885 resultados para Out-of-plane Loading


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental observations of self-organized behavior arising out of noise are also described, and details on the numerical algorithms needed in the computer simulation of these problems are given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pacemaker, regularly emitting chemical waves, is created out of noise when an excitable photosensitive Belousov-Zhabotinsky medium, strictly unable to autonomously initiate autowaves, is forced with a spatiotemporal patterned random illumination. These experimental observations are also reproduced numerically by using a set of reaction-diffusion equations for an activator-inhibitor model, and further analytically interpreted in terms of genuine coupling effects arising from parametric fluctuations. Within the same framework we also address situations of noise-sustained propagation in subexcitable media.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental observations of self-organized behavior arising out of noise are also described, and details on the numerical algorithms needed in the computer simulation of these problems are given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HYPOTHESIS: During total shoulder arthroplasty (TSA), humeral head subluxation may be difficult to manage. Furthermore, there is a risk for postoperative recurrence of subluxation, affecting the outcome of TSA. An accurate evaluation of the subluxation is necessary to evaluate this risk. Currently, subluxation is measured in 2 dimensions (2D), usually relative to the glenoid face. The goal of this study was to extend this measure to 3 dimensions (3D) to compare glenohumeral and scapulohumeral subluxation and to evaluate the association of subluxation with the glenoid version. MATERIALS AND METHODS: The study analyzed 112 computed tomography scans of osteoarthritic shoulders. We extended the usual 2D definition of glenohumeral subluxation, scapulohumeral subluxation, and glenoid version by measuring their orientation in 3D relative to the scapular plane and the scapular axis. We evaluated statistical associations between subluxation and version in 2D and 3D. RESULTS: Orientation of subluxation and version covered all sectors of the glenoid surface. Scapulohumeral subluxation and glenoid version were highly correlated in amplitude (R(2) = 0.71; P < .01) and in orientation (R(2) = 0.86; P < .01). Approximately every degree of glenoid version induced 1% of scapulohumeral subluxation in the same orientation of the version. Conversely, glenohumeral subluxation was not correlated to glenoid version in 2D or in 3D. CONCLUSIONS: Orientation of the humeral subluxation is rarely within the arbitrary computed tomography plane and should therefore be measured in 3D to detect out-of-plane subluxation. Scapulohumeral subluxation and glenoid version measured in 3D could bring valuable information for decision making during TSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate whether early mobilization after acute ischaemic stroke is better than delayed mobilization with regard to medical complications and if it is safe in relation to neurological function and cerebral blood flow. DESIGN: Randomized controlled pilot trial of early versus delayed mobilization out of bed with incidence of severe complications as the primary outcome. SETTING: Acute stroke unit in the neurology department of a University Hospital. PARTICIPANTS: Fifty patients after ischaemic stroke with a National Institutes of Health Stroke Scale (NIHSS) score >6 were recruited. INTERVENTION: All patients were treated with physiotherapy immediately after their admission. In the early protocol patients were mobilized out of bed after 52 hours, in the delayed protocol after seven days. RESULTS: Eight out of 50 randomized patients were excluded from the per-protocol analysis because of early transfer to other hospitals. There were 2 (8%) severe complications in the 25 early mobilization patients and 8 (47%) in the 17 delayed mobilization patients (P < 0.006). There were no differences in the total number of complications or in clinical outcome. In the 26 patients (62%) who underwent serial transcranial Doppler ultrasonography, no blood flow differences were found. CONCLUSION: We found an apparent reduction in severe complications and no increase in total complications with an early mobilization protocol after acute ischaemic stroke. No influence on neurological three-month outcomes or on cerebral blood flow was seen. These results justify larger trials comparing mobilization protocols with possibly even faster mobilization out of bed than explored here.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To measure the proportion of adult non-traumatic cardiac or respiratory arrest among calls for seizure to an emergency medical dispatch centre and to record whether known epileptic patients present cardiac or respiratory arrest together with seizure. METHODS: This 2-year prospective observational investigation involved the collection of tape recordings of all incoming calls to the emergency medical dispatch centre, in which an out-of-hospital non-traumatic seizure was the chief complaint in patients >18 years, in addition to the paramedics' records of all patients who presented with respiratory or cardiac arrest. The authors also recorded whether the bystander spontaneously mentioned to the dispatcher that the victim was known to have epilepsy. RESULTS: During the 24-month period, the call centre received 561 incoming calls for an out-of-hospital non-traumatic seizure in an adult. Twelve cases were classified as cardiac or respiratory arrest by paramedics. In one case, the caller spontaneously mentioned that the victim had a history of epilepsy. The proportion of cardiac or respiratory arrest among calls for seizure was 2.1%. CONCLUSION: Although these cases are rare, dispatchers should closely monitor seizure patients with the help of bystanders to exclude an out-of-hospital cardiac or respiratory arrest, in which case the dispatcher can offer telephone cardiopulmonary resuscitation advice until the paramedics arrive. Whenever the activity of the centre allows it and no new incoming call is on hold, this can be achieved by staying on the line with the caller or by calling back. A history of epilepsy should not modify the type of monitoring performed by the dispatcher as those patients may also have an arrest together with seizure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report is formatted to independently present four individual investigations related to similar web gap fatigue problems. Multiple steel girder bridges commonly exhibit fatigue cracking due to out-of-plane displacement of the web near the diaphragm connections. This fatigue-prone web gap area is typically located in negative moment regions of the girders where the diaphragm stiffener is not attached to the top flange. In the past, the Iowa Department of Transportation has attempted to stop fatigue crack propagation in these steel girder bridges by drilling holes at the crack tips. Other nondestructive retrofits have been tried; in a particular case on a two-girder bridge with floor beams, angles were bolted between the stiffener and top flange. The bolted angle retrofit has failed in the past and may not be a viable solution for diaphragm bridges. The drilled hole retrofit is often only a temporary solution, so a more permanent and effective retrofit is required. A new field retrofit has been developed that involves loosening the bolts in the connection between the diaphragm and the girders. Research on the retrofit has been initiated; however, no long-term studies of the effects of bolt loosening have been performed. The intent of this research is to study the short-term effects of the bolt loosening retrofit on I-beam and channel diaphragm bridges. The research also addressed the development of a continuous remote monitoring system to investigate the bolt loosening retrofit on an X-type diaphragm bridge over a number of months, ensuring that the measured strain and displacement reductions are not affected by time and continuous traffic loading on the bridge. The testing for the first three investigations is based on instrumentation of web gaps in a negative moment region on Iowa Department of Transportation bridges with I-beam, channel, and X-type diaphragms. One bridge of each type was instrumented with strain gages and deflection transducers. Field tests, using loaded trucks of known weight and configuration, were conducted on the bridges with the bolts in the tight condition and after implementing the bolt loosening retrofit to measure the effects of loosening the diaphragm bolts. Long-term data were also collected on the X-diaphragm bridge by a data acquisition system that collected the data continuously under ambient truck loading. The collected data were retrievable by an off-site modem connection to the remote data acquisition system. The data collection features and ruggedness of this system for remote bridge monitoring make it viable as a pilot system for future monitoring projects in Iowa. Results indicate that loosening the diaphragm bolts reduces strain and out-of-plane displacement in the web gap, and that the reduction is not affected over time by traffic or environmental loading on the bridge. Reducing the strain in the web gap allows the bridge to support more cycles of loading before experiencing fatigue, thus increase the service life of the bridge. Two-girder floor beam bridges may also exhibit fatigue cracking in girder webs.