954 resultados para Non-invasive temperature estimation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Major depressive disorder (MDD) trials - investigating either non-pharmacological or pharmacological interventions - have shown mixed results. Many reasons explain this heterogeneity, but one that stands out is the trial design due to specific challenges in the field. We aimed therefore to review the methodology of non-invasive brain stimulation (NIBS) trials and provide a framework to improve clinical trial design. We performed a systematic review for randomized, controlled MDD trials whose intervention was transcranial magnetic stimulation (rTMS) or transcranial direct current stimulation (tDCS) in MEDLINE and other databases from April 2002 to April 2008. We created an unstructured checklist based on CONSORT guidelines to extract items such as power analysis, sham method, blinding assessment, allocation concealment, operational criteria used for MDD, definition of refractory depression and primary study hypotheses. Thirty-one studies were included. We found that the main methodological issues can be divided in to three groups: (1) issues related to phase II/small trials, (2) issues related to MDD trials and, (3) specific issues of NIBS studies. Taken together, they can threaten study validity and lead to inconclusive results. Feasible solutions include: estimating the sample size a priori; measuring the degree of refractoriness of the subjects; specifying the primary hypothesis and statistical tests; controlling predictor variables through stratification randomization methods or using strict eligibility criteria; adjusting the study design to the target population; using adaptive designs and exploring NIBS efficacy employing biological markers. In conclusion, our study summarizes the main methodological issues of NIBS trials and proposes a number of alternatives to manage them. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study aim. - We describe a new neuronavigation-guided technique to target the posterior-superior insula (PSI) using a cooled-double-cone coil for deep cortical stimulation. Introduction. - Despite the analgesic effects brought about by repetitive transcranial magnetic stimulation (TMS) to the primary motor and prefrontal cortices, a significant proportion of patients remain symptomatic. This encouraged the search for new targets that may provide stronger pain relief. There is growing evidence that the posterior insula is implicated in the integration of painful stimuli in different pain syndromes and in homeostatic thermal integration. Methods. - The primary motor cortex representation of the lower leg was used to calculate the motor threshold and thus, estimate the intensity of PSI stimulation. Results. - Seven healthy volunteers were stimulated at 10 Hz to the right PSI and showed subjective changes in cold perception. The technique was safe and well tolerated. Conclusions. - The right posterior-superior insula is worth being considered in future studies as a possible target for rTMS stimulation in chronic pain patients. (c) 2012 Elsevier Masson SAS. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In the literature, there are several experimental models that induce scoliosis in rats; however, they make use of drugs or invasive interventions to generate a scoliotic curve. Objectives: To design and apply a non-invasive immobilization model to induce scoliosis in rats. Methods: Four-week old male Wistar rats (85 +/- 3.3 g) were divided into two groups: control (CG) and scoliosis (SG). The animals in the SG were immobilized by two vests (scapular and pelvic) made from polyvinyl chloride (PVC) and externally attached to each other by a retainer that regulated the scoliosis angle for twelve weeks with left convexity. After immobilization, the abdominal, intercostal, paravertebral, and pectoral muscles were collected for chemical and metabolic analyses. Radiographic reports were performed every 30 days over a 16-week period. Results: The model was effective in the induction of scoliosis, even 30 days after immobilization, with a stable angle of 28 +/- 5 degrees. The chemical and metabolic analyses showed a decrease (p<0.05) in the glycogenic reserves and in the relationship between DNA and total protein reserves of all the muscles analyzed in the scoliosis group, being lower (p<0.05) in the convex side. The values for the Homeostatic Model Assessment of Insulin Resistance indicated a resistance condition to insulin (p<0.05) in the scoliosis group (0.66 +/- 0.03), when compared to the control group (0.81 +/- 0.02). Conclusions: The scoliosis curvature remained stable 30 days after immobilization. The chemical and metabolic analyses suggest changes in muscular homeostasis during the induced scoliosis process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate right ventricular function in patients with right ventricular volume overload in patients with (tetralogy of Fallot, and pulmonary atresia + VSD ) underwent corrective surgery; with echocardiography measure that can be easily applied; and to study the relationship between ProBNP and the contractile function of the right ventricle, dilated right atrium, and the consequences of pulmonary insufficiency . Methods: The study included 50 patients (50% males, mean age 30.64 ± 13.30 years) with prior cardiac surgical intervention of TDF (90%) or pulmonary atresia + VSD (10%). (49 pz) have performed a cardiac MRI and clinical evaluation, (47 pz) echocardiogram, (48 pz) ECG, (34 pz) a cardiopulmonary exercise testing, (29 pz) a dosage of ProBNP. Results: The S-wave velocity (p <0.0001), the TAPSE (p <0.0001) correlated significantly with RVEF estimated by cardiac MRI. The VO2 max was 27.93 ± 12.91 ml / kg / min, 15% of patients had VE/VCO2 The peak> 35. ProBNP correlated positively and significantly with the area of the right