915 resultados para Physiological optics


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This cross-sectional study was designed to determine whether the academic performance of optometry undergraduates is influenced by enrolment status, learning style or gender. Methods: Three hundred and sixty undergraduates in all 3 years of the optometry degree course at Aston University during 2008–2009 were asked for their informed consent to participate in this study. Enrolment status was known from admissions records. An Index of Learning Styles (http://www4.nscu.edu/unity/lockers/users/f/felder/public/Learning-Styles.html) determined learning style preference with respect to four different learning style axes; active-reflective, sensing-intuitive, visual-verbal and sequential-global. The influence of these factors on academic performance was investigated. Results: Two hundred and seventy students agreed to take part (75% of the cohort). 63% of the sample was female. There were 213 home non-graduates (entrants from the UK or European Union without a bachelor’s degree or higher), 14 home graduates (entrants from the UK or European Union with a bachelor’s degree or higher), 28 international non-graduates (entrants from outside the UK or European Union without a bachelor’s degree or higher) and 15 international graduates (entrants from outside the UK or European Union with a bachelor’s degree or higher). The majority of students were balanced learners (between 48% and 64% across four learning style axes). Any preferences were towards active, sensing, visual and sequential learning styles. Of the factors investigated in this study, learning styles were influenced by gender; females expressed a disproportionate preference for the reflective and visual learning styles. Academic performance was influenced by enrolment status; international graduates (95% confidence limits: 64–72%) outperformed all other student groups (home non graduates, 60–62%; international non graduates, 55–63%) apart from home graduates (57–69%). Conclusion: Our research has shown that the majority of optometry students have balanced learning styles and, from the factors studied, academic performance is only influenced by enrolment status. Although learning style questionnaires offer suggestions on how to improve learning efficacy, our findings indicate that current teaching methods do not need to be altered to suit varying learning style preferences as balanced learning styles can easily adapt to any teaching style (Learning Styles and Pedagogy in Post-16 Learning: A Systematic and Critical Review. London, UK: Learning and Skills Research Centre, 2004).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose - Measurements obtained from the right and left eye of a subject are often correlated whereas many statistical tests assume observations in a sample are independent. Hence, data collected from both eyes cannot be combined without taking this correlation into account. Current practice is reviewed with reference to articles published in three optometry journals, viz., Ophthalmic and Physiological Optics (OPO), Optometry and Vision Science (OVS), Clinical and Experimental Optometry (CEO) during the period 2009–2012. Recent findings - Of the 230 articles reviewed, 148/230 (64%) obtained data from one eye and 82/230 (36%) from both eyes. Of the 148 one-eye articles, the right eye, left eye, a randomly selected eye, the better eye, the worse or diseased eye, or the dominant eye were all used as selection criteria. Of the 82 two-eye articles, the analysis utilized data from: (1) one eye only rejecting data from the adjacent eye, (2) both eyes separately, (3) both eyes taking into account the correlation between eyes, or (4) both eyes using one eye as a treated or diseased eye, the other acting as a control. In a proportion of studies, data were combined from both eyes without correction. Summary - It is suggested that: (1) investigators should consider whether it is advantageous to collect data from both eyes, (2) if one eye is studied and both are eligible, then it should be chosen at random, and (3) two-eye data can be analysed incorporating eyes as a ‘within subjects’ factor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose - Anterior segment optical coherent tomography (AS-OCT) is used to further examine previous reports that ciliary muscle thickness (CMT) is increased in myopic eyes. With reference to temporal and nasal CMT, interrelationships between biometric and morphological characteristics of anterior and posterior segments are analysed for British-White and British-South-Asian adults with and without myopia. Methods - Data are presented for the right eyes of 62 subjects (British-White n = 39, British-South-Asian n = 23, aged 18–40 years) with a range of refractive error (mean spherical