987 resultados para Phase angle


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Line-start permanent magnet motor (LSPMM) is a very attractive alternative to replace induction motors due to its very high efficiency and constant speed operation with load variations. However, designing this kind of hybrid motor is hard work and requires a good understanding of motor behavior. The calculation of load angle is an important step in motor design and can not be neglected. This paper uses the finite element method to show a simple methodology to calculate the load angle of a three-phase LSPMM combining the dynamic and steady-state simulations. The methodology is used to analyze a three-phase LSPMM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this work was to study the liquid crystalline structure of a nanodispersion delivery system intended to be used in photodynamic therapy after loading with photosensitizers (PSs) and additives such as preservatives and thickening polymers. Polarized light microscopy and light scattering were performed on a standard nanodispersion in order to determine the anisotropy of the liquid crystalline structure and the mean diameter of the nanoparticles, respectively. Small angle X-ray diffraction (SAXRD) was used to verify the influence of drug loading and additives on the liquid crystalline structure of the nanodispersions. The samples, before and after the addition of PSs and additives, were stable over 90 days, as verified by dynamic light scattering. SAXRD revealed that despite the alteration observed in some of the samples analyzed in the presence of photosensitizing drugs and additives, the hexagonal phase still remained in the crystalline phase. (C) 2011 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 100: 2849-2857, 2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose and demonstrate, theoretically and experimentally, a novel achromatic optical phase shifter modulator based on a frequency-domain optical delay line configured to maintain zero group delay as variable phase delay is generated by means of tilting a mirror. Compared with previously reported phase shifter modulators, e.g., based on the Pancharatnam (geometric) phase, our device is high speed and polarization insensitive and produces a large, bounded phase delay that, uniquely, is one-to-one mapped to a measurable parameter, the tilt angle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The combined approach of the molecular-kinetic and hydrodynamic theories for description of the motion of three-phase gas-liquid-solid contact lines has been examined using the Wilhelmy plate method. The whole dynamic meniscus has been divided into molecular, hydrodynamic, and static-like regions. The Young-Laplace equation and the molecular-kinetic and hydrodynamic dewetting theories have been applied to describe the meniscus profiles and contact angle. The dissipative forces accompanying the dynamic dewetting have also been investigated. The experiments with a Wilhelmy plate made from an acrylic polymer sheet were carried out using a computerized apparatus for contact angle analysis (OCA 20, DataPhysics, Germany). The extrapolated dynamic contact angle versus velocity of the three-phase contact line for Milli-Q water and 5 x 10(-4) M SDBS solution was experimentally obtained and compared with the combined MHD models with low and moderate Reynolds numbers. The models predict similar results for the extrapolated contact angle. SDBS decreases the equilibrium contact angle and increases the molecular jumping length but does not affect the molecular frequency significantly. The hydrodynamic deformation of the meniscus, viscous dissipation, and friction were also influenced by the SDBS surfactant. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inhomogeneities in the spatial distribution of the excitatory Radio Frequency (RF) field, are still a dominant source of artifacts and loss of signal to noise ratio in MR imaging experiments, A number of strategies have been proposed to quantify this distribution, However, in this technical note we present a relatively simple MR imaging procedure which can be used to visualise RF inhomogeneities directly either by means of the magnitude or the phase of an image. To visualise the RF field distribution in both the inner and outer volumes of the coil, we have performed experiments in which the entire coil is submerged in a non-conducting fluid, To the best of our knowledge this strategy has not been used previously in order to evaluate coil performance, Finally, we demonstrate that the method is sensitive enough to reveal the effects of the sample properties on the effective RF wavelength of the transmitted field. (C) 1997 Elsevier Science Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare the efficacy and tolerability of the fixed combination of timolol maleate 0.5%/brimonidine tartrate 0.2% versus fixed combination of timolol maleate 0.5%/dorzolamide 2% in patients with elevated intraocular pressure (IOP) over 8 weeks. Patients and Methods: This 8-week, multicentric. interventional, randomized, open-label, parallel group study was conducted Lit 4 centers in Brazil and 1 center in Argentina. Patients with open-angle glaucoma or ocular hypertension were randomized to receive bilaterally fixed combination of brimonidine/timolol maleate 