Objectives: Epidemiological studies have shown a relationship between long-term use of proton pump inhibitors and bone metabolism. However, this relationship has not yet become established. The aim of the present study was to analyze the mechanical properties and bone mineral density (BMD) of rats that were subjected to long-term omeprazole use. Methods: Fifty wistar rats weighing between 200 and 240 g were divided equally into five groups: OMP300 (omeprazole intake at a dose of 300 moL/kg/day); OMP200 (200 moL/ kg/day); OMP40 (40 moL/kg/day); OMP10 (10 moL/kg/day); and Cont (control group; intake of dilution vehicle). The solutions were administered for 90 consecutive days. After the rats had been sacrificed, their BMD, the mechanical properties of the dissected femurs and their serum Ca++ levels were analyzed. Results: The BMD of the OMP300 group was lower than that of the controls (p = 0.006). There was no difference in comparing the OMP200, OMP40 and OMP10 groups with the controls. The maximum strength and rigidity of the femur did not differ in the experimental groups in comparison with the controls. The OMP300 group had a statistically lower serum Ca++ concentration than that of the controls (p = 0.049), but the other groups did not show any difference in relation to the controls. Conclusion: Daily intake of 300moL/kg/day of omeprazole decreased the BMD of the femur, but without changes to the rigidity and strength of the femur in adult rats. © 2

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biological properties and biocompatibility of bovine non-demineralized lyophilized and composite bones implanted in tibiae bone cavities and at the subcutaneous level. Twenty-four rats were used and sacrificed 15 and 45 days later. At the subcutaneous level, after 15 days an inflammatory reaction was seen around biomaterial particles with the presence of giant cells and at 45 days fibrous connective tissue had also developed. No signs of ectopic bone formation were observed at tibiae regions; more bone neoformation was observed at the control group (15 days) with 42.8% of the outer cortex layer against 22.6% at Orthogen and 25% at GenMix groups. At 45 days, correspondent values for bone neoformation were 62.5% at control, 26% at Orthogen, and 35% at GenMix groups, respectively. It can be concluded that both materials tested were biocompatible aiming to bone neoformation by their osteoconductive properties with no ectopic formation sites observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Caracara genus (Aves: Falconidae) is composed by species C. cheriway, ("Crested Caracara"), and C. plancus (Southern Caracara). This study aimed to describe in detail and compared the cranial osteology of C. cheriway and C. plancus, identifying osteological cranial characters for a future systematic work. The two common characters of Caracara species are: the projection of rostro parasphenoid reaches 50% of the distance from the occipital condyle to the pterygoid; the upper maxilla has about 4/9 of the total length of theskull, the symphysial portion of mandible occupies about 1/7 of its total length, the proximal portion of lacrimal bone ends in a rounded shape and has about 1/4 of the width of the distal portion. The unique characters of C. cheriway are: the interorbital width is about 1/2 of the parietal region, shows a frontal bone prominence; presence of lacrimal process of frontal bone; the proximal portion of the lacrimal bone reaches 1/5 of the distance from the orbital arc to the jugal bone; the distance between the distal portions of two lacrimal bones reach 5/6 of the parietal width, the ratio between the interorbital diameter and parietal region ranges from 2 times; the zygomatic process occupies about 40% of the distance between its origin in the skull and jugal bone. The unique characters of C. plancus are: the interorbital width is approximately 4/7 of the parietal width; show a rostral medial concavity; the proximal portion of the lacrimal bone is about 1/4 of the width of the distal; the proximal portion of the lacrimal bone reaches 1/7 of the distance from the orbital arc to the jugal bone; the distance between the distal portions of two lacrimal bones reaches 6/7 of the width parietal one; the ratio between the interorbital diameter and parietal region varies 1, 75 times, the zygomatic process occupies about 35% of the distance between its origin in the skull and jugal bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The saccadic paradigm has been used to investigate specific cortical networks involving visuospatial attention. We examined whether asymmetry in theta and beta band differentiates the role of the hemispheres during the execution of two different prosacadic conditions: a fixed condition, where the stimulus was presented at the same location; and a random condition, where the stimulus was unpredictable. Twelve healthy volunteers (3 male; mean age: 26.25) performed the task while their brain activity pattern was recorded using quantitative electroencephalography. We did not find any significant difference for beta, slow- and fast-alpha frequencies for the pairs of electrodes analyzed. The results for theta band showed a superiority of the left hemisphere in the frontal region when responding to the random condition on the right, which is related to the planning and selection of responses, and also a greater activation of the right hemisphere during the random condition, in the occipital region, related to the identification and recognition of patterns. These results indicate that asymmetries in the premotor area and the occipital cortex differentiate memory- and stimulus-driven tasks. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object. The anatomy of the occipital lobe convexity is so intricate and variable that its precise description is not found in the classic anatomy textbooks, and the occipital sulci and gyri are described with different nomenclatures according to different authors. The aim of this study was to investigate and describe the anatomy of the occipital lobe convexity and clarify its nomenclature. Methods. The configurations of sulci and gyri on the lateral surface of the occipital lobe of 20 cerebral hemispheres were examined in order to identify the most characteristic and consistent patterns. Results. The most characteristic and consistent occipital sulci identified in this study were the intraoccipital, transverse occipital, and lateral occipital sulci. The morphology of the transverse occipital sulcus and the intraoccipital sulcus connection was identified as the most important aspect to define the gyral pattern of the occipital lobe convexity. Conclusions. Knowledge of the main features of the occipital sulci and gyri permits the recognition of a basic configuration of the occipital lobe and the identification of its sulcal and gyral variations. (http://thejns.org/doi/abs/10.3171/2012.1.JNS11978)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a influência da espessura do osso cortical sobre a velocidade de propagação do ultrassom (in vitro). MÉTODO: Foram utilizadas 60 lâminas ósseas confeccionadas a partir do fêmur de bovinos, com diferentes espessuras, variando de 1 a 6mm (10 de cada). As medidas da velocidade do ultrassom foram realizadas por aparelho projetado para este fim, utilizando técnica subaquática e por contato direto com auxílio de gel de acoplamento. Os transdutores foram posicionados de duas maneiras diferentes; opostos entre si, com o osso entre eles, sendo a medida chamada de transversal; e, paralelos na mesma superfície cortical, sendo a medida chamada de axial. RESULTADOS: Com o modo de transmissão axial, a velocidade de propagação do ultrassom aumenta conforme a espessura do osso cortical aumenta, independente da distância entre os transdutores, até a espessura de 5mm, mantendo-se constante após. Não houve alteração da velocidade quando o modo de transmissão foi transversal. CONCLUSÃO: A velocidade de propagação do ultrassom aumenta com o aumento da espessura da cortical óssea, no modo de transmissão axial, até o momento em que a espessura supera o comprimento da onda, mantendo a velocidade constante a partir de então. Nível de Evidência: Estudo Experimental.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of bone is needed for high bone loss due to congenital deformities, trauma or neoplastic diseases. Commonly, orthopaedic surgical treatments are autologus or allogenic bone implant or prosthetic implant. A choice to the traditional approaches could be represented by tissue engineering that use cells (and/or their products) and innovative biomaterials to perform bone substitutes biologically active as an alternative to artificial devices. In the last years, there was a wide improvement in biology on stem cells potential research and in biomedical engineering through development of new biomaterials designed to resemble the physiological tissues. Tissue engineering strategies and smart materials aim together to stimulate in vivo bone regeneration. This approaches drive at restore not only structure integrity and/or function of the original tissue, but also to induce new tissue deposition in situ. An intelligent bone substitute is now designed like not only a scaffold but also as carrier of regeneration biomolecular signals. Biomimetics has helped to project new tissue engineered devices to simulate the physiological substrates architecture, such extracellular matrix (ECM), and molecular signals that drive the integration at the interface between pre-existing tissue and scaffold. Biomimetic strategies want to increase the material surface biological activity with physical modifications (topography) o chemical ones (adhesive peptides), to improve cell adhesion to material surface and possibly scaffold colonization. This study evaluated the effects of biomimetic modifications of surgical materials surface, as poly-caprolattone (PCL) and titanium on bone stem cells behaviour in a marrow experimental model in vitro. Two biomimetic strategies were analyzed; ione beam irradiation, that changes the surface roughness at the nanoscale, and surface functionalization with specific adhesive peptides or Self Assembled Monolayers (SAMs). These new concept could be a mean to improve the early (cell adhesion, spreading..) and late phases (osteoblast differentiation) of cell/substrate interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We usually perform actions in a dynamic