245 resultados para Pacemaker
Resumo:
Este documento describe el proceso de diseño, configuración e implantación de un sistema clúster VoIP basado íntegramente en software libre.
Resumo:
BACKGROUND The use of remote follow-up (RF) of people with pacemakers (PM) is limited in comparison to the hospital modality (HS), being still poor the scientific evidence that shows their comparative effectiveness. The aim of this study was to compare the quality of life in individuals with different modalities of follow-up. METHODS Controlled, not randomized nor masked clinical trial, with data collection at pre and post-implantation of pacemakers during the 6 months follow-up. All patients over 18 years-old who were implanted a PM during the study period were selected (n = 83), and they were assigned to RF (n = 30) or HF (n = 53) groups according to their personal characteristics and patient's preferences. Baseline characteristics and number of visits to the hospital were analysed, the EuroQol-5D (EQ5D) questionnaire was administered to evaluate the health-related quality of life, and Duke Activity Status Index (DASI) to assess the functional capacity. RESULTS There were no significant differences between both groups in relation to the baseline analysis, EQ5D (RF:0.7299; HF:0.6769) and DASI (RF:21.41; HF:19.99). At 6 months the quality of life was improved in both groups (EQ5D RF:0.8613; HF:0.8175; p = 0,439) still without significant differences between them. DASI score was similar to baseline (20.51 vs 21.80). RF group performed less transmissions/visits per patient (1.57) than hospital group (1.96; relative reduction 31%; p = 0.015). CONCLUSIONS Remote follow-up of people with pacemakers might be considered as an equivalent option to the hospital follow-up in relation to the quality of life and it reduces the number of hospital visits.
Resumo:
Electrical pacing at physiological rate induces myocardial remodeling associated with regional changes in workload, blood flow and oxygen consumption. However, to what extent energy-producing pathways are also modified within the paced heart remains to be investigated. Pacing could particularly affect glycogen metabolism since hypertrophy stimulates glycolysis and increased workload favors glucose over fat oxidation. In order to test this hypothesis, we used the embryonic chick heart model in which ventricular pacing rapidly resulted in thinning of the ventricle wall and thickening of the atrial wall. Hearts of stage 22HH chick embryos were submitted in ovo to asynchronous and intermittent ventricular pacing delivered at physiological rate during 24 h. The resulting alterations of glycogen content were determined in atrium, ventricle and conotruncus of paced and sham-operated hearts. Hemodynamic parameters of the paced and spontaneously beating hearts were derived from computerized image analysis of video recordings. With respect to sham, paced hearts showed a significant decrease in glycogen content (nmoles glucose units/microg protein; mean+/-S.D.) only in atrium (1.48+/-0.40 v 0.84+/-0.34, n=8) and conotruncus (0.75+/-0.28 v 0.42+/-0.23, n=8). Pacing decreased the end diastolic and stroke volumes by 34 and 44%, respectively. Thus, the rapid glycogen depletion in regions remote from the stimulation site appears to be associated with regional changes in workload and remodeling. These findings underscore the importance of the coupling mechanisms between metabolic pathways and myocardial remodeling in the ectopically paced heart.
Resumo:
Circadian and sleep-homeostatic processes both contribute to sleep timing and sleep structure. Elimination of circadian rhythms through lesions of the suprachiasmatic nuclei (SCN), the master circadian pacemaker, leads to fragmentation of wakefulness and sleep but does not eliminate the homeostatic response to sleep loss as indexed by the increase in EEG delta power. In humans, EEG delta power declines during sleep episodes nearly independently of circadian phase. Such observations have contributed to the prevailing notion that circadian and homeostatic processes are separate but recent data imply that this segregation may not extend to the molecular level. Here we summarize the criteria and evidence for a role for clock genes in sleep homeostasis. Studies in mice with targeted disruption for core circadian clock genes have revealed alterations in circadian rhythmicity as well as changes in sleep duration, sleep structure and EEG delta power. Clock-gene expression in brain areas outside the SCN, in particular the cerebral cortex, depends to a large extent on prior sleep-wake history. Evidence for effects of clock genes on sleep homeostasis has also been obtained in Drosophila and humans, pointing to a phylogenetically preserved pathway. These findings suggest that, while within the SCN clock genes are utilized to set internal time-of-day, in the forebrain the same feedback circuitry may be utilized to track time spent awake and asleep. The mechanisms by which clock-gene expression is coupled to the sleep-wake distribution could be through cellular energy charge whereby clock genes act as energy sensors. The data underscore the interrelationships between energy metabolism, circadian rhythmicity, and sleep regulation.
