985 resultados para Position emission tomography
Resumo:
A number of techniques have been developed to study the disposition of drugs in the head and, in particular, the role of the blood-brain barrier (BBB) in drug uptake. The techniques can be divided into three groups: in-vitro, in-vivo and in-situ. The most suitable method depends on the purpose(s) and requirements of the particular study being conducted. In-vitro techniques involve the isolation of cerebral endothelial cells so that direct investigations of these cells can be carried out. The most recent preparations are able to maintain structural and functional characteristics of the BBB by simultaneously culturing endothelial cells with astrocytic cells,The main advantages of the in-vitro methods are the elimination of anaesthetics and surgery. In-vivo methods consist of a diverse range of techniques and include the traditional Brain Uptake Index and indicator diffusion methods, as well as microdialysis and positron emission tomography. In-vivo methods maintain the cells and vasculature of an organ in their normal physiological states and anatomical position within the animal. However, the shortcomings include renal acid hepatic elimination of solutes as well as the inability to control blood flow. In-situ techniques, including the perfused head, are more technically demanding. However, these models have the ability to vary the composition and flow rate of the artificial perfusate. This review is intended as a guide for selecting the most appropriate method for studying drug uptake in the brain.
Resumo:
Human cytosolic thymidine kinase (hTK1) has proven to be a suitable target for the noninvasive imaging of cancer cell proliferation using radiolabeled thymidine analogues such as [(18)F]3'-fluoro-3'-deoxythymidine ([(18)F]FLT). A thymidine analogue for single photon emission computed tomography (SPECT), which incorporates the readily available and inexpensive nuclide technetium-99m, would be of considerable practical interest. hTK1 is known to accommodate modification of the structure of the natural substrate thymidine at the positions N3 and C3' and, to a lesser extent, C5. In this work, we used the copper-catalyzed azide-alkyne cycloaddition to synthesize two series of derivatives in which thymidine is functionalized at either the C3' or N3 position with chelating systems suitable for the M(CO)(3) core (M = (99m)Tc, Re). The click chemistry approach enabled complexes with different structures and overall charges to be synthesized from a common precursor. Using this strategy, the first organometallic hTK1 substrates in which thymidine is modified at the C3' position were identified. Phosphorylation of the organometallic derivatives was measured relative to thymidine. We have shown that the influence of the overall charge of the derivatives is dependent on the position of functionalization. In the case of the C3'-functionalized derivatives, neutral and anionic substrates were most readily phosphorylated (20-28% of the value for the parent ligand thymidine), whereas for the N3-functionalized derivatives, cationic and neutral complexes were apparently better substrates for the enzyme (14-18%) than anionic derivatives (9%).
Resumo:
Objective To correlate the results of 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and Methods Cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results The authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of 18F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas.
Resumo:
The purpose of gamma spectrometry and gamma and X-ray tomography of nuclear fuel is to determine both radionuclide concentration and integrity and deformation of nuclear fuel. The aims of this thesis have been to find out the basics of gamma spectrometry and tomography of nuclear fuel, to find out the operational mechanisms of gamma spectrometry and tomography equipment of nuclear fuel, and to identify problems that relate to these measurement techniques. In gamma spectrometry of nuclear fuel the gamma-ray flux emitted from unstable isotopes is measured using high-resolution gamma-ray spectroscopy. The production of unstable isotopes correlates with various physical fuel parameters. In gamma emission tomography the gamma-ray spectrum of irradiated nuclear fuel is recorded for several projections. In X-ray transmission tomography of nuclear fuel a radiation source emits a beam and the intensity, attenuated by the nuclear fuel, is registered by the detectors placed opposite. When gamma emission or X-ray transmission measurements are combined with tomographic image reconstruction methods, it is possible to create sectional images of the interior of nuclear fuel. MODHERATO is a computer code that simulates the operation of radioscopic or tomographic devices and it is used to predict and optimise the performance of imaging systems. Related to the X-ray tomography, MODHERATO simulations have been performed by the author. Gamma spectrometry and gamma and X-ray tomography are promising non-destructive examination methods for understanding fuel behaviour under normal, transient and accident conditions.
