932 resultados para Ophthalmic Optics and Devices
Resumo:
Digital holographic microscopy (DHM) is a technique that allows obtaining, from a single recorded hologram, quantitative phase image of living cell with interferometric accuracy. Specifically the optical phase shift induced by the specimen on the transmitted wave front can be regarded as a powerful endogenous contrast agent, depending on both the thickness and the refractive index of the sample. Thanks to a decoupling procedure cell thickness and intracellular refractive index can be measured separately. Consequently, Mean corpuscular volume (MCV) and mean corpuscular hemoglobin concentration (MCHC), two highly relevant clinical parameters, have been measured non-invasively at a single cell level. The DHM nanometric axial and microsecond temporal sensitivities have permitted to measure the red blood cell membrane fluctuations (CMF) on the whole cell surface. ©2009 COPYRIGHT SPIE--The International Society for Optical Engineering.
Resumo:
BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.
Resumo:
La televisió està en crisi. Les noves tecnologies i els dispositius han fragmentat les audiències de televisió en segments més petits. En aquest informe, Marissa Gluck i Meritxell Roca Sales examinen l'explosió dels mitjans de comunicació que han impulsat aquesta fragmentació.
Resumo:
Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE
Resumo:
Colorectal cancer is a heterogeneous disease that manifests through diverse clinical scenarios. During many years, our knowledge about the variability of colorectal tumors was limited to the histopathological analysis from which generic classifications associated with different clinical expectations are derived. However, currently we are beginning to understand that under the intense pathological and clinical variability of these tumors there underlies strong genetic and biological heterogeneity. Thus, with the increasing available information of inter-tumor and intra-tumor heterogeneity, the classical pathological approach is being displaced in favor of novel molecular classifications. In the present article, we summarize the most relevant proposals of molecular classifications obtained from the analysis of colorectal tumors using powerful high throughput techniques and devices. We also discuss the role that cancer systems biology may play in the integration and interpretation of the high amount of data generated and the challenges to be addressed in the future development of precision oncology. In addition, we review the current state of implementation of these novel tools in the pathological laboratory and in clinical practice.
Resumo:
PURPOSE: To describe the clinical presentation of cutaneous benign mixed tumor of the eyelid and its management options. METHODS: Periocular cases of cutaneous benign mixed tumor were gathered from members of an oculoplastics specialty Internet discussion group. A total of 9 patients are described in this retrospective, interventional case series. The clinical presentation, histopathology, and management of these lesions is reviewed. RESULTS: Patients were typically asymptomatic, presenting with a slowly enlarging, nontender nodule of 2 to 8 years' duration. The lesions ranged from 4 mm to 17 mm in greatest dimension. Four of the lesions were on the eyelid margin, three in the sub-brow area of the upper eyelid, and two in the central lids. All six cases not involving the brow were fixed to the tarsus; one brow lesion was believed to be adherent to the skin. None of the lesions was associated with significant changes of the overlying epidermis, although one lesion showed overlying pigmentation. All patients underwent excisional biopsy for diagnostic or cosmetic reasons. On histopathologic examination, the tumors were biphasic, with an epithelial component exhibiting apocrine or hair follicle differentiation and a myxoid, adipocytic, chondroid, and/or fibrous stroma. The pathologic diagnoses were all consistent with cutaneous benign mixed tumor (chondroid syringoma, pleomorphic adenoma). Follow-up ranged from 2 weeks to 12 months, although several patients failed to keep scheduled follow-up appointments. No clinical recurrences were identified. CONCLUSIONS: Cutaneous benign mixed tumor may occur in the eyelid, and, although uncommon, should be included in the differential diagnosis of firm, nodular eyelid tumors. The histopathologic features are similar to those seen in this tumor type arising in other areas of the body. Preoperative consideration of this diagnostic possibility may allow the surgeon to plan for complete excision, thereby reducing the possibility of recurrence or malignant transformation.
Resumo:
The kinetics of binding of a glycolipid-anchored protein (the promastigote surface protease, PSP) to planar lecithin bilayers is studied by an integrated optics technique, in which the bilayer membrane is supported on an optical wave guide and the phase velocities of guided light modes in the wave guide are measured. From these velocities, the optical parameters of the membrane and PSP layers deposited on the waveguide are determined, yielding in particular the mass of PSP bound to the membrane, which is followed in real time. From a comparison of the binding rates of PSP and PSP from which the lipid moiety has been removed, it is shown that the lipid moiety plays a key role in anchoring the protein to the membrane. Specific and nonspecific binding of antibodies to membrane-anchored PSP is also investigated. As little as a fifth of a monolayer of PSP is sufficient to suppress the appreciable nonspecific binding of antibodies to the membrane.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.
