621 resultados para Peixos marins


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manuscript presents three approaches : analytical, experimental and numerical, to study the behaviour of a flexible membrane tidal energy converter. This technology, developed by the EEL Energy company, is based on periodic deformations of a pre-stressed flexible structure. Energy converters, located on each side of the device, are set into motion by the wave-like motion. In the analytical model, the membrane is represented by a linear beam model at one dimension and the flow by a 3 dimensions potential fluid. The fluid forces are evaluated by the elongated body theory. Energy is dissipated all over the length of the membrane. A 20th scale experimental prototype has been designed with micro-dampers to simulate the power take-off. Trials have allowed to validate the undulating membrane energy converter concept. A numerical model has been developed. Each element of the device is represented and the energy dissipation is done by dampers element with a damping law linear to damper velocity. Comparison of the three approaches validates their ability to represent the membrane behaviour without damping. The energy dissipation applied with the analytical model is clearly different from the two other models because of the location (where the energy is dissipated) and damping law. The two others show a similar behaviour and the same order of power take off repartition but value of power take off are underestimated by the numerical model. This three approaches have allowed to put forward key-parameters on which depend the behaviour of the membrane and the parametric study highlights the complementarity and the advantage of developing three approaches in parallel to answer industrial optimization problems. To make the link between trials in flume tank and sea trials, a 1/6th prototype has been built. To do so, the change of scale was studied. The behaviour of both prototypes is compared and differences could be explained by differences of boundary conditions and confinement effects. To evaluated membrane long-term behaviour at sea, a method of ageing accelerated by temperature and fatigue tests have been carried out on prototype materials samples submerged in sea water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Hipertensão Arterial Sistêmica é uma doença crônica e cada dia é diagnosticado uma quantidade maior de pacientes ao nível mundial. Com alta morbidade e mortalidade. O problema maior é a falta de conhecimento da população para prevenir a doença ou suas complicações em pacientes já doentes. Em nossa área de abrangência a maior quantidade de pacientes doentes registrados é hipertensa. Os níveis de vida da população, com baixos ingressos econômicos e situações cotidianas negativas favorecem a exposição a estresse constante e desestabilizam a família e as pessoas mais vulneráveis, condicionando a aparição de cifras elevadas de PA. O sedentarismo, o alcoolismo, o consumo de drogas, o habito de fumar, os péssimos hábitos alimentares constituem fatores de risco sempre presentes na população atendida. Este trabalho propõe elevar o nível de conhecimento sobre a hipertensão em pacientes, familiares e grupos de risco, para poder diminuir as complicações desta doença. Para isso nossa equipe dividiu o trabalho em três momentos, no primeiro momento aplica-se um questionário que conterá perguntas de múltipla escolha, com apenas uma resposta correta e participarão os pacientes que estiverem sendo acompanhado pela equipe durante a investigação, os familiares q aceitarem participar e pacientes em risco. No segundo momento se realizarão atividades educativas para logo aplicar o mesmo questionário e comprovar o aprendido. Esperamos que este projeto pudesse ajudar a nossos pacientes e contribuir positivamente a melhorar os indicadores de morbimortalidade por Hipertensão Arterial nesta área de saúde, onde esta doença é a de maior prevalência.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to test the feasibility and reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) evaluations of the fetal brains in cases of twin-twin transfusion syndrome (TTTS). From May 2011 to June 2012, 24 patients with severe TTTS underwent MRI scans for evaluation of the fetal brains. Datasets were analyzed offline on axial DW images and apparent diffusion coefficient (ADC) maps by two radiologists. The subjective evaluation was described as the absence or presence of water diffusion restriction. The objective evaluation was performed by the placement of 20-mm(2) circular regions of interest on the DW image and ADC maps. Subjective interobserver agreement was assessed by the kappa correlation coefficient. Objective intraobserver and interobserver agreements were assessed by proportionate Bland-Altman tests. Seventy-four DW-MRI scans were performed. Sixty of them (81.1%) were considered to be