Resumo:
Modern urban lifestyle encourages the prolongation of wakefulness, leaving less and less time for sleep. Although the exact functions of sleep remain one of the biggest mysteries in neuroscience, the society is well aware of the negative consequences of sleep loss on human physical and mental health and performance. Enhancing sleep's recuperative functions might allow shortening sleep duration while preserving the beneficial effects of sleep. During sleep, brain activity oscillates across a continuum of frequencies. Individual oscillations have been suggested to underlie distinct functions for sleep and cognition. Gaining control about individual oscillations might allow boosting their specific functions. Sleep spindles are 11 - 15 Hz oscillations characteristic for light non-rapid-eye-movement sleep (NREMS) and have been proposed to play a role in memory consolidation and sleep protection against environmental stimuli. The reticular thalamic nucleus (nRt) has been identified as the major pacemaker of spindles. Intrinsic oscillatory burst discharge in nRt neurons, arising from the interplay of low-threshold (T-type) Ca2+ channels (T channels) and small conductance type 2 (SK2) K+ channels (SK2 channels), underlies this pacemaking function. In the present work we investigated the impact of altered nRt bursting on spindle generation during sleep by studying mutant mice for SK2 channels and for CaV3.3 channels, a subtype of T channels. Using in vitro electrophysiology I showed that nRt bursting was abolished in CaV3.3 knock out (CaV3.3 KO) mice. In contrast, in SK2 channel over-expressing (SK2-OE) nRt cells, intrinsic repetitive bursting was prolonged. Compared to wildtype (WT) littermates, altered nRt burst discharge lead to weakened thalamic network oscillations in vitro in CaV3.3 KO mice, while oscillatory activity was prolonged in SK2-OE mice. Sleep electroencephalographic recordings in CaV3.3 KO and SK2-OE mice revealed that reduced or potentiated nRt bursting respectively weakened or prolonged sleep spindle activity at the NREMS - REMS transition. Furthermore, SK2-OE mice showed more consolidated NREMS and increased arousal thresholds, two correlates of good sleep quality. This thesis work suggests that CaV3.3 and SK2 channels may be targeted in order to modulate sleep spindle activity. Furthermore, it proposes a novel function for spindles in NREMS consolidation. Finally, it provides evidence that sleep quality may be improved by promoting spindle activity, thereby supporting the hypothesis that sleep quality can be enhanced by modulating oscillatory activity in the brain. Le style de vie moderne favorise la prolongation de l'éveil, laissant de moins en moins de temps pour le sommeil. Même si le rôle exact du sommeil reste un des plus grands mystères des neurosciences, la société est bien consciente des conséquences négatives que provoque un manque de sommeil, à la fois sur le plan de la santé physique et mentale ainsi qu'au niveau des performances cognitives. Augmenter les fonctions récupératrices du sommeil pourrait permettre de raccourcir la durée du sommeil tout en en conservant les effets bénéfiques. Durant le sommeil, on observe des oscillations à travers un continuum de fréquences. Il a été proposé que chaque oscillation pourrait être à l'origine de fonctions spécifiques pour le sommeil et la cognition. Pouvoir de contrôler les oscillations individuelles permettrait d'augmenter leurs fonctions respectives. Les fuseaux sont des oscillations de 11 à 15 Hz caractéristiques du sommeil à ondes lentes léger et il a été suggéré qu'elles jouent un rôle majeur pour la consolidation de la mémoire ainsi que dans la protection du sommeil contre les stimuli environnementaux. Le nucleus réticulaire du thalamus (nRt) a été identifié en tant que générateur de rythme des fuseaux. Les bouffées oscillatoires intrinsèques des neurones du nRt, provenant de l'interaction de canaux calciques à bas seuil de type T (canaux T) et de canaux potassiques à faible conductance de type 2 (canaux SK2), sont à l'origine de la fonction de générateur de rythme. Dans ce travail, j'ai étudié l'impact de la modulation de bouffées de nRT sur la génération des fuseaux pendant le sommeil en investiguant des souris génétiquement modifiées pour les canaux SK2 et les canaux CaV3.3, un sous-type de canaux T. En utilisant l'électrophysiologie in vitro j'ai démontré que les bouffées du nRT étaient abolies dans les souris knock-out du type CaV3.3 (CaV3.3 KO). D'autre part, dans les cellules nRT sur-exprimant les canaux SK2 (SK2-OE), les bouffées oscillatoires intrinsèques étaient prolongées. Par rapport aux souris wild type, les souris CaV3.3 KO ont montré un affaiblissement des oscillations