Resumo:
Eine häufige Art der Chemotherapie ist die Behandlung von Tumoren mit alkylierenden oder chloralkylierenden Zytostatika, die eine Alkylierung von Guanin in der DNA verursachen. Daraus resultieren eine Blockierung der DNA-Synthese und ein Rückgang im Tumorwachstum. Das Enzym O6-Methylguanin-DNA-methyltransferase (MGMT) ist in der Lage, solche Schäden zu reparieren. Da MGMT auch in verschiedenen Tumorarten exprimiert wird, eine Tatsache, die therapeutische Effekte verringern könnte, wird zur Zeit die Gabe von Inhibitoren der MGMT, wie O6-Benzylguanin, vor der eigentlichen Chemotherapie untersucht. Um möglicher Weise die Selektivität dieser Verbindungen für Tumor- vs. gesundem Gewebe und auch die in vivo-Eigenschaften zu verbessern, wurden glycosylierte Inhibitoren vorgeschlagen. Für eine Entwicklung neuer MGMT-Inhibitoren wäre es hilfreich, die in vivo Bioverteilung in Tier und Mensch durch eine Markierung mit geeigneten Isotopen verfolgen zu können. Im Moment existiert keine Möglichkeit, den MGMT-Status eines Tumors nicht-invasiv zu visualisieren. Diese Information kann sehr wichtig für die Planung einer Chemotherapie mit alkylierenden oder chloralkylierenden Zytostatika sein. Mit Methoden wie der Positronen-Emissions-Tomographie (PET) oder der Einzel-Photonen-Emissions-Tomographie (SPECT) ist eine nicht-invasive Quantifizierung von biochemischen Prozessen prinzipiell möglich. Hierfür wurden verschiedenen MGMT-Inhibitoren bereits mit Isotopen wie Fluor-18, Kohlenstoff-11 un Iod-131 markiert, aber sie waren aus unterschiedlichen Gründen nicht geeignet. Das Ziel dieser Arbeit war die Entwicklung von neuen O6-derivatisierten Guaninen, die über einen C8-Spacer an der N9-Position des Guanins mit einer Glucose-Einheit konjugiert werden sollten, geeigneten Markierungsvorläufern und Radioiodierungs-Methoden. Durch Wahl eines geeigneten Radioiodisotops für die Markierung des Restes an der O6-Position des Guanins kann die ex vivo-Bioverteilung dieser Verbindungen in tumortragenden Nacktmäusen (Iod-131) und die Untersuchung der in vivo-Verteilung (Iod-123) durchgeführt werden. Daher wurden O6-(5-Iodothenyl)- (ITG) und O6-(3-Iodbenzyl)guanin-Derivate (IBG) sowie ihre Glucose-Konjugate ITGG und IBGG synthetisiert. Von diesen inaktiven Standard-Verbindungen wurden die IC50-Werte zur MGMT bestimmt. Da sie alle im nM-Bereich lagen, schienen die Verbindungen für weitere Untersuchungen geeignet zu sein. Die Radiomarkierung der Inhibitoren mit Iod-131 bzw. Iod-123 wurde durch Umsetzung der Trialkyl-stannylierten Markierungsvorläufer mit der Chloramin T-Methode in mittleren (Iod-123) bis hohen (Iod-131) radiochemischen Ausbeuten und mit hohen radiochemischen Reinheiten durchgeführt. Mit den 131I-iodierten Verbindungen wurde die spezifische Bindung zur MGMT nachgewiesen, eine Eigenschaft, die essentiell für eine weitere Verwendung dieser Derivate ist. Sie wurden auch zur Bestimmung der ex vivo-Tumor- und Organverteilung in tumortragenden Nacktmäusen (MEX(+), MEX(-), Glioblastom) verwendet. In allen Fällen war die Tumoraufnahme der nicht-konjugierten Guanin-Derivate höher als die der entsprechenden Glucose-Konjugate. Das Tumor-Blut-Verhältnis, das sehr wichtig für einen potentiellen Einsatz der Verbindungen als Tracer des MGMT-Status eines Tumors ist, variierte abhängig von der Kinetik. Zu allen Zeitpunkten war die in vivo-Deiodierung der Glucose-Konjugate deutlich geringer als die von ITG oder IBG. Unter Verwendung von [131I]IBG und [131I]IBGG wurde die Biodistribution nach Inhibition der Natrium-abhängigen Glucose-Transporter, die zumindests teilweise für die Aufnahme der MGMT-Inhibitoren in Zellen verantwortlich sind, durch Phloretin untersucht. Einen Unterschied in der Tumoraufnahme zwischen den mit Phloretin behandelten und den unbehandelten Mäusen konnte nicht beobachtet werden, wahrscheinlich weil die Akkumulation im Tumor generell niedrig war. Mit den 123I-iodierten Verbindungen [123I]IBG und [123I]IBGG wurden in vivo-Scans an tumortragenden Nacktmäusen (MEX(+), MEX(-)) mit einer Kleintier-SPECT-Kamera durchgeführt. In beiden Fällen wurde eine geringe Akkumulation in den Tumoren im Vergleich zu anderen Organen beobachtet, was die ex vivo-Biodistributionsdaten bestätigte.
