886 resultados para Parliamentary technology assessment


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Topic

To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.

Clinical Relevance

Traditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests.

Methods

Systematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias.

Results

We included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%–93%) and 48% (95% CI, 30%–67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias.

Conclusions

There is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.

OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.

DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).

REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.

INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).

COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.

RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.

LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.

CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.

FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background

Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.

Objectives

To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.

Search methods

We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.

Selection Criteria

We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.

Data collection and analysis

Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.

Main results

We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.

Authors' conclusions

Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Nursing homes for older people provide an environment likely to promote the acquisition and spread of meticillin-resistant Staphylococcus aureus (MRSA), putting residents at increased risk of colonisation and infection. It is recognised that infection prevention and control strategies are important in preventing and controlling MRSA transmission.

Objectives: To determine the effects of infection prevention and control strategies for preventing the transmission of MRSA in nursing homes for older people.

Search methods: In August 2013, for this third update, we searched the Cochrane Wounds Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), Database of Abstracts of Reviews of Effects (DARE, The Cochrane Library), Ovid MEDLINE, OVID MEDLINE (In-process and Other Non-Indexed Citations), Ovid EMBASE, EBSCO CINAHL, Web of Science and the Health Technology Assessment (HTA) website. Research in progress was sought through Current Clinical Trials, Gateway to Reseach, and HSRProj (Health Services Research Projects in Progress).

Selection criteria: All randomised and controlled clinical trials, controlled before and after studies and interrupted time series studies of infection prevention and control interventions in nursing homes for older people were eligible for inclusion.

Data collection and analysis: Two review authors independently reviewed the results of the searches. Another review author appraised identified papers and undertook data extraction which was checked by a second review author.

Main results: For this third update only one study was identified, therefore it was not possible to undertake a meta-analysis. A cluster randomised controlled trial in 32 nursing homes evaluated the effect of an infection control education and training programme on MRSA prevalence. The primary outcome was MRSA prevalence in residents and staff, and a change in infection control audit scores which measured adherence to infection control standards. At the end of the 12 month study, there was no change in MRSA prevalence between intervention and control sites, while mean infection control audit scores were significantly higher in the intervention homes compared with control homes.

Authors' conclusions: There is a lack of research evaluating the effects on MRSA transmission of infection prevention and control strategies in nursing homes. Rigorous studies should be conducted in nursing homes, involving residents and staff to test interventions that have been specifically designed for this unique environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Diabetic retinopathy is an important cause of visual loss. Laser photocoagulation preserves vision in diabetic retinopathy but is currently used at the stage of proliferative diabetic retinopathy (PDR).

OBJECTIVES: The primary aim was to assess the clinical effectiveness and cost-effectiveness of pan-retinal photocoagulation (PRP) given at the non-proliferative stage of diabetic retinopathy (NPDR) compared with waiting until the high-risk PDR (HR-PDR) stage was reached. There have been recent advances in laser photocoagulation techniques, and in the use of laser treatments combined with anti-vascular endothelial growth factor (VEGF) drugs or injected steroids. Our secondary questions were: (1) If PRP were to be used in NPDR, which form of laser treatment should be used? and (2) Is adjuvant therapy with intravitreal drugs clinically effective and cost-effective in PRP?

ELIGIBILITY CRITERIA: Randomised controlled trials (RCTs) for efficacy but other designs also used.


REVIEW METHODS: Systematic review and economic modelling.