thalamiques en réponse à un changement des bouffées de nRT, alors que l'activité oscillatoire était prolongée dans les souris SK2-OE. Des enregistrements EEG du sommeil dans des souris de type CaV3.3 KO et SK2-OE ont révélé qu'une réduction ou augmentation des bouffées nRT ont respectivement affaibli ou prolongé l'activité des fuseaux durant les transitions du sommeil à ondes lentes au sommeil paradoxal. De plus, les souris SK2-OE ont montré des signes de consolidation du sommeil à ondes lentes et un seuil augmenté pour le réveil, deux mesures qui corrèlent avec une bonne qualité du sommeil. Le travail de cette thèse propose que les canaux CaV3.3 et SK2 pourrait être ciblés pour moduler l'activité des fuseaux. De plus, je propose une fonction nouvelle pour les fuseaux dans la consolidation du sommeil à ondes lentes. Finalement je suggère que la qualité du sommeil peut être améliorée en promouvant l'activité des fuseaux, soutenant ainsi l'idée que la qualité du sommeil peut être améliorée en modulant l'activité oscillatoire dans le cerveau.
Resumo:
AIMS: Experimental models have reported conflicting results regarding the role of dispersion of repolarization in promoting atrial fibrillation (AF). Repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization when propagation velocity is involved. METHODS AND RESULTS: In this work, original electrophysiological parameters were analysed to study AF susceptibility in a chronic sheep model of pacing-induced AF. Two pacemakers were implanted, each with a single right atrial lead. Right atrial depolarization and repolarization waves were documented at 2-week intervals. A significant and gradual decrease in the propagation velocity at all pacing rates and in the right atrial effective refractory period (ERP) was observed during the weeks of burst pacing before sustained AF developed when compared with baseline conditions. Right atrial repolarization alternans was observed, but because of the development of 2/1 atrioventricular block with far-field ventricular interference, its threshold could not be precisely measured. Non-sustained AF was not observed at baseline, but appeared during the electrical remodelling in association with a decrease in both ERP and propagation velocity. CONCLUSION: We report here on the feasibility of measuring ERP, atrial repolarization alternans, and propagation velocity kinetics and their potential in predicting susceptibility to AF in a free-behaving model of pacing-induced AF using the standard pacemaker technology.
Resumo:
OBJECTIVES: The aim of this study was to evaluate the risk factors associated with Contegra graft (Medtronic Minneapolis, MN, USA) infection after reconstruction of the right ventricular outflow tract. METHODS: One hundred and six Contegra grafts were implanted between April 1999 and April 2010 for the Ross procedure (n = 46), isolated pulmonary valve replacement (n = 32), tetralogy of Fallot (n = 24), double-outlet right ventricle (n = 7), troncus arteriosus (n = 4), switch operation (n = 1) and redo of pulmonary valve replacement (n = 2). The median age of the patients was 13 years (range 0-54 years). A follow-up was completed in all cases with a median duration of 7.6 years (range 1.7-12.7 years). RESULTS: There were 3 cases of in-hospital mortality. The survival rate during 7 years was 95.7%. Despite the lifelong endocarditis prophylaxis, Contegra graft infection was diagnosed in 12 (11.3%) patients at a median time of 4.4 years (ranging from 0.4 to 8.7 years). Univariate analysis of preoperative, perioperative and postoperative variables was performed and the following risk factors for time to infection were identified: female gender with a hazard ratio (HR) of 0.19 (P = 0.042), systemic-to-pulmonary shunt (HR 6.46, P < 0.01), hypothermia (HR 0.79, P = 0.014), postoperative renal insufficiency (HR 11.97, P = 0.015) and implantation of permanent pacemaker during hospitalization (HR 5.29, P = 0.075). In 2 cases, conservative therapy was successful and, in 10 patients, replacement of the infected valve was performed. The Contegra graft was replaced by a homograft in 2 cases and by a new Contegra graft in 8 cases. Cox's proportional hazard model indicated that time to graft infection was significantly associated with tetralogy of Fallot (HR 0.06, P = 0.01), systemic-to-pulmonary shunt (HR 64.71, P < 0.01) and hypothermia (HR 0.77, P < 0.01). CONCLUSION: Contegra graft infection affected 11.3% of cases in our cohort, and thus may be considered as a frequent entity that can be predicted by both intraoperative and early postoperative factors. After the diagnosis of infection associated with the Contegra graft was confirmed, surgical treatment was the therapy of choice.
