992 resultados para Particulate matter concentrations
Resumo:
I have developed a novel approach to test for toxic organic substances adsorbed onto ultra fine particulate particles present in the ambient air in Northeast Houston, Texas. These particles are predominantly carbon soot with an aerodynamic diameter (AD) of <2.5 μm. If present in the ambient air, many of the organic substances will be absorbed to the surface of the particles (which act just like a charcoal air filter), and may be adducted into the respiratory system. Once imbedded into the lungs these particles may release the adsorbed toxic organic substances with serious health consequences. I used a Airmetrics portable Minivol air sampler time drawing the ambient air through collection filters samples from 6 separate sites in Northeast Houston, an area known for high ambient PM 2.5 released from chemical plants and other sources (e.g. vehicle emissions).(1) In practice, the mass of the collected particles were much less than the mass of the filters. My technique was designed to release the adsorbed organic substances on the fine carbon particles by heating the filter samples that included the PM 2.5 particles prior to identification by gas chromatography/mass spectrometry (GCMS). The results showed negligible amounts of target chemicals from the collection filters. However, the filters alone released organic substances and GCMS could not distinguish between the organic substances released from the soot particles from those released from the heated filter fabric. However, an efficacy tests of my method using two wax burning candles that released soot revealed high levels of benzene. This suggests that my method has the potential to reveal the organic substances adsorbed onto the PM 2.5 for analysis. In order to achieve this goal, I must refine the particle collection process which would be independent of the filters; the filters upon heating also release organic substances obscuring the contribution from the soot particles. To obtain pure soot particles I will have to filter more air so that the soot particles can be shaken off the filters and then analyzed by my new technique. ^
Resumo:
Background. Research has shown that elevations of only 10 mmHg diastolic blood pressure (BP) and 5 mmHg systolic BP are associated with substantial (as large as 50%) increases in risks for cardiovascular disease, a leading cause of death, worldwide. Epidemiological studies have found that particulate matter (PM) increases blood pressure (BP) and many biological mechanisms which may suggest that the organic matter of PM contributes to the increase in BP. To understand components of PM which may contribute to the increase in BP, this study focuses on diesel particulate matter (DPM) and polycyclic aromatic hydrocarbons (PAHs). To our knowledge, there have been only four epidemiological studies on BP and DPM, and no epidemiological studies on BP and PAHs. ^ Objective. Our objective was to evaluate the association between prevalent hypertension and two ambient exposures: DPM and PAHs amongst the Mano a Mano cohort. ^ Methods. The Mano a Mano cohort which was established by the M.D. Anderson Cancer Center in 2001, is comprised of individuals of Mexican origin residing in Houston, TX. Using geographical information systems, we linked modeled annual estimates of PAHs and DPM at the census track level from the U.S. Environmental Protection Agency's National-Scale Air Toxics Assessment to residential addresses of cohort members. Mixed-effects logistic regression models were applied to determine associations between DPM and PAHs and hypertension while adjusting for confounders. ^ Results. Ambient levels of DPM, categorized into quartiles, were not statistically associated with hypertension and did not indicate a dose response relationship. Ambient levels of PAHs, categorized into quartiles, were not associated with hypertension, but did indicate a dose response relationship in multiple models (for example: Q2: OR = 0.98; 95% CI, 0.73–1.31, Q3: OR = 1.08; 95% CI, 0.82–1.41, Q4: OR = 1.26; 95% CI, 0.94–1.70). ^ Conclusion. This is the first assessment to analyze the relationship between ambient levels of PAHs and hypertension and it is amongst a few studies investigating the association between ambient levels of DPM and hypertension. Future analyses are warranted to explore the effects DPM and PAHs using different categorizations in order to clarify their relationships with hypertension.^
Resumo:
