928 resultados para Objective assessment
Resumo:
.:Abstract-Objective: Bioelectrical impedance analysis (BIA) is widely used as bedside assessment of body composition. Body cell mass (BCM) and intracellular water (ICW) are clinically important body compartments. Estimates of ICW obtained from BIA by different calculation approaches were compared to a reference method in male HIV-infected patients. Patients: Representative subsample of clinically stable HIV-infected outpatients, consisting of 42 men with a body mass index of 22.4 +/- 3.8 kg/m(2) (range, 13-31 kg/m(2)). Methods: Total body potassium was assessed in a whole body counter, and compared to 50 kHz mono-frequency BIA and multifrequency bioelectrical impedance spectroscopy. Six different prediction equations for ICW from BIA data were applied. Methods were compared by the Bland-Altman method. Results: BIA-derived ICW estimates explained 58% to 73% of the observed variance in ICW (TBK), but limits of confidence were wide (-16.6 to +18.2% for the best method). BIA overestimated low ICW (TBK) and underestimated high ICW (TBK) when normalized for weight or height. Mono- and multifrequency BIA were not different in precision but population-specific equations tended to narrower confidence limits. Conclusion: BIA is an unreliable method to estimate ICW in this population, in contrast to the better established estimation of total body water and extracellular water. Potassium depletion in severe malnutrition may contribute to this finding but a major part of the residual between methods remains unexplained. (C) 2000 Harcourt Publishers Ltd.
Resumo:
Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.
Resumo:
Background: A combination of antihypertensive agents of different drug classes in a fixed-dose combination (FDC) may offer advantages in terms of efficacy, tolerability, and treatment compliance. Combination of a calcium channel blocker with an angiotensin-converting enzyme inhibitor may act synergistically to reduce blood pressure (BP). Objective: The aim of this study was to compare the efficacy and tolerability of an amlodipine/ramipril FDC with those of amlodipine monotherapy. Methods: This 18-week, prospective, randomized, double-blind study was conducted at 8 centers across Brazil. Patients with stage 1 or 2 essential hypertension were enrolled. After a 2-week placebo run-in phase, patients received amlodipine/ramipril 2.5/2.5 mg or amlodipine 2.5 mg, after which the doses were titrated, based on BP, to 515 then 10/10 mg (amlodipme/ramipril) and 5 then 10 mg (amiodipine). The primary end point was BP measured in the intent-to-treat (ITT) population. Hematology and serum biochemistry were assessed at baseline and study end. Tolerability was assessed using patient interview, laboratory analysis, and physical examination, including measurement of ankle circumference to assess peripheral edema. Results: A total of 222 patients completed the study (age range, 40-79 years; FDC group, 117 patients [mean dose, 7.60/7.60 mg]; monotherapy, 105 patients [mean dose, 7.97 mg]). The mean (SD) changes in systolic BP (SBP) and diastolic BP (DBP), as measured using 24-hour ambulatory blood pressure monitoring (ABPM) and in the physician`s office, were significantly greater with combination therapy than monotherapy, with the exception of office DBP (ABPM, -20.76 [1.25] vs -15.80 [1.18] mm Hg and -11.71 [0.78] vs -8.61 [0.74] mm Hg, respectively [both, P = 0.004]; office, -27.51 [1.40] vs -22.84 [1.33] min Hg [P = 0.012] and -16.41 [0.79] vs -14.64 [0.75] mm Hg [P = NS], respectively). In the ITT analysis, the mean changes in ambulatory, but not office-based, BP were statistically significant (ABPM: SBP, -20.21 [1.14] vs -15.31 [1.12] mm Hg and DBP, -11.61 [0.72] vs -8.42 [0.70] mm Hg, respectively [both, P = 0.002]; office: SBP, -26.60 [1.34] vs -22.97 [1.30] mm Hg and DBP, -16.48 [0.78] vs -14.48 [0.75] mm Hg [both, P = NS]). Twenty-nine patients (22.1%) treated with combination therapy and 41 patients (30.6%) treated with monotherapy experienced >= 1 adverse event considered possibly related to study drug. The combmation-therapy group had lower prevalence of edema (7.6% vs 18.7%; P = 0.011) and a similar prevalence of dry cough (3.8% vs 0.8%; P = NS). No clinically significant changes in laboratory values were found in either group. Conclusions: In this population of patients with essential hypertension, the amlodipine/ramipril FDC was associated with significantly reduced ambulatory and office-measured BP compared with amlodipine monotherapy, with the exception of office DBP. Both treatments were well tolerated. (Clin Ther. 2008;30: 1618-1628) (C) 2008 Excerpta Medica Inc.