Resumo:
OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.
Resumo:
OBJECTIVE: We aim to explore how health surrogates of patients with dementia proceed in decision making, which considerations are decisive, and whether family surrogates and professional guardians decide differently. METHODS: We conducted an experimental vignette study using think aloud protocol analysis. Thirty-two family surrogates and professional guardians were asked to decide on two hypothetical case vignettes, concerning a feeding tube placement and a cardiac pacemaker implantation in patients with end-stage dementia. They had to verbalize their thoughts while deciding. Verbalizations were audio-recorded, transcribed, and analyzed according to content analysis. By experimentally changing variables in the vignettes, the impact of these variables on the outcome of decision making was calculated. RESULTS: Although only 25% and 31% of the relatives gave their consent to the feeding tube and pacemaker placement, respectively, 56% and 81% of the professional guardians consented to these life-sustaining measures. Relatives decided intuitively, referred to their own preferences, and focused on the patient's age, state of wellbeing, and suffering. Professional guardians showed a deliberative approach, relied on medical and legal authorities, and emphasized patient autonomy. Situational variables such as the patient's current behavior and the views of health care professionals and family members had higher impacts on decisions than the patient's prior statements or life attitudes. CONCLUSIONS: Both the process and outcome of surrogate decision making depend heavily on whether the surrogate is a relative or not. These findings have implications for the physician-surrogate relationship and legal frameworks regarding surrogacy. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND: Electrophysiological cardiac devices are increasingly used. The frequency of subclinical infection is unknown. We investigated all explanted devices using sonication, a method for detection of microbial biofilms on foreign bodies. METHODS AND RESULTS: Consecutive patients in whom cardiac pacemakers and implantable cardioverter/defibrillators were removed at our institution between October 2007 and December 2008 were prospectively included. Devices (generator and/or leads) were aseptically removed and sonicated, and the resulting sonication fluid was cultured. In parallel, conventional swabs of the generator pouch were performed. A total of 121 removed devices (68 pacemakers, 53 implantable cardioverter/defibrillators) were included. The reasons for removal were insufficient battery charge (n=102), device upgrading (n=9), device dysfunction (n=4), or infection (n=6). In 115 episodes (95%) without clinical evidence of infection, 44 (38%) grew bacteria in sonication fluid, including Propionibacterium acnes (n=27), coagulase-negative staphylococci (n=11), Gram-positive anaerobe cocci (n=3), Gram-positive anaerobe rods (n=1), Gram-negative rods (n=1), and mixed bacteria (n=1). In 21 of 44 sonication-positive episodes, bacterial counts were significant (>or=10 colony-forming units/mL of sonication fluid). In 26 sterilized controls, sonication cultures remained negative in 25 cases (96%). In 112 cases without clinical infection, conventional swab cultures were performed: 30 cultures (27%) were positive, and 18 (60%) were concordant with sonication fluid cultures. Six devices and leads were removed because of infection, growing Staphylococcus aureus, Streptococcus mitis, and coagulase-negative staphylococci in 6 sonication fluid cultures and 4 conventional swab cultures. CONCLUSIONS: Bacteria can colonize cardiac electrophysiological devices without clinical signs of infection.