Resumo:
Glutamat ist der wichtigste exzitatorische Neurotransmitter im Gehirn. Folglich spielen Glutamat-kontrollierte Rezeptorsysteme eine entscheidende Rolle in neurologischen Vorgängen, wie beispielsweise in Lern- und Gedächtnisprozessen. Gerade der NMDA-Rezeptor ist in eine Vielzahl solcher Vorgänge involviert und wird vor allem mit neurodegenerativen Erkrankungen wie Chorea Huntington, Morbus Alzheimer, Morbus Parkinson und zerebraler Ischämie in Verbindung gebracht. Folglich stellt die Visualisierung des NMDA-Rezeptorstatus eine Möglichkeit dar, den Verlauf solcher Prozesse zu untersuchen.rnDie Positronen-Emissions-Tomographie (PET) ist eine leistungsstarke Anwendung in der molekularen Bildgebung und erlaubt die in vivo-Visualisierung sowie Quantifizierung biochemischer Prozesse. Durch die Verwendung geeigneter Tracer können bestimmte pathologische und neurologische Abläufe beurteilt werden. rnZurzeit sind keine geeigneten PET-Tracer zur Untersuchung des NMDA-Rezeptors verfügbar. Bisher dargestellte PET-Liganden zeichneten sich durch nicht zufriedenstellende Affinitäten und Selektivitäten aus und führten meist auf Grund der hohen Lipophilie zu einem hohen Maß an unspezifischer Bindung. rnDie Strychnin-insensitive Glycinbindungsstelle des NMDA-Rezeptors stellt ein vielversprechendes Target dar, spezifische Liganden für diese Bindungsstelle zu synthetisieren. Hier zeichnen sich einige Verbindungsklassen durch exzellente Affinitäten und Selektivitäten sowie durch vielversprechende in vivo-Eigenschaften aus. rnAuf Grundlage dieser biologischen Daten wurden zwei Substanzen der 2-Indolcarbonsäure, nämlich die 4,6-Dichlor-3-(2-oxo-3-phenylimidazolidin-1-ylmethyl)-1H-indol-2-carbonsäure (MDJ-114) und die (E)-4,6-Dichlor-3-(2-phenylcarbamoylvinyl)-1H-indol-2-carbonsäure (GV150526), als Leitstruktur gewählt. Ferner wurde das 7-Chlor-4-hydroxy-3-(3-phenoxyphenyl)-1H-chinolin-2-on (L-701,324) aus der Substanzklasse der 4-Hydroxy-1H-chinolin-2-one als dritte Leitstruktur gewählt.rnFür diese Substanzen wurden 19F-markierte Analogverbindungen synthetisiert, um als inaktive Referenzverbindungen auf ihre Eignung überprüft zu werden. Hierzu wurde eine Fluorethoxygruppierung im terminalen Phenylring der entsprechenden Leitstruktur eingeführt. Durch Variation der Fluorethoxysubstitution in ortho-, meta- und para-Stellung, konnten die besten Affinitäten in einem kompetitiven Rezeptorbindungsassay durch Verdrängung von [3H]MDL-105,519 bestimmt werden. Als Maß für die Lipophilie wurden die entsprechenden log D-Werte über die HPLC-Methode bestimmt. Basierend auf den Ergebnissen der Evaluierung wurden zwei Derivate identifiziert, welche zur 18F-Markierung genutzt werden sollten (GV150526-Derivat 34: log D = 0,23 ± 0,03, IC50 = 0,20 ± 0,25 µM, Ki = 0,13 ± 0,16 µM; L701,324-Derivat 55: log D = - 0,25 ± 0,01, IC50 = 78 ± 37 µM, Ki = 51 ± 24 µM). Die 18F-Markierung erfolgte durch die Reaktion des entsprechenden Markierungsvorläufers mit dem Markierungssynthon 