0.5% or fixed combination of dorzolamide 2%/timolol 0.5% twice daily at 8:00 AM and 8:00 PM. A modified diurnal tension curve (8:00 AM 10:30 AM, 02:00 PM, and 4:00 PM) followed by the water drinking test (WDT), which estimates IOP peak of diurnal tension curve, were performed in the baseline and week-8 visits. Adverse events data were recorded at each visit. Results: A total of 210 patients were randomized (brimonidine/timolol, n = 111; dorzolamide/timolol, n = 99). Mean baseline IOP was 23.43 +/- 3.22 mm Hg and 23.43 +/- 4.06 mm Hg in the patients treated with brimonidine/timolol and dorzolamide/timolol, respectively (P = 0.993). Mean diurnal IOP reduction after 8 weeks were 7.02 +/- 3.06 mm Hg and 6.91 +/- 3.67 mm Hg. respectively (P = 0.811). The adjusted difference between groups (analysis of covariance) Lit week 8 was not statistically significant (P = 0.847). Mean baseline WDT peak was 27.79 +/- 4.29 mm Hg in the brimonidine/timolol group and 27.68 +/- 5.46 mm Hg in the dorzolamide/timolol group. After 8 weeks of treatment, mean WDT peaks were 20.94 +/- 3.76 mm Hg (P < 0.001) and 20.98 +/- 4.19 (P < 0.001), respectively. The adjusted difference between groups (analysis of covariance) was not statistically significant (P = 0.469). No statistical difference in terms of adverse events was Found between groups. Conclusions: Both fixed combinations were capable of significantly reducing the mean diurnal IOP, mean diurnal peak, and mean WDT peak after 8 weeks of treatment. Also, both fixed combinations are well tolerated with few side effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organic microcavity light-emitting diodes typically exhibit a blueshift of the emitting wavelength with increasing viewing angle. We have modeled the shift of the resonance wavelength for several metal mirrors. Eight metals (Al, Ag, Cr, Ti, Au, Ni, Pt, and Cu) have been considered as top or bottom mirrors, depending on their work functions. The model fully takes into account the dependence of the phase change that occurs on reflection on angle and wavelength for both s and p polarization, as well as on dispersion in the organic layers. Different contributions to the emission wavelength shift are discussed. The influence of the thickness of the bottom mirror and of the choice and thickness of the organic materials inside the cavity has been investigated. Based on the results obtained, guidelines for a choice of materials to reduce blueshift; are given. (C) 2002 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the structural and thermodynamic properties of a model of particles with 2 patches of type A and 10 patches of type B. Particles are placed on the sites of a face centered cubic lattice with the patches oriented along the nearest neighbor directions. The competition between the self- assembly of chains, rings, and networks on the phase diagram is investigated by carrying out a systematic investigation of this class of models, using an extension ofWertheim's theory for associating fluids and Monte Carlo numerical simulations. We varied the ratio r epsilon(AB)/epsilon(AA) of the interaction between patches A and B, epsilon(AB), and between A patches, epsilon(AA) (epsilon(BB) is set to theta) as well as the relative position of the A patches, i.e., the angle. between the (lattice) directions of the A patches. We found that both r and theta (60 degrees, 90 degrees, or 120 degrees) have a profound effect on the phase diagram. In the empty fluid regime (r < 1/2) the phase diagram is reentrant with a closed miscibility loop. The region around the lower critical point exhibits unusual structural and thermodynamic behavior determined by the presence of relatively short rings. The agreement between the results of theory and simulation is excellent for theta = 120 degrees but deteriorates as. decreases, revealing the need for new theoretical approaches to describe the structure and thermodynamics of systems dominated by small rings. (C) 2014 AIP Publishing LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: Hamstrings strains are common and debilitating injuries in many sports. Most hamstrings exercises are performed at an inadequately low hip-flexion angle because this angle surpasses 70° at the end of the sprinting leg's swing phase, when most injuries occur. OBJECTIVE: To evaluate the influence of various hip-flexion angles on peak torques of knee flexors in isometric, concentric, and eccentric contractions and on the hamstrings-to-quadriceps ratio. DESIGN: Descriptive laboratory study. SETTING: Research laboratory. Patients and Other Participants: Ten national-level sprinters (5 men, 5 women; age = 21.2 ± 3.6 years, height = 175 ± 6 cm, mass = 63.8 ± 9.9 kg). Intervention(s): For each hip position (0°, 30°, 60°, and 90° of flexion), participants used the right leg to perform (1) 5 seconds of maximal isometric hamstrings contraction at 45° of knee flexion, (2) 5 maximal concentric knee flexion-extensions at 60° per second, (3) 5 maximal eccentric knee flexion-extensions at 60° per second, and (4) 5 maximal eccentric knee flexionextensions at 150° per second. Main Outcome Measure(s): Hamstrings and quadriceps peak torque, hamstrings-to-quadriceps ratio, lateral and medial hamstrings root mean square. RESULTS: We found no difference in quadriceps peak torque for any condition across