Resumo:
Perceived patient value is often not aligned with the emerging expenses for health care services. In other words, the costs are often supposed as rising faster than the actual value for the patients. This fact is causing major concerns to governments, health plans, and individuals. Attempts to solve the problem have habitually been on the operational effectiveness side: increasing patient volume, minimizing costs, rationing, or closing hospitals, usually resulting in a zero-sum game. Only few approaches come from the strategic positioning side and "competition" among hospitals is still perceived rather as a danger than as a chance to create a positive-sum game and stimulate patient value. In their 2006 book, "Redefining Health Care", the renowned Harvard strategy professor Michael E. Porter and hospital management expert Professor Elizabeth Olmsted Teisberg approach the challenge from the positive-sum perspective: they propose to form Integrated Practice Units (IPUs) and manage hospitals in a modern, patient value oriented way. They argue that creating value-based competition on results should have the same effect on the health care sector like transparency and competition turned other industries with out-dated management models (like recently the inert telecommunication industry) into highly competitive and customer value creating businesses. The objective of this paper is to elaborate Care Delivery Value Chains for Integrated Practice Units in ophthalmic clinics and gather a first feedback from Swiss hospital managers, ophthalmologists, and patients, if such an approach could be a realistic way to improve health care management. First, Porter's definition of competitiveness (distinction between operational effectiveness and strategic positioning) is explained. Then, the Care Delivery Value Chain is introduced as a key element for understanding value-based management, followed by three practice examples for ophthalmic clinics. Finally, recommendations are given how the Care Delivery Value Chain can be managed efficiently and how the obstacles of becoming a patient-oriented organization can be overcome. The conclusion is that increased transparency and value-based competition on results has the potential to change the mindset of hospital managers-which will align patient value with the emerging health care expenses. Early adapters of this management approach will gain a competitive advantage. [Author, p. 6]
Resumo:
We present here the first part of the literature review regarding our study object, the Open Device Labs. The research on ODLs emerges from the observation of worldwide non-profit movement, which, through mutual collaboration, information and devices sharing, proposes a final improvement on user’s experience with the web and app.
Resumo:
Technological developments in microprocessors and ICT landscape have made a shift to a new era where computing power is embedded in numerous small distributed objects and devices in our everyday lives. These small computing devices are ne-tuned to perform a particular task and are increasingly reaching our society at every level. For example, home appliances such as programmable washing machines, microwave ovens etc., employ several sensors to improve performance and convenience. Similarly, cars have on-board computers that use information from many di erent sensors to control things such as fuel injectors, spark plug etc., to perform their tasks e ciently. These individual devices make life easy by helping in taking decisions and removing the burden from their users. All these objects and devices obtain some piece of information about the physical environment. Each of these devices is an island with no proper connectivity and information sharing between each other. Sharing of information between these heterogeneous devices could enable a whole new universe of innovative and intelligent applications. The information sharing between the devices is a diffcult task due to the heterogeneity and interoperability of devices. Smart Space vision is to overcome these issues of heterogeneity and interoperability so that the devices can understand each other and utilize services of each other by information sharing. This enables innovative local mashup applications based on shared data between heterogeneous devices. Smart homes are one such example of Smart Spaces which facilitate to bring the health care system to the patient, by intelligent interconnection of resources and their collective behavior, as opposed to bringing the patient into the health system. In addition, the use of mobile handheld devices has risen at a tremendous rate during the last few years and they have become an essential part of everyday life. Mobile phones o er a wide range of different services to their users including text and multimedia messages, Internet, audio, video, email applications and most recently TV services. The interactive TV provides a variety of applications for the viewers. The combination of interactive TV and the Smart Spaces could give innovative applications that are personalized, context-aware, ubiquitous and intelligent by enabling heterogeneous systems to collaborate each other by sharing information between them. There are many challenges in designing the frameworks and application development tools for rapid and easy development of these applications. The research work presented in this thesis addresses these issues. The original publications presented in the second part of this thesis propose architectures and methodologies for interactive and context-aware applications, and tools for the development of these applications. We demonstrated the suitability of our ontology-driven application development tools and rule basedapproach for the development of dynamic, context-aware ubiquitous iTV applications.