Resumo:
Dysphagia is a symptom associated with an array of anatomical and functional changes which must be assessed by a multidisciplinary team to guarantee optimal evaluation and treatment, preventing potential complications. Aim: The aim of the present study is to present the combined protocol of clinical and swallowing videoendoscopy carried by ENT doctors and speech therapists in the Dysphagia Group of the ENT Department - University Hospital. Materials and Methods: Retrospective study concerning the use of a protocol made up of patient interview and clinical examination, followed by an objective evaluation with swallowing videoendoscopy. The exam was performed in 1,332 patients from May 2001 to December 2008. There were 726 (54.50%) males and 606 (45.50%) females, between 22 days and 99 years old. Results: We found: 427 (32.08%) cases of normal swallowing, 273 (20.48%) mild dysphagia, 224 (16.81%) moderate dysphagia, 373 (27.99%) severe dysphagia and 35 (2.64%) inconclusive exams. Conclusion: The combined protocol (Otolaryngology and Speech Therapy), is a good way to approach the dysphagic patient, helping to achieve early and safe deglutition diagnosis as far as disorder severity and treatment are concerned.
Resumo:
Objective: This analysis of the Lipid Treatment Assessment Project 2 population compared lipid goal attainment by diabetes and metabolic syndrome status. Research design and methods: Dyslipidaemic patients aged >= 20 years on stable lipid lowering therapy had their lipid levels determined once during enrolment at investigation sites in nine countries between September 2006 and April 2007. Achievement of low-density lipoprotein (LDL) cholesterol success, triglycerides < 150 mg/dl (1.7 mmol/l), and high-density lipoprotein (HDL) cholesterol success (> 40 mg/dl [1.0 mmol/l] in men or > 50 mg/dl [1.3 mmol/l] in women) was compared using logistic regression. Results: A total of 9955 patients were evaluated. Patients with diabetes, compared with those without diabetes, had lower achievement of LDL cholesterol goals (according to National Cholesterol Education Program Adult Treatment Panel [NCEP ATP] III guidelines; 67% vs. 75%), triglycerides < 150 mg/dl (55% vs. 64%), and HDL cholesterol success (61% vs. 74%; p < 0.0001 for all comparisons). The significantly lower lipid goal attainment in patients with diabetes was consistent across participating world regions. Patients with metabolic syndrome, compared with those without metabolic syndrome, had lower achievement of NCEP ATP III LDL cholesterol goals (69% vs. 76%), triglycerides < 150 mg/dl (36% vs. 83%), and HDL cholesterol success (49% vs. 89%; p < 0.0001 for all comparisons). As the number of metabolic syndrome components increased, lipid success rates progressively decreased (p < 0.0001 for LDL cholesterol success, triglycerides < 150 mg/dl, and HDL cholesterol success). Conclusions: This analysis indicates that despite their increased cardiovascular risk, patients with diabetes or metabolic syndrome remain undertreated.
Resumo:
The objective of this prospective study was to perform a cross-cultural adaptation of the Functional Assessment Measure (FAM) into Brazilian Portuguese, and to assess the test-retest reliability. The instrument was translated, back-translated, pretested, and reviewed by a committee. The Brazilian version was assessed in 61 brain-injury patients. Intrarater and interrater reliability was verified by a test-retest procedure (intraclass correlation). Intrarater reliability was moderate-to-excellent; interrater reliability was moderate-to-excellent, with the exception of one item. The Brazilian version of the FAM has acceptable test-retest reliability. Results suggest the use of the Brazilian version of the FAM in the Brazilian population, for disability evaluation and outcome assessment. Further research is required to evaluate the psychometric properties of the scale. International Journal of Rehabilitation Research 34:89-91 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
OBJECTIVE: Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries is responsible for ischemic infarction and poor outcome. The goal of this study is to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition, we analyzed the incidence of perforating vessels involved during the aneurysm surgery and the incidence of ischemic infarct caused by compromised small arteries. METHODS: Sixty patients with 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co., Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries were analyzed in the microsurgical field during surgical dissection and clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography were considered for analysis. RESULTS: The ICGA was able to visualize flow in all patients in whom perforating vessels were found in the microscope field. Among 36 patients whose perforating vessels were visible on ICGA, 11 (30%) presented a close relation between the aneurysm and perforating arteries. In one (9%) of these 11 patients, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate reestablishment of flow visible with ICGA without clinical consequences. Four patients (6.7%) presented with postoperative perforating artery infarct, three of whom had perforating arteries that were not visible or distant from the aneurysm. CONCLUSION: The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA may provide visual information with regard to the patency of these small vessels.
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
Objective: To evaluate the accuracy of preoperative magnetic resonance imaging (MRI) findings relative to surgical presence of deeply infiltrating endometriosis (DIE). Methods: This prospective study included 92 women with clinical suspicion of DIE. The MR images were compared with laparoscopy and pathology findings. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI for diagnosis of DIE were assessed. Results: DIE was confirmed at histopathology in 77 of the 92 patients (83.7%). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MRI to diagnose DIE at each of the specific sites evaluated were as follows: retrocervical space (89.4%, 92.3%, 96.7%, 77.4%, 90.2%); rectosigmoid (86.0%, 92.9%, 93.5%, 84.8%, 89.1%); bladder (23.1%, 100%,100%, 88.8%, 89.1%); ureters (50.0%, 100%, 95.5%, 95.7%); and vagina (72.7%, 100%, 100%, 96.4%, 96.7%). Conclusion: MRI demonstrates high accuracy in diagnosing DIE in the retrocervical region, rectosigmoid. bladder, ureters, and vagina. (C) 2009 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Lid. All rights reserved.