RESULTS: The Early Treatment Diabetic Retinopathy Study (ETDRS), published in 1991, was the only trial designed to determine the best time to initiate PRP. It randomised one eye of 3711 patients with mild-to-severe NPDR or early PDR to early photocoagulation, and the other to deferral of PRP until HR-PDR developed. The risk of severe visual loss after 5 years for eyes assigned to PRP for NPDR or early PDR compared with deferral of PRP was reduced by 23% (relative risk 0.77, 99% confidence interval 0.56 to 1.06). However, the ETDRS did not provide results separately for NPDR and early PDR. In economic modelling, the base case found that early PRP could be more effective and less costly than deferred PRP. Sensitivity analyses gave similar results, with early PRP continuing to dominate or having low incremental cost-effectiveness ratio. However, there are substantial uncertainties. For our secondary aims we found 12 trials of lasers in DR, with 982 patients in total, ranging from 40 to 150. Most were in PDR but five included some patients with severe NPDR. Three compared multi-spot pattern lasers against argon laser. RCTs comparing laser applied in a lighter manner (less-intensive burns) with conventional methods (more intense burns) reported little difference in efficacy but fewer adverse effects. One RCT suggested that selective laser treatment targeting only ischaemic areas was effective. Observational studies showed that the most important adverse effect of PRP was macular oedema (MO), which can cause visual impairment, usually temporary. Ten trials of laser and anti-VEGF or steroid drug combinations were consistent in reporting a reduction in risk of PRP-induced MO.

LIMITATION: The current evidence is insufficient to recommend PRP for severe NPDR.

CONCLUSIONS: There is, as yet, no convincing evidence that modern laser systems are more effective than the argon laser used in ETDRS, but they appear to have fewer adverse effects. We recommend a trial of PRP for severe NPDR and early PDR compared with deferring PRP till the HR-PDR stage. The trial would use modern laser technologies, and investigate the value adjuvant prophylactic anti-VEGF or steroid drugs.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42013005408.

FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Care of critically ill patients in intensive care units (ICUs) often requires potentially invasive or uncomfortable procedures, such as mechanical ventilation (MV). Sedation can alleviate pain and discomfort, provide protection from stressful or harmful events, prevent anxiety and promote sleep. Various sedative agents are available for use in ICUs. In the UK, the most commonly used sedatives are propofol (Diprivan(®), AstraZeneca), benzodiazepines [e.g. midazolam (Hypnovel(®), Roche) and lorazepam (Ativan(®), Pfizer)] and alpha-2 adrenergic receptor agonists [e.g. dexmedetomidine (Dexdor(®), Orion Corporation) and clonidine (Catapres(®), Boehringer Ingelheim)]. Sedative agents vary in onset/duration of effects and in their side effects. The pattern of sedation of alpha-2 agonists is quite different from that of other sedatives in that patients can be aroused readily and their cognitive performance on psychometric tests is usually preserved. Moreover, respiratory depression is less frequent after alpha-2 agonists than after other sedative agents.

OBJECTIVES: To conduct a systematic review to evaluate the comparative effects of alpha-2 agonists (dexmedetomidine and clonidine) and propofol or benzodiazepines (midazolam and lorazepam) in mechanically ventilated adults admitted to ICUs.

DATA SOURCES: We searched major electronic databases (e.g. MEDLINE without revisions, MEDLINE In-Process & Other Non-Indexed Citations, EMBASE and Cochrane Central Register of Controlled Trials) from 1999 to 2014.

METHODS: Evidence was considered from randomised controlled trials (RCTs) comparing dexmedetomidine with clonidine or dexmedetomidine or clonidine with propofol or benzodiazepines such as midazolam, lorazepam and diazepam (Diazemuls(®), Actavis UK Limited). Primary outcomes included mortality, duration of MV, length of ICU stay and adverse events. One reviewer extracted data and assessed the risk of bias of included trials. A second reviewer cross-checked all the data extracted. Random-effects meta-analyses were used for data synthesis.

RESULTS: Eighteen RCTs (2489 adult patients) were included. One trial at unclear risk of bias compared dexmedetomidine with clonidine and found that target sedation was achieved in a higher number of patients treated with dexmedetomidine with lesser need for additional sedation. The remaining 17 trials compared dexmedetomidine with propofol or benzodiazepines (midazolam or lorazepam). Trials varied considerably with regard to clinical population, type of comparators, dose of sedative agents, outcome measures and length of follow-up. Overall, risk of bias was generally high or unclear. In particular, few trials blinded outcome assessors. Compared with propofol or benzodiazepines (midazolam or lorazepam), dexmedetomidine had no significant effects on mortality [risk ratio (RR) 1.03, 95% confidence interval (CI) 0.85 to 1.24, I (2) = 0%; p = 0.78]. Length of ICU stay (mean difference -1.26 days, 95% CI -1.96 to -0.55 days, I (2) = 31%; p = 0.0004) and time to extubation (mean difference -1.85 days, 95% CI -2.61 to -1.09 days, I (2) = 0%; p < 0.00001) were significantly shorter among patients who received dexmedetomidine. No difference in time to target sedation range was observed between sedative interventions (I (2) = 0%; p = 0.14). Dexmedetomidine was associated with a higher risk of bradycardia (RR 1.88, 95% CI 1.28 to 2.77, I (2) = 46%; p = 0.001).