Resumo:
The objective of the study was to determine the association between clinical ophthalmic alterations and seroreactivity to leptospirosis by serovar Icterohaemorrhagiae in horses in Rio de Janeiro, Brazil. A total of 199 horses were studied. A microscopic agglutination test (MAT) was used to detect specific anti-Leptospira antibodies in blood serum. A total of 107 (53.8%) horses were seroreactive (titres > 200); 54 had high (> 800) titres, of which 44 were against serovar Icterohaemorrhagiae. Forty-two out of these 44, plus 40 seronegative horses (titers < 100) were given detailed ophthalmic examinations. Epiphora, ocular congestion, blepharospasm, photophobia, and peripapillary focal depigmentation were the most frequent alterations in seroreactive horses. Most ocular alterations were significantly more frequent in seroreactive horses. Horses seroreactive for leptospirosis (serovar Icterohaemorrhagiae) had a significantly higher prevalence of ophthalmic alterations than seronegative horses, providing additional evidence for an association between leptospirosis and equine uveitis.
Resumo:
In the 70's, pancreatic islet transplantation arose as an attractive alternative to restore normoglycemia; however, the scarcity of donors and difficulties with allotransplants, even under immunosuppressive treatment, greatly hampered the use of this alternative. Several materials and devices have been developed to circumvent the problem of islet rejection by the recipient, but, so far, none has proved to be totally effective. A major barrier to transpose is the highly organized islet architecture and its physical and chemical setting in the pancreatic parenchyma. In order to tackle this problem, we assembled a multidisciplinary team that has been working towards setting up the Human Pancreatic Islets Unit at the Chemistry Institute of the University of São Paulo, to collect and process pancreas from human donors, upon consent, in order to produce purified, viable and functional islets to be used in transplants. Collaboration with the private enterprise has allowed access to the latest developed biomaterials for islet encapsulation and immunoisolation. Reasoning that the natural islet microenvironment should be mimicked for optimum viability and function, we set out to isolate extracellular matrix components from human pancreas, not only for analytical purposes, but also to be used as supplementary components of encapsulating materials. A protocol was designed to routinely culture different pancreatic tissues (islets, parenchyma and ducts) in the presence of several pancreatic extracellular matrix components and peptide growth factors to enrich the beta cell population in vitro before transplantation into patients. In addition to representing a therapeutic promise, this initiative is an example of productive partnership between the medical and scientific sectors of the university and private enterprises.
Resumo:
Modern automobiles are no longer just mechanical tools. The electronics and computing services they are shipping with are making them not less than a computer. They are massive kinetic devices with sophisticated computing power. Most of the modern vehicles are made with the added connectivity in mind which may be vulnerable to outside attack. Researchers have shown that it is possible to infiltrate into a vehicle’s internal system remotely and control the physical entities such as steering and brakes. It is quite possible to experience such attacks on a moving vehicle and unable to use the controls. These massive connected computers can be life threatening as they are related to everyday lifestyle. First part of this research studied the attack surfaces in the automotive cybersecurity domain. It also illustrated the attack methods and capabilities of the damages. Online survey has been deployed as data collection tool to learn about the consumers’ usage of such vulnerable automotive services. The second part of the research portrayed the consumers’ privacy in automotive world. It has been found that almost hundred percent of modern vehicles has the capabilities to send vehicle diagnostic data as well as user generated data to their manufacturers, and almost thirty five percent automotive companies are collecting them already. Internet privacy has been studies before in many related domain but no privacy scale were matched for automotive consumers. It created the research gap and motivation for this thesis. A study has been performed to use well established consumers privacy scale – IUIPC to match with the automotive consumers’ privacy situation. Hypotheses were developed based on the IUIPC model for internet consumers’ privacy and they were studied by the finding from the data collection methods. Based on the key findings of the research, all the hypotheses were accepted and hence it is found that automotive consumers’ privacy did follow the IUIPC model under certain conditions. It is also found that a majority of automotive consumers use the services and devices that are vulnerable and prone to cyber-attacks. It is also established that there is a market for automotive cybersecurity services and consumers are willing to pay certain fees to avail that.