atrium (p = 0.0001), and negative and significant with VO2 max (p = 0.04). Those who have increased pulmonary insufficiency (PVR fraction> 30%) have a significantly increased RVED volume (p = 0.01), reduced VO2 max (p = 0.04), and lower ejection fraction of LV (p = 0.02) than the group of patients with PVR ≤ 30. Conclusion: The TAPSE and S-wave velocity are fundamental and may become the technique of choice for routine assessment of RV systolic function in adult patients with TOF. The monitoring of the Pro BNP is probably a choice, given the simplicity and their information that correlate with the test cardiopulmonary. In view of the ventricular-ventricular interaction, so measures to maintain or restore the functioning of the pulmonary valve could preserve biventricular function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lattice Quantum Chromodynamics (LQCD) is the preferred tool for obtaining non-perturbative results from QCD in the low-energy regime. It has by nowrnentered the era in which high precision calculations for a number of phenomenologically relevant observables at the physical point, with dynamical quark degrees of freedom and controlled systematics, become feasible. Despite these successes there are still quantities where control of systematic effects is insufficient. The subject of this thesis is the exploration of the potential of todays state-of-the-art simulation algorithms for non-perturbativelyrn$\mathcal{O}(a)$-improved Wilson fermions to produce reliable results in thernchiral regime and at the physical point both for zero and non-zero temperature. Important in this context is the control over the chiral extrapolation. Thisrnthesis is concerned with two particular topics, namely the computation of hadronic form factors at zero temperature, and the properties of the phaserntransition in the chiral limit of two-flavour QCD.rnrnThe electromagnetic iso-vector form factor of the pion provides a platform to study systematic effects and the chiral extrapolation for observables connected to the structure of mesons (and baryons). Mesonic form factors are computationally simpler than their baryonic counterparts but share most of the systematic effects. This thesis contains a comprehensive study of the form factor in the regime of low momentum transfer $q^2$, where the form factor is connected to the charge radius of the pion. A particular emphasis is on the region very close to $q^2=0$ which has not been explored so far, neither in experiment nor in LQCD. The results for the form factor close the gap between the smallest spacelike $q^2$-value available so far and $q^2=0$, and reach an unprecedented accuracy at full control over the main systematic effects. This enables the model-independent extraction of the pion charge radius. The results for the form factor and the charge radius are used to test chiral perturbation theory ($\chi$PT) and are thereby extrapolated to the physical point and the continuum. The final result in units of the hadronic radius $r_0$ is rn$$ \left\langle r_\pi^2 \right\rangle^{\rm phys}/r_0^2 = 1.87 \: \left(^{+12}_{-10}\right)\left(^{+\:4}_{-15}\right) \quad \textnormal{or} \quad \left\langle r_\pi^2 \right\rangle^{\rm phys} = 0.473 \: \left(^{+30}_{-26}\right)\left(^{+10}_{-38}\right)(10) \: \textnormal{fm} \;, $$rn which agrees well with the results from other measurements in LQCD and experiment. Note, that this is the first continuum extrapolated result for the charge radius from LQCD which has been extracted from measurements of the form factor in the region of small $q^2$.rnrnThe order of the phase transition in the chiral limit of two-flavour QCD and the associated transition temperature are the last unkown features of the phase diagram at zero chemical potential. The two possible scenarios are a second order transition in the $O(4)$-universality class or a first order transition. Since direct simulations in the chiral limit are not possible the transition can only be investigated by simulating at non-zero quark mass with a subsequent chiral extrapolation, guided by the universal scaling in the vicinity of the critical point. The thesis presents the setup and first results from a study on this topic. The study provides the ideal platform to test the potential and limits of todays simulation algorithms at finite temperature. The results from a first scan at a constant zero-temperature pion mass of about 290~MeV are promising, and it appears that simulations down to physical quark masses are feasible. Of particular relevance for the order of the chiral transition is the strength of the anomalous breaking of the $U_A(1)$ symmetry at the transition point. It can be studied by looking at the degeneracies of the correlation functions in scalar and pseudoscalar channels. For the temperature scan reported in this thesis the breaking is still pronounced in the transition region and the symmetry becomes effectively restored only above $1.16\:T_C$. The thesis also provides an extensive outline of research perspectives and includes a generalisation of the standard multi-histogram method to explicitly $\beta$-dependent fermion actions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La tesi descrive la stimolazione magnetica transcranica, un metodo di indagine non invasivo. Nel primo capitolo ci si è soffermati sull’ anatomia e funzionalità del sistema nervoso sia centrale che periferico e sulle caratteristiche principali delle cellule neuronali. Nel secondo capitolo vengono descritte inizialmente le basi fisico-tecnologiche della strumentazione stessa, dando particolare attenzione ai circuiti che costituiscono gli stimolatori magnetici ed alle tipologie di bobine più utilizzate. Successivamente si sono definiti i principali protocolli di stimolazione evidenziandone le caratteristiche principali come, ampiezza, durata e frequenza dell’impulso. Nel terzo capitolo vengono descritti i possibili impieghi della stimolazione in ambito sperimentale e terapeutico. Nel quarto ed ultimo capitolo si evidenziano i limiti, della strumentazione e dell’analisi che la stessa permette, andando a definire i parametri di sicurezza, i possibili effetti indesiderati, il costo dell’apparecchiatura e l’uso combinato con altre tecniche specifiche

