571 resultados para Multiplex


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We extend the concept of eigenvector centrality to multiplex networks, and introduce several alternative parameters that quantify the importance of nodes in a multi-layered networked system, including the definition of vectorial-type centralities. In addition, we rigorously show that, under reasonable conditions, such centrality measures exist and are unique. Computer experiments and simulations demonstrate that the proposed measures provide substantially different results when applied to the same multiplex structure, and highlight the non-trivial relationships between the different measures of centrality introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este proyecto versa sobre un modelo de evaluación de calidad de imagen aplicado a la optimización del ancho de banda del multiplex de televisión, mediante la realización de ensayos con distintas configuraciones de cabecera. Dicho modelo se basa en las medidas PQR y DMOS de Tektronix, destinadas a medir la percepción de las diferencias entre una secuencia antes y después de sufrir un procesado digital. Dado que actualmente, el modo de trabajo de una cabecera de televisión digital, es la multiplexación estadística (consistente en la codificación de diferentes servicios de vídeo con anchos de banda variables en función de la complejidad de las señales), las medidas estarán enfocadas a sacar conclusiones acerca de la cantidad de canales, complejidad de contenidos, y organización de los mismos en el ancho de banda disponible para emitir, manteniendo niveles de calidad Broadcast. Las medidas serán aplicadas en el proyecto para comparar el rendimiento de dos modelos de cabecera. En primer lugar serán configuradas en régimen binario constante, comparando el rendimiento de los codificadores en el área de trabajo habitual. Posteriormente se configuraran en régimen binario variable probando múltiples configuraciones, con el objetivo dar con el modelo y configuración óptima para su posterior implementación. ABSTRACT. This project concerns a picture quality assessment model applied to television multiplex bandwidth optimization by conducting test with different headend settings. This model is based on the PQR and DMOS Tektronix measures, designed to measure the differences between a sequence before and after a digital processing. Given that nowadays the working way of television headend is by statistical multiplexing (based on coding the different video services with variable bitrate depending on the complexity of the signals) measures will be focused to reach conclusions about the number of channels, complexity of content, and the way to organize them through the available bandwidth, keeping broadcast quality ratios. The measures will be applied comparing the performance of two headend models. First of all encoders will be set on constant bitrate, comparing the performance through the working bandwidth. Later on, both models will be set on variable bitrate testing multiple configurations, in order to find the optimal model/configuration for later implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a multiplex nucleic acid assay that identifies and determines the abundance of four different pathogenic retroviruses (HIV-1, HIV-2, and human T-lymphotrophic virus types I and II). Retroviral DNA sequences are amplified in a single, sealed tube by simultaneous PCR assays, and the resulting amplicons are detected in real time by the hybridization of four differently colored, amplicon-specific molecular beacons. The color of the fluorescence generated in the course of amplification identifies which retroviruses are present, and the number of thermal cycles required for the intensity of each color to rise significantly above background provides an accurate measure of the number of copies of each retroviral sequence that were present originally in the sample. Fewer than 10 retroviral genomes can be detected. Moreover, 10 copies of a rare retrovirus can be detected in the presence of 100,000 copies of an abundant retrovirus. Ninety-six samples can be analyzed in 3 hr on a single plate, and the use of a closed-tube format eliminates crossover contamination. Utilizing previously well characterized clinical samples, we demonstrate that each of the pathogenic retroviruses can be identified correctly and no false positives occur. This assay enables the rapid and reliable screening of donated blood and transplantable tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association of a particular mitochondrial DNA (mtDNA) mutation with different clinical phenotypes is a well-known feature of mitochondrial diseases. A simple genotype–phenotype correlation has not been found between mutation load and disease expression. Tissue and intercellular mosaicism as well as mtDNA copy number are thought to be responsible for the different clinical phenotypes. As disease expression of mitochondrial tRNA mutations is mostly in postmitotic tissues, studies to elucidate disease mechanisms need to be performed on patient material. Heteroplasmy quantitation and copy number estimation using small patient biopsy samples has not been reported before, mainly due to technical restrictions. In order to resolve this problem, we have developed a robust assay that utilizes Molecular Beacons to accurately quantify heteroplasmy levels and determine mtDNA copy number in small samples carrying the A8344G tRNALys mutation. It provides the methodological basis to investigate the role of heteroplasmy and mtDNA copy number in determining the clinical phenotypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To facilitate large-scale genotype analysis, an efficient PCR-based multiplex approach has been developed. For simultaneously amplifying the target sequences at a large number of genetic loci, locus-specific primers containing 5' universal tails are used. Attaching the universal tails to the target sequences in the initial PCR steps allows replacement of all specific primers with a pair of primers identical to the universal tails and converts the multiplex amplification into "uniplex." Simultaneous amplification of 26 