887 resultados para Nondestructive Testing and Evaluation
Resumo:
The aim of this study was to assess the variation between neuropathologists in the diagnosis of common dementia syndromes when multiple published protocols are applied. Fourteen out of 18 Australian neuropathologists participated in diagnosing 20 cases (16 cases of dementia, 4 age-matched controls) using consensus diagnostic methods. Diagnostic criteria, clinical synopses and slides from multiple brain regions were sent to participants who were asked for case diagnoses. Diagnostic sensitivity, specificity, predictive value, accuracy and variability were determined using percentage agreement and kappa statistics. Using CERAD criteria, there was a high inter-rater agreement for cases with probable and definite Alzheimer's disease but low agreement for cases with possible Alzheimer's disease. Braak staging and the application of criteria for dementia with Lewy bodies also resulted in high inter-rater agreement. There was poor agreement for the diagnosis of frontotemporal dementia and for identifying small vessel disease. Participants rarely diagnosed more than one disease in any case. To improve efficiency when applying multiple diagnostic criteria, several simplifications were proposed and tested on 5 of the original 210 cases. Inter-rater reliability for the diagnosis of Alzheimer's disease and dementia with Lewy bodies significantly improved. Further development of simple and accurate methods to identify small vessel lesions and diagnose frontotemporal dementia is warranted.
Resumo:
Members of the Culex sitiens subgroup are important vectors of arboviruses, including Japanese encephalitis virus, Murray Valley encephalitis virus and Ross River virus. Of the eight described species, Cx. annulirostris Skuse, Cx. sitiens Wiedemann, and Cx. palpalis Taylor appear to be the most abundant and widespread throughout northern Australia and Papua New Guinea (PNG). Recent investigations using allozymes have shown this subgroup to contain cryptic species that possess overlapping adult morphology. We report the development of a polymerase chain reaction-restriction fragment-length polymorphism (PCR-RFLP) procedure that reliably separates these three species. This procedure utilizes the sequence variation in the ribosomal DNA ITS1 and demonstrates species-specific PCR-RFLP profiles from both colony and field collected material. Assessment of the consistency of this procedure was undertaken on mosquitoes sampled from a wide geographic area including Australia, PNG, and the Solomon Islands. Overlapping adult morphology was observed for Cx. annulirostris and Cx. palpalis in both northern Queensland and PNG and for all three species at one site in northwest Queensland.
Resumo:
The current level of demand by customers in the electronics industry requires the production of parts with an extremely high level of reliability and quality to ensure complete confidence on the end customer. Automatic Optical Inspection (AOI) machines have an important role in the monitoring and detection of errors during the manufacturing process for printed circuit boards. These machines present images of products with probable assembly mistakes to an operator and him decide whether the product has a real defect or if in turn this was an automated false detection. Operator training is an important aspect for obtaining a lower rate of evaluation failure by the operator and consequently a lower rate of actual defects that slip through to the following processes. The Gage R&R methodology for attributes is part of a Six Sigma strategy to examine the repeatability and reproducibility of an evaluation system, thus giving important feedback on the suitability of each operator in classifying defects. This methodology was already applied in several industry sectors and services at different processes, with excellent results in the evaluation of subjective parameters. An application for training operators of AOI machines was developed, in order to be able to check their fitness and improve future evaluation performance. This application will provide a better understanding of the specific training needs for each operator, and also to accompany the evolution of the training program for new components which in turn present additional new difficulties for the operator evaluation. The use of this application will contribute to reduce the number of defects misclassified by the operators that are passed on to the following steps in the productive process. This defect reduction will also contribute to the continuous improvement of the operator evaluation performance, which is seen as a quality management goal.
Resumo:
Ring hockey is a complex team sport with physical tecnical and tactical high demans (Manaças, 1988; Rodriguez, 1991). In teh absence of a battery of specific tests we proceed to the aplication of the 20 meters shuttle run test (Luc Leger, 1982) in youthfuk athletes of the juveniles.