This study represents a secondary analysis of the merging of emergency room visits and daily ozone and PM2.5. Although the adverse health effects of ozone and fine particulate matter have been documented in the literature, evidence regarding the health risks of these two pollutants in Harris County, Texas, is limited. Harris County (Houston) has sufficiently unique characteristics that analysis of these relationships in this setting and with the ozone and industry issues in Houston is informative. The objective of this study was to investigate the association between the joint exposure to ozone and fine particulate matter, and emergency room diagnoses of chronic obstructive pulmonary disease and cardiovascular disease in Harris County, Texas, from 2004 to 2009, with zero and one day lags. ^ The study variables were daily emergency room visits for Harris County, Texas, from 2004 to 2009, temperature, relative humidity, east wind component, north wind component, ozone, and fine particulate matter. Information about each patient's age, race, and gender was also included. The two dichotomous outcomes were emergency room visits diagnoses for chronic obstructive pulmonary disease and cardiovascular disease. Estimates of ozone and PM2.5 were interpolated using kriging, in which estimates of the two pollutants were predicted from monitoring data for every case residence zip code for every day of the six years, over 3 million estimates (one of each pollutant for each case in the database). ^ Logistic regressions were conducted to estimate odds ratios of the two outcomes. Three analyses were conducted: one for all records, another for visits during the four months of April and September of 2005 and 2009, and a third one for visits from zip codes that are close to PM2.5 monitoring stations (east area of Harris County). The last two analyses were designed to investigate special temporal and spatial characteristics of the associations. ^ The dataset included all ER visits surveyed by Safety Net from 2004 to 2009, exceeding 3 million visits for all causes. There were 95,765 COPD and 96,596 CVD cases during this six year period. A 1-μg/m3 increase in PM2.5 on the same day was associated with a 1.0% increase in the odds of chronic obstructive pulmonary disease emergency room diagnoses, a 0.4% increase in the odds of cardiovascular disease emergency room diagnoses, and a 0.2% increase in the odds of cardiovascular disease emergency room diagnoses on the following day. A 1-ppb increase in ozone was associated with a 0.1% increase in the odds of chronic obstructive pulmonary disease emergency room diagnoses on the same day. These four percentages add up to 1.7% of ER visits. That is, over the period of six years, one unit increase for both ozone and PM2.5 (joint increase), resulted in about 55,286 (3,252,102 * 0.017) extra ER visits for CVD or COPD, or 9,214 extra ER visits per year. ^ After adjustment for age, race, gender, day of the week, temperature, relative humidity, east wind component, north wind component, and wind speed, there were statistically significant associations between emergency room chronic obstructive pulmonary disease diagnosis in Harris County, Texas, with joint exposure to ozone and fine particulate matter for the same day; and between emergency room cardiovascular disease diagnosis and exposure to PM2.5 of the same day and the previous day. ^ Despite the small association between the two air pollutants and the health outcomes, this study points to important findings. Namely, the need to identify reasons for the increase of CVD and COPD ER visits over the course of the project, the statistical association between humidity (or whatever other variables for which it may serve as a surrogate) and CVD and COPD cases, and the confirmatory finding that males and blacks have higher odds for the two outcomes, as consistent with other studies. ^ An important finding of this research suggests that the number and distribution of PM2.5 monitors in Harris County - although not evenly spaced geographically—are adequate to detect significant association between exposure and the two outcomes. In addition, this study points to other potential factors that contribute to the rising incidence rates of CVD and COPD ER visits in Harris County such as population increases, patient history, life style, and other pollutants. Finally, results of validation, using a subset of the data demonstrate the robustness of the models.^
Resumo:
Vertical distribution of organic phosphorus and phosphatase activity was studied in the Southeast Pacific Ocean. The average rate of mineralization of organic phosphorus in the 0-200 m layer was shown to differ by a factor of 5-10 in oligotrophic and eutrophic areas, while residence time of phosphorus in production-destruction cycles differed by a factor of only 2-5, apparently because of both concentration of organic phosphorus and phosphorolysis rate increased simultaneously in the areas.