all hip-flexion angles, whereas hamstrings peak torque was lower at 0° of hip flexion than at any other angle (P < .001) and greater at 90° of hip flexion than at 30° and 60° (P < .05), especially in eccentric conditions. As hip flexion increased, the hamstrings-to-quadriceps ratio increased. No difference in lateral or medial hamstrings root mean square was found for any condition across all hip-flexion angles (P > .05). CONCLUSIONS: Hip-flexion angle influenced hamstrings peak torque in all muscular contraction types; as hip flexion increased, hamstrings peak torque increased. Researchers should investigate further whether an eccentric resistance training program at sprint-specific hip-flexion angles (70° to 80°) could help prevent hamstrings injuries in sprinters. Moreover, hamstrings-to-quadriceps ratio assessment should be standardized at 80° of hip flexion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present strategies for chemical shift assignments of large proteins by magic-angle spinning solid-state NMR, using the 21-kDa disulfide-bond-forming enzyme DsbA as prototype. Previous studies have demonstrated that complete de novo assignments are possible for proteins up to approximately 17 kDa, and partial assignments have been performed for several larger proteins. Here we show that combinations of isotopic labeling strategies, high field correlation spectroscopy, and three-dimensional (3D) and four-dimensional (4D) backbone correlation experiments yield highly confident assignments for more than 90% of backbone resonances in DsbA. Samples were prepared as nanocrystalline precipitates by a dialysis procedure, resulting in heterogeneous linewidths below 0.2 ppm. Thus, high magnetic fields, selective decoupling pulse sequences, and sparse isotopic labeling all improved spectral resolution. Assignments by amino acid type were facilitated by particular combinations of pulse sequences and isotopic labeling; for example, transferred echo double resonance experiments enhanced sensitivity for Pro and Gly residues; [2-(13)C]glycerol labeling clarified Val, Ile, and Leu assignments; in-phase anti-phase correlation spectra enabled interpretation of otherwise crowded Glx/Asx side-chain regions; and 3D NCACX experiments on [2-(13)C]glycerol samples provided unique sets of aromatic (Phe, Tyr, and Trp) correlations. Together with high-sensitivity CANCOCA 4D experiments and CANCOCX 3D experiments, unambiguous backbone walks could be performed throughout the majority of the sequence. At 189 residues, DsbA represents the largest monomeric unit for which essentially complete solid-state NMR assignments have so far been achieved. These results will facilitate studies of nanocrystalline DsbA structure and dynamics and will enable analysis of its 41-kDa covalent complex with the membrane protein DsbB, for which we demonstrate a high-resolution two-dimensional (13)C-(13)C spectrum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Until recently, the hard X-ray, phase-sensitive imaging technique called grating interferometry was thought to provide information only in real space. However, by utilizing an alternative approach to data analysis we demonstrated that the angular resolved ultra-small angle X-ray scattering distribution can be retrieved from experimental data. Thus, reciprocal space information is accessible by grating interferometry in addition to real space. Naturally, the quality of the retrieved data strongly depends on the performance of the employed analysis procedure, which involves deconvolution of periodic and noisy data in this context. The aim of this article is to compare several deconvolution algorithms to retrieve the ultra-small angle X-ray scattering distribution in grating interferometry. We quantitatively compare the performance of three deconvolution procedures (i.e., Wiener, iterative Wiener and Lucy-Richardson) in case of realistically modeled, noisy and periodic input data. The simulations showed that the algorithm of Lucy-Richardson is the more reliable and more efficient as a function of the characteristics of the signals in the given context. The availability of a reliable data analysis procedure is essential for future developments in grating interferometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the depinning transition occurring in dislocation assemblies. In particular, we consider the cases of regularly spaced pileups and low-angle grain boundaries interacting with a disordered stress landscape provided by solute atoms, or by other immobile dislocations present in nonactive slip systems. Using linear elasticity, we compute the stress originated by small deformations of these assemblies and the corresponding energy cost in two and three dimensions. Contrary to the case of isolated dislocation lines, which are usually approximated as elastic strings with an effective line tension, the deformations of a dislocation assembly cannot be described by local elastic interactions with a constant tension or stiffness. A nonlocal elastic kernel results as a consequence of long-range interactions between dislocations. In light of this result, we revise statistical depinning theories of dislocation assemblies and compare the theoretical results with numerical simulations and experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray imaging with