2-[18F]Fluorethyltosylat, welches durch die Umsetzung von Ethylenditosylat mit [18F]Fluorid hergestellt wurde. Die Radiosynthesen der beiden 18F-markierten Verbindungen [18F]34 (4,6-Dichlor-3-{2-[4-(2-[18F]fluorethoxy)-phenylcarbamoyl]-vinyl}-1H-indol-2-carbonsäure) und [18F]55 (7-Chlor-3-{3-[4-(2-[18F]fluorethoxy)-phenoxy]-phenyl}-4-hydroxy-1H-chinolin-2-on) wurden optimiert sowie semipräparative Abtrennverfahren entwickelt. Beide Tracer wurden auf ihre in vivo-Eignung im µPET-Experiment untersucht. Die Zeitaktivitätskurven lassen erkennen, dass beide Tracer entgegen der Erwartung nicht die Blut-Hirn-Schranke überwinden können. Für das GV150526-Derivat ([18F]34) wurden zusätzlich Autoradiographiestudien durchgeführt. Die erhaltenen Aufnahmen zeigten ein heterogenes Verteilungsmuster der Aktivitätsanreicherung. Ebenso wurde ein hohes Maß an unspezifischer Bindung beobachtet. Möglicherweise sind Cross-Affinitäten zu anderen Rezeptorsystemen oder der recht hohe lipophile Rest des Moleküls hierfür verantwortlich. Ein Grund für die unzureichende Hirngängigkeit der Radioliganden kann sich in der Carboxylatfunktion des GV150526-Derivats bzw. in der 4-Hydroxy-1H-chinolin-2-on-Einheit des L-701,324-Derivats wiederspiegeln. rnAuf Grundlage dieser Resultate können Versuche unternommen werden, für die Verbindungsklasse der 2-Indolcarbonsäuren entsprechende Ester als Prodrugs mit einer verbesserten Bioverfügbarkeit darzustellen. Ebenso können neue Strukturen als Grundlage für neue PET-Tracer untersucht werden.rnrn
Resumo:
Our understanding of regional filling of the lung and regional ventilation distribution is based on studies using stepwise inhalation of radiolabelled tracer gases, magnetic resonance imaging and positron emission tomography. We aimed to investigate whether these differences in ventilation distribution at different end-expiratory levels (EELs) and tidal volumes (V (T)s) held also true during tidal breathing. Electrical impedance tomography (EIT) measurements were performed in ten healthy adults in the right lateral position. Five different EELs with four different V (T)s at each EEL were tested in random order, resulting in 19 combinations. There were no measurements for the combination of the highest EEL/highest V (T). EEL and V (T) were controlled by visual feedback based on airflow. The fraction of ventilation directed to different slices of the lung (VENT(RL1)-VENT(RL8)) and the rate of the regional filling of each slice versus the total lung were analysed. With increasing EEL but normal tidal volume, ventilation was preferentially distributed to the dependent lung and the filling of the right and left lung was more homogeneous. With increasing V (T) and maintained normal EEL (FRC), ventilation was preferentially distributed to the dependent lung and regional filling became more inhomogeneous (p < 0.05). We could demonstrate that regional and temporal ventilation distribution during tidal breathing was highly influenced by EEL and V (T).
