983 resultados para Plates
Resumo:
Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.
Resumo:
We present herein an improved assay for detecting the presence of extracellular proteases from microorganisms on agar plates. Using different substrates (gelatin, BSA, hemoglobin) incorporated into the agar and varying the culture medium composition, we were able to detect proteolytic activities from Pseudomonas aeruginosa, Micrococcus luteus and Serratia marcescens as well as the influence that these components displayed in the expression of these enzymes. For all microorganisms tested we found that in agar-BHI or yeast extract medium containing gelatin the sensitivity of proteinase detection was considerably greater than in BSA-agar or hemoglobin-agar. However, when BSA or hemoglobin were added to the culture medium, there was an increase in growth along with a marked reduction in the amount of proteinase production. In the case of M. luteus the incorporation of glycerol in BHI or yeast extract gelatin-agar induced protease liberation. Our results indicate that the technique described here is of value for detecting extracellular proteases directly in the culture medium, by means of a qualitative assay, simple, inexpensive, straight forward method to assess the presence of the proteolytic activity of a given microorganism colony with great freedom in substrate selection.
Resumo:
Searching for morphometric differences between sexes in immature forms, the development of genital plates in the exuviae of Triatoma pallidipennis Stål 1872nymphs was studied. Differences were found in the form and size of the 9th genital urosternite, it is larger and wider in males as compared to females. This difference is reported in several South American Triatoma species. From our results it is possible to sex early stages from microscopic observation of genital plates in whole insects.
Resumo:
This report is submitted by the Iowa Department of Transportation, Motor Vehicle Division in compliance with Administrative Rule 761-401.18(3) Discontinuance. This rule requires the department to report to the legislature if 250 paid applications for any of the special registration plates subject to this rule are not submitted within one year after the date the department makes the plate available for application in order to request authority to discontinue any of the special registration plates established under Iowa Code section 321.34, new subsections 20C, 25 and 26 as amended by 2011 Iowa Acts, House File 651, section 2.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
This report is submitted in compliance with Administrative Rule 761-401.18(3), Discontinuance, and discusses seven special registration plates established by the legislature in 2011. This rule requires the department to report to the legislature if any of the special registration plates subject to this rule have not been placed into production because the department has not received the minimum number of paid applications (250) required to produce the plates under Iowa Code section 321.34, subsections 20C, 25 and 26 as amended by 2011 Iowa Acts, House File 651, section 2.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
In this thesis, cleaning of ceramic filter plates clogged by iron oxides was studied. Oxalic acid is considered as the most effective cleaning agent for the plates fouled by iron oxides, but when using oxalic acid, sparingly soluble calcium oxalate may be formed and it can blind the filter media. Suitability of another chemical for cleaning the plates clogged by iron oxides was studied in this thesis. The literature part was mostly about the properties of the chemical, about its reactions, industrial uses, safety issues etc. In the experimental part, the efficiency of the chemical for cleaning of the ceramic plates clogged by iron oxides was studied. Two kinds of plates were used in the experiments; the others were clogged by hematite and the others by magnetite. Both soaking and flow-through experiments were done. A suitable concentration, pH and temperature were tried to find in the experiments. Also the effect of ultrasound was studied. The efficiency of the cleaning was examined by measuring the permeability of the plates during the experiments. ICP-OES analysis was performed for determining the amount of dissolved iron in the washing solution. Some experiments were also done with oxalic acid. The results from the oxalic acid experiments were compared to the results from the experiments with the other chemical. In the experiments with the other chemical, the permeability increased more and the amounts of dissolved iron were larger. According to the results from the experiments, the method of application of the washing solutions had an impact on the washing results.
Resumo:
This work presents a geometric nonlinear dynamic analysis of plates and shells using eight-node hexahedral isoparametric elements. The main features of the present formulation are: (a) the element matrices are obtained using reduced integrations with hourglass control; (b) an explicit Taylor-Galerkin scheme is used to carry out the dynamic analysis, solving the corresponding equations of motion in terms of velocity components; (c) the Truesdell stress rate tensor is used; (d) the vector processor facilities existing in modern supercomputers were used. The results obtained are comparable with previous solutions in terms of accuracy and computational performance.
Resumo:
A test that is rapid, simple, accurate, not expensive, gives rapid results, and is sensitive enough to detect low levels of microorganisms would be the most suitable for food industry routine laboratories, or even for a public health laboratories. A ready-to-use alternative, commercially available method is the PetrifilmTM EB method. The aim of this study was to evaluate whether there is a statistically significant difference between the conventional methods based on Violet Red Bile Glucose Agar and the alternative 3M TM Petrifilm (EB) method for the enumeration of Enterobacteriaceae in poultry carcasses. This study also assessed whether the alternative method showed ability to produce results that were directly proportional to the concentration of the target (approximately 270 colony-forming unit.mL-1). A total of 120 poultry carcasses samples showed a significant difference (p < 0.05) between the populations obtained by the two methods, and the conventional method showed low proportionality between the dilutions. On the other hand, the PetrifilmTM EB quantification system showed the capacity to produce results that are proportional to the concentration of the analyte in samples in the concentration range from 1 to 256 colony-forming unit.mL-1.
Resumo:
Thermal cutting methods, are commonly used in the manufacture of metal parts. Thermal cutting processes separate materials by using heat. The process can be done with or without a stream of cutting oxygen. Common processes are Oxygen, plasma and laser cutting. It depends on the application and material which cutting method is used. Numerically-controlled thermal cutting is a cost-effective way of prefabricating components. One design aim is to minimize the number of work steps in order to increase competitiveness. This has resulted in the holes and openings in plate parts manufactured today being made using thermal cutting methods. This is a problem from the fatigue life perspective because there is local detail in the as-welded state that causes a rise in stress in a local area of the plate. In a case where the static utilization of a net section is full used, the calculated linear local stresses and stress ranges are often over 2 times the material yield strength. The shakedown criteria are exceeded. Fatigue life assessment of flame-cut details is commonly based on the nominal stress method. For welded details, design standards and instructions provide more accurate and flexible methods, e.g. a hot-spot method, but these methods are not universally applied to flame cut edges. Some of the fatigue tests of flame cut edges in the laboratory indicated that fatigue life estimations based on the standard nominal stress method can give quite a conservative fatigue life estimate in cases where a high notch factor was present. This is an undesirable phenomenon and it limits the potential for minimizing structure size and total costs. A new calculation method is introduced to improve the accuracy of the theoretical fatigue life prediction method of a flame cut edge with a high stress concentration factor. Simple equations were derived by using laboratory fatigue test results, which are published in this work. The proposed method is called the modified FAT method (FATmod). The method takes into account the residual stress state, surface quality, material strength class and true stress ratio in the critical place.
Resumo:
Two engraved brass plates. The first plate is engraved with "Mr. and Mrs. Percy Carruthers Band, Hewlett, Long Island". The second plate is engraved with "Mr. and Mrs. Percy C. Band send best wishes for Christmas and the New Year".
Resumo:
Receipt from W.H. Glenny Sons and Co., Buffalo, New York for plates and cups, Nov. 30, 1886.