156 resultados para Parafusos protéticos


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Reabilitação Oral - FOAR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although one cannot prevent the birth of human beings with cleft palate lesions one can adopt attitudes and various procedures entirely viable to rehabilitate and recuperate these persons through a team work composed of the facilities of a hospital, physician, dentist, psychotherapist, epeech pathologist, pedagogue and a social worker. In order to reduce the suffering of these patients we took up this work to prove that even if not in an ideal manner nevertheleses in an acceptable one we can reintegrate these persons to their families, friends and social milieu, offering them more security in their social, psychic and human relationships. We have made a review of the literature during the last three decades where we found many possibilities of prosthetic recuperations which concerns esthetics, mastication and maxillomandibular relationships beyond allowing these pacients conditions to perform satisfactory the functions of deglution and speech. We have selected and executed 5 clinical cases out of 15 pacients formely choosen looking to different prosthetic plannings. We have also shown the major contribution that the osseous integrated implants can offer to the rehabilitation and recuperation of pacients whith congenitall labio palatal lesions. To simplify the understanding we tried to discuss the most varied types of prosthesis in well defined subjects having a separate approach for each of them and we still showed that the specificity of each case leads to a specific type of rehabilitation founded om esthetics, occlusion, osseous suport, edentulous space, and above all based in the common sense and Professional integrity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The connections in the wood structures are the places with high concentrations of stresses and therefore are more fragile than the rest of the structure. The connections between pieces of wood can be made by metal pins (nails or screws). The compression and embedment strength has significant influence on the calculation of the connections. The main aim of this work was to evaluate the compression and embedment strength in the directions parallel, inclined at 45° and normal to the grain, using standard specimens according to ABNT NBR 7190/1997 standard. The compression and embedment strength were initially evaluated according to ABNT NBR 7190/1997, which admits the deformation of 2‰ as limit of embedment and the ratio between the ultimate strength and the area of application of load in the specimen for the compressive strength. Afterward, the embedment strength was evaluated by the EUROCEDE 5 /1995 European standard, which use the limit of 5 mm of the displacement for the embedment. Specimens of Pinus oocarpa, Cumaru and Pinus taeda were used in tests to calibration of equipment and specimens of Pinus taeda and Eucalipto citriodora were used to compare the results of strength. The results of strength were evaluated based on statistical analysis. The results of compressive strength for the Pinus taeda showed no significant differences in embedment strength in the directions parallel and normal to the grain. For the Eucalipto citriodora only in the direction parallel to grain the compression strength was not significant compared with the embedment strength. For both species, only the parallel compression strength and inclined at 45o to the grain, which were to the grain, which were admitted the strain of 2‰ were not significantly different compared with the compression strength determined according to ABNT NBR 7190/1997. The normal compression strength obtained according to ABNT NBR 7190/1997 and ultimate compression strength not ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biological principles of osseointegration caused the rehabilitation treatment with osseointegrated implant become a safe, well alternative accepted by the dental community for the high success rate, allowing the preparation of functional and aesthetic prostheses in edentulous and partial patients. We passed the initial phase of functional vision for an aesthetic approach, too, depending on the demands of the patient and the quest for excellence by professionals. Over these last years, implant treatment has undergone many changes in surgical and prosthetic protocols. The less invasive surgical techniques and the development of restorative materials, especially ceramics allow the prosthetic rehabilitation of high functional quality and aesthetics. The installation of implants in sockets immediately after extraction of teeth involved by fracture, periodontal disease, endodontic lesions, is part of the arsenal of techniques for rehabilitating a number of advantages that we get to the outcome of multidisciplinary treatment. For this, we must consider several criteria in its planning as a fundamental unit, adjacent teeth, multiple losses, system, form and number of implants, type of retention of the prosthesis components, the patient expectation of the outcome perspective, gingival biotype, standard of ridge resorption, the smile line, etc. occlusal analysis. With the three-dimensional placement of the implant can immediately join the biological processes of repair of the socket, implant osseointegration, speeding treatment time. Much has been made by companies in the surface treatment of endosseous implants to be osseointegration shortened and restorative procedures started earlier, bringing benefits to the patient and professional. Among the main advantages we can emphasize the preservation of the structures adjacent to the teeth replaced, minor resorption of bone tissue involved... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The automobile industry is increasingly interested in reducing vehicle weight for greater speed, lower fuel consumption and emissions, through innovation of materials and processes. One way to do this is to seek the replacement of conventional processes by the use of structural adhesives. Structural adhesives are highly resistant materials, which can replace rivets, bolts and welds allowing the substrate / adhesive assemble is stronger than the substrate itself. One of the major advantages of gluing with respect to welding is its esthetic appearance, since it does not leave marks. For this reason, parts to be soldered require a minimum thickness so that the marks do not appear, since the pieces from gluing have no restriction as to the thickness. By replacing the vibration welding process for gluing process of the instrument panel parts of an automobile, one obtains a reduction of the thickness of the parts and therefore it decreases the weight of the car. This work aims to study the various structural adhesives that already exist on the market to be applied on the instrument panel. The mechanical test performed to measure the maximum adhesive strength was the Lap Shear Test at 23°C (room temperature), -35°C and 85°C. The types of adhesives used were the hot-melt and the bi-component. By the results obtained, it is in favor using the bi-component for application to the union of instrument panel parts