genetic loci with this approach is described. The multiplex amplification can be coupled with genotype determination. By incorporating a single-base mismatch between a primer and the template into the target sequences, a polymorphic site can be converted into a desirable restriction fragment length polymorphism when it is necessary. In this way, the allelic PCR products for the polymorphic loci can be discriminated by gel electrophoresis after restriction enzyme digestion. In this study, 32 loci were typed in such a multiplex way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used a multiplex selection approach to construct a library of DNA-protein interaction sites recognized by many of the DNA-binding proteins present in a cell type. An estimated minimum of two-thirds of the binding sites present in a library prepared from activated Jurkat T cells represent authentic transcription factor binding sites. We used the library for isolation of "optimal" binding site probes that facilitated cloning of a factor and to identify binding activities induced within 2 hr of activation of Jurkat cells. Since a large fraction of the oligonucleotides obtained appear to represent "optimal" binding sites for sequence-specific DNA-binding proteins, it is feasible to construct a catalog of consensus binding sites for DNA-binding proteins in a given cell type. Qualitative and quantitative comparisons of the catalogs of binding site sequences from various cell types could provide valuable insights into the process of differentiation acting at the level of transcriptional control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automated oligonucleotide synthesizer has been developed that can simultaneously and rapidly synthesize up to 96 different oligonucleotides in a 96-well microtiter format using phosphoramidite synthesis chemistry. A modified 96-well plate is positioned under reagent valve banks, and appropriate reagents are delivered into individual wells containing the growing oligonucleotide chain, which is bound to a solid support. Each well has a filter bottom that enables the removal of spent reagents while retaining the solid support matrix. A seal design is employed to control synthesis environment and the entire instrument is automated via computer control. Synthesis cycle times for 96 couplings are < 11 min, allowing a plate of 96 20-mers to be synthesized in < 5 hr. Oligonucleotide synthesis quality is comparable to commercial machines, with average coupling efficiencies routinely > 98% across the entire 96-well plate. No significant well-to-well variations in synthesis quality have been observed in > 6000 oligonucleotides synthesized to date. The reduced reagent usage and increased capacity allow the overall synthesis cost to drop by at least a factor of 10. With the development of this instrument, it is now practical and cost-effective to synthesize thousands to tens of thousands of oligonucleotides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resistance to antibiotics used against Neisseria gonorrhoeae infections is a major public health concern. Antimicrobial resistance (AMR) testing relies on time-consuming culture-based methods. Development of rapid molecular tests for detecting AMR determinants could provide valuable tools for surveillance, epidemiological studies and to inform individual case management. We developed a fast (<1.5 hrs) SYBR-green based real-time PCR method with high resolution melting (HRM) analysis. One triplex and three duplex reactions included two sequences for N. gonorrhoeae identification and seven determinants of resistance to extended-spectrum cephalosporins (ESCs), azithromycin, ciprofloxacin, and spectinomycin. The method was validated by testing 39 previously fully-characterized N. gonorrhoeae strains, 19 commensal Neisseria spp., and an additional panel of 193 gonococcal isolates. Results were compared with culture-based AMR determination. The assay correctly identified N. gonorrhoeae and the presence or absence of the seven AMR determinants. There was some cross-reactivity with non-gonococcal Neisseria species and the detection limit was 10(3)-10(4) gDNA copies/reaction. Overall, the platform accurately detected resistance to ciprofloxacin (sensitivity and specificity, 100%), ceftriaxone (sensitivity 100%, specificity 90%), cefixime (sensitivity 92%, specificity 94%), azithromycin and spectinomycin (both sensitivity and specificity, 100%). In conclusion, our methodology accurately detects mutations generating resistance to antibiotics used to treat gonorrhea. Low assay sensitivity prevents direct diagnostic testing of clinical specimens but this method can be used to screen collections of gonococcal isolates for AMR more quickly than with current culture-based AMR testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report genetic characterization of isochromosome 18p using a combination of cytogenetic and molecular genetic methods, including multiplex fluorescent PCR. The patient was referred for chorionic villus sampling (CVS) due to advanced maternal age and maternal anxiety. The placental karyotype was 47,XX,+mar, with the marker having the appearance of a small supernumerary isochromosome. Because differentiating between isochromosomes and other structural rearrangements is normally very difficult, a variety of genetic tests including fluorescence in situ hybridization (FISH), PCR, and multiplex fluorescent PCR were undertaken to determine chromosomal origin and copy number and, thus, allow accurate diagnosis of the corresponding syndrome. FISH determined that the marker chromosome contained chromosome 18 material. PCR of a variety of short tandem repeats (STRs) confirmed that there was at least one extra copy of the maternal 18p material. However, neither FISH nor PCR could accurately determine copy number. Multiplex fluorescent PCR (MF-PCR) of STRs simultaneously determined that: (1) the marker included 18p material; (2) the marker was maternal in origin; (3) allele copy number indicated tetrasomy; and (4) contamination of the sample could be ruled out. Results were also rapid with accurate diagnosis of the syndrome tetrasomy 18p possible within 5 hours.