Resumo:
The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)
Resumo:
Background: The assessment of activities of daily living (ADL) is important both for the diagnosis and staging of dementia. The objective of this study was to verify the applicability and validity of the Brazilian version of the Disability Assessment for Dementia (DAD-Br). Methods: The DAD was applied to caregivers of 89 patients with probable Alzheimer disease (AD) and to 40 elderly individuals without cognitive impairment (controls). We assessed the construct validity of the scale and its diagnostic accuracy (sensitivity, specificity, and predictive value). In addition, intergroup and intragroup analyses were conducted to characterize patient performance on basic and instrumental ADL and to determine underlying deficits (initiation, planning, or effective execution). Results: AD patients and controls had mean ages of 76.4 +/- 6.9 years and 74.5 +/- 7.3 years (P = 0.08), respectively. Mean Mini-Mental State Examination scores were 17.4 +/- 5.0 and 26.1 +/- 5.1 (P < 0.001) and scores on the DAD were 68.4 +/- 19.0 and 99.8 +/- 0.9 (P < 0.001), for patients and controls, respectively. The DAD scale showed good internal consistency (Cronbach alpha = 0.77) and correlation with the Mini-Mental State Examination (r = 0.44; P < 0.001). The AD group did better on basic ADL than on instrumental ADL (P < 0.001). As expected, controls did not exhibit significant deficits on the items evaluated. Conclusion: The Brazilian version of the DAD is an adequate and reliable tool for assessing functional ability in AD patients.
Resumo:
BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Objective: To investigate glomerular development and expression of insulin and insulin-like growth factor receptors in an experimental model of intrauterine growth restriction (IUGR). Material and Methods: We studied three groups of Sprague-Dawley fetuses: IUGR - restricted by ligation of the right uterine artery; C-IUGR - left horn controls, and EC - external controls (non-manipulated). Body and organs were weighed, and glomerular number and volume were analyzed. Expression of IR beta, IRS-1, IRS-2 and IGF-IR beta was analyzed in liver, intestine and kidneys by immunoblotting. Results: Organ/body weight ratios were similar. In IUGR, glomerular number and volume were increased compared to C-IUGR and EC (p < 0.001). In the IUGR liver, increases were found in IGF-IR beta compared to C-IUGR and EC; IR beta compared to EC, and IRS-2 compared to C-IUGR. However, decreases in IR beta were noted in IUGR compared to C-IUGR; IRS-1 compared to C-IUGR and EC, and IRS-2 compared to EC. In IUGR intestine, increases were detected in IR beta, IRS-1 and IGF-IR beta compared to C-IUGR and EC. In IUGR kidneys, increases were observed in IR beta and IGF-IR beta compared to C-IUGR and EC, and IRS-1 compared to EC. Decreased IRS-2 in the intestine and kidney were noticed in IUGR compared to C-IUGR and EC. Conclusion: IUGR fetuses had less glomeruli and alterations in insulin receptors, which may be associated with an increased risk of disease occurrence in adulthood. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
Background The mechanism underlying increased perception of food bolus passage in the absence of esophageal mechanical obstruction has not been completely elucidated. A correlation between the intensity of the symptom and the severity of esophageal dysfunction, either motility (manometry) or bolus transit (impedance) has not been clearly demonstrated. The aim of this study was to analyze the correlation between objective esophageal function assessment (with manometry and impedance) and perception of bolus passage in healthy volunteers (HV) with normal and pharmacologically-induced esophageal hypocontractility, and in patients with gastro-esophageal reflux disease (GERD) with and without ineffective esophageal motility (IEM). Methods Combined manometry-impedance was performed in 10 HV, 19 GERD patients without IEM and nine patients with IEM. Additionally, nine HV were studied after 50 mg sildenafil, which induced esophageal peristaltic failure. Perception of each 5 mL viscous swallow was evaluated using a 5-point scale. Manometry identified hypocontractility (contractions lower than 30 mmHg) and impedance identified incomplete bolus clearance. Key Results In HV and in GERD patients with and without IEM, there was no association between either manometry or impedance and perception on per swallow analysis (OR: 0.842 and OR: 2.017, respectively), as well as on per subject analysis (P = 0.44 and P = 0.16, respectively). Lack of correlation was also found in HV with esophageal hypocontractility induced by sildenafil. Conclusions & Inferences There is no agreement between objective measurements of esophageal function and subjective perception of bolus passage. These results suggest that increased bolus passage perception in patients without mechanical obstruction might be due to esophageal hypersensitivity.
Resumo:
The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.