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium and its alloys has been widely used as materials for metallic biomaterials implants are usually employed to restore the hard tissue function, being used for artificial joints and bones, synthetic plates, crowns, dental implants and screws . Objective of this work was the surface modification of Ti-alloy 25Ta from biomimetic surface treatment of employment and deposition of polymer by electrospinning. The league was obtained from the fusion of the pure elements in the arc furnace with controlled atmosphere. The ingots were subjected to heat treatment, cold forged and sectioned discs with 13 mm diameter and 3 mm thick. Two surface treatments was evaluated, biomimetic and electrospinning with PCL fiber. The biomimetic treatment was performed involving alkaline treatment for three molarities 1.5M, 3M and 5M with immersion in SBF. The electrospinning was performed using PCL polymer alloy surface after the alkali treatment Ti25Ta 1M. For this group the polymer coated surfaces were immersed in calcium phosphate containing solution for immobilization of apatite. The results were compared with previous studies using surface treatment group to verify hydroxyapatite formation on the sample surface and it is concluded that the best condition is biomimetic treatment with 5M alkali treatment and heat treatment at 80 ° C for 72 hours

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, the correction of skeletal vertical dysplasia is considered a great challenge in Orthodontics. The skeletal open bite treatment presents limitations related to vertical growth pattern, the extension of open bite and especially the stability, which is very questioned. The treatment of skeletal open bite is mostly realized by the inhibition of vertical alveolar posterior development (relative intrusion) or absolute intrusion of posterior teeth, through vertical forces, generated by the action of masticatory muscles. The purpose of this article is to present a new appliance for the treatment of skeletal open bite, the VABB (Vertically Activated Bite Block) or modified Bite Block, whose action mechanism is to limit the vertical development of the molars, by the action of facial muscles and two bilateral expansion screws that provide a counterclockwise rotation of the mandible. It will also be presented a clinical case and the technical steps for the construction of this appliance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Trying to provide more anatomical data to the oral and maxillofacial surgeons regarding to orthognathic surgery, specifically about sagittal split osteotomy, the authors accomplished an anatomical study in dry human jaws, measuring the thickness in four previously established points of the body and mandibular ramus, at the usual spots used for the internal fixation by screws. Material and Methods: The authors also use the data collected to evaluate if there are significant differences between the group I (human dry mandibles with teeth) and group II (edentulous human dry mandibles). Results: For the group I the authors found the following results: x1 = 14,48, x2 = 14,94, x3=12,82 and x4 = 9,41, being the x2 the thickest point, and the least thick the x4. However in the group II, the found medium values were: x1 = 13,38, x2 = 13,08, x3 = 11,63 and x4 = 12,18, being the thickest point in that group the x1 and the least thick x3. The coefficient of simple correlation between the variables (group I and II) revealed a value of 0,6194, being this difference no significant at the meaning level of 95%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aproximadamente 20 a 22 % das fraturas em felinos são pélvicas e quase metade destas são em ilío, que muitas vezes estão associadas a outras lesões pélvicas ósseas e a tecidos moles. A indicação cirúrgica para o tratamento destas lesões depende do grau de instabilidade, de perda da continuidade óssea, colapso do canal pélvico, fraturas acetabulares, envolvimento de estruturas do eixo de sustentação de peso do animal, lesão nervosa e dor intratável mesmo com uso de analgésicos. O objetivo desta revisão sistemática foi comparar o uso de quatro métodos diferentes para a osteossíntese de ílio em gatos, sendo estes: as placas laterais, placas dorsais, placas em T e, parafusos, fios de Kirschner, fios de aço e polimetilmetacrilato usados em conjunto, em relação às implicações e complicações do uso de cada uma das técnicas. Foram utilizados artigos científicos retrospectivos e prospectivos publicados nas bases de dados informatizados PUBMED, Scielo, Periódico Capes e Google Schoolar que abordassem diferentes técnicas para a osteossíntese de ílio em gatos e foi realizada a análise e comparação de seus dados. Quatro artigos foram selecionados por serem adequados para abordar o tema indicado, todos redigidos em língua inglesa, porém, um sendo de origem francesa e três de origem britânica, cada artigo relatando um tipo diferente de método utilizado. A discussão e a conclusão se deram com base nestes artigos. Nenhuma das técnicas pode ser considerada perfeitamente adequada para qualquer osteossíntese de ílio. Cada uma das quatro possui prós e contras e tem demonstrado melhor eficácia para um tipo específico de fratura ilíaca em gatos, cabendo ao cirurgião veterinário reconhecer e selecionar a melhor a ser utilizada em cada situação