Resumo:
Background- An elevated resting heart rate is associated with rehospitalization for heart failure and is a modifiable risk factor in heart failure patients. We aimed to examine the association between resting heart rate and incident heart failure in a population-based cohort study of healthy adults without pre-existing overt heart disease. Methods and Results- We studied 4768 men and women aged ≥55 years from the population-based Rotterdam Study. We excluded participants with prevalent heart failure, coronary heart disease, pacemaker, atrial fibrillation, atrioventricular block, and those using β-blockers or calcium channel blockers. We used extended Cox models allowing for time-dependent variation of resting heart rate along follow-up. During a median of 14.6 years of follow-up, 656 participants developed heart failure. The risk of heart failure was higher in men with higher resting heart rate. For each increment of 10 beats per minute, the multivariable adjusted hazard ratios in men were 1.16 (95% confidence interval, 1.05-1.28; P=0.005) in the time-fixed heart rate model and 1.13 (95% confidence interval, 1.02-1.25; P=0.017) in the time-dependent heart rate model. The association could not be demonstrated in women (P for interaction=0.004). Censoring participants for incident coronary heart disease or using time-dependent models to account for the use of β-blockers or calcium channel blockers during follow-up did not alter the results. Conclusions- Baseline or persistent higher resting heart rate is an independent risk factor for the development of heart failure in healthy older men in the general population.
Resumo:
A pacemaker, regularly emitting chemical waves, is created out of noise when an excitable photosensitive Belousov-Zhabotinsky medium, strictly unable to autonomously initiate autowaves, is forced with a spatiotemporal patterned random illumination. These experimental observations are also reproduced numerically by using a set of reaction-diffusion equations for an activator-inhibitor model, and further analytically interpreted in terms of genuine coupling effects arising from parametric fluctuations. Within the same framework we also address situations of noise-sustained propagation in subexcitable media.
Resumo:
We study the interaction between two independent nonlinear oscillators competing through a neutral excitable element. The first oscillator, completely deterministic, acts as a normal pacemaker sending pulses to the neutral element which fires when it is excited by these pulses. The second oscillator, endowed with some randomness, though unable to make the excitable element to beat, leads to the occasional suppression of its firing. The missing beats or errors are registered and their statistics analyzed in terms of the noise intensity and the periods of both oscillators. This study is inspired in some complex rhythms such as a particular class of heart arrhythmia.
Resumo:
Objective To determine the clinical and electrophysiological characteristics of patients with paroxysmal palpitations and neck pounding during sinus rhythm. Methods Clinical, electrocardiographic, and electrophysiological characteristics of six patients with paroxysmal palpitations and neck pounding during sinus rhythm were studied in basal conditions and when symptomatic. Response to treatment was observed. Results Baseline ECGs were normal (four patients) or had first degree atrioventricular block with intermittent PR shortening. During symptoms, narrow QRS rhythms were seen without visible P waves (three patients) or with P waves partially hidden in the QRS complex (three patients). Dual atrioventricular nodal pathways were found in all five patients who had electrophysiological studies. In these patients the slow pathway conduction time was long enough (mean (SD), 425 (121)¿ms) for ventricular activation after slow pathway conduction during sinus rhythm to coincide with the next atrial depolarisation, causing neck pounding during exercise (four patients) or at rest (two patients). Tachycardia was not induced in any patient. Medical treatment aggravated symptoms in three patients. A pacemaker was successfully used in two. Conclusions Neck pounding during sinus rhythm is a clinical manifestation of dual atrioventricular nodal pathways. Medical treatment may aggravate symptoms but a pacemaker may offer definitive relief.
Resumo:
A pacemaker, regularly emitting chemical waves, is created out of noise when an excitable photosensitive Belousov-Zhabotinsky medium, strictly unable to autonomously initiate autowaves, is forced with a spatiotemporal patterned random illumination. These experimental observations are also reproduced numerically by using a set of reaction-diffusion equations for an activator-inhibitor model, and further analytically interpreted in terms of genuine coupling effects arising from parametric fluctuations. Within the same framework we also address situations of noise-sustained propagation in subexcitable media.