Resumo:
Portugal has the largest LPG (Liquefied Petroleum Gas) share of primary energy demand in the EU (about 5%). Due to the increasing international cost of LPG in the last years and the high price sensitivity of the consumers the preference for substitute energy sources in new and existing consumers has been increasing. To select the kind of energy, some consumer estimate and compare the total costs while others follow agents (equipment sellers) recommendations. It takes time to build agents perception about the most advantageous source of energy, which is seen as an important resource that drives client resource accumulation and retention. Marketing strategies have to take into consideration some market dynamic effects derived from the accumulation and depletion of these resources. A simple system dynamics model was built, combined with Economic Value Added framework, to evaluate some pricing strategies under different scenarios of LPG international cost.
Resumo:
Portugal has the largest LPG (Liquefied Petroleum Gas) share of primary energy demand in the EU (about 5%). Due to the increasing international cost of LPG in the last years and the high price sensitivity of the consumers the preference for substitute energy sources in new and existing consumers has been increasing. To select the kind of energy, some consumer estimate and compare the total costs while others follow agents (equipment sellers) recommendations. It takes time to build agents perception about the most advantageous source of energy, which is seen as an important resource that drives client resource accumulation and retention. Marketing strategies have to take into consideration some market dynamic effects derived from the accumulation and depletion of these resources. A simple system dynamics model was built, combined with Economic Value Added framework, to evaluate some pricing strategies under different scenarios of LPG international cost.
Resumo:
The Developmental Dysplasia of the Hip (DDH), also know as Congenital Dislocation of the Hip, is common in infants and children and may persist into adulthood. The radiographic interpretation is highly conditioned by appropriate patient positioning and image quality criteria. The main goal of this study is to demonstrate the value of radiographic evaluation of DDH. Through the retrospective analysis of 65 radiographs of the hips, only 2 (3.1%) female patients with 1-2 years of age presented radiographic findings of DDH. The inappropriate field size and the improper placement and size of the gonadal shields, were the most common errors observed.
Resumo:
OBJECTIVE: To extend an existing computer programme for the evaluation and design of shift schedules (BASS 3) by integrating workload as well as economic aspects. METHODS: The redesigned prototype BASS 4 includes a new module with a suitable and easily applicable screening method (EBA) for the assessment of the intensity of physical, emotional and cognitive workload components and their temporal patterns. Specified criterion functions based on these ratings allow for an adjustment of shift and rest duration according to the intensity of physical and mental workload. Furthermore, with regard to interactive effects both workload and temporal conditions, e.g. time of day, are taken into account. In a second new module, important economic aspects and criteria have been implemented. Different ergonomic solutions for scheduling problems can now also be evaluated with regard to their economic costs. RESULTS: The new version of the computer programme (BASS 4) can now simultaneously take into account numerous ergonomic, legal, agreed and economic criteria for the design and evaluation of working hours. CONCLUSIONS: BASS 4 can now be used as an instrument for the design and the evaluation of working hours with regard to legal, ergonomic and economic aspects at the shop floor as well as in administrative (e.g. health and safety inspection) and research problems.
Resumo:
A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%.
Resumo:
Radio frequency (RF) energy harvesting is an emerging technology that will enable to drive the next generation of wireless sensor networks (WSNs) without the need of using batteries. In this paper, we present RF energy harvesting circuits specifically developed for GSM bands (900/1800) and a wearable dual-band antenna suitable for possible implementation within clothes for body worn applications. Besides, we address the development and experimental characterization of three different prototypes of a five-stage Dickson voltage multiplier (with match impedance circuit) responsible for harvesting the RF energy. Different printed circuit board (PCB) fabrication techniques to produce the prototypes result in different values of conversion efficiency. Therefore, we conclude that if the PCB fabrication is achieved by means of a rigorous control in the photo-positive method and chemical bath procedure applied to the PCB it allows for attaining better values for the conversion efficiency. All three prototypes (1, 2 and 3) can power supply the IRIS sensor node for RF received powers of -4 dBm, -6 dBm and -5 dBm, and conversion efficiencies of 20, 32 and 26%, respectively. © 2014 IEEE.
Resumo:
Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.