error (MSE (D)) -1.74 ± 3.26; range -10.06 to +4.38) and separated into myopes (MSE (D) <-0.50, range -10.06 to -0.56; n = 30) and non-myopes (MSE (D) =-0.50, -0.50 to +4.38; n = 32). Temporal and nasal ciliary muscle cross-sections were imaged using a Visante AS-OCT. Using Visante software, manual measures of nasal and temporal CMT (NCMT and TCMT respectively) were taken in successive posterior 1 mm steps from the scleral spur over a 3 mm distance (designated NCMT1, TCMT1 et seq). Measures of axial length and anterior chamber depth were taken with an IOLMaster biometer. MSE and corneal curvature (CC) measurements were taken with a Shin-Nippon auto-refractor. Magnetic resonance imaging was used to determine total ocular volume (OV) for 31 of the original subject group. Statistical comparisons and analyses were made using mixed repeated measures anovas, Pearson's correlation coefficient and stepwise forward multiple linear regression. Results - MSE was significantly associated with CMT, with thicker CMT2 and CMT3 being found in the myopic eyes (p = 0.002). In non-myopic eyes TCMT1, TCMT2, NCMT1 and NCMT2 correlated significantly with MSE, AL and OV (p < 0.05). In contrast, myopic eyes failed generally to exhibit a significant correlation between CMT, MSE and axial length but notably retained a significant correlation between OV, TCMT2, TCMT3, NCMT2 and NCMT3 (p < 0.05). OV was found to be a significantly better predictor of TCMT2 and TCMT3 than AL by approximately a factor of two (p < 0.001). Anterior chamber depth was significantly associated with both temporal and nasal CMT2 and CMT3; TCMT1 correlated positively with CC. Ethnicity had no significant effect on differences in CMT. Conclusions - Increased CMT is associated with myopia. We speculate that the lack of correlation in myopic subjects between CMT and axial length, but not between CMT and OV, is evidence that disrupted feedback between the fovea and ciliary apparatus occurs in myopia development.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Guest editorial

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Changes in refractive error are well documented over the typical human lifespan. However, a relatively neglected period of investigation appears to be during the late fourth decade; this is at the incipient phase of presbyopia (IP), where the amplitude of accommodation is much reduced and approaches the level where a first reading addition is anticipated. Significantly, informal clinical observation has suggested a low incidence of an unexpected abrupt increase in myopia during IP. Methods: We investigated this alleged myopic shift retrospectively by mapping the longitudinal refraction histories of normally-sighted 35-44years old British White patients previously examined in routine optometric practice. The refractive trends in the right eyes of healthy myopic subjects (spherical equivalent refraction, SER =-0.50D: N=39) were analysed relative to that point at which a first near dioptric addition was considered to be clinically useful. Results: A refractive change was evident in some subjects during IP; viz, an abrupt increase in myopic SER of between -0.50 and -0.75D. These individuals (N=8) represented 20% of the study population of myopic incipient presbyopes. Beyond the pivotal point of the first near addition the longitudinal refraction stabilized in these subjects. In contrast, and as the extent of the available longitudinal data would permit, the remaining myopic eyes maintained an approximately stable refractive trend throughout IP and beyond. Conclusions: The anatomical or physiological basis of this specific late (non-developmental) abrupt myopic refractive change is an intriguing issue. Axial (vitreous chamber elongation), corneal (contour) and lenticular (profile and index) power bases, alone or in concert, might be considered candidates for this hitherto unexplored refractive phenomenon. Although necessarily obtained under conventional conditions of central (0deg) fixation, our data might also be a reflection of the recent recognition of the possible influence of the peripheral refraction upon the axial error. Consideration of this material provides an impetus for further research, including ocular biometry, a reappraisal of ciliary zonular functional anatomy, renewed investigation of the AC/A ratio, and the extent of a centripetal refractive influence on myopia development. © 2011 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the magnitude of nearwork-induced transient myopia (NITM) under binocular viewing conditions separately in each eye of individuals with mild to moderate anisometropia to determine the relationship between NITM and their interocular refractive error. Methods: Forty-three children and young adults with anisometropia [cycloplegic spherical equivalent (SE) difference >1.00 D] were tested (ages 9-28 years). NITM was measured with binocular viewing separately in each eye after binocularly performing a sustained near task (5 D) for 5 min incorporating a cognitive demand using an open-field, infrared autorefractor (Grand-Seiko, WAM-5500). Data were averaged over 10 s bins for 3 min in each eye. Initial NITM, its decay time (DT), and its decay area (DA) were determined. A-scan ultrasound ocular biometry was also performed to determine the axial length of each eye. Results: The more myopic eye exhibited increased initial NITM, DT, and DA as compared to the less myopic eye (0.21 ± 0.16 D vs 0.15 ± 0.13 D, p = 0.026; 108.4 ± 64.3 secs vs 87.0 ± 65.2 secs, p = 0.04; and 17.6 ± 18.7 D*secs vs 12.3 ± 15.7 D*secs, p = 0.064), respectively. The difference in DA and the difference in SE between the more versus less myopic eye were significantly correlated (r = 0.31, p = 0.044). Furthermore, 63% (27/43), 56% (24/43), and 70% (30/43) of the more myopic eyes exhibited increased initial NITM, longer DT, and larger DA, respectively, than found in the less myopic eye. Conclusions: In approximately two-thirds of the anisometropic individuals, the initial NITM and its decay area were significantly increased in the more myopic eye as compared to the less myopic eye. NITM may play an important role in the development of interocular differences in myopia, although a causal relationship is yet to be established. Furthermore, the findings have potentially important implications regarding accommodative control and interocular accommodative responsitivity in anisometropia, in particular for anisomyopia. © 2013 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: Contrast sensitivity (CS) provides important information on visual function. This study aimed to assess differences in clinical expediency of the CS increment-matched new back-lit and original paper versions of the Melbourne Edge Test (MET) to determine the CS of the visually impaired. Methods: The back-lit and paper MET were administered to 75 visually impaired subjects (28-97 years). Two versions of the back-lit MET acetates were used to match the CS increments with the paper-based MET. Measures of CS were repeated after 30 min and again in the presence of a focal light source directed onto the MET. Visual acuity was measured with a Bailey-Lovie chart and subjects rated how much difficulty they had with face and vehicle recognition. Results: The back-lit MET gave a significantly higher CS than the paper-based version (14.2 ± 4.1 dB vs 11.3 ± 4.3 dB, p < 0.001). A significantly higher reading resulted with repetition of the paper-based MET (by 1.0 ± 1.7 dB, p < 0.001), but this was not evident with the back-lit MET (by 0.1 ± 1.4 dB, p = 0.53). The MET readings were increased by a focal light source, in both the back-lit (by 0.3 ± 0.81, p < 0.01) and paper-based (1.2 ± 1.7, p < 0.001) versions. CS as measured by the back-lit and paper-based versions of the MET was significantly correlated to patients' perceived ability to recognise faces (r = 0.71, r = 0.85 respectively; p < 0.001) and vehicles (r = 0.67, r = 0.82 respectively; p < 0.001), and with distance visual acuity (both r =-0.64; p < 0.001). Conclusions: The CS increment-matched back-lit MET gives higher CS values than the old paper-based test by approximately 3 dB and is more repeatable and less affected by external light sources. Clinically, the MET score provides information on patient difficulties with visual tasks, such as recognising faces. © 2005 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: (1) To devise a model-based method for estimating the probabilities of binocular fusion, interocular suppression and diplopia from psychophysical judgements, (2) To map out the way fusion, suppression and diplopia vary with binocular disparity and blur of single edges shown to each eye, (3) To compare the binocular interactions found for edges of the same vs opposite contrast polarity. Methods: Test images were single, horizontal, Gaussian-blurred edges, with blur B = 1-32 min arc, and vertical disparity 0-8.B, shown for 200 ms. In the main experiment, observers reported whether they saw one central edge, one offset edge, or two edges. We argue that the relation between these three response categories and the three perceptual states (fusion, suppression, diplopia) is indirect and likely to be distorted by positional noise and criterion effects, and so we developed a descriptive, probabilistic model to estimate both the perceptual states and the noise/criterion parameters from the data. Results: (1) Using simulated data, we validated the model-based method by showing that it recovered fairly accurately the disparity ranges for fusion and suppression, (2) The disparity range for fusion (Panum's limit) increased greatly