Resumo:
Positron emission tomography-computed tomography (PET-CT) has gained widespread acceptance as a staging investigation in the diagnostic workup of malignant tumours and may be used to visualize metabolic changes before the evolution of morphological changes. To make histology of PET findings without distinctive structural changes available for treatment decisions, we developed a protocol for multimodal image-guided interventions using an integrated PET-CT machine. We report our first experience in 12 patients admitted for staging and restaging of breast cancer, non-small cell lung cancer, cervical cancer, soft tissue sarcoma, and osteosarcoma. Patients were repositioned according to the findings in PET-CT and intervention was planned based on a subsequent single-bed PET-CT acquisition of the region concerned. The needle was introduced under CT guidance in a step-by-step technique and correct needle position in the centre of the FDG avid lesion was assured by repetition of a single-bed PET-CT acquisition before sampling. The metabolically active part of lesions was accurately targeted in all patients and representative samples were obtained in 92%. No major adverse effects occurred. We conclude that PET-CT guidance for interventions is feasible and may be promising to optimize the diagnostic yield of CT-guided interventions and to make metabolically active lesions without morphological correlate accessible to percutaneous interventions.
Resumo:
PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.
Resumo:
Esta tesis recoje un trabajo experimental centrado en profundizar sobre el conocimiento de los bloques detectores monolíticos como alternativa a los detectores segmentados para tomografía por emisión de positrones (Positron Emission Tomography, PET). El trabajo llevado a cabo incluye el desarrollo, la caracterización, la puesta a punto y la evaluación de prototipos demostradores PET utilizando bloques monolíticos de ortosilicato de lutecio ytrio dopado con cerio (Cerium-Doped Lutetium Yttrium Orthosilicate, LYSO:Ce) usando sensores compatibles con altos campos magnéticos, tanto fotodiodos de avalancha (Avalanche Photodiodes, APDs) como fotomultiplicadores de silicio (Silicon Photomultipliers, SiPMs). Los prototipos implementados con APDs se construyeron para estudiar la viabilidad de un prototipo PET de alta sensibilidad previamente simulado, denominado BrainPET. En esta memoria se describe y caracteriza la electrónica frontal integrada utilizada en estos prototipos junto con la electrónica de lectura desarrollada específicamente para los mismos. Se muestran los montajes experimentales para la obtención de las imágenes tomográficas PET y para el entrenamiento de los algoritmos de red neuronal utilizados para la estimación de las posiciones de incidencia de los fotones γ sobre la superficie de los bloques monolíticos. Con el prototipo BrainPET se obtuvieron resultados satisfactorios de resolución energética (13 % FWHM), precisión espacial de los bloques monolíticos (~ 2 mm FWHM) y resolución espacial de la imagen PET de 1,5 - 1,7 mm FWHM. Además se demostró una capacidad resolutiva en la imagen PET de ~ 2 mm al adquirir simultáneamente imágenes de fuentes radiactivas separadas a distancias conocidas. Sin embargo, con este prototipo se detectaron también dos limitaciones importantes. En primer lugar, se constató una falta de flexibilidad a la hora de trabajar con un circuito integrado de aplicación específica (Application Specific Integrated Circuit, ASIC) cuyo diseño electrónico no era propio sino comercial, unido al elevado coste que requieren las modificaciones del diseño de un ASIC con tales características. Por otra parte, la caracterización final de la electrónica integrada del BrainPET mostró una resolución temporal con amplio margen de mejora (~ 13 ns FWHM). Tomando en cuenta estas limitaciones obtenidas con los prototipos BrainPET, junto con la evolución tecnológica hacia matrices de SiPM, el conocimiento adquirido con los bloques monolíticos se trasladó a la nueva tecnología de sensores disponible, los SiPMs. A su vez se inició una nueva estrategia para la electrónica frontal, con el ASIC FlexToT, un ASIC de diseño propio basado en un esquema de medida del tiempo sobre umbral (Time over Threshold, ToT), en donde la duración del pulso de salida es proporcional a la energía depositada. Una de las características más interesantes de este esquema es la posibilidad de manejar directamente señales de pulsos digitales, en lugar de procesar la amplitud de las señales analógicas. Con esta arquitectura electrónica se sustituyen los conversores analógicos digitales (Analog to Digital Converter, ADCs) por conversores de tiempo digitales (Time to Digital Converter, TDCs), pudiendo implementar éstos de forma sencilla en matrices de puertas programmable ‘in situ’ (Field Programmable Gate Array, FPGA), reduciendo con ello el consumo y la complejidad del diseño. Se construyó un nuevo prototipo demostrador FlexToT para validar dicho ASIC para bloques monolíticos o