Resumo:
OBJECTIVE To analyze the clinical and laboratory characteristics of HIV-infected individuals upon admission to a reference health care center.METHODS This cross-sectional study was conducted between 1999 and 2010 on 527 individuals with confirmed serological diagnosis of HIV infection who were enrolled in an outpatient health care service in Santarém, PA, Northern Brazil. Data were collected from medical records and included the reason for HIV testing, clinical status, and count of peripheral CD4+ T lymphocytes upon enrollment. The data were divided into three groups, according to the patient’s year of admission – P1 (1999-2002), P2 (2003-2006), and P3 (2007-2010) – for comparative analysis of the variables of interest.RESULTS In the study group, 62.0% of the patients were assigned to the P3 group. The reason for undergoing HIV testing differed between genders. In the male population, most tests were conducted because of the presence of symptoms suggesting infection. Among women, tests were the result of knowledge of the partner’s seropositive status in groups P1 and P2. Higher proportion of women undergoing testing because of symptoms of HIV/AIDS infection abolished the difference between genders in the most recent period. A higher percentage of patients enrolling at a more advanced stage of the disease was observed in P3.CONCLUSIONS Despite the increased awareness of the number of HIV/AIDS cases, these patients have identified their serological status late and were admitted to health care units with active disease. The HIV/AIDS epidemic in Pará presents specificities in its progression that indicate the complex characteristics of the epidemic in the Northern region of Brazil and across the country.
Resumo:
A passive haemagglutination test (PHA) for human neurocysticercosis was standardized and evaluated for the detection of specific antibodies to Cysticercus cellulosae in cerebrospinal fluid (CSF). For the assay, formaldehyde-treated group O Rh-human red cells coated with the cysticerci crude total saline extract (TS) antigen were employed. A total of 115 CSF samples from patients with neurocysticercosis was analysed, of these 94 presented reactivity, corresponding to 81.7% sensitivity, in which confidence limit of 95% probability (CL95%) ranged from 74.5% to 88.9%. Eighty-nine CSF samples derived from individuals of control group presented as nonreactive in 94.4% (CL95% from 89.6% to 99.2%). The positive and negative predictive values were 1.4% and 99.9%, respectively, considering the mean rate of that this assay provide a rapid, highly reproducible, and moderately sensitive mean of detecting specific antibodies in CSF samples.
Resumo:
From each of a group of 217 adult males selected through enzyme-immunoassay or skin-test (Group A), six stool samples were examined by both the Lutz/Hoffman, Pons & Janer (Lutz/HPJ) and Kato/Katz methods. In addition, one oogram of the rectal mucosa was performed. By these methods, schistosomiasis was detected in 44.7%, 47.5% and 40.1% of the individuals respectively. To evaluate the methods in the assessment of cure, the last 40 patients from group A, treated with a single oral dose of oxamniquine at 15 mg/kg were followed up for six months (Group B). The criteria for parasitological cure included three stool examinations by Kato/Katz and Lutz/HPJ methods, one, three and six months post-treatment and a rectal biopsy between the fourth and sixth months post-treatment. The examinations were negative in 87.5%, 90% and 95% of the patients, respectively. The efficacy of oxamniquine was 82.5% when the three methods were considered together and there was no statistically significant difference between the sensitivity of the individual methods.
Resumo:
A Dot-ELISA using a measles virus (MV) antigen obtained by sodium deoxycholate treatment was standardized and evaluated for IgM and IgG antibody detection in measles patients and measles-vaccinated subjects. A total of 192 serum samples were studied, comprising 47 from patients with acute and convalescent measles, 55 from 9-month old children prior to measles vaccination and 41 from children of the same age after vaccination, and 49 from patients with unrelated diseases. The diagnostic performances of the IgG Dot-ELISA and IgG immuno fluorescence test (IFT) were found to be close, varying from 0.97 to 1.00 in sensitivity and the specificities were maximum (1.00). Nevertheless, the sensitivity of the IgM Dot-ELISA (0.85) was higher than that (0.63) of the IgM IFT, although both assays had comparably high (1.00) specificities. The IgM Dot-ELISA in particular proved to be more sensitive in relation to other assays studied by revealing antibodies in 80.0% (12/15) of vaccinated children on the 15th day after immunization. In contrast the IgM IFT, failed to detect antibodies in the same group of vaccinated children. The stability of the MV antigen was longer than that of the IFT antigen, and the reproducibility of the Dot-Elisa was satisfactory.