grating interferometry has previously been regarded as a technique providing information only in direct space. It delivers absorption, phase, and dark-field contrast, which can be viewed as parameters of the underlying but unresolved scattering distribution. Here, we present a method that provides the ultrasmall-angle x-ray scattering distribution and, thus, allows simultaneous access to direct and reciprocal space information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Guex, KJ, Lugrin, V, Borloz, S, and Millet, GP. Influence on strength and flexibility of a swing phase-specific hamstring eccentric program in sprinters' general preparation. J Strength Cond Res 30(2): 525-532, 2016-Hamstring injuries are common in sprinters and mainly occur during the terminal swing phase. Eccentric training has been shown to reduce hamstring injury rate by improving several risk factors. The aim of this study was to test the hypothesis that an additional swing phase-specific hamstring eccentric training in well-trained sprinters performed at the commencement of the winter preparation is more efficient to improve strength, ratio, optimum angle, and flexibility than a similar program without hamstring eccentric exercises. Twenty sprinters were randomly allocated to an eccentric (n = 10) or a control group (n = 10). Both groups performed their usual track and field training throughout the study period. Sprinters in the eccentric group performed an additional 6-week hamstring eccentric program, which was specific to the swing phase of the running cycle (eccentric high-load open-chain kinetic movements covering the whole hamstring length-tension relationship preformed at slow to moderate velocity). Isokinetic and flexibility measurements were performed before and after the intervention. The eccentric group increased hamstring peak torques in concentric at 60 degrees .s by 16% (p < 0.001) and at 240 degrees .s by 10% (p < 0.01), in eccentric at 30 degrees .s by 20% (p < 0.001) and at 120 degrees .s by 22% (p < 0.001), conventional and functional ratios by 12% (p < 0.001), and flexibility by 4 degrees (p < 0.01), whereas the control group increased hamstring peak torques only in eccentric at 30 degrees .s by 6% (p </= 0.05) and at 120 degrees .s by 6% (p < 0.01). It was concluded that an additional swing phase-specific hamstring eccentric training in sprinters seems to be crucial to address different risk factors for hamstring strain injuries, such as eccentric and concentric strength, hamstring-to-quadriceps ratio ratio, and flexibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le glaucome est la seconde cause de cécité dans le monde après la cataracte et est caractérisé par la perte progressive de cellules ganglionnaires de la rétine allant vers la dégénérescence du nerf optique. On distingue deux formes de glaucome; le glaucome à angle fermé et le glaucome à angle ouvert. L'hérédité du glaucome est souvent sporadique, parfois autosomique dominante. Une pression intraoculaire de plus de 21 mmHg représente un facteur de risque important pour son développement. Actuellement, la mutation la plus fréquente, observée dans 5% des cas de glaucome héréditaire, est retrouvée dans le gène MYOC (trabecular meshwork inducible glucocorticoide response). À ce jour, les causes et mécanismes moléculaires sous-jacent ne sont que partiellement compris. Récemment, il a été démontré qu'une souris transgénique exprimant le gène Notch2 dans luvée, développait un glaucome. Pour cette raison, nous avons analysé le gène NOTCH2 chez l'homme afin de déterminer s'il était impliqué. NOTCH2 est composé de 34 exons sur le chromosome 1 et code une protéine transmembranaire essentielle à la prolifération, l'apoptose, la différenciation cellulaire et le destin cellulaires. L'expression du gène est localisée dans le segment antérieur de l'oeil, le segment externe du corps ciliaire et le trabéculum. Les fonctions principales de ces deux tissus sont la production et le drainage de l'humeur aqueuse. Pour mémoire, une perturbation du flux peut générer une augmentation de la pression intraoculaire. Le but de cette étude était de rechercher d'éventuelles mutations du gène NOTCH2 chez des patients souffrant de glaucome. 130 patients ont été vu à l'hôpital ophtalmique Jules- Gonin et un échantillon d'ADN a été récolté afin d'identifier l'origine moléculaire de leur pathologie. L'analyse moléculaire s'est fait étape par étape. Premièrement, j'ai séquencé l'exon 3 du gène MYOC. Deuxièment, la Chromatographie en phase liquide à haute performance a été utilisée pour l'analyse des 34 exons du gène NOTCH2. Troisièment, tous les exons présentant une courbe suspecte au chromatogramme ont été séquencés selon la méthode de Sanger. Dans la première partie de l'étude, j'ai analysé l'exon 3 du gène MYOC afin de déterminer les éventuels porteurs d'une mutation dominante. Aucune mutation pathogénique n'a été mis en évidence mais 4 patients sur les 130 étaient porteurs d'un variant connu et fréquent. Dans la deuxième partie de mon étude, j'ai analysé les 34 exons du gène NOTCH2, qui n'ont révélé aucune mutation. Bien que les méthodes utilisées dans cette étude montrent quelques limitations, il est peu probable que des mutations dans les régions codantes de NOTCH2 soient un facteur de risque important dans le glaucome primaire à angle ouvert.