856 resultados para Panel painting, Gothic
Resumo:
Introduction Many therapeutic decisions in the management of fistulizing and fibrostenotic Crohn's disease (CD) have to be taken without the benefit of strong scientific evidence. For this reason, explicit appropriateness criteria for CD fistula and stenosis treatment were developed by a multidisciplinary European expert panel in 2004 with the aim of making them easily available on the Internet and thus allowing individual case scenario evaluation; these criteria were updated in 2007. Methods Twelve international experts convened in Geneva, Switzerland in December 2007. Explicit clinical scenarios, corresponding to real daily practice, were rated on a 9-point scale based on evidence from the published literature and panelists' own expertise. Median ratings were stratified into three categories: appropriate (7-9), uncertain (4-6) and inappropriate (1-3). Results Overall, panelists rated 60 indications pertaining to fistulas. Antibiotics, azathioprine/6-mercaptopurine and conservative surgery are the mainstay of therapy for simple and complex fistulas. In the event of previous failure of azathioprine/6-mercaptopurine therapy, methotrexate and infliximab were considered appropriate for complex fistulas. The panel also rated 72 indications related to the management of fibrostenotic CD. The experts considered balloon dilation, if the stricture was endoscopically accessible, stricturoplasty and bowel resection to be appropriate for small bowel fibrostenotic Crohn's disease, and balloon dilation and bowel resection appropriate for fibrostenotic colonic disease. In the presence of an ileocolonic or ileorectal anastomotic stricture of <7 cm, endoscopic balloon dilation, and bowel resection were considered appropriate. Conclusion Antibiotics, azathioprine/6-mercaptopurine, and conservative surgery are the mainstay of therapy for fistulizing Crohn's disease. Infliximab is a therapeutic option in patients without prior response to immunosuppressant therapy. In fibrostenotic Crohn's disease, endoscopic balloon dilation, if feasible, or surgical therapy should be considered. These expert recommendations are available online (www.epact.ch). Prospective evaluation is now needed to test the validity of these appropriateness criteria in clinical practice.
Resumo:
We analyze whether the interviewers' political opinions have an influence on those of the respondents. The research uses data from a panel survey in which interviewers are randomly assigned to respondents. The results show that the respondents express significantly similar opinions to those of the interviewers in all questions considered. Multilevel models show that more educated respondents are affected to a slightly higher extent and that the interviewer's experience is also a factor. There is no difference between different respondent subgroups or when both interviewers and respondents share the same socio-demographic characteristics. While there is no evidence for respondents wanting to please the interviewers, the hypothesis of socially desirable behavior can indeed be confirmed.
Resumo:
The classification of Art painting images is a computer vision applications that isgrowing considerably. The goal of this technology, is to classify an art paintingimage automatically, in terms of artistic style, technique used, or its author. For thispurpose, the image is analyzed extracting some visual features. Many articlesrelated with these problems have been issued, but in general the proposed solutionsare focused in a very specific field. In particular, algorithms are tested using imagesat different resolutions, acquired under different illumination conditions. Thatmakes complicate the performance comparison of the different methods. In thiscontext, it will be very interesting to construct a public art image database, in orderto compare all the existing algorithms under the same conditions. This paperpresents a large art image database, with their corresponding labels according to thefollowing characteristics: title, author, style and technique. Furthermore, a tool thatmanages this database have been developed, and it can be used to extract differentvisual features for any selected image. This data can be exported to a file in CSVformat, allowing researchers to analyze the data with other tools. During the datacollection, the tool stores the elapsed time in the calculation. Thus, this tool alsoallows to compare the efficiency, in computation time, of different mathematicalprocedures for extracting image data.
Resumo:
MicroRNAs (miRNA) are recognized posttranscriptional gene repressors involved in the control of almost every biological process. Allelic variants in these regions may be an important source of phenotypic diversity and contribute to disease susceptibility. We analyzed the genomic organization of 325 human miRNAs (release 7.1, miRBase) to construct a panel of 768 single-nucleotide polymorphisms (SNPs) covering approximately 1 Mb of genomic DNA, including 131 isolated miRNAs (40%) and 194 miRNAs arranged in 48 miRNA clusters, as well as their 5-kb flanking regions. Of these miRNAs, 37% were inside known protein-coding genes, which were significantly associated with biological functions regarding neurological, psychological or nutritional disorders. SNP coverage analysis revealed a lower SNP density in miRNAs compared with the average of the genome, with only 24 SNPs located in the 325 miRNAs studied. Further genotyping of 340 unrelated Spanish individuals showed that more than half of the SNPs in miRNAs were either rare or monomorphic, in agreement with the reported selective constraint on human miRNAs. A comparison of the minor allele frequencies between Spanish and HapMap population samples confirmed the applicability of this SNP panel to the study of complex disorders among the Spanish population, and revealed two miRNA regions, hsa-mir-26a-2 in the CTDSP2 gene and hsa-mir-128-1 in the R3HDM1 gene, showing geographical allelic frequency variation among the four HapMap populations, probably because of differences in natural selection. The designed miRNA SNP panel could help to identify still hidden links between miRNAs and human disease.
