750 resultados para Occlusal sealants
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To evaluate the influence of examiner's clinical experience on detection and treatment decision of caries lesions in primary molars. Design Three experienced dentists (Group A) and three undergraduate students (Group B) used the International Caries Detection and Assessment System (ICDAS) criteria and bitewing radiographs (BW) to perform examinations twice in 77 primary molars that presented a sound or carious occlusal surface. For the treatment decision (TD), the examiners attributed scores, analyzing the teeth in conjunction with the radiographs. The presence and the depth of lesion were validated histologically, and reproducibility was evaluated. The sensitivity, specificity, accuracy, and area under the ROC curve values were calculated for ICDAS and BW. The associations between ICDAS, BW, and TD were analyzed by means of contingency tables. Results Interexaminer agreement for ICDAS, BW, and TD were excellent for Group B and moderate for Group A. The two groups presented similar and satisfactory performance for caries lesion detection using ICDAS and BW. In the treatment decision, Group A was shown to have a less invasive approach than Group B. Conclusion The examiner's experience was not determinant for the clinical and radiographic detection of occlusal lesions in primary teeth but influenced the treatment decision of initial lesions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to analyze the anticaries potential of pit and fissure sealants containing amorphous calcium phosphate (ACP) by synchrotron microtomography. Bovine enamel blocks (4x4 mm; n=50) were selected through surface hardness (Knoop) analysis. Slabs were obtained through cross-sections taken 1 mm from the border of the enamel. Five indentations, spaced 100 mu m apart, were made 300 mu m from the border. Ten specimens were prepared for each tested material (Ultraseal XT plus TM, Aegis, Embrace, Vitremer and Experimental Sealant). The materials were randomly attached to the sectioned surfaces of the enamel blocks and fixed with sticky wax. The specimens were submitted to pH cycling. After that, the surface hardness (SH1) was determined, and the blocks were submitted to synchrotron microcomputed tomography analysis to calculate the mineral concentration (Delta g(HAp) cm(-3)) at different areas of the enamel. The comparison between the SH1 and DgHAp cm(-3) showed a correlation for all groups (r=0.840; p<0.001). The fluoride groups presented positive values of DgHAp cm(-3), indicating a mineral gain that was observed mainly in the outer part of the enamel. The ACP showed mineral loss in the outer enamel compared with fluoride groups, although it inhibited the demineralization in the deeper areas of enamel. The combination of two remineralizing agents (fluoride and ACP) was highly effective in preventing demineralization.
Resumo:
This study evaluated the effect of different dentifrices on the microhardness and surface roughness of composite surfaces covered by surface sealants. Samples of Filtek P60 were made and divided into groups, in accordance with surface treatments: G1 - Fortify; G2 - Fortify Plus; G3 - control (none). For Knoop microhardness evaluation, the specimens were placed in a microdurometer, under a load of 50 g for 15 sec. The analyses of surface roughness were carried out individually in a profilometer. The specimens were submitted to toothbrushing using dentifrices: Colgate Maximum Protection Anti-caries, Colgate Whitening or Sensodyne, diluted in distilled water (1:3) for 30 000 cycles. The results showed that the control group (G3) presented the highest microhardness values. The control group presented, before toothbrushing, the lowest surface roughness values, and after toothbrushing there were no differences among the experimental groups. The maintenance of the lowest values of microhardness demonstrated the effectiveness of these sealant materials to support the abrasive wear.
Resumo:
The aim of the present study was to evaluate the effect of the use of an occlusal splint in children with bruxism in a pilot study with a short-term follow up. Seventeen children were recruited, only nine of whom formed the sample following the application of the inclusion criteria: presence of sleep bruxism for at least six months (based on parents' reports); presence of at least the first permanent molars; and no previous history of treatment involving an occlusal splint. The sample was submitted to a clinical exam. Other sleep problems were screened with the use of a sleep questionnaire filled out by parents before and after 90 days of occlusal splint usage. The children received a flat acrylic resin splint with full coverage of the occlusal surfaces to be worn in the maxilla. In children with erupting teeth, a space was created in the splint to allow normal eruption. After the 90-day period, the absence of sleep bruxism and sleep movements was noted in most of children. Moreover, snoring was reduced in nearly 50%, which raises a new issue to be investigated with regard to the pathophysiology of sleep bruxism. The use of an occlusal splint was effective in reducing the symptoms of sleep bruxism and other sleep problems. Further investigations should be carried out on the relationship between snoring and sleep bruxism in children.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental wear and subsequent occlusal interferences.
Resumo:
The aim of this prospective and blind clinical trial was to assess the effectiveness of sealing localized marginal defects of amalgam restoration that were initially scheduled to be replaced. A cohort of twenty six patients with 60 amalgam restorations (n=44Class I and n=16Class II), that presented marginal defects deviating from ideal (Bravo) according to USPHS criteria, were assigned to either sealing or replacement groups: A: sealing n=20, Replacement n=20, and no treatment (n=20). Two blind examiners evaluated the restorations at baseline (K=0.74) and after ten years (K=0.84) according with USPHS criteria, in four parameters: marginal adaptation (MA), secondary caries (SC), marginal staining (MS) and teeth sensitivity (TS). Multiple comparison of restorations degradation/upgrade was analyzed by Friedman test and the comparisons within groups were performed by Wilcoxon test. After 10 years, 44 restorations were assessed (73.3%), Group A: n=14 and Group B: n=16; and Group C: n=14 sealing and replacement amalgam restorations presented similar level of quality in MA (p=0.76), SC (p=0.25) and TS (p=0.52), while in MS (p=0.007) presented better performance in replacement group after 10-years. Most of the occlusal amalgam restorations with marginal gaps showed similar long term outcomes than the restorations were sealed, replaced, or not treated over a 10-year period. Most of the restorations of the three groups were clinically acceptable, under the studied parameters. All restorations had the tendency to present downgrade/deterioration over time.