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. Methods We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. Results Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. Conclusion StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Acute hemodynamic instability increases morbidity and mortality. We investigated whether early non-invasive cardiac output monitoring enhances hemodynamic stabilization and improves outcome. Methods A multicenter, randomized controlled trial was conducted in three European university hospital intensive care units in 2006 and 2007. A total of 388 hemodynamically unstable patients identified during their first six hours in the intensive care unit (ICU) were randomized to receive either non-invasive cardiac output monitoring for 24 hrs (minimally invasive cardiac output/MICO group; n = 201) or usual care (control group; n = 187). The main outcome measure was the proportion of patients achieving hemodynamic stability within six hours of starting the study. Results The number of hemodynamic instability criteria at baseline (MICO group mean 2.0 (SD 1.0), control group 1.8 (1.0); P = .06) and severity of illness (SAPS II score; MICO group 48 (18), control group 48 (15); P = .86)) were similar. At 6 hrs, 45 patients (22%) in the MICO group and 52 patients (28%) in the control group were hemodynamically stable (mean difference 5%; 95% confidence interval of the difference -3 to 14%; P = .24). Hemodynamic support with fluids and vasoactive drugs, and pulmonary artery catheter use (MICO group: 19%, control group: 26%; P = .11) were similar in the two groups. The median length of ICU stay was 2.0 (interquartile range 1.2 to 4.6) days in the MICO group and 2.5 (1.1 to 5.0) days in the control group (P = .38). The hospital mortality was 26% in the MICO group and 21% in the control group (P = .34). Conclusions Minimally-invasive cardiac output monitoring added to usual care does not facilitate early hemodynamic stabilization in the ICU, nor does it alter the hemodynamic support or outcome. Our results emphasize the need to evaluate technologies used to measure stroke volume and cardiac output--especially their impact on the process of care--before any large-scale outcome studies are attempted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The real utilisation scenario of non-invasive ventilation (NIV) in Swiss ICUs has never been reported. Using a survey methodology, we developed a questionnaire sent to the directors of the 79 adult ICUs to identify the perceived pattern of NIV utilisation. We obtained a response rate of 62%. The overall utilisation rate for NIV was 26% of all mechanical ventilations, but we found significant differences in the utilisation rates among different linguistic areas, ranging from 20% in the German part to 48% in the French part (p <0.01). NIV was mainly indicated for the acute exacerbations of COPD (AeCOPD), acute cardiogenic pulmonary edema (ACPE) and acute respiratory failure (ARF) in selected do-not-intubate patients. In ACPE, CPAP was much less used than bi-level ventilation and was still applied in AeCOPD. The first line interface was a facial mask (81%) and the preferred type of ventilator was an ICU machine with an NIV module (69%). The perceived use of NIV is generally high in Switzerland, but regional variations are remarkable. The indications of NIV use are in accordance with international guidelines. A high percentage of units consider selected do-not-intubate conditions as an important additional indication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Blood oxygenation level-dependent (BOLD) MRI was shown to allow non-invasive observation of renal oxygenation in humans. However, clinical applications of this type of functional MRI of the kidney are still limited, most likely because of difficulties in obtaining reproducible and reliable information. The aim of this study was to evaluate the reproducibility and robustness of a BOLD method applied to the kidneys and to identify systematic physiological changes potentially influencing the renal oxygenation of healthy volunteers. To measure the BOLD effect, a modified multi-echo data image combination (MEDIC) sequence was used to acquire 12 T2*-weighted images within a single breath-hold. Three identical measurements were performed on three axial and three coronal slices of right and left kidneys in 18 volunteers. The mean R2* (1/T2*) values determined in medulla and cortex showed no significant differences over three repetitions and low intra-subject coefficients of variation (CV) (3 and 4% in medulla and cortex, respectively). The average R2* values were higher in the medulla (16.15 +/- 0.11) than in the cortex (11.69 +/- 0.18) (P < 0.001). Only a minor influence of slice orientation was observed. Mean R2* values were slightly higher (3%) in the left than in the right kidney (P < 0.001). Differences between volunteers were identified (P < 0.001). Part of these differences was attributable to age-dependent R2* values, since these values increased with age when medulla (P < 0.001, r = 0.67) or cortex (P < 0.020, r = 0.42) were considered. Thus, BOLD measurements in the kidney are highly reproducible and robust. The results allow one to identify the known cortico-medullary gradient of oxygenation evidenced by the gradient of R2* values and suggest that medulla is more hypoxic in older than younger individuals. BOLD-MRI is therefore a useful tool to study sequentially and non-invasively regional oxygenation of human kidneys.