978 resultados para Multi-pulse converters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous demand for highly efficient wireless transmitter systems has triggered an increased interest in switching mode techniques to handle the required power amplification. The RF carrier amplitude-burst transmitter, i.e. a wireless transmitter chain where a phase-modulated carrier is modulated in amplitude in an on-off mode, according to some prescribed envelope-to-time conversion, such as pulse-width or sigma-delta modulation, constitutes a promising architecture capable of efficiently transmitting signals of highly demanding complex modulation schemes. However, the tested practical implementations present results that are way behind the theoretically advanced promises (perfect linearity and efficiency). My original contribution to knowledge presented in this thesis is the first thorough study and model of the power efficiency and linearity characteristics that can be actually achieved with this architecture. The analysis starts with a brief revision of the theoretical idealized behavior of these switched-mode amplifier systems, followed by the study of the many sources of impairments that appear when the real system is implemented. In particular, a special attention is paid to the dynamic load modulation caused by the often ignored interaction between the narrowband signal reconstruction filter and the usual single-ended switched-mode power amplifier, which, among many other performance impairments, forces a two transistor implementation. The performance of this architecture is clearly explained based on the presented theory, which is supported by simulations and corresponding measured results of a fully working implementation. The drawn conclusions allow the development of a set of design rules for future improvements, one of which is proposed and verified in this thesis. It suggests a significant modification to this traditional architecture, where now the phase modulated carrier is always on – and thus allowing a single transistor implementation – and the amplitude is impressed into the carrier phase according to a bi-phase code.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The laser produced plasma from the multi-component target YBa2CU3O7 was analyzed using Michelson interferometry and time resolved emission spectroscopy. The interaction of 10 ns pulses of 1.06 mum radiation from a Q-switched Nd:YAG laser at laser power densities ranging from 0.55 GW cm-2 to 1.5 GW cm-2 has been studied. Time resolved spectral measurements of the plasma evolution show distinct features at different points in its temporal history. For a time duration of less than 55 ns after the laser pulse (for a typical laser power density of 0.8 GW cm-2, the emission spectrum is dominated by black-body radiation. During cooling after 55 ns the spectral emission consists mainly of neutral and ionic species. Line averaged electron densities were deduced from interferometric line intensity measurements at various laser power densities. Plasma electron densities are of the order of 1017 cm-3 and the plasma temperature at the core region is about 1 eV. The measurement of plasma emission line intensities of various ions inside the plasma gave evidence of multiphoton ionization of the elements constituting the target at low laser power densities. At higher laser power densities the ionization mechanism is collision dominated. For elements such as nitrogen present outside the target, ionization is due to collisions only.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Metal pollution in rivers is in great concern with human activities in the fluvial watershed. This thesis aims to investigate the potential use of chl-a fluorescence parameters as biomarkers of metal toxicity, and to find cause-effect relationships between metal exposures, other environmental factor (i.e. light), and functional and structural biofilm responses. This thesis demonstrates that the use of chl-a fluorescence parameters allows detect early effects on biofilms caused by zinc toxicity, both in the laboratory as in polluted rivers. In microcosm experiments, the use of chl-a fluorescence parameters allows evaluates structural changes on photosynthetic apparatus and in algal groups’ composition of biofilms long-term exposed to zinc. In order to evaluate the effects of chronic metal pollution in rivers, it is recommended the use of biofilm translocation experiments and the use of a multi-biomarker approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditional chemometrics techniques are augmented with algorithms tailored specifically for the de-noising and analysis of femtosecond duration pulse datasets. The new algorithms provide additional insights on sample responses to broadband excitation and multi-moded propagation phenomena.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine (CoPc), modified multi-walled carbon nanotube (MWCNT), and paraffin composite electrode for the quantitative determination of epinephrine (EP) in human urine samples. The electrochemical profile of the proposed composite electrode was analyzed by differential pulse voltammetry (DPV) that showed a shift of the oxidation peak potential of EP at 175 mV to less positive value, compared with a paraffin/graphite composite electrode without CoPc. DPV experiments in PBS at pH 6.0 were performed to determine EP without any previous step of extraction, clean-up, and derivatization, in the range from 1.33 to 5.50 mu mol L(-1), with a detection limit of 15.6 nmol L(-1) (2.86) of EP in electrolyte prepared with purified water. The lifetime of the proposed sensors was at least over 1000 determinations with 1.7 and 3.1 repeatability and reproducibility relative standard deviations, respectively. Human urine samples without any purification step were successfully analyzed under the standard addition method using paraffin/MWCNT/CoPc composite electrode. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 3S (Shrinking-Search-Space) multi-thresholding method which have been used for segmentation of medical images according to their intensities, now have been implemented and compared with FCM method in terms of segmentation quality and segmentation time as a benchmark in thresholding. The results show that 3S method produced almost the same segmentation quality or in some occasions better quality than FCM, and the computation time of 3S method is much lower than FCM. This is another superiority of this method with respect to others. Also, the performance of C-means has been compared with two other methods. This comparison shows that, C-means is not a reliable clustering algorithm and it needs several run to give us a reliable result.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiple sample DNA amplification was done by using a novel rotary-linear motion polymerase chain reaction (PCR) device. A simple compact disc was used to create the stationary sample chambers which are individually temperature controlled. The PCR was performed by shuttling the samples to different temperature zones by using a combined rotary-linear movement of the disc. The device was successfully used to amplify up to 12 samples in less than 30 min with a sample volume of 5 μl. A simple spring loaded heater mechanism was introduced to enable good thermal contact between the samples and the heaters. Each of the heater temperatures are controlled by using a simple proportional–integral–derivative pulse width modulation control system. The results show a good improvement in the amplification rate and duration of the samples. The reagent volume used was reduced to nearly 25% of that used in conventional method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB (R)/SINIULINK (R) models to structural VHDL-AMS descriptions. The tool developed, named (MSSV)-S-2, reads a SIMULINK (R) model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the SystemVision (TM). To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB (R)/SIMULINK (R). The VHDL-AMS code generated automatically by (MSSV)-S-2, (MATLAB (R)/SIMULINK (R) to SystemVision (TM)), was then simulated in the SystemVision (TM). The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an improved analysis of a novel Programmable Power-factor-corrected-Based Hybrid Multipulse Power Rectifier (PFC-HMPR) for utility interface of power electronic converters. The proposed hybrid multipulse rectifier is composed of an ordinary three-phase six-pulse diode-bridge rectifier (Graetz bridge) with a parallel connection of single-phase switched converters in each three-phase rectifier leg. In this paper, the authors present a complete discussion about the controlled rectifiers' power contribution and also a complete analysis concerning the total harmonic distortion of current that can be achieved when the proposed converter operates as a conventional 12-pulse rectifier. The mathematical analysis presented in this paper corroborate, with detailed equations, the experimental results of two 6-kW prototypes implemented in a laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a new high power factor three-phase rectifier based on a Y-connected differential autotransformer with reduced kVA and 18-pulse input current followed by three DC-DC boost converters. The topology provides a regulated output voltage and natural three-phase input power factor correction. The lowest input current harmonic components are the 17th and the 19th. Three boost converters, with constant input currents and regulated parallel connected output voltages are used to process 4kW each one. Analytical results from Fourier analyses of winding currents and the vector diagram of winding voltages are presented. Simulation results to verify the proposed concept and experimental results are shown in the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB®/SIMULINK® models to structural VHDL-AMS descriptions. The tool developed, named MS 2SV, reads a SIMULINK® model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the System Vision™. To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB®/ SIMULINK®. The VHDL-AMS code generated automatically by MS 2SV, (MATLAB®/SIMULINK® to System Vision™), was then simulated in the System Vision™. The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new family of direct current (DC) to DC converters based on a zero current switching pulse width modulated (ZCS-PWM) soft commutation cell is presented. This ZCS-PWM cell is consists of two transistors, two diodes, two inductors and one capacitor; and provides zero voltage turn-on to the diodes, a zero-current turn-on and a zero-current zero-voltage turn-off to the transistors. In addition, a new commutation cell in a new ZCS-PWM boost rectifier is developed, obtaining a structure with power factor near the unity, high efficiency at wide load range and low total harmonic distortion in the input current.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO4. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm(-2)), 2 mu s delay time and 6 mu s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant. (C) 2011 Elsevier B. V. All rights reserved.