with blur, in line with previous studies. The disparity range for suppression was similar to the fusion limit at large blurs, but two or three times the fusion limit at small blurs. This meant that diplopia was much more prevalent at larger blurs, (3) Diplopia was much more frequent when the two edges had opposite contrast polarity. A formal comparison of models indicated that fusion occurs for same, but not opposite, polarities. Probability of suppression was greater for unequal contrasts, and it was always the lower-contrast edge that was suppressed. Conclusions: Our model-based data analysis offers a useful tool for probing binocular fusion and suppression psychophysically. The disparity range for fusion increased with edge blur but fell short of complete scale-invariance. The disparity range for suppression also increased with blur but was not close to scale-invariance. Single vision occurs through fusion, but also beyond the fusion range, through suppression. Thus suppression can serve as a mechanism for extending single vision to larger disparities, but mainly for sharper edges where the fusion range is small (5-10 min arc). For large blurs the fusion range is so much larger that no such extension may be needed. © 2014 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) is the leading cause of severe vision loss in the developed world. The lack of effective treatment modalities, coupled with evidence supporting an oxidative pathogenesis, has increased interest in the potential preventative role of nutritional supplementation. This article reviews seven randomised controlled trials (RCTs) that have investigated the role of nutritional supplementation in AMD. Three of these trials reported a positive effect of nutritional supplementation on AMD; the Age-related eye study (AREDS), the Lutein Antioxidant Supplementation Trial (LAST), and the oral zinc trial by Newsome et al. (1988). However, the oral zinc trial by Newsome et al. (1988) was unlikely to detect any difference between treatments smaller than 72%, and the AREDS results were based on a subgroup of their study population. Lutein was considered for the AREDS formulation, but was not commercially available at that time. The findings of the LAST support a possible therapeutic role of lutein in AMD. © 2004 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A clinical evaluation of the Shin-Nippon SRW-5000 (Japan), a newly released commercial autorefractor, was undertaken to assess its repeatability and validity compared to subjective refraction. Measurements of refractive error were performed on 200 eyes of 100 subjects (aged 24.4±8.0 years) subjectively (non-cycloplegic) by one optometrist and objectively with the SRW-5000 autorefractor by a second. Repeatability was assessed by examining the differences between the seven autorefractor readings taken from each eye and by re-measuring the objective prescription of 50 eyes at a subsequent session. Although the SRW-5000 read slightly more plus than subjective refraction (mean spherical equivalent +0.16±0.44D), it was found to be highly valid (accurate) compared to subjective refraction and repeatable over the prescription range of +6.50 to -15.00D examined. The Shin-Nippon SRW-5000 autorefractor is therefore a valuable complement to subjective refraction and as it offers the advantage of a binocular open field-of-view, has a great potential benefit for accommodation research studies. Copyright © 2001 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To determine whether curve-fitting analysis of the ranked segment distributions of topographic optic nerve head (ONH) parameters, derived using the Heidelberg Retina Tomograph (HRT), provide a more effective statistical descriptor to differentiate the normal from the glaucomatous ONH. Methods: The sample comprised of 22 normal control subjects (mean age 66.9 years; S.D. 7.8) and 22 glaucoma patients (mean age 72.1 years; S.D. 6.9) confirmed by reproducible visual field defects on the Humphrey Field Analyser. Three 10°-images of the ONH were obtained using the HRT. The mean topography image was determined and the HRT software was used to calculate the rim volume, rim area to disc area ratio, normalised rim area to disc area ratio and retinal nerve fibre cross-sectional area for each patient at 10°-sectoral intervals. The values were ranked in descending order, and each ranked-segment curve of ordered values was fitted using the least squares method. Results: There was no difference in disc area between the groups. The group mean cup-disc area ratio was significantly lower in the normal group (0.204 ± 0.16) compared with the glaucoma group (0.533 ± 0.083) (p < 0.001). The visual field indices, mean deviation and corrected pattern S.D., were significantly greater (p < 0.001) in the glaucoma group (-9.09 