segmentados. Se ha llevado a cabo el diseño y caracterización de la electrónica frontal necesaria para la lectura del ASIC FlexToT, evaluando su linealidad y rango dinámico, el comportamiento frente a ruido así como la no linealidad diferencial obtenida con los TDCs implementados en la FPGA. Además, la electrónica presentada en este trabajo es capaz de trabajar con altas tasas de actividad y de discriminar diferentes centelleadores para aplicaciones phoswich. El ASIC FlexToT proporciona una excelente resolución temporal en coincidencia para los eventos correspondientes con el fotopico de 511 keV (128 ps FWHM), solventando las limitaciones de resolución temporal del prototipo BrainPET. Por otra parte, la resolución energética con bloques monolíticos leidos por ASICs FlexToT proporciona una resolución energética de 15,4 % FWHM a 511 keV. Finalmente, se obtuvieron buenos resultados en la calidad de la imagen PET y en la capacidad resolutiva del demostrador FlexToT, proporcionando resoluciones espaciales en el centro del FoV en torno a 1,4 mm FWHM. ABSTRACT This thesis is focused on the development of experimental activities used to deepen the knowledge of monolithic detector blocks as an alternative to segmented detectors for Positron Emission Tomography (PET). It includes the development, characterization, setting up, running and evaluation of PET demonstrator prototypes with monolithic detector blocks of Cerium-doped Lutetium Yttrium Orthosilicate (LYSO:Ce) using magnetically compatible sensors such as Avalanche Photodiodes (APDs) and Silicon Photomultipliers (SiPMs). The prototypes implemented with APDs were constructed to validate the viability of a high-sensitivity PET prototype that had previously been simulated, denominated BrainPET. This work describes and characterizes the integrated front-end electronics used in these prototypes, as well as the electronic readout system developed especially for them. It shows the experimental set-ups to obtain the tomographic PET images and to train neural networks algorithms used for position estimation of photons impinging on the surface of monolithic blocks. Using the BrainPET prototype, satisfactory energy resolution (13 % FWHM), spatial precision of monolithic blocks (~ 2 mm FWHM) and spatial resolution of the PET image (1.5 – 1.7 mm FWHM) in the center of the Field of View (FoV) were obtained. Moreover, we proved the imaging capabilities of this demonstrator with extended sources, considering the acquisition of two simultaneous sources of 1 mm diameter placed at known distances. However, some important limitations were also detected with the BrainPET prototype. In the first place, it was confirmed that there was a lack of flexibility working with an Application Specific Integrated Circuit (ASIC) whose electronic design was not own but commercial, along with the high cost required to modify an ASIC design with such features. Furthermore, the final characterization of the BrainPET ASIC showed a timing resolution with room for improvement (~ 13 ns FWHM). Taking into consideration the limitations obtained with the BrainPET prototype, along with the technological evolution in magnetically compatible devices, the knowledge acquired with the monolithic blocks were transferred to the new technology available, the SiPMs. Moreover, we opted for a new strategy in the front-end electronics, the FlexToT ASIC, an own design ASIC based on a Time over Threshold (ToT) scheme. One of the most interesting features underlying a ToT architecture is the encoding of the analog input signal amplitude information into the duration of the output signals, delivering directly digital pulses. The electronic architecture helps substitute the Analog to Digital Converters (ADCs) for Time to Digital Converters (TDCs), and they are easily implemented in Field Programmable Gate Arrays (FPGA), reducing the consumption and the complexity of the design. A new prototype demonstrator based on SiPMs was implemented to validate the FlexToT ASIC for monolithic or segmented blocks. The design and characterization of the necessary front-end electronic to read-out the signals from the ASIC was carried out by evaluating its linearity and dynamic range, its performance with an external noise signal, as well as the differential nonlinearity obtained with the TDCs implemented in the FPGA. Furthermore, the electronic presented in this work is capable of working at high count rates and discriminates different phoswich scintillators. The FlexToT ASIC provides an excellent coincidence time resolution for events that correspond to 511 keV photopeak (128 ps FWHM), resolving the limitations of the poor timing resolution of the BrainPET prototype. Furthermore, the energy resolution with monolithic blocks read by FlexToT ASICs provides an energy resolution of 15.4 % FWHM at 511 keV. Finally, good results were obtained in the quality of the PET image and the resolving power of the FlexToT demonstrator, providing spatial resolutions in the centre of the FoV at about 1.4 mm FWHM.
