994 resultados para Naval Air Station Kingsville (Tex.). Training Air Wing Two.


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

includes index.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present here observations on diurnal and seasonal variation of mixing ratio and delta C-13 of air CO2, from an urban station-Bangalore (BLR), India, monitored between October 2008 and December 2011. On a diurnal scale, higher mixing ratio with depleted delta C-13 of air CO2 was found for the samples collected during early morning compared to the samples collected during late afternoon. On a seasonal scale, mixing ratio was found to be higher for dry summer months (April-May) and lower for southwest monsoon months (June-July). The maximum enrichment in delta C-13 of air CO2 (-8.04 +/- 0.02aEuro degrees) was seen in October, then delta C-13 started depleting and maximum depletion (-9.31 +/- 0.07aEuro degrees) was observed during dry summer months. Immediately after that an increasing trend in delta C-13 was monitored coincidental with the advancement of southwest monsoon months and maximum enrichment was seen again in October. Although a similar pattern in seasonal variation was observed for the three consecutive years, the dry summer months of 2011 captured distinctly lower amplitude in both the mixing ratio and delta C-13 of air CO2 compared to the dry summer months of 2009 and 2010. This was explained with reduced biomass burning and increased productivity associated with prominent La Nina condition. While compared with the observations from the nearest coastal and open ocean stations-Cabo de Rama (CRI) and Seychelles (SEY), BLR being located within an urban region captured higher amplitude of seasonal variation. The average delta C-13 value of the end member source CO2 was identified based on both diurnal and seasonal scale variation. The delta C-13 value of source CO2 (-24.9 +/- 3aEuro degrees) determined based on diurnal variation was found to differ drastically from the source value (-14.6 +/- 0.7aEuro degrees) identified based on seasonal scale variation. The source CO2 identified based on diurnal variation incorporated both early morning and late afternoon sample; whereas, the source CO2 identified based on seasonal variation included only afternoon samples. Thus, it is evident from the study that sampling timing is one of the important factors while characterizing the composition of end member source CO2 for a particular station. The difference in delta C-13 value of source CO2 obtained based on both diurnal and seasonal variation might be due to possible contribution from cement industry along with fossil fuel / biomass burning as predominant sources for the station along with differential meteorological conditions prevailed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The strong spatial and temporal variability of traffic-related air pollution detected at roadside locations in a number of European cities has raised the question of how representative the site and time period of air quality measurements actually can be. To address this question, a 7-month sampling campaign was carried out on a major road axis (Avenue Leclerc) leading to a very busy intersection (Place Basch) in central Paris, covering the surroundings of a permanent air quality monitoring station. This station has recorded the highest CO and NOx concentrations during recent years in the region of Paris. Diffusive BTX samplers as well as a mobile monitoring unit equipped with real-time CO, NOx and O3 analysers and meteorological instruments were used to reveal the small-scale pollution gradients and their temporal trends near the permanent monitoring station. The diffusive measurements provided 7-day averages of benzene, toluene, xylene and other hydrocarbons at different heights above the ground and distances from the kerb covering summer and winter periods. Relevant traffic and meteorological data were also obtained on an hourly basis. Furthermore, three semiempirical dispersion models (STREET-SRI, OSPM and AEOLIUS) were tested for an asymmetric canyon location in Av. Leclerc. The analysis of this comprehensive data set has helped to assess the representativeness of air quality monitoring information.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present an optimal methodology for synchronized scheduling of production assembly with air transportation to achieve accurate delivery with minimized cost in consumer electronics supply chain (CESC). This problem was motivated by a major PC manufacturer in consumer electronics industry, where it is required to schedule the delivery requirements to meet the customer needs in different parts of South East Asia. The overall problem is decomposed into two sub-problems which consist of an air transportation allocation problem and an assembly scheduling problem. The air transportation allocation problem is formulated as a Linear Programming Problem with earliness tardiness penalties for job orders. For the assembly scheduling problem, it is basically required to sequence the job orders on the assembly stations to minimize their waiting times before they are shipped by flights to their destinations. Hence the second sub-problem is modelled as a scheduling problem with earliness penalties. The earliness penalties are assumed to be independent of the job orders.