of good quality. Agreement between the radiologists was 100% for the absence or presence of diffusion restriction of water. For both intraobserver and interobserver agreement of ADC measurements, proportionate Bland-Altman tests showed average percentage differences of less than 1.5% and 95% CI of less than 18% for all sites evaluated. Our data demonstrate that DW-MRI evaluation of the fetal brain in TTTS is feasible and reproducible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the caries prevalence, saliva buffering capacity (SBC), oral hygiene (OH), dietary habits, family income (FI) and frequency of visits to a dental office (Do) between Brazilian children living in areas with and without fluoridated public water supply. METHODS: Forty-six 5-7-year-old preschoolers were selected in Itatiba, SP, Brazil; 19 were from a fluoridated area, and 27 were from a non-fluoridated area. The caries index was determined according to the World Health Organization criteria, and the SBC was assessed by titration with hydrochloric acid. The FI, frequency of OH and visits to Do were estimated by questionnaire. The dietary habits were assessed with a diet chart. The differences between the groups were analyzed with Mann-Whitney-U tests (α=0.05). RESULTS: Children from the non-fluoridated area showed significantly higher dmft/DMFT than those from the fluoridated area, but they showed significantly lower SBC, OH frequency and FI. No significant differences were observed between the areas for dietary habits and visits to Do. CONCLUSION: Children from fluoridated areas showed higher salivary buffering capacity, family income and oral hygiene frequency as well as lower caries prevalence, supporting the beneficial effect of fluoride in the tap water for caries prevention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The k(0)-method instrumental neutron activation analysis (k(0)-INAA) was employed for determining chemical elements in bird feathers. A collection was obtained taking into account several bird species from wet ecosystems in diverse regions of Brazil. For comparison reason, feathers were actively sampled in a riparian forest from the Marins Stream, Piracicaba, Sao Paulo State, using mist nets specific for capturing birds. Biological certified reference materials were used for assessing the quality of analytical procedure. Quantification of chemical elements was performed using the k(0)-INAA Quantu Software. Sixteen chemical elements, including macro and micronutrients, and trace elements, have been quantified in feathers, in which analytical uncertainties varied from 2% to 40% depending on the chemical element mass fraction. Results indicated high mass fractions of Br (max=7.9 mgkg(-1)), Co (max= 0.47 mg kg(-1)), Cr (max =68 mg kg(-1)), Hg (max =2.79 mg kg(-1)), Sb (max= 0.20 mg kg(-1)), Se (max=1.3 mg kg(-1)) and Zn (max =192 mg kg(-1)) in bird feathers, probably associated with the degree of pollution of the areas evaluated. In order to corroborate the use of k(0)-INAA results in biomonitoring studies using avian community, different factor analysis methods were used to check chemical element source apportionment and locality clustering based on feather chemical composition. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The inorganic chemical characterization of suspended sediments is of utmost relevance for the knowledge of the dynamics and movement of chemical elements in the aquatic and wet ecosystems. Despite the complexity of the effective design for studying this ecological compartment, this work has tested a procedure for analyzing suspended sediments by instrumental neutron activation analysis, k(0) method (k(0)-INAA). The chemical elements As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, Fig, K, La, Mo, Na, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, Yb and Zn were quantified in the suspended sediment compartment by means of k(0)-INAA. When compared with World Average for rivers, high mass fractions of Fe (222,900 mg/kg), Ba (4990 mg/kg), Zn (1350 mg/kg), Cr (646 mg/kg), Co (74.5 mg/kg), Br (113 mg/kg) and Mo (31.9 mg/kg) were quantified in suspended sediments from the Piracicaba River, the Piracicamirim Stream and the Marins Stream. Results of the principal component analysis for standardized chemical element mass fractions indicated an intricate correlation among chemical elements evaluated, as a response of the contribution of natural and anthropogenic sources of chemical elements for ecosystems. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Silastic rings are used in gastric bypass procedures for the treatment of obesity, but ring slippage may lead to gastric pouch outlet stenosis (GPOS). Conventional management has been ring removal through abdominal surgery. Objective: To describe a novel, safe, minimally invasive, endoscopic technique for the treatment of GPOS caused by ring slippage after gastric bypass. Design: Case series. Setting: Federal University of Pernambuco and sao Paulo University. Patients: This study involved 39 consecutive patients who-were screened for inclusion. Intervention: Endoscopic dilation with an achalasia balloon. Main Outcome Measurements: Technical success and safety of the procedure. Results: Among the 39 patients, 35 underwent endoscopic dilation at the ring slippage site for the relief of GPOS. The 4 patients who did not undergo endoscopic dilation underwent surgical removal of the ring, based on the exclusion criteria. The endoscopic approach was successful in 1 to 4 sessions in 100% of cases with radioscopic control (n = 12). The duration of the procedures ranged from 5 to 30 minutes, and the average internment was 14.4 hours. Dilation promoted either rupture (65.7%) or stretching (34.3%) of the thread within the ring, thereby increasing the luminal diameter of the GPOS. Complications included self-limited upper digestive tract hemorrhage (n = 1) and asymptomatic ring erosion (n = 4). There were no recurrences of obstructive symptoms during the follow-up period (mean of 33.3 months). Limitations: This was not a randomized, comparison study, and the number of patients was relatively small. Conclusion: The technique described promotes the relief of GPOS with low overall morbidity and avoids abdominal reoperation for ring removal. (Gastrointest Endosc 2010;72:44-9.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Steroidogenic factor 1 (SF-1) is a key determinant of endocrine development and function of adrenal cortex. SF-1 overexpression and gene amplification were previously demonstrated in a small group of pediatric adrenocortical tumors. Objective: Our objective was to determine the frequency of SF-1 protein expression and gene amplification in a large cohort of pediatric and adult adrenocortical tumors. Patients: SF-1 protein expression was assessed in a cohort of 103 adrenocortical tumors from 36 children and 67 adults, whereas gene amplification was studied in 38 adrenocortical tumors ( 17 from children). Methods: Tissue microarray, multiplex ligation-dependent probe amplification, and quantitative real-time PCR were used. Results: Astrong nuclear SF-1 expression was detected by tissue microarray in 56% (20 of 36) and 19% (13 of 67) of the pediatric and adult adrenocortical tumors, respectively (P = 0.0004). Increased SF-1 copy number was identified in 47% (eight of 17) and 10% (two of 21) of the pediatric and adult adrenocortical tumors, respectively (P = 0.02). All adrenocortical tumors with SF-1 gene amplification showed a strong SF-1 staining, whereas most of the tumors (61%) without SF-1 amplification displayed a weak or negative staining (P = 0.0008). Interestingly, a strong SF-1 staining was identified in five (29%) pediatric adrenocortical tumors without SF-1 amplification. The frequency of SF-1 overexpression and gene amplification was similar in adrenocortical adenomas and carcinomas. Conclusion: We demonstrated a higher frequency of SF-1 overexpression and gene amplification in pediatric than in adult adrenocortical tumors, suggesting an important role of SF-1 in pediatric adrenocortical tumorigenesis. (J Clin Endocrinol Metab 95: 1458-1462, 2010)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. The purpose of this study was to evaluate how curing protocol affects the extent of polymerization of dual-cured resin cements. Methods. Four commercial resin cements were used (DuoLink, Panavia F 2.0, Variolink II and Enforce). The extent of polymerization of the resin cements cured under different conditions was measured using a (1)H Stray-Field MRI method, which also enabled to probe molecular mobility in the kHz frequency range. Results. Resin cements show well distinct behaviours concerning chemical cure. Immediate photo-activation appears to be the best choice for higher filler loaded resin cements (Panavia F 2.0 and Variolink). A photo-activation delay (5 min) did not induce any significant difference in the extent of polymerization of all cements. Significance. The extent of polymerization of dual-cured resin cements considerably changed among products under various curing protocols. Clinicians should optimize the materials choice taking into account the curing characteristics of the cements. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To analyze the microhardness of four dual-cure resin cements used for cementing fiber-reinforced posts under the following conditions: after 7 days of storage in water, after additional 24 h of immersion in 75% ethanol, and after 3 months of storage in water. Hardness measurements were taken at the cervical, middle and apical thirds along the cement line. Methods. Root canals of 40 bovine incisors were prepared for post space. Fibrekor (R) glass fiber-reinforced posts (Jeneric/Pentron) of 1 mm in diameter were cemented using Panavia F 2.0 (Kuraray), Variolink (Ivoclar-Vivadent), Rely X Unicem (3M ESPE) or Duolink (Bisco) (N = 10). After 7 days of water storage at 37 degrees C, half the sample (N = 5) was longitudinally sectioned and the initial microhardness measured along the cement line from cervical to apex. These same samples were further immersed in 75% ethanol for 24 h and reassessed. The remaining half (N = 5) was kept unsectioned in deionized water at 37 degrees C for 3 months, followed by sectioning and measuring. Data were analyzed by a series of two-way ANOVA and Tukey tests at alpha = 5%. Results. Statistically significant differences were identified among the cements, thirds and conditions. Significant interactions were also observed between cements and thirds and between cements and conditions. Panavia F exhibited significantly higher initial microhardness than the other three cements, which showed no statistical difference among themselves. Variolink and Duolink showed significantly higher microhardness values in the cervical third, without significant difference among the thirds for the other cements. Immersion in ethanol significantly reduced the hardness values for all cements, regardless of the thirds. Storage in water for 3 months had no influence on the hardness of most of the cements, with the exception of Unicem that showed a significant increase in the hardness values after this period. Results showed heterogeneity in the microhardness of the cements inside the canal. All cements presented some degree of softening after ethanol treatment, which suggests instability of the polymer. The quality of curing of resin cements in the root canal environment seems unpredictable and highly material dependent. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the cytotoxic effects of resin-based light-cured liners on culture of pulp cells. Methods: Discs measuring 4 mill in diameter and 2 mm thick were fabricated from TheraCal (TCMTA), Vitrebond (VIT), and Ultrablend Plus (UBP). These specimens were immersed in serum-free culture medium (DMEM) for 24 hours or 7 days to produce the extracts. After incubating the pulp cells for 72 hours, the extracts were applied on the cells and the cytotoxic effects were determined based on the cell metabolism (MTT), total protein expression and cell morphology (SEM). In the control group, fresh DMEM was used. Data from MTT analysis and protein expression were submitted to Kruskal-Wallis and Mann-Whitney tests at the preset level of significance of 5%. Results: When in contact with the 24-hour extract, TCMTA, VIT, and UBP decreased the cell metabolism by 31.5%, 73.5% and 71.0%, respectively. The total protein expressed by the cells in contact with VIT and UBP was lower than TCMTA and DMEM (Mann-Whitney, P< 0.05). When in contact with the 7-day extract, TCMTA, VIT, and UBP decreased the metabolic activity by 45.9%, 77.1% and 64.4%, respectively. All the liners expressed statistically lower amounts of proteins when compared to the control. A reduction in the number of cells was observed for all liners. The remaining cells from TCMTA group resembled those from the control group while for VIT and UBP the cells presented significant morphological alterations. (Ani J Dent 2009;22:137-142).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose This 24-month randomized paired tooth clinical study evaluated the performance of All Bond 3 used in the simplified (2-step) and full (3-step) versions Methods 33 patients, with at least two similar sized non-carious cervical lesions participated in this study A total of 66 restorations were placed, half using the 2-step All Bond 3 (AB3-2) and the other half using 3-step All Bond 3 (AB3-3) The restorations were placed incrementally using the composite resin Aelite The restorations were evaluated at baseline and after 6, 12 and 24 months following the modified USPHS criteria Statistical differences between the adhesive were tested using with McNemar`s test and clinical performance over time for each material with the Fisher`s exact test (alpha= 0 05) Results After 24 months, six AB3-2 and four AB3-3 were rated as bravo for marginal discoloration but did not differ from each other significantly (P> 0 05) The retention rates at 24 months of AB3-2 and AB3-3 were 90 9% and 97 0%, respectively (P> 0 05) (Am J Dent 2010,23 231-236)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work contains the theoretical simulation of the conformation of diphenyl-4-amine sodium sulphonate (DASNa) and correlates its geometry with conductivity, showing that the conductivity increases as the molecule becomes more planar. The solvent effect was also evaluated, using water and dimethylsulfoxide. Some properties, such as bond distance, vibration al frequency and effective charge were calculated. The utilization of diphenyl-4-amine sodium sulphonate (DASNa) as dopant of aniline was investigated in view of the HOMO-LUMO energy gap.