Resumo:
Background/Aims: Positron emission tomography has been applied to study cortical activation during human swallowing, but employs radio-isotopes precluding repeated experiments and has to be performed supine, making the task of swallowing difficult. Here we now describe Synthetic Aperture Magnetometry (SAM) as a novel method of localising and imaging the brain's neuronal activity from magnetoencephalographic (MEG) signals to study the cortical processing of human volitional swallowing in the more physiological prone position. Methods: In 3 healthy male volunteers (age 28–36), 151-channel whole cortex MEG (Omega-151, CTF Systems Inc.) was recorded whilst seated during the conditions of repeated volitional wet swallowing (5mls boluses at 0.2Hz) or rest. SAM analysis was then performed using varying spatial filters (5–60Hz) before co-registration with individual MRI brain images. Activation areas were then identified using standard sterotactic space neuro-anatomical maps. In one subject repeat studies were performed to confirm the initial study findings. Results: In all subjects, cortical activation maps for swallowing could be generated using SAM, the strongest activations being seen with 10–20Hz filter settings. The main cortical activations associated with swallowing were in: sensorimotor cortex (BA 3,4), insular cortex and lateral premotor cortex (BA 6,8). Of relevance, each cortical region displayed consistent inter-hemispheric asymmetry, to one or other hemisphere, this being different for each region and for each subject. Intra-subject comparisons of activation localisation and asymmetry showed impressive reproducibility. Conclusion: SAM analysis using MEG is an accurate, repeatable, and reproducible method for studying the brain processing of human swallowing in a more physiological manner and provides novel opportunities for future studies of the brain-gut axis in health and disease.
Resumo:
Although MRI is utilized for planning the resection of soft-tissue tumors, it is not always capable of differentiating benign from malignant lesions. The risk of local recurrence of soft-tissue sarcomas is increased when biopsies are performed before resection and by inadequate resections. PET associated with computed tomography using fluorodeoxyglucose labeled with fluorine-18 ((18)F-FDG PET/CT) may help differentiate between benign and malignant tumors, thus avoiding inadequate resections and making prior biopsies unnecessary. The purpose of this study was to evaluate the usefulness of (18)F-FDG PET/CT in differentiating benign from malignant solid soft-tissue lesions. Patients with solid lesions of the limbs or abdominal wall detected by MRI were submitted to (18)F-FDG PET/CT. The maximum standardized uptake value (SUVmax) cutoff was determined to differentiate malignant from benign tumors. Regardless of the (18)F-FDG PET/CT results all patients underwent biopsy and surgery. MRI was performed in 54 patients, and 10 patients were excluded because of purely lipomatose or cystic lesions. (18)F-FDG PET/CT was performed in the remaining 44 patients. Histopathology revealed 26 (59%) benign and 18 (41%) malignant soft-tissue lesions. A significant difference in SUVmax was observed between benign and malignant soft-tissue lesions. The SUVmax cutoff of 3.0 differentiated malignant from benign lesions with 100% sensitivity, 83.3% specificity, 89.6% accuracy, 78.3% positive predictive value, and 100% negative predictive value. (18)F-FDG PET/CT seems to be able to differentiate benign from malignant soft-tissue lesions with good accuracy and very high negative predictive value. Incorporating (18)F-FDG PET/CT into the diagnostic algorithm of these patients may prevent inadequate resections and unnecessary biopsies.