LIMITATIONS: Trials varied considerably with regard to participants, type of comparators, dose of sedative agents, outcome measures and length of follow-up. Overall, risk of bias was generally high or unclear. In particular, few trials blinded assessors.

CONCLUSIONS: Evidence on the use of clonidine in ICUs is very limited. Dexmedetomidine may be effective in reducing ICU length of stay and time to extubation in critically ill ICU patients. Risk of bradycardia but not of overall mortality is higher among patients treated with dexmedetomidine. Well-designed RCTs are needed to assess the use of clonidine in ICUs and identify subgroups of patients that are more likely to benefit from the use of dexmedetomidine.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42014014101.

FUNDING: The National Institute for Health Research Health Technology Assessment programme. The Health Services Research Unit is core funded by the Chief Scientist Office of the Scottish Government Health and Social Care Directorates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: The needs of children with autism spectrum disorder (ASD) are complex and this is reflected in the number and diversity of outcomes assessed and measurement tools used to collect evidence about children's progress. Relevant outcomes include improvement in core ASD impairments, such as communication, social awareness, sensory sensitivities and repetitiveness; skills such as social functioning and play; participation outcomes such as social inclusion; and parent and family impact.

OBJECTIVES: To examine the measurement properties of tools used to measure progress and outcomes in children with ASD up to the age of 6 years. To identify outcome areas regarded as important by people with ASD and parents.

METHODS: The MeASURe (Measurement in Autism Spectrum disorder Under Review) research collaboration included ASD experts and review methodologists. We undertook systematic review of tools used in ASD early intervention and observational studies from 1992 to 2013; systematic review, using the COSMIN checklist (Consensus-based Standards for the selection of health Measurement Instruments) of papers addressing the measurement properties of identified tools in children with ASD; and synthesis of evidence and gaps. The review design and process was informed throughout by consultation with stakeholders including parents, young people with ASD, clinicians and researchers.

RESULTS: The conceptual framework developed for the review was drawn from the International Classification of Functioning, Disability and Health, including the domains 'Impairments', 'Activity Level Indicators', 'Participation', and 'Family Measures'. In review 1, 10,154 papers were sifted - 3091 by full text - and data extracted from 184; in total, 131 tools were identified, excluding observational coding, study-specific measures and those not in English. In review 2, 2665 papers were sifted and data concerning measurement properties of 57 (43%) tools were extracted from 128 papers. Evidence for the measurement properties of the reviewed tools was combined with information about their accessibility and presentation. Twelve tools were identified as having the strongest supporting evidence, the majority measuring autism characteristics and problem behaviour. The patchy evidence and limited scope of outcomes measured mean these tools do not constitute a 'recommended battery' for use. In particular, there is little evidence that the identified tools would be good at detecting change in intervention studies. The obvious gaps in available outcome measurement include well-being and participation outcomes for children, and family quality-of-life outcomes, domains particularly valued by our informants (young people with ASD and parents).

CONCLUSIONS: This is the first systematic review of the quality and appropriateness of tools designed to monitor progress and outcomes of young children with ASD. Although it was not possible to recommend fully robust tools at this stage, the review consolidates what is known about the field and will act as a benchmark for future developments. With input from parents and other stakeholders, recommendations are made about priority targets for research.

FUTURE WORK: Priorities include development of a tool to measure child quality of life in ASD, and validation of a potential primary outcome tool for trials of early social communication intervention.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42012002223.

FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

DESIGN We will address our research objectives by searching the published and unpublished literature and conducting an evidence synthesis of i) studies of the effectiveness of psychosocial interventions provided for children and adolescents who have suffered maltreatment, ii) economic evaluations of these interventions and iii) studies of their acceptability to children, adolescents and their carers. SEARCH STRATEGY: Evidence will be identified via electronic databases for health and allied health literature, social sciences and social welfare, education and other evidence based depositories, and economic databases. We will identify material generated by user-led,voluntary sector enquiry by searching the internet and browsing the websites of relevant UK government departments and charities. Additionally, studies will be identified via the bibliographies of retrieved articles/reviews; targeted author searches; forward citation searching. We will also use our extensive professional networks, and our planned consultations with key stakeholders and our study steering committee. Databases will be searched from inception to time of search. REVIEW STRATEGY Inclusion criteria: 1) Infants, children or adolescents who have experienced maltreatment between the ages of 0 17 years. 2) All psychosocial interventions available for maltreated children and adolescents, by any provider and in any setting, aiming to address the sequelae of any form of maltreatment, including fabricated illness. 3) For synthesis of evidence of effectiveness: all controlled studies in which psychosocial interventions are compared with no-treatment, treatment as usual, waitlist or other-treated controls. For a synthesis of evidence of acceptability we will include any design that asks participants for their views or provides data on non-participation. For decision-analytic modelling we may include uncontrolled studies. Primary and secondary outcomes will be confirmed in consultation with stakeholders. Provisional primary outcomes are psychological distress/mental health (particularly PTSD, depression and anxiety, self-harm); ii) behaviour; iii) social functioning; iv) cognitive / academic attainment, v) quality of life, and vi) costs. After studies that meet the inclusion criteria have been identified (independently by two reviewers), data will be extracted and risk of bias (RoB) assessed (independently by two reviewers) using the Cochrane Collaboration RoB Tool (effectiveness), quality hierarchies of data sources for economic analyses (cost-effectiveness) and the CASP tool for qualitative research (acceptability). Where interventions are similar and appropriate data are available (or can be obtained) evidence synthesis will be performed to pool the results. Where possible, we will explore the extent to which age, maltreatment history (including whether intra- or extra-familial), time since maltreatment, care setting (family / out-of-home care including foster care/residential), care history, and characteristics of intervention (type, setting, provider, duration) moderate the effects of psychosocial interventions. A synthesis of acceptability data will be undertaken, using a narrative approach to synthesis. A decision-analytic model will be constructed to compare the expected cost-effectiveness of the different types of intervention identified in the systematic review. We will also conduct a Value of information analysis if the data permit. EXPECTED OUTPUTS: A synthesis of the effectiveness and cost effectiveness of psychosocial interventions for maltreated children (taking into account age, maltreatment profile and setting) and their acceptability to key stakeholders.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For the actual existence of e-government it is necessary and crucial to provide public information and documentation, making its access simple to citizens. A portion, not necessarily small, of these documents is in an unstructured form and in natural language, and consequently outside of which the current search systems are generally able to cope and effectively handle. Thus, in thesis, it is possible to improve access to these contents using systems that process natural language and create structured information, particularly if supported in semantics. In order to put this thesis to test, this work was developed in three major phases: (1) design of a conceptual model integrating the creation of structured information and making it available to various actors, in line with the vision of e-government 2.0; (2) definition and development of a prototype instantiating the key modules of this conceptual model, including ontology based information extraction supported by examples of relevant information, knowledge management and access based on natural language; (3) assessment of the usability and acceptability of querying information as made possible by the prototype - and in consequence of the conceptual model - by users in a realistic scenario, that included comparison with existing forms of access. In addition to this evaluation, at another level more related to technology assessment and not to the model, evaluations were made on the performance of the subsystem responsible for information extraction. The evaluation results show that the proposed model was perceived as more effective and useful than the alternatives. Associated with the performance of the prototype to extract information from documents, comparable to the state of the art, results demonstrate the feasibility and advantages, with current technology, of using natural language processing and integration of semantic information to improve access to unstructured contents in natural language. The conceptual model and the prototype demonstrator intend to contribute to the future existence of more sophisticated search systems that are also more suitable for e-government. To have transparency in governance, active citizenship, greater agility in the interaction with the public administration, among others, it is necessary that citizens and businesses have quick and easy access to official information, even if it was originally created in natural language.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUMO - Os gastos com a saúde, em Portugal, como nos países da União Europeia e da OCDE, têm crescido a um ritmo superior ao do crescimento económico, assumindo uma importância crescente face ao PIB. Entre estes factores surge a velocidade da introdução da inovação e dos desenvolvimentos tecnológicos dos domínios do diagnóstico e da terapêutica. Uma das mais difíceis e importantes questões para as políticas de saúde é a relação entre a saúde e os gastos com a prestação de cuidados de saúde. Estudos recentes sugerem que os cuidados de saúde ocupam um papel importante na melhoria da saúde da população, e que os recentes avanços tecnológicos são custo-efectivos aceites na generalidade por cada ano de vida ganho. Este trabalho visa estudar a influência que o financiamento e o estatuto jurídico hospitalar têm na introdução e adopção de novas tecnologias em saúde. Para isso, além da revisão bibliográfica, foi realizada uma análise a uma base de dados, cujos elementos se cingem a pacientes com doenças cardiovasculares atendidos num dos hospitais do Serviço Nacional de Saúde, entre 2000 e 2006. --- ------------------------------------ABSTRACT - Health expenditures in Portugal, as in EU countries and in the OECD, have developed at a higher rate than economic growth, assuming an increasing importance to the GDP. Among these factors appears the speed of the introduction of innovation and technological development in diagnosis and therapy areas. One of the most difficult and most important questions for health policy is the relationship of health to health care spending. Studies now suggest that medical care has played an important role in improving the health of the population, and recent technical advances are cost-effective at generally accepted values of an added year of life. This work aims to study the influence that the prospective payment and the hospital’s legal status have in introduction and adoption of new technologies in health. For this, besides the literature review, an analysis was made to a database, whose elements are confined to patients with cardiovascular disease treated in the hospitals of t

