968 resultados para Osseointegrated dental implants


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rehabilitation of edentulous areas with osseointegrated dental implants is a well-documented, predictable procedure in the literature, with high success rates. However, the lack of bone at the recipient bed or proximity to anatomic structures limits the rehabilitation procedure especially at the posterior mandible. Thus, short implants are an alternative treatment for such cases of severe bone resorption. The purpose of this study was to review the success rate of short implants, especially those based in the posterior mandible and to show a clinical case. A literature review was made on electronic databases PubMed and Bireme with articles published between the years 2005 to 2012, using the keywords "short dental implants". It was concluded that the success rates of short implants are similar to those presented by conventional implants but still related to their geometry and surface treatment. Also, short implants can be considered as a viable alternative for the rehabilitation of severely resorbed jaws. However, many authors consider that more research is necessary when a short implant is compared to a long dental implant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The use of methods for tissue regeneration has been widely applied in Implantology, in clinical situations with disabilities or anatomical limitations that prevent the placement of osseointegrated dental implants. The evolution of the development of biomaterials revolutionized this therapeutic modality, facilitating the resolution of clinical cases with tissue deficiencies. Thus, this study aimed to describe a clinical case approaching the methods, techniques, and materials used in guided bone regeneration applied to Implantology. Case report: A clinical case of a patient who received a Morse taper dental implant (region 15) is described. The use of biomaterial and membrane on the buccal wall of the socket was required. After the osseointegration period, a reopening surgery was performed, and an immediate provisional implant was produced. After 2 months of follow-up, the final prosthesis was made involving other adjacent elements. Final considerations: The guided bone regeneration technique employed showed satisfactory performance. The patient was positive regarding esthetics and function. However, more controlled studies with longer follow-up period are needed for analyses of predictability

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The techniques of bone reconstruction for atrophic maxillae have been improved in order to promote bone tissue growth in both height and thickness. The grafts performed with use of autogenous bone is considered the gold standard by most researchers, for demonstrating osteogenic capacity and not to promote antigenic response. However, this type of grafting is not possible to get bone tissue in large quantity for extensive renovations. In recent years, alternatives have been researched to overcome the limitations of autogenous bone. Several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts which are obtained from individuals with different genetic load, but from the same species have been extensively used. They can be indicated in cases of arthrosplasty, surgical knee reconstruction, and large bone defects as well as in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. To rehabilitate atrophic maxillae an option that has been performed with high success rate is the reconstruction with bone graft followed by osseointegrated dental implants to rehabilitate the patient aesthetics and functionally. This paper aims to show the feasibility of allogenic bone as material for reconstruction of atrophic maxilla, and subsequent rehabilitation with metal ceramic fixed prosthesis implant and dental restoration with accompanying three years through literature review and clinical case report.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il presente lavoro parte dalla descrizione dei processi di rimodellamento osseo mascellare a seguito della perdita di elementi dentari e la successiva riabilitazione mediante impianto dentale osteointegrato. Approfondiremo proprio i complessi aspetti dell’osteointegrazione su superfici implantari in titanio sia a livello micro che macroscopico. Nel campo dell’implantologia, infatti, il titanio risulta essere il materiale maggiormente impiegato in virtù della sua eccellente biocompatibilità e resistenza. Successivamente prenderemo in analisi i trattamenti di superficie implantare ad oggi più diffusi, lavorati prevalentemente a livello microscopico e infine confronteremo una sistematica trattata tradizionalmente con una innovativa trattata superficialmente a livello nanometrico. Il confronto avverrà in vivo, paragonando i risultati ottenuti clinicamente e radiograficamente tra le 2 sistematiche implantari, utilizzate per ripristinare la funzione masticatoria nei pazienti arruolati.