Resumo:
Background: Expectation is a very potent pain modulator in both humans and animals. There is evidence that pain transmission neurons are modulated by expectation preceding painful stimuli. Nonetheless, few studies have examined the influence of pain expectation on the pain-related neuronal activity and the functional connectivity within the central nociceptive network. Results: This study used a tone-laser conditioning paradigm to establish the pain expectation in rats, and simultaneously recorded the anterior cingulate cortex (ACC), the medial dorsal thalamus (MD), and the primary somatosensory cortex (SI) to investigate the effect of pain expectation on laser-induced neuronal responses. Cross-correlation and partial directed coherence analysis were used to determine the functional interactions within and between the recorded areas during nociceptive transmission. The results showed that under anticipation condition, the neuronal activity to the auditory cue was significantly increased in the ACC area, whereas those to actual noxious stimuli were enhanced in all the recorded areas. Furthermore, neuronal correlations within and between these areas were significantly increased under conditions of expectation compared to those under non-expectation conditions, indicating an enhanced synchronization of neural activity within the pain network. In addition, information flow from the medial (ACC and MD) to the lateral (SI cortex) pain pathway increased, suggesting that the emotion-related neural circuits may modulate the neuronal activity in the somatosensory pathway during nociceptive transmission. Conclusion: These results demonstrate that the nociceptive processing in both medial and lateral pain systems is modulated by the expectation of pain.
Resumo:
Objectives: Adults with major depressive disorder (MDD) are reported to have reduced orbitofrontal cortex (OFC) volumes, which could be related to decreased neuronal density. We conducted a study on medication naive children with MDD to determine whether abnormalities of OFC are present early in the illness course. Methods: Twenty seven medication naive pediatric Diagnostic and Statistical Manual of Mental Disorders, 4(th) edition (DSM-IV) MDD patients (mean age +/- SD = 14.4 +/- 2.2 years; 10 males) and 26 healthy controls (mean age +/- SD = 14.4 +/- 2.4 years; 12 males) underwent a 1.5T magnetic resonance imaging (MRI) with 3D spoiled gradient recalled acquisition. The OFC volumes were compared using analysis of covariance with age, gender, and total brain volume as covariates. Results: There was no significant difference in either total OFC volume or total gray matter OFC volume between MDD patients and healthy controls. Exploratory analysis revealed that patients had unexpectedly larger total right lateral (F = 4.2, df = 1, 48, p = 0.05) and right lateral gray matter (F = 4.6, df = 1, 48, p = 0.04) OFC volumes compared to healthy controls, but this finding was not significant following statistical correction for multiple comparisons. No other OFC subregions showed a significant difference. Conclusions: The lack of OFC volume abnormalities in pediatric MDD patients suggests the abnormalities previously reported for adults may develop later in life as a result of neural cell loss.
Resumo:
The coordination of movement is governed by a coalition of constraints. The expression of these constraints ranges from the concrete—the restricted range of motion offered by the mechanical configuration of our muscles and joints; to the abstract—the difficulty that we experience in combining simple movements into complex rhythms. We seek to illustrate that the various constraints on coordination are complementary and inclusive, and the means by which their expression and interaction are mediated systematically by the integrative action of the central nervous system (CNS). Beyond identifying the general principles at the behavioural level that govern the mutual interplay of constraints, we attempt to demonstrate that these principles have as their foundation specific functional properties of the cortical motor systems. We propose that regions of the brain upstream of the motor cortex may play a significant role in mediating interactions between the functional representations of muscles engaged in sensorimotor coordination tasks. We also argue that activity in these ldquosupramotorrdquo regions may mediate the stabilising role of augmented sensory feedback.