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Contemporary thoracic and cardiovascular surgery uses extensive equipment and devices to enable its performance. As the specialties develop and new frontiers are crossed, the technology needs to advance in a parallel fashion. Strokes of genius or problem-solving brain-storming may generate great ideas, but the metamorphosis of an idea into a physical functioning tool requires a lot more than just a thinking process. A modern surgical device is the end-point of a sophisticated, complicated and potentially treacherous route, which incorporates new skills and knowledge acquisition. Processes including technology transfer, commercialisation, corporate and product development, intellectual property and regulatory routes all play pivotal roles in this voyage. Many good ideas may fall by the wayside for a multitude of reasons as they may not be marketable or may be badly marketed. In this article, we attempt to illuminate the components required in the process of surgical innovation, which we believe must remain in the remit of the modern-day thoracic and cardiovascular surgeon.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Deux thématiques importantes des technologies de la santé: la pratique médicale fondée sur des preuves probantes et l’évaluation des interventions en médecine sont fondées sur une approche positiviste et une conception mécaniste des organisations en santé. Dans ce mémoire, nous soulevons l’hypothèse selon laquelle les théories de la complexité et la systémique permettent une conceptualisation différente de ces deux aspects de la gouvernance clinique d’une unité de Soins Intensifs Chirurgicaux (SIC), qui est considérée comme un système adaptatif dynamique non linéaire qui nécessite une approche systémique de la cognition. L’étude de cas d’une unité de SIC, permet de démontrer par de nombreux exemples et des analyses de micro-situations, toutes les caractéristiques de la complexité des patients critiques et instables et de la structure organisationnelle des SIC. Après une critique épistémologique de l’Evidence-Based Medicine nous proposons une pratique fondée sur des raisonnements cliniques alliant l’abduction, l’herméneutique et la systémique aux SIC. En nous inspirant des travaux de Karl Weick, nous suggérons aussi de repenser l’évaluation des modes d’interventions cliniques en s’inspirant de la notion d’organisation de haute fiabilité pour mettre en place les conditions nécessaires à l’amélioration des pratiques aux SIC.