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid-etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well-established animal model with a split-mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone-implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA-surfaced implants were 8-21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone-implant interfacial stiffness calculated from the torque-rotation curve was on average 9-14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate whether systemic diseases with/without systemic medication increase the risk of implant failure and therefore diminish success and survival rates of dental implants. MATERIALS AND METHODS: A MEDLINE search was undertaken to find human studies reporting implant survival in subjects treated with osseointegrated dental implants who were diagnosed with at least one of 12 systemic diseases. RESULTS: For most conditions, no studies comparing patients with and without the condition in a controlled setting were found. For most systemic diseases there are only case reports or case series demonstrating that implant placement, integration, and function are possible in affected patients. For diabetes, heterogeneity of the material and the method of reporting data precluded a formal meta-analysis. No unequivocal tendency for subjects with diabetes to have higher failure rates emerged. The data from papers reporting on osteoporotic patients were also heterogeneous. The evidence for an association between osteoporosis and implant failure was low. Nevertheless, some reports now tend to focus on the medication used in osteoporotic patients, with oral bisphosphonates considered a potential risk factor for osteonecrosis of the jaws, rather than osteoporosis as a risk factor for implant success and survival on its own. CONCLUSIONS: The level of evidence indicative of absolute and relative contraindications for implant therapy due to systemic diseases is low. Studies comparing patients with and without the condition in a controlled setting are sparse. Especially for patients with manifest osteoporosis under an oral regime of bisphosphonates, prospective controlled studies are urgently needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A tightly attached keratinized mucosa around endosseous dental implants is believed to be protective against peri-implant bone loss. Tension caused by buccal frena and mobile non keratinized mucosa is to avoid. This case report documents the optimization of peri-implant mucosal conditions in the upper and lower jaw. At the time of second stage surgery (re-entry) at submucosally osseointegrated dental implants an enlargement of keratinized mucosa and a thickening of soft tissue was obtained administrating a vestibuloplasty combined by a free gingival graft or a vestibuloplasty combined by an apically moved flap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the possibility of obtaining guided bone regeneration using a poly-tetrafluoroethylene (PTFE) nonporous barrier for 2 endosseous implants, partially inserted in tibiae of rabbits.Materials and Methods: Histologic characteristics of the interface between titanium implants (one group with titanium plasma-coated implants and the other group with acid-treated surfaces) and of the regenerated bone were also studied. Twenty screw-vent implants were placed in tibiae of 5 male New Zealand rabbits, 2 at the right side and 2 at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. At the experimental group the implants were with a PTFE nonporous barrier, whereas no barriers were used in contralateral implants. Animals were sacrificed 3 months after surgery and biopsy specimens were evaluated histologically and histomorphometrically under light microscopy. Student's t test was used for statistical analysis.Results: The histologic measurements showed a mean gain in bone height of 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control group, for the titanium plasma-spray and acid-treated implant surfaces, respectively.Conclusion: The results of the investigation revealed that the placement of implants protruding 3 nun from crestal bone defects may result in vertical bone augmentation using a nonporous PTFE barrier. (Implant Dent 2009;18:182-191)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate bone healing around dental implants with established osseointegration in experimental diabetes mellitus (DM) and insulin therapy by histomorphometric and removal torque analysis in a rat model. Materials and methods: A total of 80 male Wistar rats received a titanium implant in the tibiae proximal methaphysis. After a healing period of 60 days, the rats were divided into four groups of 20 animals each: a 2-month control group, sacrificed at time (group A), a diabetic group (group D), an insulin group (group I), and a 4-month control group (group C), subdivided half for removal torque and half for histomorphometric analysis. In the D and I groups the DM was induced by a single injection of 40 mg/kg body weight streptozotocin (STZ). Two days after DM induction, group I received subcutaneous doses of insulin twice a day, during 2 months. Groups C and D received only saline. Two months after induction of DM, the animals of groups D, C and I were sacrificed. The plasmatic levels of glucose (GPL) were monitored throughout the experiment. Evaluation of the percentages of bone-to-implant contact and bone area within the limits of the implant threads was done by histomorphometric and mechanical torque analysis. Data were analyzed by anova at significant level of 5%. Results: The GPL were within normal range for groups A, C and I and higher for group D. The means and standard deviations (SD) for histomorphometric bone area showed significant difference between group D (69.34 ± 5.00%) and groups C (78.20 ± 4.88%) and I (79.63 ± 4.97%). Related to bone-to-implant contact there were no significant difference between the groups D (60.81 + 6.83%), C (63.37 + 5.88%) and I (66.97 + 4.13%). The means and SD for removal torque showed that group D (12.91 ± 2.51 Ncm) was statistically lower than group I (17.10 ± 3.06 Ncm) and C (16.95 ± 5.39 Ncm). Conclusions: Diabetes mellitus impaired the bone healing around dental implants with established osseointegration because the results presented a lower percentage of bone area in group D in relation to groups C and I resulting in a lowest torque values for implant removal. Moreover, insulin therapy prevents the occurrence of bone abnormalities found in diabetic animals and osseointegration was not compromised. © 2012 John Wiley & Sons A/S.