dB ± 3.3 and 7.91 ± 3.4, respectively) compared with the normal group (-0.15 dB ± 0.9 and 0.95 dB ± 0.8, respectively). Univariate linear regression provided the best overall fit to the ranked segment data. The equation parameters of the regression line manually applied to the normalised rim area-disc area and the rim area-disc area ratio data, correctly classified 100% of normal subjects and glaucoma patients. In this study sample, the regression analysis of ranked segment parameters method was more effective than conventional ranked segment analysis, in which glaucoma patients were misclassified in approximately 50% of cases. Further investigation in larger samples will enable the calculation of confidence intervals for normality. These reference standards will then need to be investigated for an independent sample to fully validate the technique. Conclusions: Using a curve-fitting approach to fit ranked segment curves retains information relating to the topographic nature of neural loss. Such methodology appears to overcome some of the deficiencies of conventional ranked segment analysis, and subject to validation in larger scale studies, may potentially be of clinical utility for detecting and monitoring glaucomatous damage. © 2007 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: Systemic hypertension is a silent killer that may have very few warning signs. This study examines detection and management of patients with cardiovascular disease (CVD) by optometrists in the UK. Method: A survey was sent out to 1402 optometrists who practice in the UK to investigate the nature and knowledge of detection of systemic hypertension. Results: The survey response rate was 37%. Optometrists were neutral to slightly positive towards the use of blood pressure (BP) monitors, but not on a routine basis. The most frequently asked question during history and symptoms concerned the patient's prescribed medication for systemic hypertension, and the least was that of specifying the last BP measurement. The additional test most widely used in the examination of the systemic hypertensive patient was direct ophthalmoscopy with red-free filter. Over one-tenth of optometric practices had a BP monitor, with automated devices being the most popular. Patients most likely to have their BP measured were suspect systemic hypertensives. Retinal haemorrhages are the most important finding in influencing an optometrist's referral criteria for suspected systemic hypertension. Conclusion: Although optometrists monitor the retina for signs of damage from systemic hypertension, further education in this important condition is warranted. © 2005 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The literature suggests that there may be pupil size and response abnormalities in migraine headache sufferers. We used an infra-red pupillometer to measure dynamic pupil responses to light in 20 migraine sufferers (during non-headache periods) and 16 non-migraine age and gender matched controls. There was a significant increase in the absolute inter-ocular difference of the latency of the pupil light response in the migraine group compared with the controls (0.062 s vs 0.025 s, p = 0.014). There was also a significant correlation between anisocoria and lateralisation of headache such that migraine sufferers with a habitual head pain side have more anisocoria (r= 0.59, p < 0.01), but this was not related to headache laterally. The pupil changes were not correlated with the interval since the last migraine headache, the severity of migraine headache or the number of migraine headaches per annum. We conclude that subtle sympathetic and parasympathetic pupil abnormalities persist in the inter-ictal phase of migraine. © 2005 The College of Optometrists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The Melbourne Edge Test (MET) is a portable forced-choice edge detection contrast sensitivity (CS) test. The original externally illuminated paper test has been superseded by a backlit version. The aim of this study was to establish normative values for age and to assess change with visual impairment. Method: The MET was administered to 168 people with normal vision (18-93 years old) and 93 patients with visual impairment (39-97 years old). Distance visual acuity (VA) was measured with a log MAR chart. Results: In those eyes without disease, MET CS was stable until the age of 50 years (23.8 ± .7 dB) after which it decreased at a rate of ≈1.5 dB per decade. Compared with normative values, people with low vision were found to have significantly reduced CS, which could not be totally accounted for by reduced VA. Conclusions: The MET provides a quick and easy measure of CS, which highlights a reduction in visual function that may not be detectable using VA measurements. © 2004 The College of Optometrists.