environment and changes in the location of a target for an upcoming action require both covert shifts of attention and motor planning update. In this study we tested whether, similarly to oculomotor areas that provide signals for overt and covert attention shifts, covert attention shifts modulate activity in cortical area V6A, which provides a bridge between visual signals and arm-motor control. We performed single cell recordings in monkeys trained to fixate straight-ahead while shifting attention outward to a peripheral cue and inward again to the fixation point. We found that neurons in V6A are influenced by spatial attention demonstrating that visual, motor, and attentional responses can occur in combination in single neurons of V6A. This modulation in an area primarily involved in visuo-motor transformation for reaching suggests that also reach-related regions could directly contribute in the shifts of spatial attention necessary to plan and control goal-directed arm movements. Moreover, to test whether V6A is causally involved in these processes, we have performed a human study using on-line repetitive transcranial magnetic stimulation over the putative human V6A (pV6A) during an attention and a reaching task requiring covert shifts of attention and reaching movements towards cued targets in space. We demonstrate that the pV6A is causally involved in attention reorienting to target detection and that this process interferes with the execution of reaching movements towards unattended targets. The current findings suggest the direct involvement of the action-related dorso-medial visual stream in attentional processes, and a more specific role of V6A in attention reorienting. Therefore, we propose that attention signals are used by the V6A to rapidly update the current motor plan or the ongoing action when a behaviorally relevant object unexpectedly appears at an unattended location.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questa tesi valuta l’efficacia della tecnica delle griglie in titanio con osso particolato nella ricostruzione dei difetti alveolari tridimensionali ai fini della riabilitazione dentale implanto-protesica. Il primo studio ha considerato la metodica in termini di complicanze post-operatorie e di risultati implanto-protesici. Sono stati considerati 24 pazienti con difetti tridimensionali trattati con l’applicazione di 34 griglie di titanio e osso particolato e riabilitati protesicamente dopo circa 8-9 mesi. 4 su 34 griglie sono state rimosse prima dell’inserimento implantare (11.76% di fallimento totale); 20 su 34 griglie si sono esposte per deiscenza dei tessuti molli (58.82% di complicanze): 4 (11.77%) prima e 16 (47.05%) dopo le prime 4-6 settimane dall’intervento; in nessun caso il piano di trattamento implanto-protesico ha subito variazioni. Dopo un follow-up medio di 20 (3-48) mesi dal carico protesico, nessuno degli 88 impianti ha perso la propria osteo-integrazione (100% di sopravvivenza implantare), con un valore complessivo di successo implantare di 82.9%. Il secondo studio ha calcolato in termini volumetrici la ricostruzione ossea ottenuta con griglie e la sua corre-lazione con l’estensione dell’esposizione e la tempistica del suo verificarsi. Sono stati valutati 12 pazienti con 15 difetti alveolari. Per ciascun sito sono state studiate le immagini TC con un software dedicato per misurare i volumi in tre dimensioni: il volume di osso non formatosi rispetto a quanto pianificato, lacking bone volume (LBV), è stato calcolato sottraendo il volume di osso ricostruito, reconstructed bone volume (RBV) in fase di ri-entro chirurgico dal volume di osso pianificato pre-operativamente, planned bone volume (PBV). LBV è risultato direttamente proporzionale all’area di esposizione della griglia, con un valore del 16.3% di LBV per ogni cm2 di griglia esposta. Si sono evidenziate, inoltre, correlazioni positive tra LBV , la tempistica precoce di esposizione e il valore di PBV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this thesis was the study of the cement-bone interface in the tibial component of a cemented total knee prosthesis. One of the things you can see in specimens after in vivo service is that resorption of bone occurs in the interdigitated region between bone and cement. A stress shielding effect was investigated as a cause to explain bone resorption. Stress shielding occurs when bone is loaded less than physiological and therefore it starts remodeling according to the new loading conditions. µCT images were used to obtain 3D models of the bone and cement structure and a Finite Element Analysis was used to simulate different kind of loads. Resorption was also simulated by performing erosion operations in the interdigitated bone region. Finally, 4 models were simulated: bone (trabecular), bone with cement, and two models of bone with cement after progressive erosions of the bone. Compression, tension and shear test were simulated for each model in displacement-control until 2% of strain. The results show how the principal strain and Von Mises stress decrease after adding the cement on the structure and after the erosion operations. These results show that a stress shielding effect does occur and rises after resorption starts.