979 resultados para Mercury poisoning


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mercury ion (Hg2+) is able to specifically bind to the thymine-thymine (T-T) base pair in a DNA duplex, thus providing a rationale for DNA-based selective detection of Hg2+ with various means. In this work, we for the first time utilize the Hg2+-mediated T-T base pair to modulate the proper folding of G-quadruplex DNAs and inhibit the DNAzyme activity, thereby pioneering a facile approach to sense Hg2+ with colorimetry. Two bimolecular DNA G-quadruplexes containing many T residues are adopted here, which function well in low- and high-salt conditions, respectively. These G-quadruplex DNAs are able to bind hemin to form the peroxidase-like DNAzymes in the folded state. Upon addition of Hg2+, the proper folding of G-quadruplex DNAs is inhibited due to the formation of T-Hg2+-T complex. Ibis is reflected by the notable change of the Soret band of hemin when investigated by using UV-vis absorption spectroscopy. As a result of Hg2+ inhibition, a sharp decrease in the catalytic activity toward the H2O2-mediated oxidation of 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid)diammonium salt (ABTS) is observed, accompanied by a change in solution color. Through this approach, aqueous Hg2+ can be detected at 50 nM (10 ppb) with colorimetry in a facile way, with high selectivity against other metal ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed for the determination of micro mercury in the soil, plants and the traditional Chinese medicine using flow injection quartz tube-atomic absorption spectrometry. The effect of the factors such as acidity,. the carrier solution, the flow rate of reductive solution and argon gas, etc. on the determination was studied. When vanadic oxide, nitric acid and sulfuric acid were used to decompose the sample reliable result could be obtained. The characteristic mass of the method is 59 pg, the detection limit is 0.028 mug/L, RSD is < 3.9% and the recovery is in the range of 94% &SIM; 102%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for simultaneous spectrophotometric determination of Zn, Cd and Hg using 2-(5-Br-2-pyridylazo)-5-diethylaminophenol as the color developing reagent was proposed. The absorption spectra of these three complexes have similar features with severe overlap in visible spectral range. For resolving these spectra, hybrid linear analysis was used, and the pure spectrum of each component was obtained from the calibration mixtures by least squares method. The effects of reaction condition, selection of wavelengths, determination of pure spectrum and additivity of absorbances etc. on the determination were discussed. The proposed method offers the advantages of simple, rapid, and accuracy. It has been successfully applied to the simultaneous determination of Zn, Cd and Hg in synthetic sample. A comparison was also made with the partial least squares method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed for the determination of total mercury in biological samples. The effects of aqueous ammonia, ethylenediamine and triethanolamine on Hg signal intensity by inductively coupled plasma mass spectrometry has been evaluated and the possible mechanisms discussed. It has been proved that the signal intensity of Hg significantly increases with adding, in the presence of small amounts of aqueous ammonia, ethylenediamine or triethanolamine. The normalized intensity (the signal intensity ratio with amine and without amine) of Hg increases as the concentration of aqueous ammonia, ethylenediamine or triethanolamine increases, but the degree of enhancement of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The normalized intensity of Hg with aqueous ammonia, ethylenediamine and triethanolamine decreases as the nebulizer flow rate increases, but decreasing degree of aqueous ammonia was smaller than that of ethylenediamine and triethanolamine. The higher the RF powers the higher the normalized intensity of Hg at the same nebulizer flow rate. The addition of aqueous ammonia, ethylenediamine and triethanolamine into analytical solutions significantly improved the transport efficiency of Hg. The detection limit of Hg is improved about ten times by the addition of ethylenediamine or triethanolamine under the optimum experimental parameters. The method has been used to determine mercury in biological standard reference materials (SRM). The analytical results are very close to the certified values and the determined values for similar samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper summarizes some of the research and evaluation studies about mercury analysis in the environment during the past years in China. The main contents is as follows: 1) Determination of total mercury and speciation of mercury in air; 2) Storage and handling of water samples; 3) pre-treatment of solid samples; 4) Determination of total mercury and speciation of mercury in water and solid samples; 5) Certified reference materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy transfer phenomena have been observed by activating the oxyapatite host-lattice Ca2Gd8(SiO4)6O2 with Eu3+, Tb3+, Dy3+, Sm3+. This is based on the energy migration in the Gd3+ sublattice and trapping by the activators. The trapping efficiency for G

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel type of electrochemical detector based on a polyaniline-dispersed mercury-coated glassy carbon chemically modified electrode was investigated for the detection of monochloramine and dichloramine. A polyaniline dispersed-mercury modified electrode, which was prepared by coating polyaniline on a thin mercury film electrode using fast-sweep voltammetry, was developed. The selectivity could be altered using various counter ions incorporated into the polymer. The results indicated that the use of a conducting polymer-based electrochemical sensor for the selective determination of chloramine is a feasible approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the toxicity of heavy metals on the early development of Meretrix meretrix, the effects of mercury (Hg), cadmium (Cd) and lead (Pb) on embryogenesis, survival, growth and metamorphosis of larvae were investigated. The EC50 for embryogenesis was 5.4 mu g l(-1) for Hg, 1014 mu g l(-1) for Cd and 297 mu g l(-1) for Pb, respectively. The 96 h LC50 for D-shaped larvae was 14.0 mu g l(-1) for Hg, 68 mu g l(-1) for Cd and 353 mu g l(-1) for Pb, respectively. Growth was significantly retarded at 18.5 mu g l(-1) (0.1 mu M) for Hg, 104 mu g l(-1) (1 mu M) for Cd and 197 mu g l(-1) (1 mu M) for Pb, respectively. The EC50 for metamorphosis, similar to 48 h LC50, was higher than 96 h LC50. Our results indicate that the early development of M. meretrix is highly sensitive to heavy metals and can be used as a test organism for ecotoxicology bioassays in temperate and subtropical regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shellfish samples were collected from seven inter-tidal and two sub-tidal sites between 23 May and 8 June 1999 in Vancouver Harbour and were analysed for paralytic shellfish poisoning (PSP) using a mouse bioassay. PSP was detected in mussels collected at four sampling sites in English Bay and Burrard Inlet, at a concentration below 20 mug saxitoxin equivalents (STXeq)/100 g wet weight. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Me optimal conditions were established for the extraction of paralytic shellfish poisoning toxins from gonad of Chlamys nobills using acetic acid and hydrochloric acid in the concentration range of 0.04-1.0 mol/L. A 10-g portion of gonad of Chlamys nobilis was extracted by boiling for 5 min with 1.0 mL acetic acid and hydrochloric acid in a 50-mL beaker. Meanwhile, a portion of gonad of Chlamys nobilis was extracted by sonication in the solution of 0.3 mol/L HAc + 0.2 mol/L HCl for a total period of 5-30 min. The raw extract was centrifuged at 3500 r/min for 5 min and the pH of supernatant was adjusted from 2.0 to 4.0 by 0.1 mol/L NaOH or 5 mol/L HCL After passing through a Millipore ultrafiltration membrane (10000 MW cut-off), ultrafiltrate was then analyzed by HPLC. The results showed that hydrochloric acid in the concentration range of 0.25-1.0 mol/L caused a significant decrease of N-sulfocarbarnoyl-11-hydroxysulfate toxin C1 (C1), C2 and gonyautoxin 5 (GTX5) and the concomitant increase of GTX2,3. However, the amount of the three unstable toxins did not show any change using the extraction with acetic acid. Under the same concentration of acetic acid (0.3 mol/L) and hydrochloric acid (0.2 mol/L), the amount of C1 in the ultrasonic extraction was obviously lower than the boiling one, while C2 showed slightly higher than the latter.