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos: Pretende-se verificar as modificações neuromotoras após uma intervenção baseada no conceito de Bobath ao nível dos ajustes posturais durante o alcance funcional dos membros superiores, em três crianças com paralisia cerebral. Pretende-se também, verificar o efeito desta abordagem nas atividades e participação, bem como destacar os aspetos individuais das mesmas crianças com a capacidade de mudança após a intervenção. Metodologia: A avaliação foi realizada antes e três meses após a intervenção em fisioterapia segundo o conceito de Bobath. Optou-se por um registo observacional com uma Máquina Fotográfica Digital, um sistemas de Câmaras de Vídeo, uma Plataforma de Forças e, utilizaram-se ainda instrumentos como o Gross Motor Functional Measure– versão 88 itens, o Gross Motor Function Classification System, o Teste de Alcance Funcional Modificado e a ferramenta, Classificação Internacional de Funcionalidade, Incapacidade e Saúde – crianças e jovens. Resultados: Verificou-se um progresso nos ajustes posturais e na funcionalidade em geral, o que se repercutiu na restrição da participação e na limitação da actividade. A postura na posição de sentado, o deslocamento do centro de pressão, a capacidade de deslocamento no sentido anterior, bem como as capacidades motoras grosseiras modificaram-se em todas as crianças, tendo a criança B apresentado a maior e a criança A a menor capacidade de mudança após a intervenção. Conclusão: A intervenção segundo o Conceito de Bobath promoveu modificações neuromotoras, o que levaram a uma melhoria da funcionalidade geral, da mobilidade e do controlo postural da criança, refletindo-se nos ajustes posturais durante o alcance funcional dos membros superiores na posição de sentado. Verificou-se ainda, uma melhoria na restrição da participação e na limitação da actividade diária.