Resumo:
Microsatellite instability (MSI) testing in clinics is becoming increasingly widespread; therefore, there is an urgent need for methodology standardization and the availability of quality control. This study is aimed to assess the interlaboratory reproducibility of MSI testing in archive samples by using a panel of 5 recently introduced, mononucleotide repeats (MNR). The quality control involved 8 European institutions. Participants were supplied with DNA extracted from 15 archive colon carcinoma samples and from the corresponding normal tissues. Every group was asked to assess the MSI status of the samples by using the BAT25, BAT26, NR21, NR24, and NR27 mononucleotide markers. Four institutions repeated the analysis using the NCI reference panel to confirm the results obtained with the MNR markers. The overall concordance among institutions for MSI analyses at single locus level was 97.7% when using the MNR panel and 95.0% with the NCI one. The laboratories obtained a full agreement in scoring the MSI status of each patient sample, both using the mononucleotide and the NCI marker sets. With the NCI marker set, however, concordance was lowered to 85.7% when considering the MSI-Low phenotype. Concordance between the 2 panels in scoring the MSI status of each sample was complete if no discrimination was made between MSI-Stable and MSI-L, whereas it dropped to 76.7% if MSI-L was considered. In conclusion, the use of the MNR panel seems to be a robust approach that yields a very high level of reproducibility. The results obtained with the 5 MNR are diagnostically consistent with those obtained by the use of the NCI markers, except for the MSI-Low phenotype.
Resumo:
Introduction: High-grade evidence is lacking for most therapeutic decisions in Crohn's disease. Appropriateness criteria were developed for upper gastro-intestinal, extra-intestinal manifestations and drug safety during conception, pregnancy and breastfeeding in patients with Crohn's disease, to assist the physician in clinical decision making. Methods: The European Panel on the Appropriateness of Crohn's Disease Therapy (EPACT II), a multidisciplinary international European expert panel, rated clinical scenarios based on evidence from the published literature and panelists' own clinical expertise. Median ratings (on a 9-point scale) were stratified into three categories: appropriate (7-9), uncertain (4-6 with or without disagreement) and inappropriate (1-3). Experts were also asked to rank appropriate medications by priority. Results: Proton pump inhibitors, steroids, azathioprine/6-mercaptopurine and infliximab are appropriate for upper gastro-duodenal Crohn's disease; for stenosis, endoscopic balloon dilation is the first-tine therapy, although surgery is also appropriate. Ursodeoxycholic acid is the only appropriate treatment for primary sclerosing cholangitis. Infliximab is appropriate for Pyoderma gangrenosum, ankylosing spondylitis and uveitis, steroids for Pyoderma gangrenosum and ankylosing spondylitis, adalimumab for Pyoderma gangrenosum and ankylosing spondylitis, cyclosporine-A/tacrolimus for Pyoderma gangrenosum. Mesalamine, sulfasalazine, prednisone, azathioprine/6-mercaptopurine, ciprofloxacin, and probiotics, may be administered safety during pregnancy or for patients wishing to conceive, with the exception that mate patients considering conception should avoid sulfasalazine. Metronidazol is considered safe in the 2nd and 3rd trimesters whereas infliximab is rated safe in the 1st trimester but uncertain in the 2nd and 3rd trimesters. Methotrexate is always contraindicated at conception, during pregnancy or during breastfeeding, due to its known teratogenicity. Mesalamine, prednisone, probiotics and infliximab are considered safe during breastfeeding. Conclusion: EPACT II recommendations are freely available online (www.epact.ch). The validity of these criteria should now be tested by prospective evaluation. (C) 2009 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.
Resumo:
This paper proposes a method to conduct inference in panel VAR models with cross unit interdependencies and time variations in the coefficients. The approach can be used to obtain multi-unit forecasts and leading indicators and to conduct policy analysis in a multiunit setups. The framework of analysis is Bayesian and MCMC methods are used to estimate the posterior distribution of the features of interest. The model is reparametrized to resemble an observable index model and specification searches are discussed. As an example, we construct leading indicators for inflation and GDP growth in the Euro area using G-7 information.
Resumo:
The aim of this paper is to analyse the impact of university knowledge and technology transfer activities on academic research output. Specifically, we study whether researchers with collaborative links with the private sector publish less than their peers without such links, once controlling for other sources of heterogeneity. We report findings from a longitudinal dataset on researchers from two engineering departments in the UK between 1985 until 2006. Our results indicate that researchers with industrial links publish significantly more than their peers. Academic productivity, though, is higher for low levels of industry involvement as compared to high levels.
Resumo:
Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.
Resumo:
BACKGROUND: This study examined the reliability of explicit guidelines developed using the RAND-UCLA appropriateness method. METHODS: The appropriateness of over 400 indications for colonoscopy was rated by two multispecialty expert panels (United States and Switzerland). A nine-point scale was used, which was consolidated into three categories of appropriateness: appropriate, uncertain, inappropriate. The distribution of appropriateness ratings between the two panels and the intrapanel and interpanel agreement for categories of appropriateness were calculated for all possible indications. Similar statistics were calculated for a series of 577 primary care patients referred for colonoscopy in Switzerland. RESULTS: Over 80% of all indications (348) could be directly compared. The proportions of indications classified as appropriate, uncertain, or inappropriate were 28.4%, 24.7%, 46.6% and 33.0%, 23.0%, 44.0% for the U.S. and the Swiss panels, respectively. Interpanel agreement was excellent for all the possible indications (kappa value: 0.75) and lower for actual cases (kappa value: 0.51) because of lower agreement for the most frequently encountered indications. CONCLUSIONS: Good agreement between the two sets of criteria was found, pointing to the reliability of the method. Partial disagreement occurred essentially for a few, albeit frequently encountered, indications for use of colonoscopy in cases of uncomplicated lower abdominal pain or constipation.